990 resultados para Illinois Industrial Pollution Control Financing Authority
Resumo:
The use of Natural Gas Vehicle has had a fast increase lately. However, in order to have a continuous success this Program needs to develop converting devices of Otto-cycle engines, gasoline or alcohol, to the use of NGV (Natural Gas Vehicle) that presents low cost, maintaining the same original development of the vehicle and low level of emissions, considering the PROCONVE rules. Due to the need to diversify the matrix in order to avoid energetic dependence and due to strict pollution control, it has increased in the Brazilian market the number of vehicles converted to the use of NGV. The recent regulation of the PROCONVE, determining that the converted engines with kits should be submitted to emission testing, comes to reinforce the necessity of the proposed development. Therefore, if we can obtain kits with the characteristics already described, we can reach a major trust in the market and obtain an increase acceptance of the vehicle conversion for NGV. The use of natural gas as vehicle fuel presents several advantages in relation to liquid fuels. It is a vehicle fuel with fewer indexes of emissions when compared to diesel; their combustion gases are less harmful, with a major level of safety than liquid fuels and the market price is quite competitive. The preoccupation that emerges, and the motivation of this project, is to know which are the main justifications for such technology, well accepted in other countries, with a low index or emission, with a high level of safety, where its maintenance becomes low, reminding that for this it is necessary that this technology has to be used properly, and once available in the market will not motivate interest in the urban transportation companies in Brazil, in research centers in general. Therefore this project exists to show the society in a general way the current vision of the main governmental factors, of the national research centers and of the private companies concerning the use of natural gas vehicles in urban transport vehicles, in order to give a major reliability to the population as well as to motivate national market competitiveness with a low cost and reliable product and to enrich the national technology
Resumo:
This paper describes the design, implementation and enforcement of a system for industrial process control based on fuzzy logic and developed using Java, with support for industrial communication protocol through the OPC (Ole for Process Control). Besides the java framework, the software is completely independent from other platforms. It provides friendly and functional tools for modeling, construction and editing of complex fuzzy inference systems, and uses these logical systems in control of a wide variety of industrial processes. The main requirements of the developed system should be flexibility, robustness, reliability and ease of expansion
Resumo:
According to the Forest Code of 1965, it is mandatory that every rural property destine part of its land to the establishment of Legal Reserves. When a diagnosis is made over all Brazil, the reality is quite different from what is demanded by law. Therefore, this work, as a general objective, proposes ways of establishing Legal Reserves based on the analysis of the environmental deterioration in a river basin. For this purpose, the environmental deterioration was detected based on three diagnoses: physical-conservational, socioeconomical, and environmental quality. In this way, from a quantitative and qualitative diagnosis, it was possible to identify the main aggressive factors in the studied river basin and to indicate the main vulnerabilities that the area is subjected. According to such diagnosis, some proposals for the establishment of Legal Reserves are discussed here based on scientific arguments aimed at the conservation of water resources, soil and biodiversity. It is hoped, that from this study, the environment receives a new tool for diagnosis, pollution control, recovery and conservation of natural resources.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
O profissional de saúde é um ponto-chave para a implementação do Sistema Único de Saúde (SUS). À medida que exerce sua função, o sistema passa do aspecto teórico-conceitual para a prática da atenção. Objetivou-se neste estudo verificar o nível de conhecimento sobre o Sistema Único de Saúde (SUS) dos coordenadores de saúde bucal e cirurgiões-dentistas do serviço público dos 40 municípios da região noroeste do Estado de São Paulo. Utilizou-se um questionário estruturado, autoaplicável, composto de questões referentes aos princípios doutrinários e organizativos do SUS, controle social, financiamento, formação de recursos humanos, atenção e assistência em saúde. Dos entrevistados, 77 (89,5%) não sabiam quem era o responsável pelo planejamento e execução da assistência, 53 (61,6%) não tinham conhecimento de equidade, 46 (53,5%) de fundo de saúde e 45 (52,3%) de controle social. Conclui-se que existe deficiência no conhecimento de determinados assuntos, havendo necessidade de promoção de cursos a respeito da filosofia do SUS.
