624 resultados para flexion


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To analyze and compare the vertical component of ground reaction forces and isokinetic muscle parameters for plantar flexion and dorsiflexion of the ankle between long-distance runners, triathletes, and nonathletes. METHODS: Seventy-five males with a mean age of 30.26 (±6.5) years were divided into three groups: a triathlete group (n=26), a long-distance runner group (n = 23), and a non-athlete control group. The kinetic parameters were measured during running using a force platform, and the isokinetic parameters were measured using an isokinetic dynamometer. RESULTS: The non-athlete control group and the triathlete group exhibited smaller vertical forces, a greater ground contact time, and a greater application of force during maximum vertical acceleration than the long-distance runner group. The total work (180º/s) was greater in eccentric dorsiflexion and concentric plantar flexion for the non-athlete control group and the triathlete group than the long-distance runner group. The peak torque (60º/s) was greater in eccentric plantar flexion and concentric dorsiflexion for the control group than the athlete groups. CONCLUSIONS: The athlete groups exhibited less muscle strength and resistance than the control group, and the triathletes exhibited less impact and better endurance performance than the runners.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A quantidade de torque aplicado na articulação é uma medida de aptidão física importante para crianças com paralisia cerebral. O presente estudo analisou parâmetros cinéticos na articulação do cotovelo em crianças saudáveis e com paralisia cerebral. Participaram 10 crianças com paralisia cerebral e 10 crianças sem comprometimento neurológico. Avaliou-se a média do pico de torque, média do ângulo do pico de torque, coeficiente de variação do torque e aceleração angular do movimento de flexo-extensão do cotovelo nas velocidades com um dinamômetro isocinético. A média de pico de torque (extensão), aceleração (flexão) e coeficiente de variação (flexão e extensão) são diferentes entre grupos. Conclui-se que o torque e aceleração sofreram interferências no movimento de flexo-extensão; as principais diferenças encontradas foram entre os extremos das velocidades; não houve diferenças no ângulo do pico de torque. A espasticidade não interferiu na força dos músculos agonistas do movimento de flexão da articulação do cotovelo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Background: Coactivation may be both desirable (injury prevention) or undesirable (strength measurement). In this context, different styles of muscle strength stimulus have being investigated. In this study we evaluated the effects of verbal and visual stimulation on rectus femoris and biceps femoris muscles contraction during isometric and concentric. Methods: We investigated 13 men (age =23.1 ± 3.8 years old; body mass =75.6 ± 9.1 kg; height =1.8 ± 0.07 m). We used the isokinetic dynamometer BIODEX device and an electromyographic (EMG) system. We evaluated the maximum isometric and isokinetic knee extension and flexion at 60°/s. The following conditions were evaluated: without visual nor verbal command (control); verbal command; visual command and; verbal and visual command. In relation to the concentric contraction, the volunteers performed five reciprocal and continuous contractions at 60°/s. With respect to isometric contractions it was made three contractions of five seconds for flexion and extension in a period of one minute. Results: We found that the peak torque during isometric flexion was higher in the subjects in the VVC condition (p > 0.05). In relation to muscle coactivation, the subjects presented higher values at the control condition (p > 0.05). Conclusion We suggest that this type of stimulus is effective for the lower limbs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Running economy (RE), i.e. the oxygen consumption at a given submaximal speed, is an important determinant of endurance running performance. So far, investigators have widely attempted to individuate the factors affecting RE in competitive athletes, focusing mainly on the relationships between RE and running biomechanics. However, the current results are inconsistent and a clear mechanical profile of an economic runner has not been yet established. The present work aimed to better understand how the running technique influences RE in sub-elite middle-distance runners by investigating the biomechanical parameters acting on RE and the underlying mechanisms. Special emphasis was given to accounting for intra-individual variability in RE at different speeds and to assessing track running rather than treadmill running. In Study One, a factor analysis was used to reduce the 30 considered mechanical parameters to few global descriptors of the running mechanics. Then, a biomechanical comparison between economic and non economic runners and a multiple regression analysis (with RE as criterion variable and mechanical indices as independent variables) were performed. It was found that a better RE was associated to higher knee and ankle flexion in the support phase, and that the combination of seven individuated mechanical measures explains ∼72% of the variability in RE. In Study Two, a mathematical model predicting RE a priori from the rate of force production, originally developed and used in the field of comparative biology, was adapted and tested in competitive