999 resultados para Auto-implant


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Put Britney Spears into a YouTube search and the third auto-fill on the list is “Britney Spears without Autotune”. Auto-Tune has become the music industry equivalent of doping in the Tour de France circa 2005; we know everyone’s doing it, but we still have a sense of surprise and outrage when it becomes public. In the last week or so a video has surfaced of the pop singer Britney Spears – with examples of her vocal before and after processing. Whether or not the “before” version is actually the raw material for the “after” version is difficult to say. What’s not difficult to say is that the “before” vocal is distinctly lacking in a demonstrable ability to sing in tune.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bone-anchored prostheses, relying on implants to attach the prosthesis directly to the residual skeleton, are the ultimate resort for patients with transfemoral amputations (TFA) experiencing severe socket discomfort. The first patient receiving a bone-anchored prosthesis underwent the surgery in 1990 in the Sahlgrenska University Hospital (Sweden). To date, there are two commercially available implants: OPRA (Integrum, Sweden) and ILP (Orthodynamics, Germany). The key to success to this technique is a firm bone-implant bonding, depending on increasing mechanical stress applied daily during load bearing exercises (LBE). The loading data could be analysed through different biomechanical variables. The intra-tester reliability of these exercises will be presented here. Moreover the effect of increase of loading, axes of application of the load and body weight as well as the difference between force and moment variables will be discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The importance of firms’ adaptation processes is prominent in today’s business environment which is characterised by ever changing customers, technologies, and competition. Ever since Schumpeter’s (1942) classic work strategic renewal has been found crucial for firms’ adaptation to environmental change. The role of strategic renewal in firms’ adaptation processes includes development of capabilities for the purpose of sustainability of competitive advantage against environmental changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By referring to Niklas Luhmann's theory of self-referential systems, Aldo Mascareño (2008, submitted for publication) gives an account of system-environment interrelatedness, explaining how social and individual constitute each other through the process of communication and co-creation of meanings. Two possible extensions to his account are discussed. Firstly, auto-communication within the system that happens without any external reference needs to be taken into account while describing the existence and constant re-creation of psychic systems. Secondly, in order for the system and environment or two systems to communicate, an imagined and temporary intersubjectivity between the two needs to be assumed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osseointegration has been introduced in the orthopaedic surgery in the 1990’s in Gothenburg (Sweden). To date, there are two frequently used commercially available human implants: the OPRA (Integrum, Sweden) and ILP (Orthodynamics, Germany) systems. The rehabilitation program with both systems include some form of static load bearing exercises. These latter involved following a load progression that is monitored by the bathroom scale, providing only the load applied on the vertical axis. The loading data could be analysed through different biomechanical variables. For instance, the load compliance, corresponding to the difference between the load recommended (LR) and the load actually applied on the implant, will be presented here.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The desire to solve problems caused by socket prostheses in transfemoral amputees and the acquired success of osseointegration in the dental application has led to the introduction of osseointegration in the orthopedic surgery. Since its first introduction in 1990 in Gothenburg Sweden the osseointegrated (OI) orthopedic fixation has proven several benefits[1]. The surgery consists of two surgical procedures followed by a lengthy rehabilitation program. The rehabilitation program after an OI implant includes a specific training period with a short training prosthesis. Since mechanical loading is considered to be one of the key factors that influence bone mass and the osseointegration of bone-anchored implants, the rehabilitation program will also need to include some form of load bearing exercises (LBE). To date there are two frequently used commercially available human implants. We can find proof in the literature that load bearing exercises are performed by patients with both types of OI implants. We refer to two articles, a first one written by Dr. Aschoff and all and published in 2010 in the Journal of Bone and Joint Surgery.[2] The second one presented by Hagberg et al in 2009 gives a very thorough description of the rehabilitation program of TFA fitted with an OPRA implant. The progression of the load however is determined individually according to the residual skeleton’s quality, pain level and body weight of the participant.[1] Patients are using a classical bathroom weighing scale to control the load on the implant during the course of their rehabilitation. The bathroom scale is an affordable and easy-to-use device but it has some important shortcomings. The scale provides instantaneous feedback to the patient only on the magnitude of the vertical component of the applied force. The forces and moments applied along and around the three axes of the implant are unknown. Although there are different ways to assess the load on the implant for instance through inverse dynamics in a motion analysis laboratory [3-6] this assessment is challenging. A recent proof- of-concept study by Frossard et al (2009) showed that the shortcomings of the weighing scale can be overcome by a portable kinetic system based on a commercial transducer[7].