946 resultados para oily sanitary waste
Resumo:
This study is done to examine waste power plant’s optimal processing chain and it is important to consider from several points of view on why one option is better than the other. This is to insure that the right decision is made. Incineration of waste has devel-oped to be one decent option for waste disposal. There are several legislation matters and technical options to consider when starting up a waste power plant. From the tech-niques pretreatment, burner and flue gas cleaning are the biggest ones to consider. The treatment of incineration residues is important since it can be very harmful for the envi-ronment. The actual energy production from waste is not highly efficient and there are several harmful compounds emitted. Recycling of waste before incineration is not very typical and there are not many recycling options for materials that cannot be easily re-cycled to same product. Life cycle assessment is a good option for studying the envi-ronmental effect of the system. It has four phases that are part of the iterative study process. In this study the case environment is a waste power plant. The modeling of the plant is done with GaBi 6 software and the scope is from gate-to-grave. There are three different scenarios, from which the first and second are compared to each other to reach conclusions. Zero scenario is part of the study to demonstrate situation without the power plant. The power plant in this study is recycling some materials in scenario one and in scenario two even more materials and utilize the bottom ash more ways than one. The model has the substitutive processes for the materials when they are not recycled in the plant. The global warming potential results show that scenario one is the best option. The variable costs that have been considered tell the same result. The conclusion is that the waste power plant should not recycle more and utilize bottom ash in a number of ways. The area is not ready for that kind of utilization and production from recycled materials.
Resumo:
Alfa Laval Aalborg Oy designs and manufactures waste heat recovery systems utilizing extended surfaces. The waste heat recovery boiler considered in this thesis is a water-tube boiler where exhaust gas is used as the convective heat transfer medium and water or steam flowing inside the tubes is subject to cross-flow. This thesis aims to contribute to the design of waste heat recovery boiler unit by developing a numerical model of the H-type finned tube bundle currently used by Alfa Laval Aalborg Oy to evaluate the gas-side heat transfer performance. The main objective is to identify weaknesses and potential areas of development in the current H-type finned tube design. In addition, numerical simulations for a total of 15 cases with varying geometric parameters are conducted to investigate the heat transfer and pressure drop performance dependent on H-type fin geometry. The investigated geometric parameters include fin width and height, fin spacing, and fin thickness. Comparison between single and double tube type configuration is also conducted. Based on the simulation results, the local heat transfer and flow behaviour of the H-type finned tube is presented including boundary layer development between the fins, the formation of recirculation zone behind the tubes, and the local variations of flow velocity and temperature within the tube bundle and on the fin surface. Moreover, an evaluation of the effects of various fin parameters on heat transfer and pressure drop performance of H-type finned tube bundle has been provided. It was concluded that from the studied parameters fin spacing and fin width had the most significant effect on tube bundle performance and the effect of fin thickness was the least important. Furthermore, the results suggested that the heat transfer performance would increase due to enhanced turbulence if the current double tube configuration is replaced with single tube configuration, but further investigation and experimental measurements are required in order to validate the results.
Resumo:
The purpose of this study is to evaluate the hygienic-sanitary quality of vegetables and irrigation water and assess the effectiveness of lemon juice and vinegar in reducing E. coli strains inoculated on lettuce. One hundred and forty samples of vegetables and 45 samples of irrigation water were investigated for thermotolerant coliforms and Salmonella spp. In order to verify the effectiveness of natural household sanitizers in reducing E. coli in inoculated lettuce, four treatment solutions were tested: fresh lemon juice, alcohol vinegar, lemon juice-vinegar mixture, and lemon juice-vinegar-water mixture. The microbiological analysis revealed high rates of contamination by thermotolerant coliforms and identified the presence of E. coli in 32% of the tested vegetable samples and 56% of the water samples. While no significant statistical difference (p < 0, 05) was identified in the tested solutions, the treatment with a combination of lemon juice and vinegar resulted in the highest Decimal Reductions (DR) of E. coli O157: H7 while the treatment with vinegar alone was the most effective against the indigenous E. coli strain
Resumo:
This study was carried out to evaluate the antioxidant capacity of the agro-industrial waste from acerola. Hydroacetone, hydroethanolic, and hydromethanolic extracts were obtained using the sequential extraction process, and they were screened for their free radical DPPH (1,1-diphenyl-2-picrilhidrazil) and ABTS+ (2,2'-azino-bis-(3-etilbenzotiazolin 6-sulfonic acid) scavenging activity and their effect on the linoleic acid peroxidation by the ferric thiocyanate method. Soybean oil with the addition of the extracts (200 ppm) was submitted to Schaal oven test (60 °C, 28 days), in which the samples were analyzed for peroxide value and conjugated dienes. Hydroethanolic and hydromethanolic extracts exhibited good DPPH scavenging activity (low value of EC50 and TEC50 and high value of AE), good ABTS scavenging capacity (1445.1 and 1145.5 µMol TEAC.g-1, respectively), and high percentage inhibition of peroxidation of linoleic acid (96.12 and 91.84%, respectively) and showed the ability to retard the formation of peroxides and conjugated dienes.
