947 resultados para Error de medida


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the hypothesis that changes in nutritional status could be partly responsible for observed increases in myopia prevalence among Chinese children. DESIGN: Cross-sectional cohort study. METHODS: Rural Chinese secondary school children participating in a study of interventions to promote spectacle use were randomly sampled (20% of children with uncorrected vision >6/12 bilaterally, and 100% of remaining children) and underwent cycloplegic refraction with subjective refinement and measurement of height and weight. Stunting was defined according to the World Health Organization standard population. RESULTS: Among 3226 children in the sample, 2905 (90.0%) took part. Among 1477 children undergoing refraction, 1371 (92.8%) had height and weight measurements. These children had a mean age of 14.5 +/- 1.4 years, 59.8% were girls, and mean spherical equivalent refraction was -1.93 +/- 1.82 diopters. Stunting was present in 87 children (6.4%). While height was inversely associated with refractive error (RE) (taller children were more myopic) among boys (r = -0.147, P = .001), this disappeared when adjusting for age, and no such association was observed among girls. Neither girls nor boys with stunting differed significantly in refraction from children without stunting, and neither stunting nor height was associated with RE when adjusting for age, height, and parental education. The power of this study to have detected a 0.75 diopters difference in RE between children with and without stunting was 0.96. CONCLUSION: Results from this cross-sectional study are not consistent with the hypothesis that nutritional status is a determinant of RE in this setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: China is urbanizing rapidly, and the prevalence of myopia is high. This study was conducted to identify the reasons for observed differences in the prevalence of myopia among urban versus rural Chinese children. METHODS: All children with uncorrected acuity of 6/12 or worse and a 50% random sample of children with vision better than 6/12 at all secondary schools in mixed rural-urban Liangying Township, Guangdong, underwent cycloplegic refraction, and provided data on age, gender, parental education, weekly near work and time outdoors, and urban development level of respondents' neighborhoods (12-item questionnaire). Population density of 32 villages and urban zones in Liangying was calculated from census figures (mean population density, 217 persons/km(2); range, 94-957; mean for Guangdong, 486). RESULTS: Among 5844 eligible children, 4612 (78.9%) had parental consent and completed examinations; 2957 were refracted per protocol, and 2480 (83.9%) of these had questionnaire data. Those with completed examinations were more likely to be girls (P < 0.001), and questionnaire respondents were more myopic (P = 0.02), but otherwise did not differ significantly from nonrespondents. In multivariate models, older age (P < 0.001), more near work (P = 0.02), and higher population density (P = 0.003), but not development index, parental education, or time outdoors were significantly associated with more myopic refractive error. CONCLUSIONS: Higher population density appears to be associated with myopia risk, independent of academic activity, time spent outdoors, familial educational level, or economic development, factors that have been thought to explain higher myopia prevalence among urban children. Mechanisms for this apparent association should be sought.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Low corneal hysteresis is associated with longer axial length in Chinese secondary school children. The authors sought to explore this association in primary school children. METHODS: LogMAR presenting visual acuity, cycloplegic refractive error, ocular biometry, central corneal thickness (CCT), and corneal hysteresis (CH) was assessed for children in grades 1 to 3 at an academically competitive urban school in Shantou, China. RESULTS: Among 872 eligible children (mean age, 8.6 ± 2.1 years), 651 (74.7%) completed the examination. Among 1299 examined eyes, 111 (8.5%) had uncorrected vision ≤6/12. Mean spherical equivalent refractive error for all eyes was +0.26 ± 1.41 D, and axial length (AL) was 22.7 ± 0.90 mm. CH for the lowest (mean AL, 21.7 ± 0.39 mm), two middle (mean AL, 22.4 ± 0.15 and 22.9 ± 0.15 mm), and highest quartiles (mean AL, 23.7 ± 0.74 mm) of AL were 10.6 ± 2.1 mm Hg, 10.4 ± 2.1 mm Hg, 10.3 ± 2.3 mm Hg, and 10.2 ± 2.3 mm Hg respectively (age- and gender-adjusted Pearson's correlation coefficient r = -0.052; P = 0.001). In generalized estimating equation models adjusting for age, gender, and CCT, lower CH was significantly associated with longer AL (P < 0.001) and more myopic refractive error (P = 0.001). CONCLUSIONS: CH measurement is practical in young children because this is when myopia undergoes its most rapid progression. Prospective follow-up