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prosthetic benefits of osseointegrated fixation for individuals with limb loss, particularly those with transfemoral amputation (TFA), have been clearly demonstrated in the literature. However, very little information is currently available to established how this prosthetic benefits are translated into functional outcomes and, more precisely, walking abilities [1-3]. The ultimate aim of this presentation was to explore how walking abilities of a TFA fitted with an OPRA fixation could be assess through typical temporal and spatial gait characteristics[2].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed at presenting the intra-tester reliability of the static load bearing exercises (LBEs) performed by individuals with transfemoral amputation (TFA) fitted with an osseointegrated implant to stimulate the bone remodelling process. There is a need for a better understanding of the implementation of these exercises particularly the reliability. The intra-tester reliability is discussed with a particular emphasis on inter-load prescribed, inter-axis and inter-component reliabilities as well as the effect of body weight normalisation. Eleven unilateral TFAs fitted with an OPRA implant performed five trials in four loading conditions. The forces and moments on the three axes of the implant were measured directly with an instrumented pylon including a six-channel transducer. Reliability of loading variables was assessed using intraclass correlation coefficients (ICCs) and percentage standard error of measurement values (%SEMs). The ICCs of all variables were above 0.9 and the %SEM values ranged between 0 and 87%. This study showed a high between-participants’ variance highlighting the lack of loading consistency typical of symptomatic population as well as a high reliability between the loading sessions indicating a plausible correct repetition of the LBE by the participants. However, these outcomes must be understood within the framework of the proposed experimental protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cued recall and item recognition are considered the standard episodic memory retrieval tasks. However, only the neural correlates of the latter have been studied in detail with fMRI. Using an event-related fMRI experimental design that permits spoken responses, we tested hypotheses from an auto-associative model of cued recall and item recognition [Chappell, M., & Humphreys, M. S. (1994). An auto-associative neural network for sparse representations: Analysis and application to models of recognition and cued recall. Psychological Review, 101, 103-128]. In brief, the model assumes that cues elicit a network of phonological short term memory (STM) and semantic long term memory (LTM) representations distributed throughout the neocortex as patterns of sparse activations. This information is transferred to the hippocampus which converges upon the item closest to a stored pattern and outputs a response. Word pairs were learned from a study list, with one member of the pair serving as the cue at test. Unstudied words were also intermingled at test in order to provide an analogue of yes/no recognition tasks. Compared to incorrectly rejected studied items (misses) and correctly rejected (CR) unstudied items, correctly recalled items (hits) elicited increased responses in the left hippocampus and neocortical regions including the left inferior prefrontal cortex (LIPC), left mid lateral temporal cortex and inferior parietal cortex, consistent with predictions from the model. This network was very similar to that observed in yes/no recognition studies, supporting proposals that cued recall and item recognition involve common rather than separate mechanisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background To date bone-anchored prostheses are used to alleviate the concerns caused by socket suspended prostheses and to improve the quality of life of transfemoral amputees (TFA). Currently, two implants are commercially available (i.e., OPRA (Integrum AB, Sweden), ILP (Orthodynamics GmbH, Germany)). [1-17]The success of the OPRA technique is codetermined by the rehabilitation program. TFA fitted with an osseointegrated implant perform progressive mechanical loading (i.e. static load bearing exercises (LBE)) to facilitate bone remodelling around the implant.[18, 19] Aim This study investigated the trustworthiness of monitoring the load prescribed (LP) during experimental static LBEs using the vertical force provided by a mechanical bathroom scale that is considered a surrogate of the actual load applied. Method Eleven unilateral TFAs fitted with an OPRA implant performed five trials in four loading conditions. The forces and moments on the three axes of the implant were measured directly with an instrumented pylon including a six-channel transducer. The “axial” and “vectorial” comparisons corresponding to the difference between the force applied on the long axis of the fixation and LP as well as the resultant of the three components of the load applied and LP, respectively were analysed Results For each loading condition, Wilcoxon One-Sample Signed Rank Tests were used to investigate if significant differences (p<0.05) could be demonstrated between the force applied on the long axis and LP, and between the resultant of the force and LP. The results demonstrated that the raw axial and vectorial differences were significantly different from zero in all conditions (p<0.05), except for the vectorial difference for the 40 kg loading condition (p=0.182). The