Resumo:
The aim of this work was to perform the microbiological and physicochemical characterization of surimi made from waste of piramutaba filleting. The results of physicochemical characterization of the waste and surimi were: moisture (76.37 and 79.11%), total lipids (5.35 and 0.74%), proteins (14.92 and 10.79%), ash (3.03 and 2.35%), pH (6.9 and 7.4), caloric value (109.15 and 77.86 kcal.g-1), and water activity (both 0.98), respectively. The results of the levels of total volatile bases were 7.29 mgN/100-1 g (waste) and 7.01% carbohydrate (surimi). The values of total lipids and proteins were reduced during the preparation of surimi, probably due to successive washes during the processing. Waste and surimi were examined microbiologically and are in compliance with required parameters. The results show a loss of red (a* parameter) and yellow (b* parameter) color. On the other hand, the L* parameter (lightness) increased after the processing of surimi. It can be concluded that piramutaba waste can be used for surimi preparation and as a source of nutrients for human consumption, providing an alternative use of these wastes avoiding their disposal polluting the environment.
Resumo:
This study aimed to verify the hygienic-sanitary working practices and to create and implement a Hazard Analysis Critical Control Point (HACCP) in two lobster processing industries in Pernambuco State, Brazil. The industries studied process frozen whole lobsters, frozen whole cooked lobsters, and frozen lobster tails for exportation. The application of the hygienic-sanitary checklist in the industries analyzed achieved conformity rates over 96% to the aspects evaluated. The use of the Hazard Analysis Critical Control Point (HACCP) plan resulted in the detection of two critical control points (CCPs) including the receiving and classification steps in the processing of frozen lobster and frozen lobster tails, and an additional critical control point (CCP) was detected during the cooking step of processing of the whole frozen cooked lobster. The proper implementation of the Hazard Analysis Critical Control Point (HACCP) plan in the lobster processing industries studied proved to be the safest and most cost-effective method to monitor each critical control point (CCP) hazards.
Resumo:
There is a trend towards the use of novel technologies nowadays, mainly focused on biological processes, for recycling and the efficient utilization of organic residues that can be metabolized by different microorganisms as a source of energy. In the present study the isolation of bacterial strains from six different agro-industrial by-products and waste was performed with the objective of evaluating their hydrolytic capacities and suitability for use in bioconversion of specific substrates. The 34 isolated strains were screened in specific culture media for the production of various hydrolytic enzymes (lipase, protease, cellulase, and amylase). It was found that 28 strains exhibited proteolytic activity, 18 had lipolytic activity, 13 had caseinolytic activity, 15 had amylolytic activity, and 11 strains exhibited cellulolytic activity. The strains that showed the highest hydrolytic capacities with biotechnological potential were selected, characterized genotipically, and identified as Bacillus, Serratia, Enterococcus, Klebsiella, Stenotrophomonas, Lactococcus, and Escherichia genera. It was concluded that the strain isolates have a high potential for use in the bioconversion of agro-industrial waste, both as a pure culture and as a microbial consortium.
