991 resultados para 291502 Rehabilitation Engineering
Resumo:
The conventional method of attachment of prosthesis involves on a socket. A new method relying on osseointegrated fixation is emerging. It has significant prosthetic benefits. Only a few studies demonstrated the biomechanical benefits. The specific objective of this study was to present the key temporal and spatial gait characteristics for unilateral amputation. The ultimate aim of this study was to characterise the functional outcome of the individual with transfemoral lower limb amputation fitted with osseointegrated fixation, which can be assess through temporal and spatial gait characteristics.
Resumo:
The prosthetic benefits of osseointegrated fixation for individuals with limb loss, particularly those with transfemoral amputation (TFA), have been clearly demonstrated in the literature. However, very little information is currently available to established how this prosthetic benefits are translated into functional outcomes and, more precisely, walking abilities [1-3]. The ultimate aim of this presentation was to explore how walking abilities of a TFA fitted with an OPRA fixation could be assess through typical temporal and spatial gait characteristics[2].
Resumo:
The monitoring of the actual activities of daily living of individuals with lower limb amputation is essential for an evidence-based fitting of the prosthesis, more particularly the choice of components (e.g., knees, ankles, feet)[1-4]. The purpose of this presentation was to give an overview of the categorization of the load regime data to assess the functional output and usage of the prosthesis of lower limb amputees has presented in several publications[5, 6]. The objectives were to present a categorization of load regime and to report the results for a case.
Resumo:
The objectives of this study were (A) to record the inner prosthesis loading during activities of daily living (ADL), (B) to present a set of variables comparing loading data, and (C) to provide an example of characterisation of two prostheses. The load was measured at 200 Hz using a multi-axial transducer mounted between the residuum and the knee of an individual with unilateral transfemoral amputation fitted with a bone-anchored prosthesis. The load was measured while using two different prostheses including a mechanically (PRO1) and a microprocessor controlled (PRO2) knee during six ADL. The characterisation of prosthesis was achieved using a set of variables split into four categories, including temporal characteristics, maximum loading, loading slopes and impulse. Approximately 360 gait cycles were analysed for each prosthesis. PRO1 showed a cadence improved by 19% and 7%, a maximum force on the long axis reduced by 11% and 19%, as well as an impulse reduced by 32% and 15% during descent of incline and stairs compared to PRO2, respectively. This work confirmed that the proposed apparatus and characterisation can reveal how changes of prosthetic components are translated into inner loading.
Resumo:
Study Design: Comparative analysis Background: Calculations of lower limbs kinetics are limited by floor-mounted force-plates. Objectives: Comparison of hip joint moments, power and mechanical work on the prosthetic limb of a transfemoral amputee calculated by inverse dynamics using either the ground reactions (force-plates) or knee reactions (transducer). Methods: Kinematics, ground reactions and knee reactions were collected using a motion analysis system, two force-plates and a multi-axial transducer mounted below the socket, respectively. Results: The inverse dynamics using ground reactions under-estimated the peaks of hip energy generation and absorption occurring at 63 % and 76 % of the gait cycle (GC) by 28 % and 54 %, respectively. This method over-estimated a phase of negative work at the hip (from 37 %GC to 56 %GC) by 24%. It under-estimated the phases of positive (from 57 %GC to 72 %GC) and negative (from 73 %GC to 98 %GC) work at the hip by 11 % and 58%, respectively. Conclusions: A transducer mounted within the prosthesis has the capacity to provide more realistic kinetics of the prosthetic limb because it enables assessment of multiple consecutive steps and a wide range of activities without issues of foot placement on force-plates. CLINICAL RELEVANCE The hip is the only joint that an amputee controls directly to set in motion the prosthesis. Hip joint kinetics are associated with joint degeneration, low back pain, risks of fall, etc. Therefore, realistic assessment of hip kinetics over multiple gait cycles and a wide range of activities is essential.
Resumo:
This study aimed at presenting the intra-tester reliability of the static load bearing exercises (LBEs) performed by individuals with transfemoral amputation (TFA) fitted with an osseointegrated implant to stimulate the bone remodelling process. There is a need for a better understanding of the implementation of these exercises particularly the reliability. The intra-tester reliability is discussed with a particular emphasis on inter-load prescribed, inter-axis and inter-component reliabilities as well as the effect of body weight normalisation. Eleven unilateral TFAs fitted with an OPRA implant performed five trials in four loading conditions. The forces and moments on the three axes of the implant were measured directly with an instrumented pylon including a six-channel transducer. Reliability of loading variables was assessed using intraclass correlation coefficients (ICCs) and percentage standard error of measurement values (%SEMs). The ICCs of all variables were above 0.9 and the %SEM values ranged between 0 and 87%. This study showed a high between-participants’ variance highlighting the lack of loading consistency typical of symptomatic population as well as a high reliability between the loading sessions indicating a plausible correct repetition of the LBE by the participants. However, these outcomes must be understood within the framework of the proposed experimental protocol.