of this cohort at high risk for myopia is under way to determine whether low CH is predictive, or a consequence, of long AL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare outcomes between adjustable spectacles and conventional methods for refraction in young people. DESIGN: Cross sectional study. SETTING: Rural southern China. PARTICIPANTS: 648 young people aged 12-18 (mean 14.9 (SD 0.98)), with uncorrected visual acuity ≤ 6/12 in either eye. INTERVENTIONS: All participants underwent self refraction without cycloplegia (paralysis of near focusing ability with topical eye drops), automated refraction without cycloplegia, and subjective refraction by an ophthalmologist with cycloplegia. MAIN OUTCOME MEASURES: Uncorrected and corrected vision, improvement of vision (lines on a chart), and refractive error. RESULTS: Among the participants, 59% (384) were girls, 44% (288) wore spectacles, and 61% (393/648) had 2.00 dioptres or more of myopia in the right eye. All completed self refraction. The proportion with visual acuity ≥ 6/7.5 in the better eye was 5.2% (95% confidence interval 3.6% to 6.9%) for uncorrected vision, 30.2% (25.7% to 34.8%) for currently worn spectacles, 96.9% (95.5% to 98.3%) for self refraction, 98.4% (97.4% to 99.5%) for automated refraction, and 99.1% (98.3% to 99.9%) for subjective refraction (P = 0.033 for self refraction v automated refraction, P = 0.001 for self refraction v subjective refraction). Improvements over uncorrected vision in the better eye with self refraction and subjective refraction were within one line on the eye chart in 98% of participants. In logistic regression models, failure to achieve maximum recorded visual acuity of 6/7.5 in right eyes with self refraction was associated with greater absolute value of myopia/hyperopia (P<0.001), greater astigmatism (P = 0.001), and not having previously worn spectacles (P = 0.002), but not age or sex. Significant inaccuracies in power (≥ 1.00 dioptre) were less common in right eyes with self refraction than with automated refraction (5% v 11%, P<0.001). CONCLUSIONS: Though visual acuity was slightly worse with self refraction than automated or subjective refraction, acuity was excellent in nearly all these young people with inadequately corrected refractive error at baseline. Inaccurate power was less common with self refraction than automated refraction. Self refraction could decrease the requirement for scarce trained personnel, expensive devices, and cycloplegia in children's vision programmes in rural China.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The World Health Organization estimates that 13 million children aged 5-15 years worldwide are visually impaired from uncorrected refractive error. School vision screening programs can identify and treat or refer children with refractive error. We concentrate on the findings of various screening studies and attempt to identify key factors in the success and sustainability of such programs in the developing world. We reviewed original and review articles describing children's vision and refractive error screening programs published in English and listed in PubMed, Medline OVID, Google Scholar, and Oxford University Electronic Resources databases. Data were abstracted on study objective, design, setting, participants, and outcomes, including accuracy of screening, quality of refractive services, barriers to uptake, impact on quality of life, and cost-effectiveness of programs. Inadequately corrected refractive error is an important global cause of visual impairment in childhood. School-based vision screening carried out by teachers and other ancillary personnel may be an effective means of detecting affected children and improving their visual function with spectacles. The need for services and potential impact of school-based programs varies widely between areas, depending on prevalence of refractive error and competing conditions and rates of school attendance. Barriers to acceptance of services include the cost and quality of available refractive care and mistaken beliefs that glasses will harm children's eyes. Further research is needed in areas such as the cost-effectiveness of different screening approaches and impact of education to promote acceptance of spectacle-wear. School vision programs should be integrated into comprehensive efforts to promote healthy children and their families.