athletes. The model showed a very good fit (R2=0.86). In conclusion, the results of this dissertation suggest that the very complex interrelationships among the mechanical parameters affecting RE may be successfully dealt with through multivariate statistical analyses and the application of theoretical mathematical models. Thanks to these results, coaches are provided with useful tools to assess the biomechanical profile of their athletes. Thus, individual weaknesses in the running technique may be identified and removed, with the ultimate goal to improve RE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In case of severe osteoarthritis at the knee causing pain, deformity, and loss of stability and mobility, the clinicians consider that the substitution of these surfaces by means of joint prostheses. The objectives to be pursued by this surgery are: complete pain elimination, restoration of the normal physiological mobility and joint stability, correction of all deformities and, thus, of limping. The knee surgical navigation systems have bee developed in computer-aided surgery in order to improve the surgical final outcome in total knee arthroplasty. These systems provide the surgeon with quantitative and real-time information about each surgical action, like bone cut executions and prosthesis component alignment, by mean of tracking tools rigidly fixed onto the femur and the tibia. Nevertheless, there is still a margin of error due to the incorrect surgical procedures and to the still limited number of kinematic information provided by the current systems. Particularly, patello-femoral joint kinematics is not considered in knee surgical navigation. It is also unclear and, thus, a source of misunderstanding, what the most appropriate methodology is to study the patellar motion. In addition, also the knee ligamentous apparatus is superficially considered in navigated total knee arthroplasty, without taking into account how their physiological behavior is altered by this surgery. The aim of the present research work was to provide new functional and biomechanical assessments for the improvement of the surgical navigation systems for joint replacement in the human lower limb. This was mainly realized by means of the identification and development of new techniques that allow a thorough comprehension of the functioning of the knee joint, with particular attention to the patello-femoral joint and to the main knee soft tissues. A knee surgical navigation system with active markers was used in all research activities presented in this research work. Particularly, preliminary test were performed in order to assess the system accuracy and the robustness of a number of navigation procedures. Four studies were performed in-vivo on patients requiring total knee arthroplasty and randomly implanted by means of traditional and navigated procedures in order to check for the real efficacy of the latter with respect to the former. In order to cope with assessment of patello-femoral joint kinematics in the intact and replaced knees, twenty in-vitro tests were performed by using a prototypal tracking tool also for the patella. In addition to standard anatomical and articular recommendations, original proposals for defining the patellar anatomical-based reference frame and for studying the patello-femoral joint kinematics were reported and used in these tests. These definitions were applied to two further in-vitro tests in which, for the first time, also the implant of patellar component insert was fully navigated. In addition, an original technique to analyze the main knee soft tissues by means of anatomical-based fiber mappings was also reported and used in the same tests. The preliminary instrumental tests revealed a system accuracy within the millimeter and a good inter- and intra-observer repeatability in defining all anatomical reference frames. In in-vivo studies, the general alignments of femoral and tibial prosthesis components and of the lower limb mechanical axis, as measured on radiographs, was more satisfactory, i.e. within ±3°, in those patient in which total knee arthroplasty was performed by navigated procedures. As for in-vitro tests, consistent patello-femoral joint kinematic patterns were observed over specimens throughout the knee flexion arc. Generally, the physiological intact knee patellar motion was not restored after the implant. This restoration was successfully achieved in the two further tests where all component implants, included the patellar insert, were fully navigated, i.e. by means of intra-operative assessment of also patellar component positioning and general tibio-femoral and patello-femoral joint assessment. The tests for assessing the behavior of the main knee ligaments revealed the complexity of the latter and the different functional roles played by the several sub-bundles compounding each ligament. Also in this case, total knee arthroplasty altered the physiological behavior of these knee soft tissues. These results reveal in-vitro the relevance and the feasibility of the applications of new techniques for accurate knee soft tissues monitoring, patellar tracking assessment and navigated patellar resurfacing intra-operatively in the contest of the most modern operative techniques. This present research work gives a contribution to the much controversial knowledge on the normal and replaced of knee kinematics by testing the reported new methodologies. The consistence of these results provides fundamental information for the