Resumo:
The consequences of falls are often dreadful for individuals with lower limb amputation using bone-anchored prosthesis.[1-5] Typically, the impact on the fixation is responsible for bending the intercutaneous piece that could lead to a complete breakage over time. .[3, 5-8] The surgical replacement of this piece is possible but complex and expensive. Clearly, there is a need for solid data enabling an evidence-based design of protective devices limiting impact forces and torsion applied during a fall. The impact on the fixation during an actual fall is obviously difficult to record during a scientific experiment.[6, 8-13] Consequently, Schwartze and colleagues opted for one of the next best options science has to offer: simulation with an able-bodied participant. They recorded body movements and knee impacts on the floor while mimicking several plausible falling scenarios. Then, they calculated the forces and moments that would be applied at four levels along the femur corresponding to amputation heights.[6, 8-11, 14-25] The overall forces applied during the falls were similar regardless of the amputation height indicating that the impact forces were simply translated along the femur. As expected, they showed that overall moments generally increased with amputation height due to changes in lever arm. This work demonstrates that devices preventing only against force overload do not require considering amputation height while those protecting against bending moments should. Another significant contribution is to provide, for the time, the magnitude of the impact load during different falls. This loading range is crucial to the overall design and, more precisely, the triggering threshold of protective devices. Unfortunately, the analysis of only a single able-bodied participant replicating falls limits greatly the generalisation of the findings. Nonetheless, this case study is an important milestone contributing to a better understanding of load impact during a fall. This new knowledge will improve the treatment, the safe ambulation and, ultimately, the quality of life of individuals fitted with bone-anchored prosthesis.
Resumo:
Most of socket related discomforts leading to a significant decrease in quality of life of individuals with limb amputation can be overcome by surgical techniques enabling bone-anchored prostheses. To date, the OPRA two-stage procedure (i.e., S1, S2) is the most acknowledged treatment. However, surgical implantations of osseointegrated fixations are developing at an unprecedented pace worldwide.[1-18] Clearly, this option is becoming accessible to a wide range of individuals with limb amputations. The team led by Dr Rickard Branemark has published a number of landmark articles each focusing on a particular aspect (e.g., health related quality of life, functional outcomes, bone remodelling, infection rate). [1-3, 19-32] However, evidences presented in this prospective study are remarkable. Functional outcome, health-related quality of life and complications were considered concurrently for a large population (i.e., 51 participants) over an extended period of time (i.e., up to year follow up). Therefore, the “gain” and “pain” of the whole procedure were truly contrasted for the first time. The results confirmed that OPRA surgical and rehabilitation procedures improved significantly prosthetic use, mobility, global situation and fewer problems. Furthermore, the authors reported 47 episodes of infections for 63% (32) participants between post-op S1 and two years follow up. A total of 87% (41) were superficial infections recorded for 28 participants between post-op S2 and two years follow up, while 13% (6) were deep infections occurring for 4 participants during post-op S1 and S2. As expected, post-op S2 phase was the most prone to both infections. More importantly, the vast majority of infections were effectively treated with oral antibiotics. Clearly, this study provided definitive evidence that the benefits of OPRA fixation overcome complications. This article is also establishing reporting standards and benchmark data for future studies focusing on bone-anchored prostheses.
Resumo:
Surgical implantations of osseointegrated fixations for bone-anchored prosthesis are developing at an unprecedented pace worldwide while initial skepticism in the orthopedic community is slowly fading away. Clearly, this option is becoming accessible to a wide range of individuals with limb loss. [1-18] The team led by Dr Rickard Branemark has previously published a number of landmark articles focusing on the benefits and safety of the OPRA fixation mainly for individual with lower limb loss, particularly those with transfemoral amputation. [1-3, 19-32] However, similar information is lacking for those with upper limb amputation. This team is once again taking a leading role by sharing a retrospective study focusing on the implant survival, adverse events, implant stability, and bone remodelling for 18 individuals with transhumeral amputation over a 5-year post-operative period. Therefore, a comprehensive analysis of the safety of the procedure is accessible for the first time. In essence, the results showed an implant survival rate of 83% and 80% at 2 and 5 year follow ups, respectively. The most frequent adverse events were superficial skin infections that occurred for 28% (5) participants while the least frequent was deep bone infection that happened only once. More importantly, 38% of complications due to infections were effectively managed with nonoperative treatments (e.g., revision of skin penetration site, local cleaning, antibiotics, restriction of soft tissue mobility). Implant stability and bone remodelling were satisfactory. Clearly, this study provided better understanding of the safety of the OPRA surgical and rehabilitation procedure for individuals with upper limb amputation while establishing standards and benchmark data for future studies. However, strong evidences of the benefits are yet to be demonstrated. However, increase in health related quality of life and functional outcomes (e.g., range of movement) are likely. Altogether, the team of authors are providing further evidence that bone-anchored attachment is definitely a promising alternative to socket prostheses.
