801 resultados para Minimal Deformation Template


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with a system that describes an electrical circuitcomposed by a linear system coupled to a nonlinear one involving a tunneldiode in a flush-and-fill circuit. One of the most comprehensive models for thiskind of circuits was introduced by R. Fitzhugh in 1961, when taking on carebiological tasks. The equation has in its phase plane only two periodic solutions,namely, the unstable singular point S0 and the stable cycle Γ. If the system isat rest on S0, the natural flow of orbits seeks to switch-on the process by going- as time goes by - toward its steady-state, Γ. By using suitable controls it ispossible to reverse such natural tendency going in a minimal time from Γ toS0, switching-off in this way the system. To achieve this goal it is mandatorya minimal enough strength on controls. These facts will be shown by means ofconsiderations on the null control sets in the process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the deformation suffered by cantilevered implant-supported fixed prostheses frameworks cast in silver-palladium alloy and coated with two occlusal veneering materials: acrylic resin or porcelain. Material and Methods: Two strain gauges were bonded to the inferior surface of the silver-palladium framework and two other were bonded to the occlusal surface of the prosthesis framework covered with ceramic and acrylic resin on each of its two halves. The framework was fixed to a metallic master model and a 35.2 N compression force was applied to the cantilever at 10, 15 and 20 mm from the most distal implant. The measurements of deformation by compression and tension were obtained. The statistical 2-way ANOVA test was used for individual analysis of the experiment variables and the Tukey test was used for the interrelation between all the variables (material and distance of force application). Results: The results showed that both variables had influence on the studied factors (deformation by compression and tension). Conclusion: The ceramic coating provided greater rigidity to the assembly and therefore less distortion compared with the uncoated framework and with the resin-coated framework. The cantilever arm length also influenced the prosthesis rigidity, causing higher deformation the farther the load was applied from the last implant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Morphology and deformation mechanisms and tensile properties of tetrafunctional multigraft (MG) polystrene-g-polyisoprene (PS-g-PI) copolymers were investigated dependent on PS volume fraction and number of branch points. The combination of various methods such as TEM, real time synchrotron SAXS, rheo-optical FTIR, and tensile tests provides comprehensive information at different dimension levels.TEMand SAXS studies revealed that the number of branch points has no obvious influence on the microphase-separated morphology of tetrafunction MG copolymers with 16 wt % PS. But for tetrafunctional MG copolymers with 25 wt % PS, the size and integrity of PS microdomains decrease with increasing number of branch point. The deformation mechanisms ofMGcopolymers are highly related to the morphology. Dependent on the microphase-separated morphology and integrity of the PS phase, the strain-induced orientation of the PS phase is at different size scales. Polarized FT-IR spectra analysis reveals that, for all investigated MG copolymers, the PI phase shows strain-induced orientation along SD at molecular scale. The proportion of the PI block effectively bridging PS domains controls the tensile properties of the MGcopolymers at high strain, while the stress-strain behavior in the low-mediate strain region is controlled by the continuity of PS microdomains. The special molecular architecture, which leads to the higher effective functionality of PS domains and the higher possibility for an individual PI backbone being tethered with a large number of PS domains, is proposed to be the origin of the superelasticity for MG copolymers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Masticatory muscle contraction causes both jaw movement and tissue deformation during function. Natural chewing data from 25 adult miniature pigs were studied by means of time series analysis. The data set included simultaneous recordings of electromyography (EMG) from bilateral masseter (MA), zygomaticomandibularis (ZM) and lateral pterygoid muscles, bone surface strains from the left squamosal bone (SQ), condylar neck (CD) and mandibular corpus (MD), and linear deformation of the capsule of the jaw joint measured bilaterally using differential variable reluctance transducers. Pairwise comparisons were examined by calculating the cross-correlation functions. Jaw-adductor muscle activity of MA and ZM was found to be highly cross-correlated with CD and SQ strains and weakly with MD strain. No muscle’s activity was strongly linked to capsular deformation of the jaw joint, nor were bone strains and capsular deformation tightly linked. Homologous muscle pairs showed the greatest synchronization of signals, but the signals themselves were not significantly more correlated than those of non-homologous muscle pairs. These results suggested that bone strains and capsular deformation are driven by different mechanical regimes. Muscle contraction and ensuing reaction forces are probably responsible for bone strains, whereas capsular deformation is more likely a product of movement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This document style is intended for reading onscreen. It creates a two-page spread that fits on a single screen (of 1024 x 768 pixels), with type that remains readable at 75% magnification. It includes design and