952 resultados para pulse measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compared the extent and origin of muscle fatigue induced by short-pulse-low-frequency [conventional (CONV)] and wide-pulse-high-frequency (WPHF) neuromuscular electrical stimulation. We expected CONV contractions to mainly originate from depolarization of axonal terminal branches (spatially determined muscle fiber recruitment) and WPHF contractions to be partly produced via a central pathway (motor unit recruitment according to size principle). Greater neuromuscular fatigue was, therefore, expected following CONV compared with WPHF. Fourteen healthy subjects underwent 20 WPHF (1 ms-100 Hz) and CONV (50 μs-25 Hz) evoked isometric triceps surae contractions (work/rest periods 20:40 s) at an initial target of 10% of maximal voluntary contraction (MVC) force. Force-time integral of the 20 evoked contractions (FTI) was used as main index of muscle fatigue; MVC force loss was also quantified. Central and peripheral fatigue were assessed by voluntary activation level and paired stimulation amplitudes, respectively. FTI in WPHF was significantly lower than in CONV (21,717 ± 11,541 vs. 37,958 ± 9,898 N·s P<0,001). The reductions in MVC force (WPHF: -7.0 ± 2.7%; CONV: -6.2 ± 2.5%; P < 0.01) and paired stimulation amplitude (WPHF: -8.0 ± 4.0%; CONV: -7.4 ± 6.1%; P < 0.001) were similar between conditions, whereas no change was observed for voluntary activation level (P > 0.05). Overall, our results showed a different motor unit recruitment pattern between the two neuromuscular electrical stimulation modalities with a lower FTI indicating greater muscle fatigue for WPHF, possibly limiting the presumed benefits for rehabilitation programs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: : The systolic augmentation index (sAix), calculated from the central aortic pulse wave (reconstructed from the noninvasive recording of the radial pulse with applanation tonometry), is widely used as a simple index of central arterial stiffness, but has the disadvantage of also being influenced by the timing of the reflected with respect to the forward pressure wave, as shown by its inverse dependence on heart rate (HR). During diastole, the central aortic pulse also contains reflected waves, but their relationship to arterial stiffness and HR has not been studied. METHODS: : In 48 men and 45 women, all healthy, with ages ranging from 19 to 70 years, we measured pulse wave velocity (PWV, patients supine), a standard evaluator of arterial stiffness, and carried out radial applanation tonometry (patients sitting and supine). The impact of reflected waves on the diastolic part of the aortic pressure waveform was quantified in the form of a diastolic augmentation index (dAix). RESULTS: : Across ages, sexes, and body position, there was an inverse relationship between the sAix and the dAix. When PWV and HR were added as covariates to a prediction model including age, sex and body position as main factors, the sAix was directly related to PWV (P < 0.0001) and inversely to HR (P < 0.0001). With the same analysis, the dAix was inversely related to PWV (P < 0.0001) and independent of HR (P = 0.52). CONCLUSION: : The dAix has the same degree of linkage to arterial stiffness as the more conventional sAix, while being immune to the confounding effect of HR. The quantification of diastolic aortic pressure augmentation by reflected waves could be a useful adjunct to pulse wave analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUME: L'objectif de cette étude était de déterminer l'impact de la grossesse non compliquée sur l'onde de pouls de la pression aortique centrale. Méthode 66 femmes au total avec une grossesse simple ont été réparties en trois groupes selon le stade de leur gestation: premier trimestre (T1, n=22), deuxième trimestre (T2, n=20) et troisième trimestre (T3, n=24). Le groupe contrôle (C, n=21) était constitué de femmes non enceintes, en bonne santé habituelle, prenant une contraception oestroprogestative. La tonométrie d'aplanation a été utilisée pour l'acquisition des ondes de pouls centrale un appareil disponible dans le commerce (SphygmoCor) permet l'enregistrement de l'onde de pouls périphérique avec un tonomètre d'aplanation de l'artère radiale au niveau du poignet, puis effectue sa transformation en sa forme centrale, grâce à une analyse de Fourrier et une fonction de transfert. L'influence des ondes réfléchies sur l'onde de pouls a été déterminée non seulement pendant la systole (augmentation systolique), comme on procède habituellement dans l'analyse de l'onde de pouls, mais aussi pendant la diastole (augmentation diastolique). Résultats Au cours de la grossesse, les pressions centrales systolique et diastolique sont restées inchangées et comparables aux valeurs mesurées chez les femmes qui ne sont pas enceintes. Dans le groupe contrôle, l'augmentation systolique s'élevait à 8.1±7.5% de la pression de pouls ; il n'y avait pas de différence statistiquement significative avec les valeurs obtenues chez les femmes enceintes, et ce, à n'importe quel stade de la grossesse (T1 : 4.6±11.4%, T2: 5.0±9.3%, T3 : 4.7±8.1%). Par contre, l'amplitude de l'augmentation diastolique diminuait avec la progression de la grossesse (C 6.5±2.4%, T1 : 5.2±3.1%, T2 : 3.8±2.6%; P=0.002 versus C; T3 : 2.3±2.0%; P<0.0001 versus C et P=0.004 versus T 1). Conclusion La grossesse ne modifie pas la forme de l'onde de pouls systolique centrale, ce qui implique de la part du système cardiovasculaire une adaptation fine à la demande croissante de flux sanguin, et ce, à tous les stades de la grossesse. Par contre, l'amplitude de l'onde de réflexion atteignant l'aorte pendant la diastole diminue progressivement au cours de la grossesse. Perspectives De récentes études montrent qu'une valeur anormalement haute de l'augmentation systolique de la pression centrale, comme on peut la déterminer avec la tonométrie d'aplanation, pourrait être un indice de trouble hypertensif de la grossesse débutant. Cette technique simple pourrait être d'autant plus facile à mettre en oeuvre si les valeurs normales pour l'augmentation systolique étaient indépendantes du stade de la grossesse, comme le suggèrent nos résultats, du moins pour les mesures prises en position assise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). METHODS: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. RESULTS: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. CONCLUSION: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universal standard goniometer is an essential tool to measure articulations' range of motion (ROM). In this time of technological