992 resultados para Acid solutions


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Extraction resins, of the type of;levextrel, (which is a collective term for styrene/divinylbenzene based copolymers of predominantly macroporous structure that contain a selective extractant) are important for the recovery and separation of metal ions, as they combine features of solvent extraction and ion exchange resins. This paper presents the results of the adsorption of heavy rare earth ions (Ho(III), Er(III), Tm(III), Yb(III), Lu(III) and Y(III)) from hydrochloric acid solutions at 0.2 mol/L ionic strength and 50 degrees C by the extraction resin containing di (2,4,4-trimethyl pentyl) phosphinic acid (Cyanex 272) and the chromatographic separation of (Er(III), Tm(III) and Yb(III)). Technological separation products, with purity and yield of Tm2O3 >99.97%, >80%, Er2O3 >99.9%, >94% and Yb2O3 >99.8%, >80% respectively, have been obtained from a feed having the composition Tm2O3 60%, Er2O3 10%, and Yb2O3 3%, the others 27%. The distribution coefficients, extraction equilibrium constants and separation factors have been determined as a function of acidity, loading of the resin and rare earths, flow rates and column ratios. The resolutions and efficiencies of separation of Er/Tm/Yb each other have been calculated. The stoichiometry of the extraction of rare earth ions has been suggested as well.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The electrochemical behavior of Dawson-type P2W18O626- adsorbed on a glassy carbon electrode and doped in a polypyrrole film electrode was described. These modified electrodes all display catalytic activity for nitrite reduction, either in acid solutions or in pH > 4.0 solutions.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The solvent extraction of Sc(III), Zr(IV), Th(IV), Fe(III) and Lu(III) with Cyanex 302 (bis(2,4,4-trimethylpentyl)monothiophosphinic acid) and Cyanex 301 ( bis(2,4,4-trimethylpentyl) dithiophosphinic acid) in n-hexane from acidic aqueous solutions has been investigated systematically. The effect of equilibrium aqueous acidity on the extraction with these reagents was studied. The separation of Th(IV), Fe(III) and Lu(III) from Sc(III), or the separation of other metals from Lu(III) with Cyanex 302, can be achieved by controlling the aqueous acidity. However, Cyanex 301 exhibited a poor selectivity for the above metals, except for Lu(III). The extraction of these metals with Cyanex 272, Cyanex 302 and Cyanex 301 has been compared. The stripping percentages of Sc(III) for Cyanex 302 and Cyanex 301 in a single stage are near 78% and 75% with 3.5 mol/L and 5.8 mol/L sulphuric acid solutions, respectively. The effects of extractant concentration and temperature on the extraction of Sc(III) were investigated. The stoichiometry of the extraction of Sc(III) with Cyanex 302 was determined. The role of different components of Cyanex 302 in the extraction of Sc(III) was discussed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Corrosion inhibition by some new triazole derivatives on mild steel in 1 M hydrochloric acid solutions has been investigated by weight loss test, electrochemical measurement, scanning electronic microscope analysis and quantum chemical calculations. The results indicate that these compounds act as mixed-type inhibitors retarding the anodic and cathodic corrosion reactions and do not change the mechanism of either hydrogen evolution reaction or mild steel dissolution. The studied compounds following the Langmuir adsorption isotherm, and the thermodynamic parameters were determined and discussed. The effect of molecular structure on the inhibition efficiency has been investigated by ab initio quantum chemical calculations. The electronic properties such as highest occupied molecular orbital (HOMO), lowest unoccupied molecular orbital (LUMO) energy levels, energy gap (LUMO-HOMO), dipole moment and molecular orbital densities were calculated. (C) 2009 Published by Elsevier B.V.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Ettringite and thaumasite can be found among the deterioration products of cementitious materials exposed to sulfate and hydrochloric attack. The results of a test program to investigate the acid resistance of self-compacting concrete (SCC) and conventional concrete (CC), immersed up to 18 weeks at 20°C in sulfuric and hydrochloric acid solutions, are described. The SCC was prepared with 47% carboniferous limestone powder, as a replacement for cement, and an ordinary portland cement. The CC was prepared with portland cement only. The water-binder ratios of the SCC and CC were 0.36 and 0.46, respectively. The parameter investigated was the time, in weeks, taken to cause 10% mass loss of fully immersed concrete specimens in a 1% solution of sulfuric acid and the same amount of loss in a 1% solution of hydrochloric acid. The investigation indicated that the SCC performed better than the CC in sulfuric solution but was slightly more vulnerable to hydrochloric acid attack compared to CC. The mode of attack between the two solutions was different.