920 resultados para Successive Overrelaxation method with 1 parameter


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The role of the therapeutic drug monitoring laboratory in support of immunosuppressant drug therapy is well established, and the introduction of sirolimus (SRL) is a new direction in this field. The lack of an immunoassay for several years has restricted the availability of SRL assay services. The recent availability of a CEDIA (R) SRL assay has the potential to improve this situation. The present communication has compared the CEDIA (R) SRL method with 2 established chromatographic methods, HPLC-UV and HPLC-MS/MS. The CEDIA (R) method, run on a Hitachi 917 analyzer, showed acceptable validation criteria with within-assay precision of 9.1% and 3.3%, and bias of 17.1% and 5.8%, at SRL concentrations of 5.0 mu g/L and 20 mu g/L, respectively. The corresponding between-run precision values were 11.5% and 3.3% and bias of 7.1% and 2.9% at 5.0 mu g/L and 20 mu g/L, respectively, The lower limit of quantification was found to be 3.0 mu g/L. A series of 96 EDTA whole-blood samples predominantly from renal transplant recipients were assayed by the 3 methods for comparison. It was found that the CEDIA (R) method showed a Deming regression line of CEDIA = 1.20 X HPLC-MS/MS - 0.07 (r = 0.934, SEE = 1.47), with a mean bias of 20.4%. Serial blood samples from 8 patients included in this evaluation showed that the CEDIA (R) method reflected the clinical fluctuations in the chromatographic methods, albeit with the variable bias noted. The CEDIA (R) method on the H917 analyzer is therefore a useful adjunct to SRL dosage individualization in renal transplant recipients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Adsorption of supercritical fluids is increasingly carried out to determine the micropore size distribution. This is largely motivated by the advances in the use of supercritical adsorption in high energy applications, such as hydrogen and methane storage in porous media. Experimental data are reported as mass excess versus pressure, and when these data are matched against the theoretical mass excess, significant errors could occur if the void volume used in the calculation of the experimental mass excess is incorrectly determined [Malbrunot, P.; Vidal, D.; Vermesse, J.; Chahine, R.; Bose, T. K. Langmuir 1997, 13, 539]. 1 The incorrect value for the void volume leads to a wrong description of the maximum in the plot of mass excess versus pressure as well as the part of the isotherm over the pressure region where the isotherm is decreasing. Because of this uncertainty in the maximum and the decreasing part of the isotherm, we propose a new method in which the problems associated with this are completely avoided. Our method involves only the relationship between the amount that is introduced into the adsorption cell and the equilibrium pressure. This information of direct experimental data has two distinct advantages. The first is that the data is the raw data without any manipulation (i.e., involving further calculations), and the second one is that this relationship always monotonically increases with pressure. We will illustrate this new method with the adsorption data of methane in a commercial sample of activated carbon.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: In 1992, Frisch et al (Psychol Assess. 1992;4:92- 10 1) developed the Quality of Life Inventory (QOLI) to measure the concept of quality of life (QOL) because it has long been thought to be related to both physical and emotional well-being. However, the psychometric properties of the QOLI in clinical populations are still in debate. The present study examined the factor structure of QOLI and reported its validity and reliability in a clinical sample. Method: Two hundred seventeen patients with anxiety and depressive disorders completed the QOLI and additional questionnaires measuring symptoms (Zung Self-rating Depression Scale, Beck Anxiety Inventory, Fear Questionnaire, Depression Anxiety Stress Scale-Stress) and subjective well-being (Satisfaction With Life Scale) were also used. Results: Exploratory factor analysis via the principal components method, with oblique rotation, revealed a 2-factor structure that accounted for 42.73% of the total variance, and a subsequent confirmatory factor analysis suggested a moderate fit of the data to this model. The 2 factors appeared to describe self-oriented QOL and externally oriented QOL. The Cronbach alpha coefficients were 0.85 for the overall QOLI score, 0.81 for the first factor, and 0.75 for the second factor. Conclusion: Consistent evidence was also found to support the concurrent, discriminant, predictive, and criterion-related validity of the QOLI. (c) 2006 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Therapeutic monitoring with dosage individualization of sirolimus drug therapy is standard clinical practice for organ transplant recipients. For several years sirolimus monitoring has been restricted as a result of lack of an immunoassay. The recent reintroduction of the microparticle enzyme immunoassay (MEIA (R)) for sirolimus on the IMx (R) analyser has the potential to address this situation. This Study, using patient samples, has compared the MEIA (R) sirolimus method with an established HPLC-tandem mass spectrometry method (HPLC-MS/MS). An established HPLC-UV assay was used for independent cross-validation. For quality control materials (5, 11, 22 mu g/L), the MEIA (R) showed acceptable validation criteria based on intra-and inter-run precision (CV) and accuracy (bias) of < 8% and < 13%, respectively. The lower limit of quantitation was found to be approximately 3 mu g/L. The performance of the immunoassay was compared with HPLC-MS/MS using EDTA whole-blood samples obtained from various types of organ transplant recipients (n = 116). The resultant Deming regression line was: MEIA = 1.3 x HPLC-MS/MS+ 1.3 (r = 0.967, s(y/x) = 1) with a mean bias of 49.2% +/- 23.1 % (range, -2.4% to 128%; P < 0.001). The reason for the large and variable bias was not explored in this study, but the sirolimus-metabolite cross-reactivity with the MEIA (R) antibody could be a substantive contributing factor. Whereas the MEIA (R) sirolimus method may be an adjunct to sirolimus dosage individualization in transplant recipients, users must consider the implications of the substantial and variable bias when interpreting results. In selected patients where difficult clinical issues arise, reference to a specific chromatographic method may be required.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports preliminary progress on a principled approach to modelling nonstationary phenomena using neural networks. We are concerned with both parameter and model order complexity estimation. The basic methodology assumes a Bayesian foundation. However to allow the construction of pragmatic models, successive approximations have to be made to permit computational tractibility. The lowest order corresponds to the (Extended) Kalman filter approach to parameter estimation which has already been applied to neural networks. We illustrate some of the deficiencies of the existing approaches and discuss our preliminary generalisations, by considering the application to nonstationary time series.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Synthetic hydrogel polymers were prepared by free radical photopolymerization in aqueous solution of the sodium salt of 2-acrylamido-2-methylpropane sulfonic acid (Na-AMPS). Poly(ethylene glycol) diacrylate (PEGDA) and 4,4'-azo-bis(4-cyanopentanoic acid) were used as the crosslinker and UV-photoinitiator, respectively. The effects of varying the Na-AMPS monomer concentration within the range of 30-50% w/v and the crosslinker concentration within the range of 0.1-1.0% mol (relative to monomer) were studied in terms of their influence on water absorption properties. The hydrogel sheets exhibited extremely high swelling capacities in aqueous media which were dependent on monomer concentration, crosslink density, and the ionic strength and composition of the immersion medium. The effects of varying the number-average molecular weight of the PEGDA crosslinker from = 250 to 700 were also investigated. Interestingly, it was found that increasing the molecular weight and therefore the crosslink length at constant crosslink density decreased both the rate of water absorption and the equilibrium water content. Cytotoxicity testing by the direct contact method with mouse fibroblast L929 cells indicated that the synthesized hydrogels were nontoxic. On the basis of these results, it is considered that photopolymerized Na-AMPS hydrogels crosslinked with PEGDA show considerable potential for biomedical use as dressings for partial thickness burns. This paper describes some structural effects which are relevant to their design as biomaterials for this particular application. © 2013 Copyright Taylor and Francis Group, LLC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

MSC 2010: 34A08 (main), 34G20, 80A25

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diabetes patients might suffer from an unhealthy life, long-term treatment and chronic complicated diseases. The decreasing hospitalization rate is a crucial problem for health care centers. This study combines the bagging method with base classifier decision tree and costs-sensitive analysis for diabetes patients' classification purpose. Real patients' data collected from a regional hospital in Thailand were analyzed. The relevance factors were selected and used to construct base classifier decision tree models to classify diabetes and non-diabetes patients. The bagging method was then applied to improve accuracy. Finally, asymmetric classification cost matrices were used to give more alternative models for diabetes data analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Drillhole-determined sea-ice thickness was compared with values derived remotely using a portable small-offset loop-loop steady state electromagnetic (EM) induction device during expeditions to Fram Strait and the Siberian Arctic, under typical winter and summer conditions. Simple empirical transformation equations are derived to convert measured apparent conductivity into ice thickness. Despite the extreme seasonal differences in sea-ice properties as revealed by ice core analysis, the transformation equations vary little for winter and summer. Thus, the EM induction technique operated on the ice surface in the horizontal dipole mode yields accurate results within 5 to 10% of the drillhole determined thickness over level ice in both seasons. The robustness of the induction method with respect to seasonal extremes is attributed to the low salinity of brine or meltwater filling the extensive pore space in summer. Thus, the average bulk ice conductivity for summer multiyear sea ice derived according to Archie's law amounts to 23 mS/m compared to 3 mS/m for winter conditions. These mean conductivities cause only minor differences in the EM response, as is shown by means of 1-D modeling. However, under summer conditions the range of ice conductivities is wider. Along with the widespread occurrence of surface melt ponds and freshwater lenses underneath the ice, this causes greater scatter in the apparent conductivity/ice thickness relation. This can result in higher deviations between EM-derived and drillhole determined thicknesses in summer than in winter.