995 resultados para poultry litter quality
Resumo:
A descriptive study was developed in order to assess air contamination caused by fungi and particles in seven poultry units. Twenty seven air samples of 25 litters were collected through impaction method. Air sampling and particle concentration measurement were performed in the pavilions’ interior and also outside premises, since this was the place regarded as reference. Simultaneously, temperature and relative humidity were also registered. Regarding fungal load in the air from the seven poultry farms, the highest value obtained was 24040 CFU/m3 and the lowest was 320 CFU/m3. Twenty eight species/genera of fungi were identified, being Scopulariopsis brevicaulis (39.0%) the most commonly isolated species and Rhizopus sp. (30.0%) the most commonly isolated genus. From the Aspergillus genus, Aspergillus flavus (74.5%) was the most frequently detected species. There was a significant correlation (r=0.487; p=0.014) between temperature and the level of fungal contamination (CFU/m3). Considering contamination caused by particles, in this study, particles with larger dimensions (PM5.0 and PM10) have higher concentrations. There was also a significant correlation between relative humidity and concentration of smaller particles namely, PM0.5 (r=0.438; p=0.025) and PM1.0 (r=0.537; p=0.005). Characterizing typical exposure levels to these contaminants in this specific occupational setting is required to allow a more detailed risk assessment analysis and to set exposure limits to protect workers’ health.
Resumo:
We investigate whether firms’ economic and financial situation influence the Quality of their Financial Reports (FRQ). FRQ is fundamental for investors and it affects the international capital movements [Bradshaw et al. (2004)] and Gelos and Wei (2005)]. Following Schipper and Vicent (2003) we use two issues to access earnings quality: abnormal accruals and earnings persistence. For seventeen European countries, we find evidence that the economic performance affects FRQ. Big firms and those with high current earnings exhibit better financial information. These results are robust since they don’t depend on FRQ proxy and we have the same evidence when we estimate regression with economical and financial factors separately or together. About financial situation, it seems not to affect FRQ. However, in high leveraged firms, the capital structure becomes determinant.
Resumo:
A descriptive study was developed in order to compare indoor and outdoor air contamination caused by fungi and particles in seven poultry units. Twenty eight air samples of 25 litters were collected through the impaction method on malt extract agar. Air sampling and particles concentration measurement were done in the interior and also outside premises of the poultries’ pavilions. Regarding the fungal load in the air, indoor concentration of mold was higher than outside air in six poultry units. Twenty eight species / genera of fungi were identified indoor, being Scopulariopsis brevicaulis (40.5%) the most commonly isolated species and Rhizopus sp. (30.0%) the most commonly isolated genus. Concerning outdoor, eighteen species/genera of fungi were isolated, being Scopulariopsis brevicaulis (62.6%) also the most isolated. All the poultry farms analyzed presented indoor fungi different from the ones identified outdoors. Regarding particles’ contamination, PM2.5, PM5.0 and PM10 had a statistically significant difference (Mann-Whitney U test) between the inside and outside of the pavilions, with the inside more contaminated (p=.006; p=.005; p=.005, respectively). The analyzed poultry units are potential reservoirs of substantial amounts of fungi and particles and could therefore free them in the atmospheric air. The developed study showed that indoor air was more contaminated than outdoors, and this can result in emission of potentially pathogenic fungi and particles via aerosols from poultry units to the environment, which may post a considerable risk to public health and contribute to environmental pollution.
Resumo:
Indoor air quality recently entered legislation in Portugal. Several parameters must be evaluated and kept within limits in order to obtain a certification for air quality and energy consumption. Certification parameters were analyzed in two Portuguese archives in order to assess indoor air quality both for people attending or working on these premises and for maintenance of a written heritage that must be retained for future generations. Carbon monoxide (CO) and carbon dioxide (CO2), formaldehyde, and fungal counts were kept within stipulated limits. Relative humidity (RH), volatile organic compounds (VOC), particulate matter (PM10), and ozone (O3) showed values above legislated levels and justified the implementation of corrective measures. In terms of conservation, studies on the limit values are still needed, but according to the available international guidelines, some of the analyzed parameters such as PM10, O3, and RH were also above desirable values. Corrective measures were proposed to these institutions. Although this study was only of a short duration, it proved valuable in assessing potential eventual problems and constitutes the first Portuguese indoor air quality assessment taking into consideration both aspects of an archive such as human health and heritage safekeeping.
