292 resultados para ADC
Resumo:
The excellence of its flesh and fast growth makes the dourado, Salminus brasiliensis, a carnivorous fish native to the Prata basin, a potential candidate for intensive fish farming. This study evaluated the apparent digestibility coefficients (ADC) of energy and nutrients of animal and plant protein sources for the carnivorous Characin dourado S. brasiliensis. Fish (19.5 +/- 5.0 g) were stocked in plastic cages (80-L) and fed pelleted test diets containing 30% of the test ingredient [fish meal (FM), poultry by-product meal (PBM), soybean meal (SBM), and corn gluten meal (CGM) plus 70% of a reference diet (481.4 g kg(-1) of crude protein and 18.63 kJ of gross energy per gram]. After the last daily meal, cages were transferred to cylindrical, conical-bottomed aquarium (200-L) where faeces were collected by sedimentation in a refrigerated container. Except for ADC of protein and energy, all other ADC of nutrients showed significant differences (P < 0.01). ADC values were: 94.3%, 91.3%, 93.1%, and 93.5% for crude protein; 91.0%, 90.3%, 87.8%, and 88.8% for gross energy; 92.1%, 84.5%, 80.6%, and 79.3% for ash; 83.9%, 80.3%, 84.3%, and 84.6% for dry matter; 97.4%, 96.7%, 93.3%, and 91.5% for lipid for FM, PBM, SBM, and CGM, respectively. The average amino acid ADC was: 93.6%, 90.0%, 92.1%, and 92.5% of FM, PBM, SBM, and CGM, respectively. All test ingredients were efficiently used and can partially replace FM in diets for carnivorous dourado.
Resumo:
Using the fish silage to partially replace proteic feedstuff in aquafeeds is an alternative to mitigate sanitary and environmental problems caused by the lack of adequate destination for fisheries residues. It would also lower feed costs, consequently improving fish culture profitability. However, using fish silages in aquafeeds depends on determination of its apparent digestibility coefficients (ADC). This work aimed to determining the ADC of crude protein and amino acids of acid silage (AS), biological silage (BS) and enzymatic silage (ES) for juvenile Nile tilapia (94.5 +/- 12.7 g). The ADC(CP) was: 92.0%, 89.1% and 93.7% for AS, BS and SE respectively. The average ADC of amino acids was: 91.8%, 90.8% and 94.6% for AS, BS and ES respectively. Results encourage the use of AS, BS and ES to partially replace protein sources in balanced diets for neotropical fish.
Resumo:
Background and Purpose-The Echoplanar Imaging Thrombolysis Evaluation Trial ( EPITHET) tests the hypothesis that perfusion-weighted imaging (PWI)-diffusion-weighted imaging (DWI) mismatch predicts the response to thrombolysis. There is no accepted standardized definition of PWI-DWI mismatch. We compared common mismatch definitions in the initial 40 EPITHET patients. Methods-Raw perfusion images were used to generate maps of time to peak (TTP), mean transit time (MTT), time to peak of the impulse response (Tmax) and first moment transit time (FMT). DWI, apparent diffusion coefficient ( ADC), and PWI volumes were measured with planimetric and thresholding techniques. Correlations between mismatch volume (PWIvol-DWIvol) and DWI expansion (T2(Day) (90-vol)-DWIAcute-vol) were also assessed. Results-Mean age was 68 +/- 11, time to MRI 4.5 +/- 0.7 hours, and median National Institutes of Health Stroke Scale (NIHSS) score 11 (range 4 to 23). Tmax and MTT hypoperfusion volumes were significantly lower than those calculated with TTP and FMT maps (P < 0.001). Mismatch >= 20% was observed in 89% (Tmax) to 92% (TTP/FMT/MTT) of patients. Application of a +4s ( relative to the contralateral hemisphere) PWI threshold reduced the frequency of positive mismatch volumes (TTP 73%/FMT 68%/Tmax 54%/MTT 43%). Mismatch was not significantly different when assessed with ADC maps. Mismatch volume, calculated with all parameters and thresholds, was not significantly correlated with DWI expansion. In contrast, reperfusion was correlated inversely with infarct growth (R= -0.51; P = 0.009). Conclusions-Deconvolution and application of PWI thresholds provide more conservative estimates of tissue at risk and decrease the frequency of mismatch accordingly. The precise definition may not be critical; however, because reperfusion alters tissue fate irrespective of mismatch.
