942 resultados para Wall Thickness
Resumo:
The cell wall of Staphylococcus aureus is a highly complex network mainly composed of highly cross-linked peptidoglycan (PG) and teichoic acids (TAs), both important for the maintenance of the integrity and viability of bacteria. The penicillin binding proteins (PBPs), which catalyse the final stage of PG biosynthesis, are targets of β-lactam antibiotics and have been a key focus of antibacterial research. S. aureus has four native PBPs, PBP1-4 carried by both methicillin-sensitive (MSSA) and –resistant (MRSA) strains. PBP4 is required for the synthesis of the highly cross-linked PG and, as shown in recent studies, is essential for the expression of β-lactam resistance in community-acquired strains (CA-MRSA). This protein has a septal localization that seems to be spatially and temporally regulated by an unknown intermediate of the wall teichoic acids (WTA) biosynthesis pathway. Therefore, if WTA synthesis is compromised, PBP4 becomes dispersed throughout the entire cell membrane. The aim of this project was to identify the WTA precursor responsible for the septal recruitment of PBP4. In order to do so, inducible mutants of tarB and tarL genes in the background of NCTCPBP4-YFP were constructed allowing for the study of PBP4 localization in the presence and absence of these specific tar genes.With this work we were able to show that the absence of TarB or TarL leads to the delocalization of PBP4, indicating that TarL or a protein/WTA precursor whose localization/synthesis is dependent on TarL is responsible for the recruitment of PBP4.
Resumo:
Glazing is a technique used to retard fish deterioration during storage. This work focuses on the study of distinct variables (fish temperature, coating temperature, dipping time) that affect the thickness of edible coatings (water glazing and 1.5% chitosan) applied on frozen fish. Samples of frozen Atlantic salmon (Salmo salar) at -15, -20, and -25 °C were either glazed with water at 0.5, 1.5 or 2.5 °C or coated with 1.5% chitosan solution at 2.5, 5 or 8 °C, by dipping during 10 to 60 s. For both water and chitosan coatings, lowering the salmon and coating solution temperatures resulted in an increase of coating thickness. At the same conditions, higher thickness values were obtained when using chitosan (max. thickness of 1.41±0.05 mm) compared to water (max. thickness of 0.84±0.03 mm). Freezing temperature and crystallization heat were found to be lower for 1.5% chitosan solution than for water, thus favoring phase change. Salmon temperature profiles allowed determining, for different dipping conditions, whether the salmon temperature was within food safety standards to prevent the growth of pathogenic microorganisms. The concept of safe dipping time is proposed to define how long a frozen product can be dipped into a solution without the temperature raising to a point where it can constitute a hazard.
Resumo:
Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Engenharia Clínica)
Resumo:
PURPOSE: The aim of this work was to study the central and peripheral thickness of several contact lenses (CL) with different powers and analyze how thickness variation affects CL oxygen transmissibility. METHODS: Four daily disposable and five monthly or biweekly CL were studied. The powers of each CL were: the maximum negative power of each brand; -6.00 D; -3.00 D; zero power (-0.25 D or -0.50 D), +3.00 D and +6.00 D. Central and peripheral thicknesses were measured with an electronic thickness gauge. Each lens was measured five times (central and 3mm paracentral) and the mean value was considered. Using the values of oxygen permeability given by the manufacturers and the measured thicknesses, the variation of oxygen transmissibility with lens power was determined. RESULTS: For monthly or biweekly lenses, central thickness changed between 0.061 ± 0.002 mm and 0.243 ± 0.002 mm, and peripheral thickness varied between 0.084 ± 0.002 mm and 0.231 ± 0.015 mm. Daily disposable lenses showed central values ranging between 0.056 ± 0.0016 mm and 0.205 ± 0.002 mm and peripheral values between 0.108 ± 0.05 and 0.232 ± 0.011 mm. Oxygen transmissibility (in units) of monthly or biweekly CL ranged between 39.4 ± 0.3 and 246.0 ± 14.4 and for daily disposable lenses the values range between 9.5 ± 0.5 and 178.1 ± 5.1. CONCLUSIONS: The central and peripheral thicknesses change significantly when considering the CL power and this has a significant impact on the oxygen transmissibility. Eyecare practitioners must have this fact in account when high power plus or minus lenses are fitted or when continuous wear is considered.
