976 resultados para 64-ROW


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nearest–neighbour balance is considered a desirable property for an experiment to possess in situations where experimental units are influenced by their neighbours. This paper introduces a measure of the degree of nearest–neighbour balance of a design. The measure is used in an algorithm which generates nearest–neighbour balanced designs and is readily modified to obtain designs with various types of nearest–neighbour balance. Nearest–neighbour balanced designs are produced for a wide class of parameter settings, and in particular for those settings for which such designs cannot be found by existing direct combinatorial methods. In addition, designs with unequal row and column sizes, and designs with border plots are constructed using the approach presented here.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective ""CORE-64"" trial (""Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors""). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To evaluate whether the A/G polymorphism at position 2518 in the regulatory region of the monocyte chemoattractant protein-1 (MCP-1) or the V/I polymorphism at position 64 of the receptor. CCR2, are associated with lupus nephritis (LN) or any clinical characteristics of the disease or with renal survival in a patient population. Methods. We selected 197 patients with lupus nephritis and 220 matched healthy controls for study. MCP-1 and CCR2 genotyping was performed by polymerase chain reaction. Clinical and laboratory data were compiled from patients` charts over followup that ranged from 6 months to 10 years. Results. The GIG genotype of MCP-1 was more common in LN patients (p = 0.019), while the A allele was associated with healthy controls (p = 0.007) as was the V allele of CCR2 (p = 0.046) compared to LN patients. Clinical index measures [SLE Disease Activity Index (SLEDAI)], immunological markers, renal histology, renal function at enrollment, and renal survival were not influenced by these polymorphisms. A less aggressive renal disease, measured by renal SLEDAI index, was associated with the V allele of the CCR2 gene polymorphism. Conclusion. These findings support that MCP-1 2518 GIG is associated with LN but there was no association of this genotype with renal function or renal survival. When studying CCR2 64 V/I polymorphism we showed a positive association of the V allele with healthy controls but no association of the genotype with LN patients. (First Release March 152010; J Rheumatol 2010;37:776-82; doi:10.3899/jrheum.090681)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE. The purpose of the study was to investigate patient characteristics associated with image quality and their impact on the diagnostic accuracy of MDCT for the detection of coronary artery stenosis. MATERIALS AND METHODS. Two hundred ninety-one patients with a coronary artery calcification (CAC) score of <= 600 Agatston units (214 men and 77 women; mean age, 59.3 +/- 10.0 years [SD]) were analyzed. An overall image quality score was derived using an ordinal scale. The accuracy of quantitative MDCT to detect significant (>= 50%) stenoses was assessed using quantitative coronary angiography (QCA) per patient and per vessel using a modified 19-segment model. The effect of CAC, obesity, heart rate, and heart rate variability on image quality and accuracy were evaluated by multiple logistic regression. Image quality and accuracy were further analyzed in subgroups of significant predictor variables. Diagnostic analysis was determined for image quality strata using receiver operating characteristic (ROC) curves. RESULTS. Increasing body mass index (BMI) (odds ratio [OR] = 0.89, p < 0.001), increasing heart rate (OR = 0.90, p < 0.001), and the presence of breathing artifact (OR = 4.97, p = 0.001) were associated with poorer image quality whereas sex, CAC score, and heart rate variability were not. Compared with examinations of white patients, studies of black patients had significantly poorer image quality (OR = 0.58, p = 0.04). At a vessel level, CAC score (10 Agatston units) (OR = 1.03, p = 0.012) and patient age (OR = 1.02, p = 0.04) were significantly associated with the diagnostic accuracy of quantitative MDCT compared with QCA. A trend was observed in differences in the areas under the ROC curves across image quality strata at the vessel level (p = 0.08). CONCLUSION. Image quality is significantly associated with patient ethnicity, BMI, mean scan heart rate, and the presence of breathing artifact but not with CAC score at a patient level. At a vessel level, CAC score and age were associated with reduced diagnostic accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Iron chelators of the 2-pyridinecarbaldehyde isonicotinoylhydrazone (HPCIH) class show high potential for the treatment of iron overload diseases. In the present study, selected first-row transition metal (from Mn to Zn) complexes with HPCIH and 2-pyridinecarbaldehyde (4'-aminobenzoyl)hydrazone (HPCAH) were synthesised and characterised. Crystallography reveals that HPCAH exclusively forms bis complexes with divalent transition metals, with each ligand coordinating meridionally through its pyridine-N, imine-N and carbonyl-O atoms, forming distorted octahedral cis-MN4O2 complexes. Complexes of HPCIH were more varied and unpredictable, with metal/ligand ratios of 1:1, 1:2, 2:2 and 3:2 obtained with different metal ions. The isonicotinoyl ring N-atom in HPCIH was found to be an effective ligand, and this resulted in the varied metal/ligand ratios observed. The formation constants of divalent metal complexes with HPCIH were determined by potentiometric titrations and the values obtained were consistent with similar tridentate ligands and with the Irving-Williams order. ((C) Wiley-VCH Verlag GmbH & Co. KGaA, 69451 Weinheim, Germany, 2003).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Investiga-se a convergência de conjuntos de bases em direção ao limite numérico da energia Hartree-Fock (HF) total para as seqüências hierárquicas dos conjuntos de bases XZP e ccpVXZ. Para as duas hierarquias, melhoramentos significativos são obtidos com cada incremento em X. Para estimar o limite do conjunto de base completo, uma forma exponencial foi usada. Entre as várias aproximações consideradas aqui, uma extrapolação exponencial de três parâmetros aplicada aos resultados TZP, QZP e 5ZP deu os limites do conjunto de bases mais precisos. Em adição, energias HF dos orbitais moleculares ocupados mais altos de algumas moléculas diatômicas foram calculadas com o conjunto 5ZP e comparadas com as correspondentes obtidas com o conjunto cc-pV5Z e com um método numérico HF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although it is always weak between RFID Tag and Terminal in focus of the security, there are no security skills in RFID Tag. Recently there are a lot of studying in order to protect it, but because it has some physical limitation of RFID, that is it should be low electric power and high speed, it is impossible to protect with the skills. At present, the methods of RFID security are using a security server, a security policy and security. One of them the most famous skill is the security module, then they has an authentication skill and an encryption skill. In this paper, we designed and implemented after modification original SEED into 8 Round and 64 bits for Tag.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Boletim elaborado pela Assessoria de Comunicação e Imprensa da Reitoria da UNESP