typographic settings to accommodate common text elements: headings, subtitles, extracts, etc. The font is Lucida Sans Unicode, set single-spaced. It is a sans serif font, which allows for greater readability at smaller sizes and onscreen. The basic text size is 11 point. The font is engi¬neered with a tall line-height, so that even set “solid” (i.e., single-spaced) there is ample “leading” between the lines for clear reading. The overall design is “left aligned”—that is all titles, subtitles, headings, etc. are lined up on the left margin. Paragraphs are justified, for easier reading; titles, headings, references, captions, and endnotes are not justified. The two files attached to this documents are: Screen SansSerif file.doc = a blank MS Word file with these page and type specifications already loaded. Enter (or paste) your text into this file and Save under a new name. Screen SansSerif template.dot = an MS Word template; use this to create a new blank document. Templates are generally stored in a folder in Program Files > Microsoft Office > Templates The main document contains sample pages and specifications for the type, margins, settings, etc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This study sought to outline the clinical and laboratory characteristics of minimal change disease in adolescents and adults and establish the clinical and laboratory characteristics of relapsing and non-relapsing patients. METHODS: We retrospectively evaluated patients with confirmed diagnoses of minimal change disease by renal biopsy from 1979 to 2009; the patients were aged >13 years and had minimum 1-year follow-ups. RESULTS: Sixty-three patients with a median age (at diagnosis) of 34 (23-49) years were studied, including 23 males and 40 females. At diagnosis, eight (12.7%) patients presented with microscopic hematuria, 17 (27%) with hypertension and 17 (27%) with acute kidney injury. After the initial treatment, 55 (87.3%) patients showed complete remission, six (9.5%) showed partial remission and two (3.1%) were nonresponders. Disease relapse was observed in 34 (54%) patients who were initial responders (n = 61). In a comparison between the relapsing patients (n = 34) and the non-relapsing patients (n = 27), only proteinuria at diagnosis showed any significant difference (8.8 (7.1-12.0) vs. 6.0 (3.6-7.3) g/day, respectively, p = 0.001). Proteinuria greater than 7 g/day at the initial screening was associated with relapsing disease. CONCLUSIONS: In conclusion, minimal change disease in adults may sometimes present concurrently with hematuria, hypertension, and acute kidney injury. The relapsing pattern in our patients was associated with basal proteinuria over 7 g/day.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyzed cerebrospinal fluid (CSF) samples from 65 consecutive children with acute lymphoblastic leukemia (ALL) treated according to two different treatment protocols (GBTLI-ALL-93 and -99) with no puncture accident for minimal residual disease (MRD) in the central nervous system (CNS). Minimal residual disease was detected by polymerase chain reaction (PCR) with homo/heteroduplex analysis using consensus primers to IgH and TCR genes. MRD in the CSF at diagnosis was detected by PCR in 46.8% of children with no puncture accident or morphological involvement. In patients treated with GBTLI-ALL-93 a significantly lower 5-year event-free survival (EFS) was demonstrated for those with CSF involvement, in univariate (p = 0.01) and multivariate (p = 0.04) analysis. This observation was not true for patients treated with the more intensive protocol GBTLI-ALL-99 (p = 0.81). These findings suggest that MRD detection in the CSF is a common event in children with ALL. Treatment intensification provided by the GBTLI-ALL-99 apparently overcomes the detrimental effect of CNS minimal residual disease at diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The jucara's palm (Euterpe edulis), native to the Atlantic Forest is one of the palms most exploited for the removal of heart palm and the tree was removed in large areas. The aim of this study was to examine the feasibility of the methodology of "minimally processed" in jucara's palm. The raw material was obtained by COOPERAGUA, Sete Barras (SP) through a Sustainable Management Plan culminating in a permit issued by IBAMA, Forestry Foundation and DPRN. The process began with the withdrawal of external sheaths and cut, with subsequent immersion in a solution of sodium metabisulphite (Na2S2O5 - 200 ppm), sanitize with a chlorine solution and soak in brine acidified to wait until the filling. The cuttings were placed in polyethylene bags containing acidified solution at concentrations A 0.225%, B 0.375%, C 0.6%, D 0.825% determined by titration curve. The staining became clearer in treatments C and D, due to more acidity, resulting in higher inactivation of enzymes. Even with these positive results, were concluded that minimal processing of jucara is not effective due to the blackout, preventing its commercialization. To stop it requires the bleaching step, which does not characterize it as minimally processed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When a cylinder is connected to an abutment it is expected that abutment and cylinder will be subjected to compression forces throughout their periphery because of the clamping force exerted by the screw. The deformation resultant of this compression should be measurable and uniform along the periphery of the abutment. Considering that multiple retainers connected to each other can affect the fit of a framework, as well as the use of different alloys, it is expected that the abutments will present different levels of deformation as a result of framework connection. The aim of this study was