Resumo:
OBJECTIVE. Toxic leukoencephalopathy may present acutely or subacutely with symmetrically reduced diffusion in the periventricular and supraventricular white matter, hereafter referred to as periventricular white matter. This entity may reverse both on imaging and clinically. However, a gathering together of the heterogeneous causes of this disorder as seen on MRI with diffusion-weighted imaging (DWI) and an analysis of their likelihood to reverse has not yet been performed. Our goals were to gather causes of acute or subacute toxic leukoencephalopathy that can present with reduced diffusion of periventricular white matter in order to promote recognition of this entity, to evaluate whether DWI with apparent diffusion coefficient (ADC) values can predict the extent of chronic FLAIR abnormality ( imaging reversibility), and to evaluate whether DWI can predict the clinical outcome ( clinical reversibility). MATERIALS AND METHODS. Two neuroradiologists retrospectively reviewed the MRI examinations of 39 patients with acute symptoms and reduced diffusion of periventricular white matter. The reviewers then scored the extent of abnormality on DWI and FLAIR. ADC ratios of affected white matter versus the unaffected periventricular white matter were obtained. Each patient`s clinical records were reviewed to determine the cause and clinical outcome. Histology findings were available in three patients. Correlations were calculated between the initial MRI markers and both the clinical course and the follow-up extent on FLAIR using Spearman`s correlation coefficient. RESULTS. Of the initial 39 patients, seven were excluded because of a nontoxic cause (hypoxic-ischemic encephalopathy [HIE] or congenital genetic disorders) or because of technical errors. In the remaining 32 patients, no correlation was noted between any of the initial MRI markers (percentage of ADC reduction, DWI extent, or FLAIR extent) with the clinical outcome. Three patients had histologic correlation. However, moderate correlation was seen between the extent of abnormality on initial FLAIR and the extent on follow-up FLAIR (r = 0.441, p = 0.047). Of the 13 patients who underwent repeat MRI at 21 days or longer, the reduced diffusion resolved in all but one. Significant differences were noted between ADC values in affected white matter versus unaffected periventricular white matter on initial (p < 0.0001) but not on follow-up MRI (p = 0.13), and in affected white matter on initial versus follow-up (p = 0.0014) in those individuals who underwent repeat imaging on the same magnet (n = 9), confirming resolution of the DWI abnormalities. CONCLUSION. Acute toxic leukoencephalopathy with reduced diffusion may be clinically reversible and radiologically reversible on DWI, and may also be reversible, but to a lesser degree, on FLAIR MRI. None of the imaging markers measured in this study appears to correlate with clinical outcome, which underscores the necessity for prompt recognition of this entity. Alerting the clinician to this potentially reversible syndrome can facilitate treatment and removal of the offending agent in the early stages.
Resumo:
Quando foi publicado o “novo” Regime Jurídico da Concorrência (RJC) no D.R. de 8/5/12, logo se falou de “grande reforma no sector da concorrência” por “iluminados”. Acontece que de acordo com o art. 101º do RJC, a lei só entraria em vigor passados 60 dias. Até aqui tudo normal. É preciso uma “vacatio legis” para a adaptação dos destinatários, incluindo a Autoridade da Concorrência (AdC). Abstract: When published the "new" Legal Framework for Competition (RJC) in DR 05.08.12, soon spoke of "major reform in the competitive sector" by "enlightened". It turns out that according to art. 101 of the RJC, the law would only enter into force after 60 days. So far so normal. It takes a "vacatio legis" to adapt the recipients, including the Competition Authority (CA).