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wearable devices performing advanced bio-signal analysis algorithms are aimed to foster a revolution in healthcare provision of chronic cardiac diseases. In this context, energy efficiency is of paramount importance, as long-term monitoring must be ensured while relying on a tiny power source. Operating at a scaled supply voltage, just above the threshold voltage, effectively helps in saving substantial energy, but it makes circuits, and especially memories, more prone to errors, threatening the correct execution of algorithms. The use of error detection and correction codes may help to protect the entire memory content, however it incurs in large area and energy overheads which may not be compatible with the tight energy budgets of wearable systems. To cope with this challenge, in this paper we propose to limit the overhead of traditional schemes by selectively detecting and correcting errors only in data highly impacting the end-to-end quality of service of ultra-low power wearable electrocardiogram (ECG) devices. This partition adopts the protection of either significant words or significant bits of each data element, according to the application characteristics (statistical properties of the data in the application buffers), and its impact in determining the output. The proposed heterogeneous error protection scheme in real ECG signals allows substantial energy savings (11% in wearable devices) compared to state-of-the-art approaches, like ECC, in which the whole memory is protected against errors. At the same time, it also results in negligible output quality degradation in the evaluated power spectrum analysis application of ECG signals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a new selective multi-carrier index keying in orthogonal frequency division multiplexing (OFDM) systems that opportunistically modulate both a small subset of sub-carriers and their indices. Particularly, we investigate the performance enhancement in two cases of error propagation sensitive and compromised deviceto-device (D2D) communications. For the performance evaluation, we focus on analyzing the error propagation probability (EPP) introducing the exact and upper bound expressions on the detection error probability, in the presence of both imperfect and perfect detection of active multi-carrier indices. The average EPP results in closedform are generalized for various fading distribution using the moment generating function, and our numerical results clearly show that the proposed approach is desirable for reliable and energy-efficient D2D applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os sistemas distribuídos embarcados (Distributed Embedded Systems – DES) têm sido usados ao longo dos últimos anos em muitos domínios de aplicação, da robótica, ao controlo de processos industriais passando pela aviónica e pelas aplicações veiculares, esperando-se que esta tendência continue nos próximos anos. A confiança no funcionamento é uma propriedade importante nestes domínios de aplicação, visto que os serviços têm de ser executados em tempo útil e de forma previsível, caso contrário, podem ocorrer danos económicos ou a vida de seres humanos poderá ser posta em causa. Na fase de projecto destes sistemas é impossível prever todos os cenários de falhas devido ao não determinismo do ambiente envolvente, sendo necessária a inclusão de mecanismos de tolerância a falhas. Adicionalmente, algumas destas aplicações requerem muita largura de banda, que também poderá ser usada para a evolução dos sistemas, adicionandolhes novas funcionalidades. A flexibilidade de um sistema é uma propriedade importante, pois permite a sua adaptação às condições e requisitos envolventes, contribuindo também para a simplicidade de manutenção e reparação. Adicionalmente, nos sistemas embarcados, a flexibilidade também é importante por potenciar uma melhor utilização dos, muitas vezes escassos, recursos existentes. Uma forma evidente de aumentar a largura de banda e a tolerância a falhas dos sistemas embarcados distribuídos é a replicação dos barramentos do sistema. Algumas soluções existentes, quer comerciais quer académicas, propõem a replicação dos barramentos para aumento da largura de banda ou para aumento da tolerância a falhas. No entanto e quase invariavelmente, o propósito é apenas um, sendo raras as soluções que disponibilizam uma maior largura de banda e um aumento da tolerância a falhas. Um destes raros exemplos é o FlexRay, com a limitação de apenas ser permitido o uso de dois barramentos. Esta tese apresentada e discute uma proposta para usar a replicação de barramentos de uma forma flexível com o objectivo duplo de aumentar a largura de banda e a tolerância a falhas. A flexibilidade dos protocolos propostos também permite a gestão dinâmica da topologia da rede, sendo o número de barramentos apenas limitado pelo hardware/software. As propostas desta tese foram validadas recorrendo ao barramento de campo CAN – Controller Area Network, escolhido devido à sua grande implantação no mercado. Mais especificamente, as soluções propostas foram implementadas e validadas usando um paradigma que combina flexibilidade com comunicações event-triggered e time-triggered: o FTT – Flexible Time- Triggered. No entanto, uma generalização para CAN nativo é também apresentada e discutida. A inclusão de mecanismos de replicação do barramento impõe a alteração dos antigos protocolos de replicação e substituição do nó mestre, bem como a definição de novos protocolos para esta finalidade. Este trabalho tira partido