Resumo:
The objective of this study was to evaluate the hygienic-sanitary conditions of hospital nutrition and dietary services using external and internal auditors. Eleven hospitals were evaluated for their nutrition and dietary services using an evaluation checklist based on food safety requirements in the current legislation. The checklist was applied by an internal auditor (a technical supervisor) and an external auditor (a professional with experience in food services) between August and October 2011. According to the number of items on the evaluation checklist that were considered adequate, the hospital facilities were ranked as excellent, good, regular, bad, or very bad. The results obtained by the auditors were compared. According to these results, it can be said that most of the hospital nutrition and dietary services were rated as good for overall quality by the internal auditor, while the external auditor classified them as Regular. There was a clear difference between the evaluations of the auditors, both in terms of the number of items considered adequate and the overall requirements' average score. It can be concluded that hospital nutrition and dietary services should meet safety requirements in order to provide food. These facilities should have external audits conducted as a way to prevent routine problems from being perpetuated.
Resumo:
Acerola is a fruit that can be consumed in the form of juice and pulp. However, during its processing, a large amount of waste is generated (seed and bagasse). Adding value to these by-products is of great interest, since their use can enrich foods with nutrients and fiber. In this study, we performed phytochemical screening, determined the proximate and mineral composition, bioactive compounds and the technological functional properties of acerola seed flour and acerola bagasse flour. Seeds were dried in a ventilated oven at ± 45 °C and the bagasse was lyophilized. Samples were ground, stored in flasks protected from light. Phytochemical screening revealed metabolites of nutritional and pharmacological interest and no potentially toxic substances in the flours. Seed flour and bagasse flour showed high levels (g 100 g- 1 of dry matter - DM) of soluble fiber: 4.76 and 8.74; insoluble fiber: 75.76 and 28.58, and phenolic compounds: 4.73 and 10.82, respectively. The flours also showed high absorption of water, oil and emulsion stability, presenting potential for inclusion in meat products and bakery products.
Resumo:
Potato pulp waste (PPW) drying was investigated under different experimental conditions (temperatures from 50 to 70 °C and air flow from 0.06 to 0.092 m³ m- 2 s- 1) as a possible way to recover the waste generated by potato chip industries and to select the best-fit model to the experimental results of PPW drying. As a criterion to evaluate the fitting of mathematical models, a method based on the sum of the scores assigned to the four evaluated statistical parameters was used: regression coefficient (R²), relative mean error P (%), root mean square error (RMSE), and reduced chi-square (χ²). The results revealed that temperature and air velocity are important parameters to reduce PPW drying time. The models Midilli and Diffusion had the lowest sum values, i.e., with the best fit to the drying data, satisfactorily representing the drying kinetics of PPW.
Resumo:
The fish industry generates high volume of waste from fish oil that can have the extraction of its lipids used as nutraceuticals and foods. The objective of this study was to produce unsaturated fatty acids from industrialized fish oil by means of a differentiated hydrolysis process. The samples used were crude fish oil obtained from Campestre industry and characterized through physical-chemical parameters, according to AOCS: acidity, peroxide, saponification, iodine and percentage of free fatty acids and also obtained the fatty acid profile through derivatization method for gas chromatography. The results obtained for the oleochemical indices for refined oil were similar to the data found on the literature. The content of polyunsaturated fatty acids (PUFA) was found of 32,78%, with 9,12% of docosahexaenoic (DHA) and 10,36% of eicosapentaenoic (EPA), regarding monounsaturated fatty acids (MUFA) content was of 30,59% in the hydrolyzed fish oil in relation to refined (20,06%). Thus, it can be concluded that the hydrolysis process used for oils from fish-waste was satisfactory on the production of absolute yield of lipids in the process and significant preservation on the percentages of EPA and DHA, interesting on the production of nutraceuticals and nutrition of aquatic animals, including shrimp in captivity.
Resumo:
The objective of this study was to evaluate the applicability of the Petrifilm™ plates to enumerate microbial groups in sheep milk. Samples of sheep milk (n = 30) were plated simultaneously, to enumerate mesophilic aerobes, total coliforms, lactic acid bacteria, Staphylococcus aureus and Escherichia coli, using convencional reference protocols and Petrifilm™ plates. The results were compared using McNemar's test, linear regression and ANOVA (p < 0,05). The results demonstrated good significant between conventional methodologies and Petrifilm™ plates. Further, the Petrifim™ STX for counting S. aureus had higher recoverability of bacteria compared with the conventional methodology. Based on the results obtained and in view of the ease and rapidity procedures results, Petrifim ™ plates may be considered as alternatives for microbiological testing in sheep milk.