Resumo:
The demand for an evidence-based clinical practice involving lower limb amputees is increasing. Some of the critical care decisions are related to the loading applied on the residuum partially responsible for comfort and functional outcome. This loading can be assessed using inverse dynamics equations. Typically, this method requires a gait laboratory (e.g., 3D motion analysis system, force-plates). It is mainly suited for the analysis only few steps of walking while being expensive and labour intensive. However, recent scientific and industrial developments demonstrated that discrete and light portable sensors can be placed within the prosthesis to measure accurately the loading during an unlimited number of steps and activities of daily living. Several studies indicated that method based on direct measurements might provide more realistic results. Furthermore, it is a user-friendly method more accessible to clinicians, such as prosthetists. The purpose of this symposium will be to give an overview of these additional opportunities for clinicians to obtain relevant data for evidence-based practice. The three main aims will be: • To present some of the equipment used for direct measurements, • To propose ways to analyse some key data sets, • To give some practical example of data sets for transtibial and transfemoral amputees.
Resumo:
This symposium will provide hand-on update on the current development of the load sensors measuring the inner prosthetic loading that can strongly contribute the ever increasing demand for evidence-based clinical practice. Surgical implantations of osseointegrated fixations for bone-anchored prosthesis are developing at an unprecedented pace worldwide (e.g., Australia, UK, Sweden, US). This option is becoming accessible to a wide range of individuals with limb loss. With these new developments come new potential challenges and opportunities for all the stakeholders involved in the prosthetic care of these patients. Clearly, there is a need for those stakeholders, particularly those attending the ISPO, to be informed of the current and upcoming international developments in bone-anchored prostheses. The objectives of this symposium will be: • To present an overview of the current growth of the procedures worldwide (e.g., identification of key players, centers of activities, growth trend) with a strong focus on the introduction of the framework to evaluate the availability of the procedure at national level (e.g., number of patients treated, range of the levels of implantation, number of commercial fixations accessible), • To provide first-hand updates on the latest cutting-edge scientific and clinical developments of fixations and rehabilitations programs (e.g., Innovative design of implant, cost-effectiveness, long-terms rehabilitation outcomes for screw-type fixation, current developments in US, comparative analysis for press-fit type of implant, potential moves toward single-stage surgeries).
Resumo:
Individuals with limb amputation fitted with conventional socket-suspended prostheses often experience socket related discomfort leading to a significant decrease in quality of life.[1-14] Most of these concerns can be overcome with osseointegration, a direct skeletal fixation method where the prosthetic componentry are directly attached to the fixation, resulting in the redundancy of the traditional socket system. There are two stages of osseointegration; Stage one, a titanium implant is inserted into the marrow space of residual limb bone and Stage two, a titanium extension is attached to the fixture. This surgical procedure is currently blooming worldwide, particularly within Queensland. Whilst providing improvements in quality of life, this new method also has potential to minimise the cost required for an amputee to ambulate during daily living. Thus, the aim of this project was to compare the differences in mean cost of services, cost of componentry and labour hours when using osseointegration compared to traditional socket-based prostheses. Data were extracted from Queensland Artificial Limb Services (QALS) database to determine cost of services, type of services and labour hours required to maintain a prosthetic limb. Five trans-femoral amputee male participants (age 46.4±10.1 yrs; height 175.4±16.3 cm; mass 83.8±14.0 kg; time since second stage 22.0± 8.1 mths) met inclusion criteria which was patient had to be more than 12 months post stage two osseointegration procedure. The socket and osseointegration prosthesis variables examined were the mean hours of labour, mean cost of services and mean cost of prosthetic componentry. Statistical analyses were conducted using an ANOVA. The results identified that there were only significant differences in the number of labour hours (p = 0.005) and cost of services (p = 0.021) when comparing the socket and osseointegration prosthetic type. These results identified that the cost of componentry were comparable between the two methods.