comprehension and improvements of knee orthopedic treatments. In the future, the reported new techniques can be safely applied in-vivo and also adopted in other joint replacements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L'attività di ricerca descritta in questa tesi fornisce linee guida per la progettazione di arti protesici inferiori, con particolare riferimento alla progettazione di protesi a basso costo. La necessità di efficienti protesi a basso costo risulta infatti sentita nei Paesi in via di sviluppo ma anche dalle fasce meno abbienti dei paesi occidentali. Al fine di comprendere le strategie adottate dall'apparato locomotorio per muoversi con le protesi sono analizzati il cammino fisiologico, le protesi presenti sul mercato ed infine le modalità con cui le loro prestazioni sono valutate. Con il presente lavoro, dopo aver osservato la presenza di una scarsa strutturazione della metodologia di progettazione che riguarda specialmente il settore del basso costo, si propone una metodologia il più possibile oggettiva e ripetibile tesa ad individuare quali sono gli aspetti essenziali di una protesi per garantire al paziente una buona qualità di vita. Solo questi aspetti dovranno essere selezionati al fine di ottenere la massima semplificazione della protesi e ridurre il più possibile i costi. Per la simulazione delle attività di locomozione, in particolare del cammino, è stato elaborato un apposito modello spaziale del cammino. Il modello proposto ha 7 membri rigidi (corrispondenti a piedi, tibie, femori e bacino) e 24 gradi di libertà. Le articolazioni e l'appoggio dei piedi al suolo sono modellati con giunti sferici. La pianta del piede consente tre possibili punti di appoggio. I criteri di realizzazione delle simulazioni possono comprendere aspetti energetici, cinematici e dinamici considerati come obiettivo dall'apparato locomotorio. In questa tesi vengono trattati in particolare gli aspetti cinematici ed è mostrata un'applicazione della procedura nella quale vengono dapprima identificati i riferimenti fisiologici del cammino e quindi simulato il cammino in presenza di una menomazione al ginocchio (eliminazione della flessione in fase di appoggio). Viene quindi lasciato a sviluppi futuri il completamento della procedura e la sua implementazione in un codice di calcolo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In martial arts there are several ways to perform the turning kick . Following the martial arts or different learning models many types of kicks take shape. Mawashi geri is the karate turning kick. At the moment there are two models of mawashi geri, one comes from the traditional karate (OLD), and the other newer (NEW), who agrees to the change of the rules of W.K.F. (World Karate Federation) happened in 2000 (Macan J. et all 2006) . In this study we are focus on the differences about two models the mawashi geri jodan of karate. The purpose of this study is to analyse cinematic and kinetic parameters of mawashi geri jodan. Timing of the striking and supporting leg actions were also evaluated A Vicon system 460 IR with 6 cameras at sample frequency of 200 Hz was used. 37 reflective markers have been set on the skin of the subjects following the “PlugInGait-total body model”. The participants performed five repetitions of mawashi geri jodan at maximum rapidity with their dominant leg against a ball suspended in front of them placed at ear height. Fourteen skilled subjects (mean level black belt 1,7 dan; age 20,9±4,8 yrs; height 171,4±7,3 cm; weight 60,9±10,2 Kg) practicing karate have been split in two group through the hierarchical cluster analysis following their technical characteristics. By means of the Mann Whitney-U test (Spss-package) the differences between the two groups were verified in preparatory and execution phase. Kicking knee at start, kicking hip and knee at take-off were different between the two groups (p < 0,05). Striking hip flexion during the spin of the supporting foot was different between the two groups (p < 0,05). Peak angular velocity of hip flexion were different between the two groups (p < 0,05). Groups showed differences also in timing of the supporting spin movement. While Old group spin the supporting foot at 30% of the trial, instead New start spinning at 44% of the trial. Old group showed a greater supporting foot spin than New (Old 110° Vs New 82°). Abduction values didn’t show any differences between the two groups. At the hit has been evaluated a 120° of double hips abduction, for the entire sample. Striking knee extension happened for everybody after the kicking hip flexion and confirm the proximal-distal action of the striking leg (Sorensen H. 1996). In contrast with Pearson J.N. 1997 and Landeo R 2007, peak velocity of the striking foot is not useful to describe kick performance because affected by the stature. Two groups are different either in preparatory phase or in execution phase. The body is set in difference manner already before the take-off of the kicking foot. The groups differ for the timing of the supporting foot action Trainer should pay attention to starting posture and on abduction capacities of the athletes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Total ankle arthroplasty (TAA) is still not as satisfactory as total hip and total knee arthroplasty. For the TAA to be considered a valuable alternative to ankle arthrodesis, an effective range of ankle mobility must be recovered. The disappointing clinical results of the current generation of TAA are mostly