Resumo:
Dissertação de mestrado integrado em Engenharia Mecânica
Resumo:
Projeto de investigação integrado de International Master in Sustainable Built Environment
Resumo:
OBJECTIVE: The intracellular Gram-negative bacterium Chlamydia pneumoniae has been associated with atherosclerosis. The presence of Chlamydia pneumoniae has been investigated in fragments of the arterial wall with a technique for DNA identification. METHODS: Arterial fragments obtained from vascular surgical procedures in 58 patients were analyzed. From these patients, 39 were males and the mean age was 65±6 years. The polymerase chain reaction was used to identify the bacterial DNA with a pair of primers that codify the major outer membrane protein (MOMP) of Chlamydia pneumoniae. The amplified product was visualized by electrophoresis in the 2% agarose gel stained with ethidium bromide, and it was considered positive when migrating in the band of molecular weight of the positive controls. RESULTS: Seven (12%) out of the 58 patients showed positive results for Chlamydia pneumoniae. CONCLUSION: DNA from Chlamydia pneumoniae was identified in the arterial wall of a substantial number of patients with atherosclerosis. This association, which has already been described in other countries, corroborates the evidence favoring a role played by Chlamydia pneumoniae in atherogenesis.
Resumo:
This paper reports on a new façade system that uses passive solutions in the search for energy efficiency. The differentials are the versatility and flexibility of the modules, which are important advantages of the system. The thermal performance of Trombe walls and glazings and the daylighting performance of glazing were the key aspects analyzed in the results. Computational simulations were accomplished for the thermal performance of different arrangements of the modules with DesignBuilder software. The glazing daylighting performance was studied by means of Ecotect and Desktop Radiance programs and compared with the transmittance curves of glazings. Occupancy profile and internal gains were fixed according to the Portuguese reality for both studies. The main characteristics considered in this research were the use of two double glazings, four different climates in Portugal and one and two Trombe walls in the façade. The results show an important reduction in the energy consumption with the use of Trombe walls and double self-cleaning glazing in the façade, which also presented better daylighting performance.
Resumo:
OBJECTIVE: To study the arrangement of the myocardial fiber bundles at the pulmonary venous left atrial junction in patients with pulmonary hypertension, and to discuss the pathophysiological importance of this element in the etiology of acute pulmonary edema. METHODS: We obtained 12 hearts and their pulmonary vein extremities from postmortem examinations of patients with the anatomicopathological diagnosis of acute pulmonary edema. The specimens, which had no grossly visible morphological cardiac alterations, were fixed in 10% formalin, and the muscular arrangement of the pulmonary venous left atrial junctions was analyzed. This material was then isolated, embedded in paraffin, underwent serial cutting (50 µm of thickness), and was stained with Azam's trichrome. RESULTS: We observed in our specimens that: a) the myocardial fiber bundles that originate in the atrial wall and involve the openings of the pulmonary veins were fewer than those observed in healthy material; b) the myocardial fiber bundles that extend into the pulmonary veins were shorter than those found in material originating from individuals with no pulmonary hypertension. CONCLUSION: Anatomical changes that result in a reduction in the amount of myocardial fiber bundles in the pulmonary venous left atrial junction, isolated or associated with other factors, may be the cause of disorders in pulmonary circulation, leading to an increase in pulmonary venous pressure, and, consequently, to acute pulmonary edema.
Resumo:
OBJECTIVE: To assess the prevalence of white-coat normortension, white-coat hypertension, and white-coat effect. METHODS: We assessed 670 medical records of patients from the League of Hypertension of the Hospital das Clínicas of the Medical School of the University of São Paulo. White-coat hypertension (blood pressure at the medical office: mean of 3 measurements with the oscillometric device ³140 or ³90 mmHg, or both, and ambulatory blood pressure monitoring mean during wakefulness < 135/85) and white-coat normotension (office blood pressure < 140/90 and blood pressure during wakefulness on ambulatory blood pressure monitoring ³ 135/85) were analyzed in 183 patients taking no medication. The white-coat effect (difference between office and ambulatory blood pressure > 20 mmHg for systolic and 10 mmHg for diastolic) was analyzed in 487 patients on treatment, 374 of whom underwent multivariate analysis to identify the variables that better explain the white-coat effect. RESULTS: Prevalence of white-coat normotension was 12%, prevalence of white-coat hypertension was 20%, and prevalence of the white-coat effect was 27%. A significant correlation (p<0.05) was observed between white-coat hypertension and familial history of hypertension, and between the white-coat effect and sex, severity of the office diastolic blood pressure, and thickness of left ventricular posterior wall. CONCLUSION: White-coat hypertension, white-coat normotension, and white-coat effect should be considered in the diagnosis of hypertension.