Resumo:
Várias são as “janelas” da Ressonância Magnética (RM) que hoje têm aplicação na clínica. Servem para fundamentar o diagnóstico (p.e., da encefalopatia microvascular do idoso), o prognóstico (p.e., do declínio cognitivo), a terapêutica (p.e., da desmielinização primária). Com elas também poderemos aceder ao estudo fiável da substância branca aparentemente normal (T2 convencional), o que será importante para prever a evolução. Havendo, agora, uma outra contrastização quantificável – sem T1 nem T2 –, a designação genérica dos métodos será RMq. Duas são as nossas interrogações durante a execução e interpretação da RMq. A primeira, de índole executiva, questiona o enquadramento clínico destes estudos estruturais? De modo isolado ou partilhado? Opinamos que as duas “janelas” da RMq serão complementares e, por isso, de comum aplicação por rotina – transferência da magnetização (TM) e difusão protónica (D/ADC). Por que as consideramos complementares entre si? Porque cada uma, a seu modo, ou seja, pela interacção da água ligada às macromoléculas, na TM, e pelo movimento molecular activo, na D/ADC, é propícia à medição da estrutura e da neurobiologia. Para ambas, o substrato será a célula com a membrana de mielina e a água, que lhe estar estará associada. Então, a RMq será uma sonda in vivo para a função. A interrogação interpretativa prende-se com a analogia entre a estrutura, que pretendemos ler, e a neurobiologia, que supomos deduzir. Tal resposta tem uma praxis muito estrita, porque a RMq estuda o cérebro vivo e contido no crânio. O conhecimento terá o seu episteme não só na Clínica, que o lidera, mas também na Imagiologia, que connosco recriará os protocolos de investigação.
Design of improved rail-to-rail low-distortion and low-stress switches in advanced CMOS technologies
Resumo:
This paper describes the efficient design of an improved and dedicated switched-capacitor (SC) circuit capable of linearizing CMOS switches to allow SC circuits to reach low distortion levels. The described circuit (SC linearization control circuit, SLC) has the advantage over conventional clock-bootstrapping circuits of exhibiting low-stress, since large gate voltages are avoided. This paper presents exhaustive corner simulation results of a SC sample-and-hold (S/H) circuit which employs the proposed and optimized circuits, together with the experimental evaluation of a complete 10-bit ADC utilizing the referred S/H circuit. These results show that the SLC circuits can reduce distortion and increase dynamic linearity above 12 bits for wide input signal bandwidths.
Resumo:
Paper to be presented in ESREA 2007 ADC Network Seminar - Changing Relationships between the State, Civil Society and the Citizen: Implications for adult education and adult learning, 14 -16 June 2007 - University of Minho - Campus de Gualtar, Braga (Portugal).
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde.
Resumo:
Objetivos – Com este estudo pretendeu-se i) avaliar o contributo da aplicação da sequência de difusão na caracterização das lesões mamárias malignas; ii) considerar se a sequência de difusão deve incorporar o protocolo standard em RM mamária e iii) correlacionar os resultados dos valores de coeficiente aparente de difusão (ADC) e os resultados histológicos. Metodologia – A amostra incluiu 18 pacientes do sexo feminino, com idades compreendidas entre 38 e 71 anos, que apresentavam lesões mamárias malignas confirmadas histologicamente. Foi adicionado ao protocolo de RM mamária a sequência de difusão, de modo a calcular os valores de ADC das lesões observadas. Resultados – Verificou-se que a range de valores de ADC para lesões malignas em ROI’s calculados no centro da lesão apresentavam uma média e desvio-padrão de (0,89 ± 0,14x10-3mm2/s). O método da utilização dos valores de ADC na caracterização de lesões mamárias malignas demonstrou uma sensibilidade de 100%. Conclusões – Neste estudo, com uma sensibilidade de 100%, a ponderação em difusão demonstrou ser uma técnica vantajosa na caracterização de lesões mamárias malignas pelo que se sugere a sua introdução no protocolo standard da RM mamária. ABSTRACT - Aims – The aim of this study was i) to evaluate the potential of the DWI sequence in the characterization of malignant breast lesions; ii) to verify if this sequence should incorporate the breast MRI protocol and iii) to correlate the apparent diffusion coefficients (ADC) values and histological results. Methodology – The sample includes 18 female patients between the ages of 38 and 71 years, who presented with malignant breast lesion confirmed by histology. The DWI sequence was added to the MRI standard protocol to calculate the ADC values. Results – In the results obtained we observed that the range of the ADC values calculated in the center of the malignant lesions, showed a mean and standard deviation of 0.89 ± 0.14 x10-3 mm2 / s. This method of using the ADC values for the detection of malignant lesions showed a sensitivity of 100%. Conclusion – The DWI technique proved to be a useful method in the characterization of malignant breast lesions, as it showed a sensitivity of 100%, so we suggest its inclusion in the Breast MR standard protocol.