related to poor understanding of the structures guiding ankle joint mobility. A new design (BOX Ankle) has been developed, uniquely able to restore physiologic ankle mobility and a natural relationship between the implanted components and the retained ligaments. For the first time the shapes of the tibial and talar components in the sagittal plane were designed to be compatible with the demonstrated ligament isometric rotation. This resulted in an unique motion at the replaced ankle where natural sliding as well as rolling motion occurs while at the same time full conformity is maintained between the three components throughout the flexion arc. According to prior research, the design features a spherical convex tibial component, a talar component with radius of curvature in the sagittal plane longer than that of the natural talus, and a fully conforming meniscal component. After computer-based modelling and preliminary observations in several trial implantation in specimens, 126 patients were implanted in the period July 2003 – December 2008. 75 patients with at least 6 months follow-up are here reported. Mean age was 62,6 years (range 22 – 80), mean follow-up 20,2 months. The AOFAS clinical score systems were used to assess patient outcome. Radiographs at maximal dorsiflexion and maximal plantar flexion confirmed the meniscalbearing component moves anteriorly during dorsiflexion and posteriorly during plantarflexion. Frontal and lateral radiographs in the patients, show good alignment of the components, and no signs of radiolucency or loosening. The mean AOFAS score was observed to go from 41 pre-op to 74,6 at 6 month follow-up, with further improvement at the following follow-up. These early results reveal satisfactory clinical scores, with good recovery of range of motion and reduction of pain. Radiographic assessment reveals good osteointegration. All these preliminary results confirm biomechanical studies and the validity of this novel ligamentcompatible prosthesis design. Surely it will be important to re-evaluate these patients later.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sports biomechanics describes human movement from a performance enhancement and an injury reduction perspective. In this respect, the purpose of sports scientists is to support coaches and physicians with reliable information about athletes’ technique. The lack of methods allowing for in-field athlete evaluation as well as for accurate joint force estimates represents, to date, the main limitation to this purpose. The investigations illustrated in the present thesis aimed at providing a contribution towards the development of the above mentioned methods. Two complementary approaches were adopted: a Low Resolution Approach – related to performance assessment – where the use of wearable inertial measurement units is exploited during different phases of sprint running, and a High Resolution Approach – related to joint kinetics estimate for injury prevention – where subject-specific, non-rigid constraints for knee joint kinematic modelling used in multi-body optimization techniques are defined. Results obtained using the Low Resolution Approach indicated that, due to their portability and inexpensiveness, inertial measurement systems are a valid alternative to laboratory-based instrumentation for in-field performance evaluation of sprint running. Using acceleration and angular velocity data, the following quantities were estimated: trunk inclination and angular velocity, instantaneous horizontal velocity and displacement of a point approximating the centre of mass, and stride and support phase durations. As concerns the High Resolution Approach, results indicated that the length of the anterior cruciate and lateral collateral ligaments decreased, while that of the deep bundle of the medial collateral ligament increased significantly during flexion. Variations of the posterior cruciate and the superficial bundle of the medial collateral ligament lengths were concealed by the experimental indeterminacy. A mathematical model was provided that allowed the estimate of subject-specific ligament lengths as a function of knee flexion and that can be integrated in a multi-body optimization procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A main objective of the human movement analysis is the quantitative description of joint kinematics and kinetics. This information may have great possibility to address clinical problems both in orthopaedics and motor rehabilitation. Previous studies have shown that the assessment of kinematics and kinetics from stereophotogrammetric data necessitates a setup phase, special equipment and expertise to operate. Besides, this procedure may cause feeling of uneasiness on the subjects and may hinder with their walking. The general aim of this thesis is the implementation and evaluation of new 2D markerless techniques, in order to contribute to the development of an alternative technique to the traditional stereophotogrammetric techniques. At first, the focus of the study has been the estimation of the ankle-foot complex kinematics during stance phase of the gait. Two particular cases were considered: subjects barefoot and subjects wearing ankle socks. The use of socks was investigated in view of the development of the hybrid method proposed in this work. Different algorithms were analyzed, evaluated and implemented in order to have a 2D markerless solution to estimate the kinematics for both cases. The validation of the proposed technique