Resumo:
Although a great body of literature exists concerning the ingestion of food contaminated with aflatoxin, there are still few studies regarding mycotoxin inhalation in occupational settings. Since mycotoxins are relatively non-volatile, inhalation exposure is cause by inhalation of airborne fungal particulates or fungi-contaminated substrates that contain aflatoxin. We intend to know if there is occupational exposure to aflatoxin in Portuguese poultry and swine production. A total of 19 individuals (11 swine; 8 poultry) agreed and provided blood samples during the course of this investigation. Measurement of AFB1 was performed by ELISA. The samples were treated with pronase (Merck), wash in a Column C18 and purification was made with immunoaffinity columns (R.biopharma), specific for AFB1. It was applied statistical test (Mann-Whitney) to verified statistical difference in AFB1 results between the two settings. Results varied with concentrations from
Resumo:
OBJECTIVE: To assess the impact of town planning, infrastructure, sanitation and rainfall on the bacteriological quality of domestic water supplies. METHODS: Water samples obtained from deep and shallow wells, boreholes and public taps were cultured to determine the most probable number of Escherichia coli and total coliform using the multiple tube technique. Presence of enteric pathogens was detected using selective and differential media. Samples were collected during both periods of heavy and low rainfall and from municipalities that are unique with respect to infrastructure planning, town planning and sanitation. RESULTS: Contamination of treated and pipe distributed water was related with distance of the collection point from a utility station. Faults in pipelines increased the rate of contamination (p<0.5) and this occurred mostly in densely populated areas with dilapidated infrastructure. Wastewater from drains was the main source of contamination of pipe-borne water. Shallow wells were more contaminated than deep wells and boreholes and contamination was higher during period of heavy rainfall (p<0.05). E. coli and enteric pathogens were isolated from contaminated supplies. CONCLUSIONS: Poor town planning, dilapidated infrastructure and indiscriminate siting of wells and boreholes contributed to the low bacteriological quality of domestic water supplies. Rainfall accentuated the impact.
Resumo:
This chapter provides a theoretical background about image quality in diagnostic radiology. Digital image representation and also image quality evaluation methods are here discussed. An overview of methods for quality evaluation of diagnostic imaging procedures is provided. Digital image representation and primary physical image quality parameters are also discussed, including objective image quality measurements and observer performance methods.
Resumo:
OBJECTIVE: To evaluate the microbiological quality of treated and untreated water samples came from urban and rural communities and to examine the relationship between coliforms occurrence and average water temperature, and a comparison of the rainfall levels. METHODS: A sample of 3,073 untreated and treated (chlorinated) water from taps (1,594), reservoir used to store treated water (1,033), spring water (96) and private well (350) collected for routine testing between 1996 and 1999 was analyzed by the multiple dilution tube methods used to detect the most probable number of total and fecal coliforms. These samples were obtained in the region of Maringá, state of Paraná, Brazil. RESULTS: The highest numbers water samples contaminated by TC (83%) and FC (48%) were found in the untreated water. TC and FC in samples taken from reservoirs used to store treated water was higher than that from taps midway along distribution lines. Among the treated water samples examined, coliform bacteria were found in 171 of the 1,033 sampling reservoirs. CONCLUSIONS: Insufficient treatment or regrowth is suggested by the observation that more than 17% of these treated potable water contained coliform. TC and FC positive samples appear to be similar and seasonally influenced in treated water. Two different periods must be considered for the occurrence of both TC and FC positive samples: (i) a warm-weather period (September-March) with high percentage of contaminated samples; and (ii) cold-weather period (April-August) were they are lower. Both TC and TF positive samples declined with the decreased of water temperature.