Resumo:
Introdução – A técnica de Difusão por Ressonância Magnética (RM), ao avaliar o movimento das moléculas de água nos tecidos, permite inferir sobre a arquitetura dos mesmos, em particular relativamente à celularidade, volume celular e permeabilidade das membranas. O Coeficiente de Difusão Aparente (ADC) é um parâmetro quantificável da imagem ponderada em difusão (DWI). A sua análise poderá fornecer informação clínica adicional sobre estas lesões, sobretudo em relação à sua caracterização histológica. Objetivos – Caracterizar e diferenciar tipos e alguns subtipos de lesões mamárias através da análise do ADC. Metodologia – 20 Mulheres com 23 lesões mamárias foram submetidas a RM mamária: 3 lesões benignas (3 Fibroadenomas-FA) e 20 malignas (16 Carcinomas Ductais Invasivos-CDI, 2 Carcinomas Ductais In Situ-CDIS e 2 Carcinomas Invasivos Lobulares-CLI). Num equipamento 1.5T aplicou-se uma sequência de Difusão (b=0,50,250,500,750,1000 s/mm2). Obteve-se o ADC através do ajuste exponencial da intensidade de sinal das lesões em função do valor de b, fazendo-se corresponder os valores de ADC à respetiva caracterização histológica e posterior comparação com a literatura. Resultados e Discussão – As lesões malignas apresentaram ADCs significativamente (p=0,014) inferiores [(0,94±0,22)x10-3 mm2/s] aos das benignas [(1,43±0,25)x10-3 mm2/s]. A justificação pode residir no aumento da celularidade e consequente restrição da Difusão que se observa nas lesões malignas. Os CDI apresentaram ADCs baixos [(0,88±0,17)x10-3 mm2/s], enquanto que os CDIS apresentaram ADCs mais elevados [(1,33±0,29)x10-3 mm2/s]. Estes resultados estão de acordo com o facto dos CDIS estarem limitados aos ductos mamários, mantendo-se menos alterada a estrutura do tecido adjacente e resultando numa menor restrição à difusão que nos CDI. Verificaram-se diferenças significativas entre FA e CDI (p=0,010) e entre CDI e CDIS (p=0,049). Conclusões – O ADC possibilita a diferenciação entre lesões mamárias benignas e malignas, bem como entre alguns tipos histológicos. O desenvolvimento deste conceito pode representar um avanço no papel da RM na avaliação destas neoplasias. ABSTRACT - Introduction – The Magnetic Resonance (MR) diffusion technique measures the movement of water molecules in tissues. Therefore, it provides useful information about tissue architecture, specially regarding tissue cellularity, cell volume and membrane permeability. The quantification of diffusion weighted imaging (DWI) data is done by measuring the so-called. Apparent Diffusion Coefficient (ADC). This parameter provides additional clinical information about breast lesions, and potentially allows for in-vivo histological characterization. Purpose – To characterize and differentiate breast lesions through ADC analysis. Methodology – The study comprised 20 women, with 23 breast lesions: 3 benign lesions - 3 Fibroadenomas (FA); and 20 malignant - 16 Invasive Ductal Carcinomas (CDI), 2 Ductal Carcinomas In Situ (CDIS), 2 Invasive Lobular Carcinoma (CLI). On a 1.5T equipment a diffusion-weighted sequence with 6 b-values (b=0,50,250,500,750,1000 s/mm2) was used to examine the patients. ADC was obtained by fitting an exponential to data of lesion signal intensity vs. b values. A correspondence of ADC values to histological lesion characterization was done and finally, the results were comparison with the literature. Results and Discussion – Malignant lesions showed inferior