Resumo:
OBJECTIVE: To assess whether the intima-media thickness of the common carotid artery of patients with coronary artery disease is greater than that of individuals without that disease. METHODS: Case-control prospective study of prevalence assessing the thickness of the intima and media layers of 29 patients with coronary artery disease and 29 individuals without that disease by using ultrasonography of the carotid arteries. Diabetic patients and those with peripheral artery and cerebral vasculopathies were excluded from the study. RESULTS: The mean age was 51±7.5 years. Fifty-five per cent of the patients were males. Acute myocardial infarction was present in 62%; cardiac catheterization in 72%; saphenous bypass in 5%; and coronary angioplasty in 24%. The intima-media thickness of the common carotid artery in case patients and in control patients was, respectively, 0.81±0.25 mm and 0.62±0.18 mm (P=0.001). CONCLUSION: Intima-media thickness of the common carotid artery was significantly greater in patients with coronary artery disease.
Resumo:
Somatic post-surgical pain is invalidating and distressing to patients and carries the risk of important complications. The anterior abdominal wall is involved in most surgical procedures in general, gynecologic, obstetric, urological, vascular and pediatric surgery. Combined multimodal strategies involving nerve blocks, opiates, and non-steroidal anti-inflammatory drugs for systemic analgesia are necessary for optimal pain modulation. Anterior abdominal wall blocks, transverse abdominal plexus block, iliohypogastric and ilioinguinal nerveblock, genitofemoral nerve block and rectus sheath block have an important role as components of multimodal analgesia for somatic intraoperative and postoperative pain control. Ultrasound visualization has improved the efficacy and safety of abdominal blocks and implemented the application in the clinical setting. For this reason, they are a very important tool for all anesthesiologists who aim to treat effectively patients’ pain. This guide provides an evidence based comprehensive and necessary overview of anatomical, anesthesiological and technical information needed to safely perform these blocks.
Regenerative action of the wall on the heat transfer for directly and indirectly heated rotary kilns
Resumo:
Rotary kilns, Regenerative wall, heat transfer, directly fired, indirectly fired
Resumo:
In heart failure syndrome, myocardial dysfunction causes an increase in neurohormonal activity, which is an adaptive and compensatory mechanism in response to the reduction in cardiac output. Neurohormonal activity is initially stimulated in an attempt to maintain compensation; however, when it remains increased, it contributes to the intensification of clinical manifestations and myocardial damage. Cardiac remodeling comprises changes in ventricular volume as well as the thickness and shape of the myocardial wall. With optimized treatment, such remodeling can be reversed, causing gradual improvement in cardiac function and consequently improved prognosis.
Resumo:
Abstract Background: The association between periatrial adiposity and atrial arrhythmias has been shown in previous studies. However, there are not enough available data on the association between epicardial fat tissue (EFT) thickness and parameters of ventricular repolarization. Thus, we aimed to evaluate the association of EFT thickness with indices of ventricular repolarization by using T-peak to T-end (Tp-e) interval and Tp-e/QT ratio. Methods: The present study included 50 patients whose EFT thickness ≥ 9 mm (group 1) and 40 control subjects with EFT thickness < 9 mm (group 2). Transthoracic echocardiographic examination was performed in all participants. QT parameters, Tp-e intervals and Tp-e/QT ratio were measured from the 12-lead electrocardiogram. Results: QTd (41.1 ± 2.5 vs 38.6 ± 3.2, p < 0.001) and corrected QTd (46.7 ± 4.7 vs 43.7 ± 4, p = 0.002) were significantly higher in group 1 when compared to group 2. The Tp-e interval (76.5 ± 6.3, 70.3 ± 6.8, p < 0.001), cTp-e interval (83.1 ± 4.3 vs. 76±4.9, p < 0.001), Tp-e/QT (0.20 ± 0.02 vs. 0.2 ± 0.02, p < 0.001) and Tp-e/QTc ratios (0.2 ± 0.01 vs. 0.18 ± 0.01, p < 0.001) were increased in group 1 in comparison to group 2. Significant positive correlations were found between EFT thickness and Tp-e interval (r = 0.548, p < 0.001), cTp-e interval (r = 0.259, p = 0.01), and Tp-e/QT (r = 0.662, p < 0.001) and Tp-e/QTc ratios (r = 0.560, p < 0.001). Conclusion: The present study shows that Tp-e and cTp-e interval, Tp-e/QT and Tp-e/QTc ratios were increased in subjects with increased EFT, which may suggest an increased risk of ventricular arrhythmia.