Resumo:
The objective of this research is to investigate the role of the relationship quality, cooperation and culture between Portuguese companies and their export market intermediaries in Angola. In particular, we aim to understand the importance that the quality of the relationship has in cooperation and the role of cultures in export activities. An important aspect of this study is precisely the fact that it includes an African country, where, in terms of the literature, there is a strong lack of studies. In terms of methodology we opted for qualitative analysis; we present the results of two case studies of Portuguese exporting companies and one case study of Angolan intermediate. In general, the results are that the business relationships are characterized by trust, commitment, cooperation, culture, similar values, as in the past, Angola belonged to Portugal there is easy communication because both countries share the same. Such factors will influence the trade relations between Portuguese exporters and their Angolan distributors.
Resumo:
OBJECTIVE: To investigate the quality of life, life satisfaction, happiness and demands of work in workers with different work schedules. METHODS: The survey was carried out on professional workers in social care. Some were shiftworkers whose schedule included night shifts (N=311), some were shiftworkers without night shifts (N=207) and some were non-shiftworkers (N=1,210). Surveys were mailed and the response rate was 86%. For the purpose of this study several variables were selected from the Survey: The Quality of Life Profile, which measures importance, satisfaction, control and opportunities in nine domains of life plus measures of happiness, life satisfaction and demands of work. RESULTS: While both groups of shiftworkers, compared to non-shiftworkers, reported needing more physical effort to complete their work, and reported 'being' more physically tired, no differences were found in reports of overall happiness, life satisfaction or total quality of life. However, night-shiftworkers reported greater percentage of time unhappy than the other two groups of workers. In analyses of the quality of life, night-shiftworkers were less satisfied with domains of spiritual 'being' and physical and community 'belonging' than day-shiftworkers and non-shiftworkers. They also reported having fewer opportunities to improve their physical 'being', leisure, and personal growth than the other two groups. CONCLUSIONS: Quality of life in specific domains in night-shiftworkers was rated worse than in other groups of workers. Domain-based quality of life assessment gives more information regarding the particular needs of workers than overall or global measures of well-being.
Resumo:
Farmers are occupationally exposed to many respiratory hazards at work and display higher rates of asthma and respiratory symptoms than other workers. Dust is one of the components present in poultry production that increases risk of adverse respiratory disease occurrence. Dust originates from poultry residues, molds, and feathers and is biologically active as it contains microorganisms. Exposure to dust is known to produce a variety of clinical responses, including asthma, chronic bronchitis, chronic airways obstructive disease (COPD), allergic alveolitis, and organic dust toxic syndrome (ODTS). A study was developed to determine particle contamination in seven poultry farms and correlate this with prevalence rate of respiratory defects and record by means of a questionnaire the presence of clinical symptoms associated with asthma and other allergy diseases by European Community Respiratory Health Survey. Poultry farm dust contamination was found to contain higher concentrations of particulate matter (PM) PM5 and PM10. Prevalence rate of obstructive pulmonary disorders was higher in individuals with longer exposure regardless of smoking status. In addition, a high prevalence for asthmatic (42.5%) and nasal (51.1%) symptoms was noted in poultry workers. Data thus show that poultry farm workers are more prone to suffer from respiratory ailments and this may be attributed to higher concentrations of PM found in the dust. Intervention programs aimed at reducing exposure to dust will ameliorate occupational working conditions and enhance the health of workers.