Resumo:
Abstract Biodegradable films blends made of safflower oil nutraceutical capsules waste corn starch (20:4, 30:4, 40:4 and 50:4) were prepared. The objective of this study was to evaluate the influence of addition of different concentrations of safflower oil nutraceutical capsule waste in the mechanical properties (tensile strength, elongation at break, Young’s modulus) and thickness of corn starch films. A decrease in tensile strength and Young’s modulus and an increase in elongation at break were observed with the increase in the content of the nutraceutical capsule waste. The results showed that the blends of safflower oil capsules waste-corn starch films demonstrated promising characteristics to form biodegradable films with different mechanical characteristics.
Resumo:
Uusia jäteveden puhdistusprosesseja kartoitetaan Suomessakin esimerkiksi kiristyvien päästömääräyksien vuoksi sekä parempia kustannus- ja energiatehokkuuksia tavoiteltaessa. Jätevesien puhdistus on Suomessa jo nykyään hyvällä tasolla, mutta muun muassa raskasmetallien, torjunta-aineiden, hormonien ja lääkeaineiden pitoisuuksien kasvut jätevesissä asettavat haasteita nykyisin käytössä oleville jäteveden puhdistusmenetelmille, sillä niitä ei ole suunniteltu näiden aineiden talteenottoon ja suurin osa aineista jää veteen. Lisäksi jätevedet halutaan nähdä enemmänkin resurssina kuin jätteenä, josta voidaan ottaa talteen hyödyllisiä komponentteja, kuten suoloja. Alueilla, joissa vuorokauden keskilämpötila pysyttelee edes osan vuodesta pakkasella, veden luonnollista jäätymisprosessia voidaan käyttää hyväksi jäteveden puhdistuksessa. Tässä työssä selvitettiin kiteytymisen teorian ja aikaisempien tutkimusten avulla, millaisten jätevesien puhdistukseen jäädytyskiteytys sopii sekä pohdittiin menetelmän potentiaalisia sovelluskohteita Suomessa. Jäädytyskiteytyksen todettiin olevan turvallinen ja energiatehokas ratkaisu monien koostumukseltaan erilaisien jätevesien puhdistukseen. Menetelmällä voitaneen puhdistaa öljyisiä, orgaanisia ja/tai epäorgaanisia epäpuhtauksia tai raskasmetalleja sisältäviä sekä myrkyllisiä jätevesiä. Olosuhteet prosessille ovat parhaat Pohjois-Suomessa, jossa vuorokauden keskilämpötila pysyttelee nollan alapuolella noin seitsemän kuukautta vuodesta. Etelä-Suomessa vastaava luku on kolme. Menetelmän potentiaalisia sovelluskohteita ovat esimerkiksi kaivosteollisuuden ja kaatopaikkojen jätevedet, joiden puhdistukseen jäädytyskiteytys saattaisi soveltua erinomaisesti. Jäädyttämällä voitaisiin myös puhdistaa tekstiili- ja nahkateollisuuden jätevesiä, sillä niiden sisältämien väriaineiden erottaminen vedestä on perinteisillä jäteveden puhdistusmenetelmillä usein vaikeaa tai jopa mahdotonta. Suolojen kiteyttämiseen vaadittavia korkeampia suolapitoisuuksia todettiin löytyvän lähinnä membraaniprosessien, kuten käänteisosmoosin, rejektivesistä. Sopivimmat eutektiset olosuhteet kiteyttämiseen ovat natriumsulfaatilla, kaliumsulfaatilla ja natriumkarbonaatilla. Veden luonnollisen jäätymisprosessin hyödyntäminen jätevedenpuhdistuksessa on huomionarvoinen idea. Prosessin käyttöönottoa haittaavat esimerkiksi korkeat investointikustannukset, mutta ne tulevat todennäköisesti ajan myötä teknologian kehittyessä laskemaan. Lisäksi monet prosessiin liittyvät käytännön asiat ovat vielä tutkimuksen alla. On myös huomattava, että Suomessakaan lämpötila ei pysyttele koko vuotta pakkasella, joten jäädytyksen rinnalla on oltava jokin toinen prosessi, jolla jätevedet puhdistetaan lämpötilan ollessa nollan yläpuolella.