Resumo:
Background To date bone-anchored prostheses are used to alleviate the concerns caused by socket suspended prostheses and to improve the quality of life of transfemoral amputees (TFA). Currently, two implants are commercially available (i.e., OPRA (Integrum AB, Sweden), ILP (Orthodynamics GmbH, Germany)). [1-17]The success of the OPRA technique is codetermined by the rehabilitation program. TFA fitted with an osseointegrated implant perform progressive mechanical loading (i.e. static load bearing exercises (LBE)) to facilitate bone remodelling around the implant.[18, 19] Aim This study investigated the trustworthiness of monitoring the load prescribed (LP) during experimental static LBEs using the vertical force provided by a mechanical bathroom scale that is considered a surrogate of the actual load applied. Method Eleven unilateral TFAs fitted with an OPRA implant performed five trials in four loading conditions. The forces and moments on the three axes of the implant were measured directly with an instrumented pylon including a six-channel transducer. The “axial” and “vectorial” comparisons corresponding to the difference between the force applied on the long axis of the fixation and LP as well as the resultant of the three components of the load applied and LP, respectively were analysed Results For each loading condition, Wilcoxon One-Sample Signed Rank Tests were used to investigate if significant differences (p<0.05) could be demonstrated between the force applied on the long axis and LP, and between the resultant of the force and LP. The results demonstrated that the raw axial and vectorial differences were significantly different from zero in all conditions (p<0.05), except for the vectorial difference for the 40 kg loading condition (p=0.182). The raw axial difference was negative for all the participants in every loading condition, except for TFA03 in the 10 kg condition (11.17 N). Discussion & Conclusion This study showed a significant lack of axial compliance. The load applied on the long axis was significantly smaller than LP in every loading condition. This led to a systematic underloading of the long axis of the implant during the proposed experimental LBE. Monitoring the vertical force might be only partially reflective of the actual load applied, particularly on the long axis of the implant.
Resumo:
Background Individuals with limb amputation fitted with conventional socket-suspended prostheses often experience socket related discomfort leading to a significant decrease in quality of life. Most of these concerns can be overcome by surgical techniques enabling bone-anchored prostheses. In this case, the prosthesis is attached directly to the residual skeleton through a percutaneous implant (e.g., screw type fixation, press-fit implant).[46, 48, 51, 52, 77, 78] The aim of this study is to present the current advances in these surgical techniques worldwide with a strong focus on the current challenges. Methods The current advances will be extracted from a systematic literature review including approximately 40 articles. The outcomes measured will include the estimation of the population worldwide as well as the complications (e.g., infection, loosening, fractures, and breakage) and the benefits (e.g., functional outcomes, health-related quality of life).[5-19, 51-53, 55, 57, 58, 62, 73, 79] Results The population of individuals fitted with a bone-anchored prosthesis is approximately 550 worldwide. Publications focusing on infection are sparse. However, the rate of superficial infection is estimated at 20%. Deep infection occurs rarely. Loosening and peri-prosthetic fractures are fairly uncommon. Breakage of implant parts occurs regularly mainly due to fall. All studies reported a significant improvement in functional level and overall quality of life. Conclusions Several commercial implants are in developments in Europe and US. The number of procedures is consistently growing worldwide. This technique might be primary way to fit a prosthesis to young and active amputees by 2025.
Resumo:
Background Individuals with limb amputation fitted with conventional socket-suspended prostheses often experience socket related discomfort leading to a significant decrease in quality of life. Most of these concerns can be overcome by surgical techniques enabling bone-anchored prostheses. In this case, the prosthesis is attached directly to the residual skeleton through a percutaneous implant (e.g., screw type fixation, press-fit implant).[46, 48, 51, 52, 77, 78] The aim of this study is to present the current advances in these surgical techniques worldwide with a strong focus on the current challenges. Methods The current advances will be extracted from a systematic literature review including approximately 40 articles. The outcomes measured will include the estimation of the population worldwide as well as the complications (e.g., infection, loosening, fractures, and breakage) and the benefits (e.g., functional outcomes, health-related quality of life).[5-19, 51-53, 55, 57, 58, 62, 73, 79] Results The population of individuals fitted with a bone-anchored prosthesis is approximately 550 worldwide. Publications focusing on infection are sparse. However, the rate of superficial infection is estimated at 20%. Deep infection occurs rarely. Loosening and peri-prosthetic fractures are fairly uncommon. Breakage of implant parts occurs regularly mainly due to fall. All studies reported a significant improvement in functional level and overall quality of life. Conclusions Several commercial implants are in developments in Europe and US. The number of procedures is consistently growing worldwide. This technique might be primary way to fit a prosthesis to young and active amputees by 2025.