ADCs significantly (p=0.014) lower ((0.94±0.22)x10-3 mm2/s) than the benign lesions ((1.43±0.25)x10-3 mm2/s). This may be associated to increasead cellularity in malignant lesions, which result in higher tissue restriction to diffusion. CDI showed low ADC values ((0.88±0.17)x10-3 mm2/s), while the CDIS showed higher ADCs ((1.33±0.29)x10-3 mm2/s). These results agree with the fact that CDIS are limited to mammary ducts, maintaining a less altered neighboring tissue structure, which results in a lower restriction to diffusion than observed in CDI. Significant differences between FA and CDI (p=0.010) and between CDI and CDIS (p=0.049) were observed. Conclusion – The ADC parameter is able to differentiate between malignant and benign breast lesions, as well as between some histological types.
Resumo:
A imagem por difusão em RM caracteriza o movimento microscópico e aleatório das moléculas de água no tecido e a sua quantificação através do ADC permite avaliar a celularidade e estrutura do mesmo. O valor b corresponde ao factor de sensibilização à difusão, sendo que as imagens podem ser mais ou menos ponderadas em difusão. Segundo vários autores torna-se importante a determinação dos valores de b mais adequados pois este parâmetro é variável com o tipo de equipamento utilizado, podendo influenciar a qualidade diagnóstica do método.
Resumo:
O estudo das curvas características de um transístor permite conhecer um conjunto de parâmetros essenciais à sua utilização tanto no domínio da amplificação de sinais como em circuitos de comutação. Deste estudo é possível obter dados em condições que muitas vezes não constam na documentação fornecida pelos fabricantes. O trabalho que aqui se apresenta consiste no desenvolvimento de um sistema que permite de forma simples, eficiente e económica obter as curvas características de um transístor (bipolar de junção, efeito de campo de junção e efeito de campo de metal-óxido semicondutor), podendo ainda ser utilizado como instrumento pedagógico na introdução ao estudo dos dispositivos semicondutores ou no projecto de amplificadores transistorizados. O sistema é constituído por uma unidade de condicionamento de sinal, uma unidade de processamento de dados (hardware) e por um programa informático que permite o processamento gráfico dos dados obtidos, isto é, traçar as curvas características do transístor. O seu princípio de funcionamento consiste na utilização de um conversor Digital-Analógico (DAC) como fonte de tensão variável, alimentando a base (TBJ) ou a porta (JFET e MOSFET) do dispositivo a testar. Um segundo conversor fornece a variação da tensão VCE ou VDS necessária à obtenção de cada uma das curvas. O controlo do processo é garantido por uma unidade de processamento local, baseada num microcontrolador da família 8051, responsável pela leitura dos valores em corrente e em tensão recorrendo a conversores Analógico-Digital (ADC). Depois de processados, os dados são transmitidos através de uma ligação USB para um computador no qual um programa procede à representação gráfica, das curvas características de saída e à determinação de outros parâmetros característicos do dispositivo semicondutor em teste. A utilização de componentes convencionais e a simplicidade construtiva do projecto tornam este sistema económico, de fácil utilização e flexível, pois permite com pequenas alterações
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
Electronics Letters Vol.38, nº 19