Resumo:
We compared the fish assemblage structure from streams with different intensities of physical habitat degradation and chemical water pollution by domestic sewage in southeastern Brazil. Eight streams (R1-R8) showing less disturbed or more disturbed conditions of chemical water quality and of physical habitat quality were selected. Cumulative abundance and biomass, combined in ABC plots, revealed (i) biomass curves above the abundance curves, represented by the streams R1-R2 (water and habitat less disturbed) and R5-R6 (water more disturbed and habitat less disturbed), and (ii) biomass curves below the abundance curves, represented by the streams R3-R4 (water less disturbed and habitat more disturbed) and R7-R8 (water and habitat more disturbed). The quantitative structure of the ichthyofauna showed significant correspondence with physical habitat condition but not with chemical water quality. The most significant species to cause the dissimilarity between less disturbed and more disturbed physical habitats was the exotic Poecilia reticulata. Such results indicate that in the focused region-with little influence of industrial pollution, noncritical domestic sewage discharge, and soil predominantly used for pasture-streams with high physical habitat integrity possess a differently structured ichthyofauna than streams with relatively low physical habitat integrity, reinforcing the importance of the physical habitat quality and riparian conservation along these water courses, warranting the conservation of these systems. Indeed, our results also reinforce the importance of including biotic descriptors, particularly of the ichthyo-fauna, in water-monitoring programs designed to reveal signs of human interference.
Resumo:
This investigation was carried out within the Parana sedimentary basin, Brazil, involved the sampling of effluents and groundwater from monitoring stations situated at different sites at São Paulo State, and was realized with the purpose of evaluating the presence of fats, oil and grease (FOG) in different matrices. Several tests were realized with very distinct materials (cooking oil, butter, margarine, pig fat, vacuum pump oil) in order to properly calibrate the spectrophotometric system. Each matrix was dissolved with 1,1,1-trichloroethane and from the stock solutions it was prepared working standards from different dilutions. The data obtained were plotted on absorbance vs. concentration graph that yielded a successful calibration curve when a mineral oil for vacuum pump was utilized in the experiments at a wavelength corresponding to 410 mn. The results obtained for the analyzed samples were compared with the limiting value established by the São Paulo State legislation on the prevention and pollution control of the environment that was established in 8(th) September 1976 by Rule No. 8468.
Resumo:
This paper describes an analytical reflectometric method that has an objective not only the industrial quality control but also to detect possible falsifications and/or adulterations of propranolol in pharmaceutical formulations. The method is based on the diffuse reflectance measurements of the colored product (III) of the spot test reaction between propranolol hydrochloride (I) and 2,6-dichloroquinone-4-chloroimide (II) using filter paper as solid support. Spot test conditions have been investigated using experimental design in order to identify and optimize the critical factors. The factors evaluated were DCQ concentration, propranolol solvent and DCQ solvent. The best reaction conditions were achieved with the addition of 30 mu L, of propranolol solution in ethanol 35% (v/v) and 30 mu L of DCQ solution at 70 mg mL(-1) in acetone, in this order. All reflectance measurements were carried out at 500 nm and the linear range was from 8.45 x 10(-4) to 8.45 x 10(-2) mol L-1 (r= 0.998). The limit of detection was 1.01 x 10(-4) mol L-1. No interference was observed from the assessed excipients and drugs. The method was applied to determine propranolol in commercial brands of pharmaceuticals. The results obtained by the proposed method were favorably compared with those given by the British Pharmacopoeia procedure. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
The first studies with constructed wetlands undertaken in Brazil were the result of observations made from the Amazon flood plains. The first attempt to use this capacity to change the quality of the water, in the sense of purification performed in Brazil using constructed wetland systems, was made by Salati et al. After that, new technologies were developed in a focused attempt to increase the efficiency of the system and reduce investments. Over these 18 years, persuading the Brazilian scientific community as well as the environmental control agencies to give due attention to this kind of research has required endless efforts. Only in recent years have major institutions responsible for sewage treatment and potable water supply been concerned with this type of technology for solving real problems. These institutions are as follows: SABESP (Basic Sanitation Company of Sao Paulo State), SANEPAR (Sanitation Company of Parana State) and CESP (Electric Company of Sao Paulo State). One of the private institutions that has systematically worked in the design and projects of constructed wetlands is the Institute of Applied Ecology. This institution has enhanced and developed a water depuration system based on the purifying capacity of the soil. The wetlands with filtering soils are systems formed by overlapping layers of crushed stone, gravel and soil planted with rice. This technology has been used in sewage treatment and also in water supply systems.