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ESR-spectra of foraminifera in arctic sediment cores display the [CO2]- -signal (g=2.0006). Research on the thermal behaviour of the [CO2]- -signal shows that both natural and artificial irradiation generates a precursor and a thermal unstable component of the [CO2]- -signal. The precursor can be transfered to the stable radical, and unstable radicals can be removed by heating. The signal-change by heating depends on the irradiation dose. Because of the varying response on thermal treatment, the dose-response curves show systematic differences depending on the applied procedure (single- or multi-aliquot method with or without heating). A model for the description of the [CO2]- -signal-change is presented. The combination of two exponential saturation functions seems to be an adequate analytical description of the dose-response curve of the [CO2]- -signal in foraminifera. Due to the limited thermal stability this signal can be used for dating foraminifera with ages up to about 190 ka.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this article we consider the development of discontinuous Galerkin finite element methods for the numerical approximation of the compressible Navier-Stokes equations. For the discretization of the leading order terms, we propose employing the generalization of the symmetric version of the interior penalty method, originally developed for the numerical approximation of linear self-adjoint second-order elliptic partial differential equations. In order to solve the resulting system of nonlinear equations, we exploit a (damped) Newton-GMRES algorithm. Numerical experiments demonstrating the practical performance of the proposed discontinuous Galerkin method with higher-order polynomials are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Reduced-representation sequencing technology iswidely used in genotyping for its economical and efficient features. A popular way to construct the reduced-representation sequencing libraries is to digest the genomic DNA with restriction enzymes. A key factor of this method is to determine the restriction enzyme(s). But there are few computer programs which can evaluate the usability of restriction enzymes in reduced-representation sequencing. SimRAD is an R package which can simulate the digestion of DNA sequence by restriction enzymes and return enzyme loci number as well as fragment number. But for linkage mapping analysis, enzyme loci distribution is also an important factor to evaluate the enzyme. For phylogenetic studies, comparison of the enzyme performance across multiple genomes is important. It is strongly needed to develop a simulation tool to implement these functions. Results: Here, we introduce a Perl module named RestrictionDigest with more functions and improved performance. It can analyze multiple genomes at one run and generate concise comparison of enzyme performance across the genomes. It can simulate single-enzyme digestion, double-enzyme digestion and size selection process and generate comprehensive information of the simulation including enzyme loci number, fragment number, sequences of the fragments, positions of restriction sites on the genome, the coverage of digested fragments on different genome regions and detailed fragment length distribution. Conclusions: RestrictionDigest is an easy-to-use Perl module with flexible parameter settings.With the help of the information produced by the module, researchers can easily determine the most appropriate enzymes to construct the reduced-representation libraries to meet their experimental requirements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2015.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de Mestrado apresentada ao Instituto Superior de Psicologia Aplicada para obtenção de grau de Mestre na especialidade de Psicologia Clínica.