to evaluate the deformation of implant abutments after frameworks, cast either in cobalt-chromium (CoCr) or silver-palladium (AgPd) alloys, were connected. Samples (n = 5) simulating a typical mandibular cantilevered implant-supported prosthesis framework were fabricated in cobalt-chromium and silver-palladium alloys and screwed onto standard abutments positioned on a master-cast containing 5 implant replicas. Two linear strain gauges were fixed on the mesial and distal aspects of each abutment to capture deformation as the retention screws were tightened. A combination of compressive and tensile forces was observed on the abutments for both CoCr and AgPd frameworks. There was no evidence of significant differences in median abutment deformation levels for 9 of the 10 abutment aspects. Visually well-fit frameworks do not necessarily transmit load uniformly to abutments. The use of CoCr alloy for implant-supported prostheses frameworks may be as clinically acceptable as AgPd alloy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 19-year-old female with type 1 diabetes for four years, and a 73-year-old female with type 2 diabetes for twenty years developed sudden-onset nephrotic syndrome. Examination by light microscopy, immunofluorescence, and electron microscopy (in one case) identified minimal change disease (MCD) in both cases. There was a potential causative drug (meloxicam) for the 73-year-old patient. Both patients were treated with prednisone and responded with complete remission. The patient with type 1 diabetes showed complete remission without relapse, and the patient with type 2 diabetes had two relapses; complete remission was sustained after associated treatment with cyclophosphamide and prednisone. Both patients had two years of follow-up evaluation after remission. We discuss the outcomes of both patients and emphasize the role of kidney biopsy in diabetic patients with an atypical proteinuric clinical course, because patients with MCD clearly respond to corticotherapy alone or in conjunction with other immunosuppressive agents. Arq Bras Endocrinol Metab. 2012;56(5):331-5

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Women with a family history of breast cancer who develop this disease are confronted with important situations regarding the increased risk for development of a second cancer in the contralateral breast. Prophylactic contralateral mastectomy (PCM) reduces by approximately 95% the risk for contralateral breast cancer. In spite of an increase in indications for PCM, the technical difficulties are many regarding the accomplishment of these procedures. The aim of this study is to describe the technique of mastectomy with preservation of the nipple-areola complex and a small incision, reducing surgical difficulties and complications attributed to this technique, thus allowing better aesthetic results in breast reconstruction. Methods: Forty-six patients with indications for PCM (28 bilateral) were submitted to minimally invasive mastectomy from March 2005 to November 2007. A small incision in the superior pole of the areola, sufficient to pass a liposuction 4 mm cannula is made. With the help of this cannula, detachment of the skin from the gland tissue is performed. Then a 3.5 to 4.5-cm long incision in the inframammary fold is made. Glandular detachment is completed using cautery in the sub,glandular portion and scissors in the upper breast portion cutting the restraints left by the cannula. The mammary gland tissue is removed through this incision. Results: Seventy-four breasts were operated on. The resected breast mass ranged from 285 g to 475 g. All 43 patients were reconstructed with prostheses. There was no necrosis of the nipple-areola complex or of the skin. Conclusions: This technique is an option for cases of patients with indications for PCM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We construct harmonic functions on random graphs given by Delaunay triangulations of ergodic point processes as the limit of the zero-temperature harness process. (C) 2012 Elsevier B.V All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interpretation of the effect of plastic deformation on the calculated excess loss component (anomalous-loss) supports the concept of loss separation. Magnetic losses and Barkhausen noise of nonoriented electrical steel sheets were measured on Epstein strips taken from a single coil of 0.8% Si nonoriented electrical steel. Sheets were extracted in the annealed condition, without any skin pass and with a grain size of 18 mu m. This material was cold rolled in order to obtain sets of samples with true strain from 2% up to 29%. X-ray diffraction was used to estimate the dislocation density. The analysis of magnetic properties was performed by Barkhausen noise measurements and also by analyzing the hysteresis loops obtained from Epstein frame measurements for different inductions and different frequencies (including the quasi-static regime for hysteresis loss measurements). These data allowed us to observe that most of the well known total loss increase with plastic deformation is due to an increase in the hysteresis loss component, while excess loss decreases to become negligible. This behavior can be explained if it is assumed that the plastic deformation lead to an increase in the number of domain walls per unit volume, thereby decreasing the excess loss. Barkhausen peak area increases with plastic deformation, reproducing results taken from samples of different silicon content.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyse several examples of separable Banach spaces, some of them new, and relate them to several dichotomies obtained in [11], by classifying them according to which side of the dichotomies they fall.