Resumo:
The São Paulo State has 36 million people, 25 million living in three metropolitan areas. Only the São Paulo Metropolitan Region (SPMR) includes the state capital (São Paulo City) plus 38 cities, where ≈ 18 million people live, affected by frequent episodes of ozone, NOx, and fine particulate matter. In 2003, it was estimated that 15.1% of the SPMR vehicles used ethanol and 70.2% used the local gasoline. Natural gas vehicles have witnessed a booming participation in the last years, mainly through conversion of gasoline cars, and the present fleet is almost one million vehicles. To face the problems generated by light vehicles emissions the Federal Government set a program called PROCONVE - Program of Air Pollution Control from Vehicles - in 1986 and since then until now a significant reduction was reached, but the growth of the fleet hides most of the emission cuts. A discussion covers the evolution of the air pollution management in São Paulo; and innovative tools for air pollution management - both for mobile and stationary sources. This is an abstract of a paper presented at the 98th AWMA Annual Conference and Exhibition (Minneapolis, MN 6/21-24/2005).
Resumo:
Study of consumption rate and gaseous pollutant emission from engine tests simulating real work conditions, using spark point manually controlled and exhaust gas recirculation (EGR) in diverse proportion levels. The objective of this work is to re-examine the potential of the EGR conception, a well-known method of combustion control, employed together electronic fuel injection and three-way catalytic converter closed-loop control at a spark ignition engine, verifying the performance characteristics and technical availability of this conception to improve pollution control, fuel economy at low torque drive condition and to improve the engine exhaust components useful life. The pollutant emissions and consumption levels under operational conditions simulations were analysed and compared with the expected by concerning theory and real tests performed by EGR equipped engines by factory. Copyright © 2006 Society of Automotive Engineers, Inc.
Resumo:
This paper describes a simple, environmentally friendly and rapid quantitative spot test procedure for the determination of captopril (CPT) in bulk drug and in pharmaceutical formulations by using diffuse reflectance spectroscopy. The proposed method is based on the reflectance measurements of the orange compound (λ max 490 nm) produced by the spot test reaction between CPT and p-chloranil (CL). Under optimal conditions, calibration curves were obtained for CPT by plotting the optical density of the reflectance signal (A R) vs. the log of the mol L -1 concentration, from 6.91×10 -3 to 1.17×10 -1, with a good coefficient of determination (R 2 = 0.9992). The common excipients used as additives in pharmaceuticals do not interfere in the proposed method. The method was applied to determine CPT in commercial pharmaceutical formulations. The results obtained by the proposed method are compared favorably with those obtained by an official procedure at 95% confidence level. The method validation results showed that the sensitivity and selectivity of the methods were adequated for drug monitoring in industrial quality control laboratories. © 2011 Moment Publication.
Resumo:
This paper proposes a straightforward compromising method to determine the output power of all committed units during the scheduling time horizon. Unlike the conventional methods that work based on a constant pollution control cost (CPCC), this method works based on the system topology such as demand, minimum cost and minimum output emission of the system. In order to have a meaningful compromise between costs and emission in economic and emission dispatch (EED) problem, a flexible pollution control cost (FPCC) is proposed. Also a dynamic economic emission dispatch (DEED) approach is considered where the ramping constraints couple the scheduling hours; the inclusion of valve-point effect makes the DEED modeling more practical. The validity and effectiveness of the unproblematic FPCC approach is verified through an IEEE 30-bus test system with 6 unit for the 6-hour scheduling horizon. © 2013 IEEE.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em História - FCHS