was done with a traditional stereophotogrammetric system. The implementation of the technique leads towards an easy to configure (and more comfortable for the subject) alternative to the traditional stereophotogrammetric system. Then, the abovementioned technique has been improved so that the measurement of knee flexion/extension could be done with a 2D markerless technique. The main changes on the implementation were on occlusion handling and background segmentation. With the additional constraints, the proposed technique was applied to the estimation of knee flexion/extension and compared with a traditional stereophotogrammetric system. Results showed that the knee flexion/extension estimation from traditional stereophotogrammetric system and the proposed markerless system were highly comparable, making the latter a potential alternative for clinical use. A contribution has also been given in the estimation of lower limb kinematics of the children with cerebral palsy (CP). For this purpose, a hybrid technique, which uses high-cut underwear and ankle socks as “segmental markers” in combination with a markerless methodology, was proposed. The proposed hybrid technique is different than the abovementioned markerless technique in terms of the algorithm chosen. Results showed that the proposed hybrid technique can become a simple and low-cost alternative to the traditional stereophotogrammetric systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This text wants to explore the process of bone remodeling. The idea supported is that the signal, the cells acquire and which suggest them to change in their architectural conformation, is the potential difference on the free boundaries surfaces of collagen fibers. These ones represent the bone in the nanoscale. This work has as subject a multiscale model. Lots of studies have been made to try to discover the relationship between a macroscopic external bone load and the cellular scale. The tree first simulations have been a longitudinal, a flexion and a transversal compression force on a full longitudinal fiber 0-0 sample. The results showed first the great difference between a fully longitudinal stress and a flexion stress. Secondly a decrease in the potential difference has been observed in the transversal force configuration, suggesting that such a signal could be taken as the one, who leads the bone remodeling. To also exclude that the obtained results was not to attribute to a piezoelectric collagen effect and not to a mechanical load, different coupling analyses have been developed. Such analyses show this effect is really less important than the one the mechanical load is responsible of. At this point the work had to explore how bone remodeling could develop. The analyses involved different geometry and fibers percentage. Moreover at the beginning the model was to manually implement. The author, after an initial improvement of it, provided to implement a standalone version thanks to integration between Comsol Multiphysic, Matlab and Excel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This dissertation presents the synthesis of a hand exoskeleton (HE) for the rehabilitation of post-stroke patients. Through the analysis of state-of-the-art, a topological classification was proposed. Based on the proposed classification principles, the rehabilitation HEs were systematically analyzed and classified. This classification is helpful to both understand the reason of proposing certain solutions for specific applications and provide some useful guidelines for the design of a new HE, that was actually the primary motivation of this study. Further to this classification, a novel rehabilitation HE was designed to support patients in cylindrical shape grasping tasks with the aim of recovering the basic functions of manipulation. The proposed device comprises five planar mechanisms, one per finger, globally actuated by two electric motors. Indeed, the thumb flexion/extension movement is controlled by one actuator whereas a second actuator is devoted to the control of the flexion/extension of the other four fingers. By focusing on the single finger mechanism, intended as the basic model of the targeted HE, the feasibility study of three different 1 DOF mechanisms are analyzed: a 6-link mechanism, that is connected to the human finger only at its tip, an 8-link and a 12-link mechanisms where phalanges and articulations are part of the kinematic chain. The advantages and drawbacks of each mechanism are deeply analyzed with respect to targeted requirements: the 12-link mechanism was selected as the most suitable solution. The dimensional synthesis based on the Burmester theory as well as kinematic and static analyses were separately done for all fingers in order to satisfy the desired specifications. The HE was finally designed and a prototype was built. The experimental results of the first tests are promising and demonstrate the potential for clinical applications of the proposed device in robot-assisted training of the human hand for grasping functions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La rottura del Legamento Crociato Craniale (LCCr) rappresenta una delle patologie ortopediche di maggiore riscontro clinico nella specie canina. In seguito a rottura del LCCr si presenta un continuo slittamento craniale della tibia il quale esita in un processo osteoartrosico. La risoluzione chirurgica rappresenta la migliore soluzione terapeutica. Le tecniche chirurgiche extra-articolari con sfruttamento