raw axial difference was negative for all the participants in every loading condition, except for TFA03 in the 10 kg condition (11.17 N). Discussion & Conclusion This study showed a significant lack of axial compliance. The load applied on the long axis was significantly smaller than LP in every loading condition. This led to a systematic underloading of the long axis of the implant during the proposed experimental LBE. Monitoring the vertical force might be only partially reflective of the actual load applied, particularly on the long axis of the implant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This book is a study on learning, teaching/counselling, and research on the two. My quest has been to find a pedagogically-motivated way of researching learning and teaching interaction, and in particular counselling, in an autonomous language-learning environment. I have tried to develop a method that would make room for lived experience, meaning-making and narrating, because in my view these all characterise learning encounters between language learners and counsellors, and learners and their peers. Lived experience as a source of meaning, telling and co-telling becomes especially significant when we try to listen to the diverse personal and academic voices of the past as expressed in autobiographical narratives. I have aimed at researching various ALMS dialogues (Autonomous Learning Modules, University of Helsinki Language Centre English course and programme), and autobiographical narratives within them, in a way that shows respect for the participants, and that is relevant, reflective and, most importantly, self-reflexive. My interest has been in autobiographical telling in (E)FL [(English as a) foreign language], both in students first-person written texts on their language- learning histories and in the sharing of stories between learners and a counsellor. I have turned to narrative inquiry in my quest and have written the thesis as an experiential narrative. In particular, I have studied learners and counsellors in one and the same story, as characters in one narrative, in an attempt to avoid the impression that I am telling yet another separate, anecdotal story, retrospectively. Through narrative, I have shed light on the subjective dimensions of language learning and experience, and have come closer to understanding the emotional aspects of learning encounters. I have questioned and rejected a distanced and objective approach to describing learning and teaching/counselling. I have argued for a holistic and experiential approach to (E)FL encounters in which there is a need to see emotion and cognition as intertwined, and thus to appreciate learners and counsellors emotionally-charged experiences as integral to their identities. I have also argued for a way of describing such encounters as they are situated in history, time, autobiography, and the learning context. I have turned my gaze on various constellations of lived experience: the data was collected on various occasions and in various settings during one course and consists of videotaped group sessions, individual counselling sessions between students and their group counsellor, biographic narrative interviews with myself, open-ended personally-inspired reflection texts written by the students about their language-learning histories, and student logs and diaries. I do not consider data collection an unproblematic occasion, or innocent practice, and I defend the integrity of the research process. Research writing cannot be separated from narrative field work and analysing and interpreting the data. The foci in my work have turned to be the following: 1) describing ALMS encounters and specifying their narrative aspects; 2) reconceptualising learner and teacher autonomy in ALMS and in (E)FL; 2) developing (E)FL methodologically through a teacher-researcher s identity work; 4) research writing as a dialogical narrative process, and the thesis as an experiential narrative. Identity and writing as inquiry, and the deeply narrative and autobiographical nature of the (E)FL teaching/counselling/researching have come to the fore in this research. Research writing as a relational activity and its implications for situated ways of knowing and knowledge turned out to be important foci. I have also focussed on the context-bound and local teacher knowledge and ways of knowing about being a teacher, and I have argued for personal ways of knowing about, and learning and studying foreign languages. I discuss research as auto/biography: as a practising counsellor I use my own life and (E)FL experience to understand and interpret the stories of the research participants even though I was not involved in their course work. The supposedly static binaries of learner/teacher, and also learner autonomy/teacher autonomy, are thus brought into the discussion. I have highlighted the infinite variability and ever-changing nature of learning and teaching English, but the book is also of relevance to foreign language education in general.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Grand Push Auto is an exertion game in which players aim to push a full sized car to ever increasing speeds. The re-appropriation of a car as essentially a large weight allows us to create a highly portable and distributable exertion game in which the main game element has a weight of over 1000 kilograms. In this paper we discuss initial experiences with GPA, and present 3 questions for ongoing study which have been identified from our early testing: How might we appropriate existing objects in exertion game design, and does appropriation change how we think about these objects in different contexts, for example environmental awareness? How does this relate to more traditional sled based weight training? How can we create exertion games that allow truly brutal levels of force?