da arquitectura centralizada e da replicação do nó mestre para suportar de forma eficiente e flexível a replicação de barramentos. Em caso de ocorrência de uma falta num barramento (ou barramentos) que poderia provocar uma falha no sistema, os protocolos e componentes propostos nesta tese fazem com que o sistema reaja, mudando para um modo de funcionamento degradado. As mensagens que estavam a ser transmitidas nos barramentos onde ocorreu a falta são reencaminhadas para os outros barramentos. A replicação do nó mestre baseia-se numa estratégia líder-seguidores (leaderfollowers), onde o líder (leader) controla todo o sistema enquanto os seguidores (followers) servem como nós de reserva. Se um erro ocorrer no nó líder, um dos nós seguidores passará a controlar o sistema de uma forma transparente e mantendo as mesmas funcionalidades. As propostas desta tese foram também generalizadas para CAN nativo, tendo sido para tal propostos dois componentes adicionais. É, desta forma possível ter as mesmas capacidades de tolerância a falhas ao nível dos barramentos juntamente com a gestão dinâmica da topologia de rede. Todas as propostas desta tese foram implementadas e avaliadas. Uma implementação inicial, apenas com um barramento foi avaliada recorrendo a uma aplicação real, uma equipa de futebol robótico onde o protocolo FTT-CAN foi usado no controlo de movimento e da odometria. A avaliação do sistema com múltiplos barramentos foi feita numa plataforma de teste em laboratório. Para tal foi desenvolvido um sistema de injecção de faltas que permite impor faltas nos barramentos e nos nós mestre, e um sistema de medida de atrasos destinado a medir o tempo de resposta após a ocorrência de uma falta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este artigo apresenta um sistema automático de aquisição de dados com aplicação na monitorização da qualidade da água, não só do mar mas também de rios, lagos e lagoas. É um instrumento ambiental bastante útil, baseado numa estação de medida situada numa bóia que envia os dados via GSM para uma estação em Terra.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Refletindo a importância actual da qualidade do ambiente urbano na sustentabilidade global do planeta, há uma tendência crescente em reconhecer a importância dos espaços verdes na zonas urbanes e como uma das componentes essenciais da morfologia urbana.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new rate-control algorithm for live video streaming over wireless IP networks, which is based on selective frame discarding. In the proposed mechanism excess 'P' frames are dropped from the output queue at the sender using a congestion estimate based on packet loss statistics obtained from RTCP feedback and from the Data Link (DL) layer. The performance of the algorithm is evaluated through computer simulation. This paper also presents a characterisation of packet losses owing to transmission errors and congestion, which can help in choosing appropriate strategies to maximise the video quality experienced by the end user. Copyright © 2007 Inderscience Enterprises Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Joint Video Team, composed by the ISO/IEC Moving Picture Experts Group (MPEG) and the ITU-T Video Coding Experts Group (VCEG), has standardized a scalable extension of the H.264/AVC video coding standard called Scalable Video Coding (SVC). H.264/SVC provides scalable video streams which are composed by a base layer and one or more enhancement layers. Enhancement layers may improve the temporal, the spatial or the signal-to-noise ratio resolutions of the content represented by the lower layers. One of the applications, of this standard is related to video transmission in both wired and wireless communication systems, and it is therefore important to analyze in which way packet losses contribute to the degradation of quality, and which mechanisms could be used to improve that quality. This paper provides an analysis and evaluation of H.264/SVC in error prone environments, quantifying the degradation caused by packet losses in the decoded video. It also proposes and analyzes the consequences of QoS-based discarding of packets through different marking solutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de mestrado integrado em Engenharia da Energia e do Ambiente, apresentada à Universidade de Lisboa, através da Faculdade de Ciências, 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we carry out a detailed performance analysis of a novel blind-source-seperation (BSS) based DSP algorithm that tackles the carrier phase synchronization error problem. The results indicate that the mismatch can be effectively compensated during the normal operation as well as in the rapidly changing environments. Since the compensation is carried out before any modulation specific processing, the proposed method works with all standard modulation formats and lends itself to efficient real-time custom integrated hardware or software implementations.