advances and increasing use of smartphones, new measurement's tools appear as specific smartphone applications. This article compares the iOS application "Knee Goniometer" with universal standard goniometer to assess knee ROM. To our knowledge, this is the first study that uses a goniometer application in a clinical context. The purpose of this study is to determine if this application could be used in clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper explores biases in the elicitation of utilities under risk and the contribution that generalizations of expected utility can make to the resolution of these biases. We used five methods to measure utilities under risk and found clear violations of expected utility. Of the theories studies, prospect theory was most consistent with our data. The main improvement of prospect theory over expected utility was in comparisons between a riskless and a risky prospect(riskless-risk methods). We observed no improvement over expected utility in comparisons between two risky prospects (risk-risk methods). An explanation why we found no improvement of prospect theory over expected utility in risk-risk methods may be that there was less overweighting of small probabilities in our study than has commonly been observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method of measuring joint angle using a combination of accelerometers and gyroscopes is presented. The method proposes a minimal sensor configuration with one sensor module mounted on each segment. The model is based on estimating the acceleration of the joint center of rotation by placing a pair of virtual sensors on the adjacent segments at the center of rotation. In the proposed technique, joint angles are found without the need for integration, so absolute angles can be obtained which are free from any source of drift. The model considers anatomical aspects and is personalized for each subject prior to each measurement. The method was validated by measuring knee flexion-extension angles of eight subjects, walking at three different speeds, and comparing the results with a reference motion measurement system. The results are very close to those of the reference system presenting very small errors (rms = 1.3, mean = 0.2, SD = 1.1 deg) and excellent correlation coefficients (0.997). The algorithm is able to provide joint angles in real-time, and ready for use in gait analysis. Technically, the system is portable, easily mountable, and can be used for long term monitoring without hindrance to natural activities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method to evaluate cyclical models not requiring knowledge of the DGP and the exact specificationof the aggregate decision rules is proposed. We derive robust restrictions in a class of models; use someto identify structural shocks in the data and others to evaluate the class or contrast sub-models. Theapproach has good properties, even in small samples, and when the class of models is misspecified. Themethod is used to sort out the relevance of a certain friction (the presence of rule-of-thumb consumers)in a standard class of models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Organizations often face the challenge of communicating their strategiesto local decision makers. The difficulty presents itself in finding away to measure performance wich meaningfully conveys how to implement theorganization's strategy at local levels. I show that organizations solvethis communication problem by combining performance measures in such away that performance gains come closest to mimicking value-added asdefined by the organization's strategy. I further show how organizationsrebalance performance measures in response to changes in their strategies.Applications to the design of performance metrics, gaming, and divisionalperformance evaluation are considered. The paper also suggests severalempirical ways to evaluate the practical importance of the communicationrole of measurement systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a method for the measurement of changes in health inequality and income-related health inequality over time in a population.For pure health inequality (as measured by the Gini coefficient) andincome-related health inequality (as measured by the concentration index),we show how measures derived from longitudinal data can be related tocross section Gini and concentration indices that have been typicallyreported in the literature to date, along with measures of health mobilityinspired by the literature on income mobility. We also show how thesemeasures of mobility can be usefully decomposed into the contributions ofdifferent covariates. We apply these methods to investigate the degree ofincome-related mobility in the GHQ measure of psychological well-being inthe first nine waves of the British Household Panel Survey (BHPS). Thisreveals that dynamics increase the absolute value of the concentrationindex of GHQ on income by 10%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We represent interval ordered homothetic preferences with a quantitative homothetic utility function and a multiplicative bias. When preferences are weakly ordered (i.e. when indifference is transitive), such a bias equals 1. When indifference is intransitive, the biasing factor is a positive function smaller than 1 and measures a threshold of indifference. We show that the bias is constant if and only if preferences are semiordered, and we identify conditions ensuring a linear utility function. We illustrate our approach with indifference sets on a two dimensional commodity space.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A previous study has shown the possibility to identify methane (CH4 ) using headspace-GC-MS and quantify it with a stable isotope as internal standard. The main drawback of the GC-MS methods discussed in literature for CH4 measurement is the absence of a specific internal standard necessary to perform quantification. However, it becomes essential to develop a safer method to limit the manipulation of gaseous CH4 and to precisely control the injected amount of gas for spiking and calibration by comparison with external calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate a labeled gas as an internal standard in a vial on the basis of the formation of CH4 by the reaction of Grignard reagent methylmagnesium chloride with deuterated water. This method allows precise measurement of CH4 concentrations in gaseous sample as well as in a solid or a liquid sample after a thermodesorption step in a headspace vial. A full accuracy profile validation of this method is then presented.