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Natural Bulgarian clinoptilolite from the south-eastern Rhodopes mountain was modified through treatment with hydrochloric acid with various normality, both single and repeatedly, as well as through a charring of a preliminary obtained NH4-form. The parameters concerning the uptake of the ion-exchangeable cations (Ca2+, Na+ and K+), as well as the uptake of aluminium from the natural material were calculated on the basis of the chemical contents. The highest extent of cations removal was attained in the case of the treatment with NH4Cl solution, while the highest aluminium deficiency was established in the samples treated by hydrochloric acid solutions with increasing concentration. Sulfur dioxide adsorption on the obtained decationised and dealuminised samples was studied according to the frontal-dynamic method. The parameters of the breakthrough curves, namely breakthrough time, saturation time and some of the statistical moments of the curve distribution, were determined. The dynamic adsorption capacities were also specified. Comparing the momentum values it was established that as a result of the natural zeolite treatment with NH4Cl and with low concentrated acid, the diffusion resistance decreases because of the dominant exchange of the presenting exchangeable cations in the samples with the smaller size protons and because of enlargement of the pores opening. Intensified dealuminisation was observed when more concentrated acid solutions are used. The capacity is enhanced, probably due to an increase in the total pore volume.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fluorescence is a troublesome side effect in laboratory Raman studies on sulfuric acid solutions and aerosol particles. We performed experiments showing that organic matter induces fluorescence in H2SO4/H2O solutions. The intensity of the fluorescence signal appears to be almost independent of the concentration of the organic substances, but depends strongly on the sulfuric acid concentration. The ubiquity of organic substances in the atmosphere, their relatively high abundance, and the insensitivity of the fluorescence with respect to their concentrations will render most acidic natural aerosols subject to absorption and fluorescence, possibly influencing climate forcing. We show that, while fluorescence may in the future become a valuable tool of aerosol diagnostics, the concurrent absorption is too small to significantly affect the atmosphere's radiative balance.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Microwave-assisted sample preparation using diluted nitric acid solutions is an alternative procedure for digesting organic samples. The efficiency of this procedure depends on the chemical properties of the samples and in this work it was evaluated by the determination of crude protein amount. fat and original carbon. Soybeans grains, bovine blood. bovine muscle and bovine viscera were digested in a cavity-microwave oven using oxidant mixtures in different acid concentrations. The digestion efficiency was evaluated based on the determination of residual carbon content and element recoveries using inductively coupled plasma optical emission spectrometry (ICP OES). In order to determine the main residual organic compounds, the digests were characterized by nuclear magnetic resonance (1 H NMR). Subsequently, studies concerning separation of nitrobenzoic acid isomers were performed by ion pair reversed phase liquid chromatography using a C18 stationary phase, water:acetonitrile:methanol (75:20:5, v/v/v) +0.05% (v/v) TFA as mobile phase and ultraviolet detection at 254 nm. Sample preparation based on diluted acids proved to be feasible and a recommendable alternative for organic sample digestion, reducing both the reagent volumes and the variability of the residues as a result of the process of decomposition. It was shown that biological matt-ices containing amino acids, proteins and lipids in their composition produced nitrobenzoic acid isomers and other organic compounds after cleavage of chemical bonds. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aims of this study were to determine the effects of pH and acid concentration on the dissolution of enamel, dentine, and compressed hydroxyapatite (HA) in citric acid solutions (15.6 and 52.1 mmol l(-1) ; pH 2.45, 3.2, and 3.9), using a pH-stat system. After an initial adjustment period, the dissolution rates of enamel and HA were constant, while that of dentine decreased with time. The dissolution rate increased as the pH decreased, and this was most marked for enamel. To compare substrates, the rate of mineral dissolution was normalized to the area occupied by mineral at the specimen surface. For a given acid concentration, the normalized dissolution rate of HA was always less than that for either dentine or enamel. The dissolution rate for dentine mineral was similar to that for enamel at pH 2.45 and greater at pH 3.2 and pH 3.9. The concentration of acid significantly affected the enamel dissolution rate at pH 2.45 and pH 3.2, but not at pH 3.9, and did not significantly affect the dissolution rates of dentine or HA at any pH. The variation in response of the dissolution rate to acid concentration/buffer capacity with respect to pH and tissue type might complicate attempts to predict erosive potential from solution composition.