dei punti isometrici del ginocchio si presentano come delle procedure molto diffuse e utilizzate. Questa tesi propone di validare l’uso di un nuovo sistema di navigazione computerizzato-assistito per la valutazione cinematica durante la ricostruzione del LCCr nel cane, ma soprattutto di studiare e confrontare il comportamento e l’efficacia dopo ricostruzione TightRope (TR) in due diverse coppie di punti isometrici. Abbiamo effettuato due analisi in parallelo. La prima eseguendo interventi chirurgici con tecnica TR su 18 casi clinici e sfruttando il punto isometrico del femore (F2) e due diversi punti isometrici della tibia (T2 o T3). L’analisi prevedeva dei controlli postoperatori a 1, 3 e 6 mesi. Ad ogni controllo veniva effettuata una visita ortopedica, esami radiografici, un questionario di valutazione clinico e di soddisfazione del proprietario. Mentre nella ricerca Ex-Vivo abbiamo eseguito dei test su 14 preparati anatomici con l’utilizzo di un sistema di navigazione computerizzato per la rilevazione dei dati. L’analisi prevedeva la valutazione dell’articolazione in diversi stadi: LCCr intatto; LCCr rotto; dopo ricostruzione con TR in F2-T2 e tensionato a 22N, 44N e 99N; dopo ricostruzione con TR in F2-T3 e tensionato a 22N, 44N e 99N. Ad ogni stadio si eseguivano cinque test di valutazione, tra cui: Test del Cassetto, Test di compressione tibiale (TCT), Rotazione Interna/Esterna, Flesso/Estensione e Varo/Valgo. Lo scopo di tale studio è quello di confrontare tra loro i punti isometrici del ginocchio e di analizzare l’efficacia della tecnica TR nelle due differenti condizioni di isometria (F2-T2 e F2-T3).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wearable inertial and magnetic measurements units (IMMU) are an important tool for underwater motion analysis because they are swimmer-centric, they require only simple measurement set-up and they provide the performance results very quickly. In order to estimate 3D joint kinematics during motion, protocols were developed to transpose the IMMU orientation estimation to a biomechanical model. The aim of the thesis was to validate a protocol originally propositioned to estimate the joint angles of the upper limbs during one-degree-of-freedom movements in dry settings and herein modified to perform 3D kinematics analysis of shoulders, elbows and wrists during swimming. Eight high-level swimmers were assessed in the laboratory by means of an IMMU while simulating the front crawl and breaststroke movements. A stereo-photogrammetric system (SPS) was used as reference. The joint angles (in degrees) of the shoulders (flexion-extension, abduction-adduction and internal-external rotation), the elbows (flexion-extension and pronation-supination), and the wrists (flexion-extension and radial-ulnar deviation) were estimated with the two systems and compared by means of root mean square errors (RMSE), relative RMSE, Pearson’s product-moment coefficient correlation (R) and coefficient of multiple correlation (CMC). Subsequently, the athletes were assessed during pool swimming trials through the IMMU. Considering both swim styles and all joint degrees of freedom modeled, the comparison between the IMMU and the SPS showed median values of RMSE lower than 8°, representing 10% of overall joint range of motion, high median values of CMC (0.97) and R (0.96). These findings suggest that the protocol accurately estimated the 3D orientation of the shoulders, elbows and wrists joint during swimming with accuracy adequate for the purposes of research. In conclusion, the proposed method to evaluate the 3D joint kinematics through IMMU was revealed to be a useful tool for both sport and clinical contexts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The evaluation of the knee joint behavior is fundamental in many applications, such as joint modeling, prosthesis and orthosis design. In-vitro tests are important in order to analyse knee behavior when simulating various loading conditions and studying physiology of the joint. A new test rig for in-vitro evaluation of the knee joint behavior is presented in this paper. It represents the evolution of a previously proposed rig, designed to overcome its principal limitations and to improve its performances. The design procedure and the adopted solution in order to satisfy the specifications are presented here. Thanks to its 6-6 Gough-Stewart parallel manipulator loading system, the rig replicates general loading conditions, like daily actions or clinical tests, on the specimen in a wide range of flexion angles. The restraining actions of knee muscles can be simulated when active actions are simulated. The joint motion in response to the applied loads, guided by passive articular structures and muscles, is permitted by the characteristics of the loading system which is force controlled. The new test rig guarantees visibility so that motion can be measured by an optoelectronic system. Furthermore, the control system of the new test rig allows the estimation of the contribution of the principal leg muscles in guaranteeing the equilibrium of the joint by the system for muscle simulation. Accuracy in positioning is guaranteed by the designed tibia and femur fixation systems,which allow unmounting and remounting the specimen in the same pose. The test rig presented in this paper permits the analysis of the behavior of the knee joint and comparative analysis on the same specimen before and after surgery, in a way to assess the goodness of prostheses or surgical treatments.