Resumo:
Myocardial perfusion-gated-SPECT (MP-gated-SPECT) imaging often shows radiotracer uptake in abdominal organs. This accumulation interferes frequently with qualitative and quantitative assessment of the infero-septal region of myocardium. The objective of this study is to evaluate the effect of ingestion of different fat content on the reduction of extra-myocardial uptake and to improve MP-gated-SPECT image quality. In this study, 150 patients (65 ^ 18 years) who were referred for MP-gated-SPECT underwent a 1-day-protocol including imaging after stress (physical or pharmacological) and resting conditions. All patients gave written informed consent. Patients were subdivided into five groups: GI, GII, GIII, GIV and GV. In the first four groups, patients ate two chocolate bars with different fat content. Patients in GV – control group (CG) – had just water. Uptake indices (UI) of myocardium (M)/liver(L) and M/stomach–proximal bowel(S) revealed lower UI of M/S at rest in all groups. Both stress and rest studies using different food intake indicate that patients who ate chocolate with different fat content showed better UI of M/L than the CG. The UI of M/L and M/S of groups obtained under physical stress are clearly superior to that of groups obtained under pharmacological stress. These differences are only significant in patients who ate high-fat chocolate or drank water. The analysis of all stress studies together (GI, GII, GIII and GIV) in comparison with CG shows higher mean ranks of UI of M/L for those who ate high-fat chocolate. After pharmacological stress, the mean ranks of UI of M/L were higher for patients who ate high- and low-fat chocolate. In conclusion, eating food with fat content after radiotracer injection increases, respectively, the UI of M/L after stress and rest in MP-gated-SPECT studies. It is, therefore, recommended that patients eat a chocolate bar after radiotracer injection and before image acquisition.
Resumo:
Aspergillus is among a growing list of allergens that aggravate asthmatic responses. Significant pulmonary pathology is associated with Aspergillus-induced allergic and asthmatic lung disease. Environments with high levels of exposure to fungi are found in animal production facilities such as for swine and poultry, and farmers working with these are at increased risk for occupational respiratory diseases. Seven Portuguese poultry and seven swine farms were analyzed in order to estimate the prevalence, amount, and distribution of Aspergillus species, as well as to determine the presence of clinical symptoms associated with asthma and other allergy diseases in these highly contaminated settings. From the collected fungal isolates (699), an average incidence of 22% Aspergillus was detected in poultry farms, while the prevalence at swine farms was 14%. The most frequently isolated Aspergillus species were A. versicolor, A. flavus, and A. fumigatus. In poultry farms, A. flavus presented the highest level of airborne spores (>2000 CFU/m3), whereas in swine farms the highest was A. versicolor, with an incidence fourfold greater higher than the other mentioned species. Eighty workers in these settings were analyzed, ranging in age from 17 to 93 yr. The potentially hazardous exposure of poultry workers to mold allergens using sensitization markers was evaluated. Although no significant positive association was found between fungal contamination and sensitization to fungal antigens, a high incidence of respiratory symptoms in professionals without asthma was observed, namely, wheezing associated with dyspnea (23.8%) and dyspnea after strenuous activities (12.3%), suggesting underdiagnosed respiratory disturbances. Further, 32.5% of all exposed workers noted an improvement of respiratory ability during resting and holidays. From all the analyzed workers, seven were previously diagnosed with asthma and four reported the first attack after the age of 40 yr, which may be associated with their occupational exposure. Some of the fungi, namely, the Aspergillus species detected in this study, are known to induce hypersensitivity reactions in humans. This study confirmed the presence and distribution of Aspergillus in Portuguese poultry and swine farms, suggesting a possible occupational health problem and raising the need for preventive and protective measures to apply to avoid exposure in both occupational settings.
Resumo:
Exposure to certain fungi (molds) can cause human illness by 3 specific mechanisms: generation of a harmful immune response, direct infection by the organism or/and toxic-irritant effects from mold byproducts. Moulds are considered central elements in daily exposure of poultry workers and can be the cause of an increased risk of occupational respiratory diseases, like allergic and non-allergic rhinitis and asthma.
Resumo:
Animal confinement tends to increase the overall microbial load in the production environment caused by high amounts of feed and organic residuals (manure and wastewater) present in those environments. The number of animais and the handling and management required to work in these settings also contribute to enhance that microbial ioad. Animal housing typically exposes workers to substantial concentrations of bioaerosols, such as fungi and their metabolites. Therefore, agricultural workers, and especially pig and poultry farmers, are at increased risk of occupational respiratory diseases. Exposure to bioaerosols in poultries and swines may vary depending upon the stage of the animals' growth, density, manure management procedures, litter type and used floor coverage, among others. Gathering temporal information about the quantity and the composition of fungal load is necessary to better understand the relationship between these factors and adverse health symptoms of workers. This study aimed to characterize and compare fungal contamination between these two different settings.