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Revista elaborada pela Assessoria de Comunicação e Imprensa da Reitoria da UNESP

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary artery disease (CAD) is currently one of the most prevalent diseases in the world population and calcium deposits in coronary arteries are one direct risk factor. These can be assessed by the calcium score (CS) application, available via a computed tomography (CT) scan, which gives an accurate indication of the development of the disease. However, the ionising radiation applied to patients is high. This study aimed to optimise the protocol acquisition in order to reduce the radiation dose and explain the flow of procedures to quantify CAD. The main differences in the clinical results, when automated or semiautomated post-processing is used, will be shown, and the epidemiology, imaging, risk factors and prognosis of the disease described. The software steps and the values that allow the risk of developingCADto be predicted will be presented. A64-row multidetector CT scan with dual source and two phantoms (pig hearts) were used to demonstrate the advantages and disadvantages of the Agatston method. The tube energy was balanced. Two measurements were obtained in each of the three experimental protocols (64, 128, 256 mAs). Considerable changes appeared between the values of CS relating to the protocol variation. The predefined standard protocol provided the lowest dose of radiation (0.43 mGy). This study found that the variation in the radiation dose between protocols, taking into consideration the dose control systems attached to the CT equipment and image quality, was not sufficient to justify changing the default protocol provided by the manufacturer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quando estudamos a civilização egípcia há dois fenômenos que, inevitavelmente, nos surpreendem. Um prende-se com a durabilidade desta civiUzação. O ouü-o refere-se à manutenção quase absoluta das diferentes expressões do seu rosto. Aparentemente, uma e outi-a realidade são distintas, mas quando nos debmçamos sobre a história do Egipto faraônico compreendemos que ela durou, exactamente por que se manteve, ao longo de ti-ês milênios, fechada sobre si própria, num discurso e numa posUira que remontava às origens do mundo e da sua história.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quest for new antiparasitic alternatives has led researchers to base their studies on insights into biology, host-parasite interactions and pathogenesis. In this context, proteases and their inhibitors are focused, respectively, as druggable targets and new therapy alternatives. Herein, we proposed to evaluate the in vitro effect of the cysteine protease inhibitor E-64 on Giardia trophozoites growth, adherence and viability. Trophozoites (105) were exposed to E-64 at different final concentrations, for 24, 48 and 72 h at 37 °C. In the growth and adherence assays, the number of trophozoites was estimated microscopically in a haemocytometer, whereas cell viability was evaluated by a dye-reduction assay using MTT. The E-64 inhibitor showed effect on growth, adherence and viability of trophozoites, however, its better performance was detected in the 100 µM-treated cultures. Although metronidazole was more effective, the E-64 was shown to be able to inhibit growth, adherence and viability rates by ≥ 50%. These results reveal that E-64 can interfere in some crucial processes to the parasite survival and they open perspectives for future investigations in order to confirm the real antigiardial potential of the protease inhibitors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho de Projecto apresentado para cumprimento dos requisitos necessários à obtenção do grau de Mestre em Tradução, área de especialização em Inglês