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Results of a systematic study concerning non-spectral interferences from sulfuric acid containing matrices on a large number of elements in inductively coupled plasma–mass spectrometry (ICP-MS) are presented in this work. The signals obtained with sulfuric acid solutions of different concentrations (up to 5% w w− 1) have been compared with the corresponding signals for a 1% w w− 1− nitric acid solution at different experimental conditions (i.e., sample uptake rates, nebulizer gas flows and r.f. powers). The signals observed for 128Te+, 78Se+ and 75As+ were significantly higher when using sulfuric acid matrices (up to 2.2-fold for 128Te+ and 78Se+ and 1.8-fold for 75As+ in the presence of 5 w w-1 sulfuric acid) for the whole range of experimental conditions tested. This is in agreement with previously reported observations. The signal for 31P+ is also higher (1.1-fold) in the presence of sulfuric acid. The signal enhancements for 128Te+, 78Se+, 75As+ and 31P+ are explained in relation to an increase in the analyte ion population as a result of charge transfer reactions involving S+ species in the plasma. Theoretical data suggest that Os, Sb, Pt, Ir, Zn and Hg could also be involved in sulfur-based charge transfer reactions, but no experimental evidence has been found. The presence of sulfuric acid gives rise to lower ion signals (about 10–20% lower) for the other nuclides tested, thus indicating the negative matrix effect caused by changes in the amount of analyte loading of the plasma. The elemental composition of a certified low-density polyethylene sample (ERM-EC681K) was determined by ICP-MS after two different sample digestion procedures, one of them including sulfuric acid. Element concentrations were in agreement with the certified values, irrespective of the acids used for the digestion. These results demonstrate that the use of matrix-matched standards allows the accurate determination of the tested elements in a sulfuric acid matrix.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Bentonite is a natural clay mineral widely used in the mining and solid waste containment industry, for example, as a soil mixture for the construction of seepage barriers, or as a component of geosynthetic clay liners (GCLs), to provide low hydraulic conductivity. However, degradation of bentonites generally occurs when permeated with acid solutions, such as encountered in mining applications, which may influence physical properties, and particularly, the hydraulic performance of geosynthetic clay liners.In this paper, properties such as Atterberg limits, free swell index, and fluid loss of three bentonites were measured with different concentrations of sulphuric acid solutions. These properties were found to deteriorate even with low (0.015 M) sulphuric acid solutions; higher concentrations (up to 1 M) resulted in larger degradation. X-ray diffraction and infrared spectroscopy were used to monitor the change of bentonites after interaction with the acid solutions. Acid leachates in general result in the overall degradation of the hydraulic performance of geosynthetic clay liners and potentially, any bentonite-soil mixture.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The kinetics of iron(II1) extraction by bis(Zethylhexy1) phosphate (HDEHP, HA) in kerosene from sulfuric acid solutions has been studied in a liquid-liquid laminar jet reactor. The contact time of the interface in this reacting device is of the same order of magnitude as the surface renewal time in dispersion mixing and much less than that obtained in the relatively quiescent condition of the Lewis cell. Yet the analysis of the data in this study suggested a rate-controlling step involving surface saturation quite in conformity with that obtained in the Lewis cell and not with that in dispersion mixing as reported in the literature. Further, the mechanism suggested a weaker dependence of the rate on hydrogen ion concentration which was reported by other workers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Assessment of heavy metal bioavailability in sediments is complex because of the number of partial extraction methods available for the assessment and the general lack of certified reference materials. This study evaluates five different extraction methodologies to ascertain the relative strengths and weaknesses of each method. The results are then compared to previously published work to ascertain the most effective partial extraction technique, which was established to be dilute (0.75 – 1 M) nitric acid solutions. These results imply that single reagent; weak acid extractions provide a better assessment of potentially bioavailable metals than the chelating agents used in sequential extraction methods.