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les stérosomes, des vésicules artificielles composées d’amphiphiles monoalkylés et d’un grand pourcentage de stérols, sont prometteurs dans plusieurs domaines comme les industries pharmaceutiques et alimentaires. Il existe des stérosomes chargés négativement, positivement et neutres. Dans ce mémoire, nous avons approfondi nos connaissances sur les propriétés physico-chimiques des stérosomes chargés : acide palmitique (PA)/stérol et stéarylamine (SA)/cholestérol (Chol). Premièrement, afin de mesurer la diffusion latérale de PA dans les membranes PA/stérol (30/70 mol/mol) par RMN à gradients pulsés, nous avons tenté de former des bicouches liquide-ordonnées (lo) orientées magnétiquement avec ce mélange. En s'inspirant de l’idée que l’ajout de 1,2-dihexanoyl-sn-glycéro-3-phosphocholine (DHPC), un lipide à courtes chaînes, dans le système 1,2-dimyristoyl-sn-glycéro-3-phosphocholine (DMPC) mène à la formation de bicouches orientées, nous avons étudié la formulation PA perdeutéré/acide hexanoïque (HA)/Chol avec une proportion molaire de 25/18/57 à plusieurs températures; aucune formation de bicouches orientées n’a été observée. Ce résultat pourrait être expliqué par la solubilisation partielle de HA en milieu aqueux. Alors, une quantité insuffisante serait insérée dans la bicouche pour induire son orientation. La formulation PA perdeutéré/DHPC/Chol n’a pas conduit, elle non plus, à des bicouches orientées magnétiquement à des températures et concentrations lipidiques variées. En étudiant le mélange DMPC/DHPC/Chol (67/17/14), nous avons remarqué que la présence de Chol inhibait l'orientation magnétique des bicouches. Tandis que le mélange DMPC/DHPC/stigmastérol (SS) avec les proportions molaires 67/19/14 et 72/21/7 conduisait à des bicouches orientées avec leur normale (n) perpendiculaire au champ magnétique à 40 °C et 50 °C. Ces résultats suggèrent que le mélange PA/SS avec une proportion de lipide à courtes chaînes, HA et DHPC, pourrait mener à des bicouches orientées magnétiquement. Le mélange PA/Chol avec un lipide à courtes chaînes pourrait aussi être étudié en présence des lanthanides. Deuxièmement, nous avons examiné la possibilité de moduler la libération de matériel encapsulé dans des liposomes essentiellement composés de PA et d’un stérol. Il est connu que le mélange PA/Chol (30/70) à pH ≥ 7,5 forme des liposomes très peu perméables. Il est avantageux de pouvoir moduler la perméabilité pour avoir un contrôle sur le temps de libération de leur contenu, qui est un paramètre de grande importance pour les formulations liposomales de médicaments. D’abord, il a été montré que l’acide oléique (OA)/Chol (30/70) est capable de former des vésicules, ce qui n’avait jamais été prouvé auparavant. Par contre, les bicouches OA/Chol (30/70) ne sont pas plus perméables que les bicouches PA/Chol (30/70). L’ajout de 1-palmitoyl-2-oléoyl-sn-glycéro-3-phosphatidylcholine (POPC) dans le mélange PA/Chol n’augmente pas plus la perméabilité. En effet, les cinétiques de relargage de calcéine des vésicules PA/POPC/Chol (15/27.5/57.5), POPC/Chol (40/60) et POPC étaient très semblables à celle de PA/Chol (30/70). Il a été remarqué que les études littéraires se contredisent à propos de la perméabilité à la calcéine des bicouches de phosphatidylcholine (PC). L’explication de ces divergences est inconnue pour le moment. En remplaçant la moitié de la proportion molaire de Chol par le cholate de sodium (SC) dans le mélange PA/Chol (30/70), la membrane n’était pas plus apte à libérer son contenu. Il se pourrait que le SC se retrouvant dans la bicouche n’induit pas une diminution d’empilement. Il est aussi possible que le SC ne s'insère pas dans la membrane à cause de son hydrophilie considérable et il pourrait alors former seul des micelles. En remplaçant complètement le Chol par le sulfate de cholestérol (SChol), un stérol chargé négativement, et en préparant les vésicules à un bas pH, la formulation PA/SChol (30/70) mène à une très grande perméabilité à pH 7.5; le relargage est provoqué par un saut de pH. Nos travaux suggèrent qu'il serait possible de moduler la perméabilité des liposomes en les préparant avec le mélange PA/SChol/Chol en variant les proportions entre 30/63/7 à 30/70/0. Le diagramme pH-composition du mélange PA/SChol/Chol indique que ces proportions conduisent, à pH 7.4, à la coexistence de phases solide et lo en différentes proportions, ce qui pourrait moduler la perméabilité membranaire. Troisièmement, les résultats de perméabilité obtenus avec la calcéine et les difficultés survenues lors de l’extrusion des vésicules encapsulant cette sonde nous ont amené à nous demander si la calcéine interagit avec les bicouches chargées. L’impact de certains anions, dont la calcéine, a été examiné sur les bicouches chargées positivement SA/Chol (50/50). La calorimétrie différentielle à balayage (DSC, de l’anglais differential scanning calorimetry), indique qu’il n’y a aucune transition entre 25 et 90 °C pour les liposomes SA/Chol (50/50) à pH = 7.4. L’ajout de chlorure de sodim (375 mM) n’a pas mené à la formation d’agrégats et aucune transition n’a été observée sur le thermogramme. La formation d’agrégats macroscopiques instantanément après l’ajout d’hydrogénophosphate de sodium (125 mM), de sulfate de sodium (125 mM) et de calcéine (3 mM) a été observée. Une transition a été observée sur les thermogrammes en présence de ces sels. Les agrégats observés pourraient être associés à la transition de phase. L’effet des anions sur la température et l’enthalpie de transition suivent le même ordre que la série d’Hofmeister : sulfate > hydrogénophosphate > chlorure (pas de pic). La calcéine avait l’impact le plus prononcé sur l’agrégation; ceci illustre que la calcéine n’est pas une sonde fluorescente inerte avec le mélange SA/Chol. Elle pourrait être un chaotrope volumineux. De plus, les interactions SA-calcéine plus fortes, menant à l’agrégation des vésicules, que les interactions PC-calcéine pourraient s’expliquer par le fait que la SA est chargée positivement.