923 resultados para Side pixel registration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new domain-specific reconfigurable sub-pixel interpolation architecture for multi-standard video Motion Estimation (ME) is presented. The mixed use of parallel and serial-input FIR filters achieves high throughput rate and efficient silicon utilisation. Flexibility has been achieved by using a multiplexed reconfigurable data-path controlled by a selection signal. Silicon design studies show that this can be implemented using 34.8K gates with area and performance that compares very favourably with existing fixed solutions based solely on the H.264 standard. ©2008 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The experience of border crossing for refugees and irregular migrants challenges global border and migration controls in multiple contexts. Using qualitative field research in Tanzania, Spain, Morocco and Australia, Heather Johnson asks how a global regime of migration management and control can be perceived through the dynamics of particular border spaces: refugee camps, border zones and detention centres. She explores how irregular migrants are impacted by the increasingly security-oriented practices of border control, and how they confront these practices. Johnson rejects the characterization of border spaces as exceptional, abject and exclusionary, arguing instead for an understanding of politics as everyday contestation that reveals a radical political agency, re-imagining the global non-citizen as a transgressive and powerful figure. Building on recent scholarship that rethinks irregularity and non-citizenship, her conclusions have broad implications for how we understand irregular migration from a position of dialogue and solidarity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Haematological malignancies (HM) represent over 6% of the total cancer incidence in Europe and affect all ages, ranging between 45% of all cancers in children and 7% in the elderly. Thirty per cent of childhood cancer deaths are due to HM, 8% in the elderly. Their registration presents specific challenges, mainly because HM may transform or progress in the course of the disease into other types of HM. In the context of cancer registration decisions have to be made about classifying subsequent notifications on the same patient as the same tumour (progression), a transformation or a new tumour registration. Allocation of incidence date and method of diagnosis must also be standardised. We developed European Network of Cancer Registries (ENCR) recommendations providing specific advice for cancer registries to use haematology and molecular laboratories as data sources, conserve the original date of incidence in case of change of diagnosis, make provision for recording both the original as well as transformed tumour and to apply precise rules for recording and counting multiple diagnoses. A reference table advising on codes which reflect a potential transformation or a new tumour is included. This work will help to improve comparability of data produced by population-based cancer registries, which are indispensable for aetiological research, health care planning and clinical research, an increasing important area with the application of targeted therapies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Aquivion short-side-chain (SSC) perfluorosulfonic acid (PFSA) ionomer was adopted in catalyst layers (CL) of polymer electrolyte membrane water electrolysers (PEMWE) instead of long-side-chain (LSC) Nafion ionomer. The effects of SSC ionomer content in CL for oxygen evolution reaction were studied in half cell with cyclic voltammetry and steady state linear sweep. In a single cell test the MEA with SSC-PFSA Aquivion ionomer exhibited better thermal stability than the one with LSC-PFSA Nafion ionomer at 90 °C. The cell voltage at a current density of 1 A cm was 1.63 V at 90 °C using the SSC-PFSA Aquivion ionomer binder, Nafion 117 membrane, and without back pressurizing. In a continuous operation the cell voltage degradation rate of the MEA using Aquivion ionomer binder was only about 0.82 mV h.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An unusual application of hydrological understanding to a police search is described. The lacustrine search for a missing person provided reports of bottom-water currents in the lake and contradictory indications from cadaver dogs. A hydrological model of the area was developed using pre-existing information from side scan sonar, a desktop hydrogeological study and deployment of water penetrating radar (WPR). These provided a hydrological theory for the initial search involving subaqueous groundwater flow, focused on an area of bedrock surrounded by sediment, on the lake floor. The work shows the value a hydrological explanation has to a police search operation (equally to search and rescue). With hindsight, the desktop study should have preceded the search, allowing better understanding of water conditions. The ultimate reason for lacustrine flow in this location is still not proven, but the hydrological model explained the problems encountered in the initial search.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the intermittent nature of renewable generation it is desirable to consider the potential of controlling the demand-side load to smooth overall system demand. The architecture and control methodologies of such a system on a large scale would require careful consideration. Some of these considerations are discussed in this paper; such as communications infrastructure, systems architecture, control methodologies and security. A domestic fridge is used in this paper as an example of a controllable appliance. A layered approach to smart-grid is introduced and it can be observed how each smart-grid component from physical cables, to the end-devices (or smart-applications) can be mapped to these set layers. It is clear how security plays an integral part in each component of the smart-grid so this is also an integral part of each layer. The controllable fridge is described in detail and as one potential smart-grid application which maps to the layered approach. A demonstration system is presented which involves a Raspberry Pi (a low-power, low-cost device representing the appliance controller).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Significant recent progress has shown ear recognition to be a viable biometric. Good recognition rates have been demonstrated under controlled conditions, using manual registration or with specialised equipment. This paper describes a new technique which improves the robustness of ear registration and recognition, addressing issues of pose variation, background clutter and occlusion. By treating the ear as a planar surface and creating a homography transform using SIFT feature matches, ears can be registered accurately. The feature matches reduce the gallery size and enable a precise ranking using a simple 2D distance algorithm. When applied to the XM2VTS database it gives results comparable to PCA with manual registration. Further analysis on more challenging datasets demonstrates the technique to be robust to background clutter, viewing angles up to +/- 13 degrees and with over 20% occlusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new method for online determination of the Thèvenin equivalent parameters of a power system at a given node using the local PMU measurements at that node. The method takes into account the measurement errors and the changes in the system side. An analysis of the effects of changes in system side is carried out on a simple two-bus system to gain an insight of the effect of system side changes on the estimated Thévenin equivalent parameters. The proposed method uses voltage and current magnitudes as well as active and reactive powers; thus avoiding the effect of phase angle drift of the PMU and the need to synchronize measurements at different instances to the same reference. Applying the method to the IEEE 30-bus test system has shown its ability to correctly determine the Thévenin equivalent even in the presence of measurement errors and/or system side changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context Medical students can have difficulty in distinguishing left from right. Many infamous medical errors have occurred when a procedure has been performed on the wrong side, such as in the removal of the wrong kidney. Clinicians encounter many distractions during their work. There is limited information on how these affect performance. 
Objectives Using a neuropsychological paradigm, we aim to elucidate the impacts of different types of distraction on left–right (LR) discrimination ability. 
Methods Medical students were recruited to a study with four arms: (i) control arm (no distraction); (ii) auditory distraction arm (continuous ambient ward noise); (iii) cognitive distraction arm (interruptions with clinical cognitive tasks), and (iv) auditory and cognitive distraction arm. Participants’ LR discrimination ability was measured using the validated Bergen Left–Right Discrimination Test (BLRDT). Multivariate analysis of variance was used to analyse the impacts of the different forms of distraction on participants’ performance on the BLRDT. Additional analyses looked at effects of demographics on performance and correlated participants’ self-perceived LR discrimination ability and their actual performance. 
Results A total of 234 students were recruited. Cognitive distraction had a greater negative impact on BLRDT performance than auditory distraction. Combined auditory and cognitive distraction had a negative impact on performance, but only in the most difficult LR task was this negative impact found to be significantly greater than that of cognitive distraction alone. There was a significant medium-sized correlation between perceived LR discrimination ability and actual overall BLRDT performance. 
Conclusions
Distraction has a significant impact on performance and multifaceted approaches are required to reduce LR errors. Educationally, greater emphasis on the linking of theory and clinical application is required to support patient safety and human factor training in medical school curricula. Distraction has the potential to impair an individual's ability to make accurate LR decisions and students should be trained from undergraduate level to be mindful of this.