888 resultados para Edge detection method
Resumo:
The detection of acidophilic microorganisms from mining environments by culture methods is time consuming and unreliable. Several PCR approaches were developed to amplify small-subunit rRNA sequences from the DNA of six bacterial phylotypes associated with acidic mining environments, permitting the detection of the target DNA at concentrations as low as 10 fg.
Resumo:
Background/Aims: While laboratory methods for the detection of testicular tissue are well standardized, currently there is no available test to demonstrate the presence of ovarian tissue. We evaluated the effectiveness of gonadal stimulation with luteinizing hormone (LH)/follicle-stimulating hormone (FSH) for the detection of ovarian tissue in patients with disorders of sex development (DSD). Methods: Ten patients with congenital adrenal hyperplasia (CAH) as ovarian-positive controls, 10 with cryptorchidism (ovarian-negative controls), 13 patients with DSD of no defined etiology and 7 patients with ovotesticular DSD (true hermaphroditism, TH) were included in the study. They underwent a daily injection of both LH and FSH on 3 consecutive days. LH, FSH, estradiol, testosterone and inhibin A were measured before treatment, 24 h after the 1st dose and 24 h after the 3rd dose. Results: Estradiol increased in all CAH and TH patients, with a median value of 155.1 and 92.6 pg/ml, respectively, after the 3rd injection. Inhibin A also increased in all CAH and TH patients, with a median value of 70.4 and 32.2 pg/ml, respectively, after the 3rd injection. There was no change in these hormones in the other groups. Conclusion: The LH/FSH stimulation test might be a useful method to detect the presence of ovarian tissue. Copyright (C) 2009 S. Karger AG, Basel
Resumo:
Since circulating leukocytes, mainly B and T cells, continuously maintain vigilant and comprehensive immune surveillance, these cells could be used as reporters for signs of infection or other pathologies, including cancer. Activated lymphocyte clones trigger a sensitive transcriptional response, which could be identified by gene expression profiling. To assess this hypothesis, we conducted microarray analysis of the gene expression profile of lymphocytes isolated from immunocompetent BALB/c mice subcutaneously injected with different numbers of tumorigenic B61 fibrosarcoma cells. Flow cytometry demonstrated that the number of circulating T (CD3(+)CD4(+) or CD3(+)CD8(+)) or B (CD19(+)) cells did not change. However, the lymphocytes isolated from tumor cell-injected animals expressed a unique transcriptional profile that was identifiable before the development of a palpable tumor mass. This finding demonstrates that the transcriptional response appears before alterations in the main lymphocyte subsets and that the gene expression profile of peripheral lymphocytes can serve as a sensitive and accurate method for the early detection of cancer. Exp Biol Med 234:802-812, 2009
Resumo:
Background: Spinal muscular atrophy is a common autosomal recessive neuromuscular disorder caused by mutations in the SMN1 gene. Identification of spinal muscular atrophy carriers has important implications for individuals with a family history of the disorder and for genetic counseling. The aim of this study was to determine the frequency of carriers in a sample of the nonconsanguineous Brazilian population by denaturing high-performance liquid chromatography (DHPLC). Methods: To validate the method, we initially determined the relative quantification of DHPLC in 28 affected patients (DHPLC values: 0.00) and 65 parents (DHPLC values: 0.49-0.69). Following quantification, we studied 150 unrelated nonconsanguineous healthy individuals from the general population. Results: Four of the 150 healthy individuals tested (with no family history of a neuromuscular disorder) presented a DHPLC value in the range of heterozygous carriers (0.6-0.68). Conclusions: Based on these results, we estimated there is a carrier frequency of 2.7% in the nonconsanguineous Brazilian population, which is very similar to other areas of the world where consanguineous marriage is not common. This should be considered in the process of genetic counseling and risk calculations. Copyright (C) 2011 S. Karger AG, Basel
Resumo:
Background Imunoglobulin (Ig) and T cell receptor (TCR) gene rearrangements function as specific markers for minimal residual disease (MRD) which is one of the best predictors of outcome in childhood acute lymphoblastic leukemia (ALL) We recently reported on the prognostic value of MRD during the induction of remission through a simplified PCR method Here we report on gene rearrangement frequencies and offer guidelines for the application of the technique Procedure Two hundred thirty three children had DNA extracted from bone marrow Ig and TCR gene rearrangements were amplified using consensus primers and conventional PCR PCR products were submitted to homo/heteroduplex analysis A computer program was designed to define combinations of targets for clonal detection using a minimum set of primers and reactions Results At least one clonal marker could be detected in 98% of the patients and two markers in approximately 80% The most commonly rear ringed genes in precursor B cell ALL were IgH (75%) TCRD (59%) IgK (55%), and TCRG (54%) The most commonly rearranged genes for TALL were TCRG (100%) and TCRD (24%) The sensitivity of primers was limited to the detection of 1 leukemic cell among 100 normal cells Conclusions We propose that eight PCR reactions per ALL subtype would allow for the detection of two markers in most cases In addition these reactions ire suitable for MRD monitoring especially when aiming the selection of patients with high MRD levels (>= 10(-2)) at the end of induction therapy Such an approach would be very useful in centers with limited financial resources Pediatr Blood Cancer 2010 55 1278-1286 (C) 2010 Wiley Liss Inc
Resumo:
Functional MRI (fMRI) data often have low signal-to-noise-ratio (SNR) and are contaminated by strong interference from other physiological sources. A promising tool for extracting signals, even under low SNR conditions, is blind source separation (BSS), or independent component analysis (ICA). BSS is based on the assumption that the detected signals are a mixture of a number of independent source signals that are linearly combined via an unknown mixing matrix. BSS seeks to determine the mixing matrix to recover the source signals based on principles of statistical independence. In most cases, extraction of all sources is unnecessary; instead, a priori information can be applied to extract only the signal of interest. Herein we propose an algorithm based on a variation of ICA, called Dependent Component Analysis (DCA), where the signal of interest is extracted using a time delay obtained from an autocorrelation analysis. We applied such method to inspect functional Magnetic Resonance Imaging (fMRI) data, aiming to find the hemodynamic response that follows neuronal activation from an auditory stimulation, in human subjects. The method localized a significant signal modulation in cortical regions corresponding to the primary auditory cortex. The results obtained by DCA were also compared to those of the General Linear Model (GLM), which is the most widely used method to analyze fMRI datasets.
Resumo:
Objective: To propose an electronic method for sensitivity evaluation in leprosy and to compare it to the Semmes-Weinstein monofilaments. Methods:Thirty patients attending the Dermatology outpatient clinic of HCFMRP-USP were consecutively evaluated by both the electronic aesthesiometer and Semmes-Weinstein monofilaments on hand and foot test points. The intraclass correlation coefficient (ICC) was calculated to determine the variability of the electronic measures and the Kappa coefficient was calculated to determine the agreement between methods according to their categories (altered and non-altered tactile sensitivity). Results: The ICC was approximately 1, demonstrating repeatability. The Kappa coefficient showed more than 75 and 63% agreement on the hand and foot points, respectively. The mean agreement between the 2 methods for the 7 points of the right and left hand was 77.14 and 75.71%, respectively. The mean agreement for all 10 points was 74.33 and 63.66% on the right and left foot, respectively. In cases of disagreement the detection of altered tactile sensitivity by the electronic esthesiometer on the right and left foot was 90.91 and 84.25%, respectively, with no detection by the monofilaments. Conclusion: The results suggest that the electronic esthesiometer is a reliable and easy application, capable of evaluating alterations of tactile sensitivity in leprosy patients. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Homozygous familial hypercholesterolemia (HoFH) is a rare disorder characterized by the early onset of atherosclerosis, often at the ostia of coronary arteries. In this study we document for the first time that aortic and coronary atherosclerosis can be detected using 64 slice multiple detector row computed tomographic coronary angiography (CTCA). We studied five HoFH patients (three females, two males, mean age 19.8 +/- 2.9 years, age range 15-23 years, with a mean low density lipoprotein (LDL) cholesterol 618 +/- 211 mg/dL) using 64 slice CTCA. None of the patients showed evidence of ischemia with standard exercise testing. Calcified and mixed atherosclerotic plaques adjacent to or compromising the coronary artery ostia were found in all study subjects. Coronary plaques causing significant obstruction were found in one patient, who had previously undergone coronary artery bypass surgery and aortic valve replacement. Two other patients were noted to have non-obstructive calcified, mixed and non-calcified coronary artery plaques. Our data suggest that CTCA could be a useful non-invasive method for detection of early aortic and coronary atherosclerosis specifically affecting the coronary ostia in HoFH subjects. (c) 2007 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Background: Herpesviruses may be related to the etiology of aggressive periodontitis (AgP) and chronic periodontitis (CP) by triggering periodontal destruction or by increasing the risk for bacterial infection. This case-control study evaluated the presence of herpes simplex virus type 1 (HSV-1), Epstein-Barr virus type 1 (EBV-1), human cytomegalovirus (HCMV), Aggregatibacter actinomycetemcomitans (previously Actinobacillus actinomycetemcomitans), Porphyromonas gingivalis, Prevotella intermedia, and Tannerella forsythia (previously T. forsythensis) in patients with generalized AgP (AgP group), CP (CP group), or gingivitis (G group) and in healthy individuals (C group). Methods: Subgingival plaque samples were collected with paper points from 30 patients in each group. The nested polymerase chain reaction (PCR) method was used to detect HSV-1, EBV-1, and HCMV. Bacteria were identified by 16S rRNA-based PCR. Results: HSV-1, HCMV, and EBV-1 were detected in 86.7%, 46.7%, and 33.3% of the AgP group, respectively; in 40.0%, 50.0%, and 46.7% of the CP group, respectively; in 53.3%, 40.0%, and 20.0% of the G group, respectively; and in 20.0%, 56.7%, and 0.0% of the C group, respectively. A. actinomycetemcomitans was detected significantly more often in the AgP group compared to the other groups (P<0.005). P. gingivalis and T. forsythia were identified more frequently in AgP and CP groups, and AgP, CP, and G groups had higher frequencies of P. intermedia compared to the C group. Conclusion: In Brazilian patients, HSV-1 and EBV-1, rather than HCMV, were more frequently associated with CP and AgP. J Periodontol 2008;79:2313-2321.
Resumo:
Laboratory diagnosis of human respiratory syncytial virus (hRSV) infections has traditionally been performed by virus isolation in cell culture and the direct fluorescent-antibody assay (DFA). Reverse transcriptase PCR (RT-PCR) is now recognized as a sensitive and specific alternative for detection of hRSV in respiratory samples. Using the LightCycler instrument, we developed a rapid RT-PCR assay for the detection of hRSV (the LC-RT-PCR) with a pair of hybridization probes that target the hRSV L gene. In the present study, 190 nasopharyngeal aspirate samples from patients with clinically recognized respiratory tract infections were examined for hRSV. The results were then compared to the results obtained with a testing algorithm that combined DFA and a culture-augmented DFA (CA-DFA) assay developed in our laboratory. hRSV was detected in 77 (41%) specimens by LC-RT-PCR and in 75 (39%) specimens by the combination of DFA and CA-DFA. All specimens that were positive by the DFA and CA-DFA testing algorithm were positive by the LC-RT-PCR. The presence of hRSV RNA in the two additional LC-RT-PCR-positive specimens was confirmed by a conventional RT-PCR method that targets the hRSV N gene. The sensitivity of LC-RT-PCR was 50 PFU/ml; and this, together with its high specificity and rapid turnaround time, makes the LC-RT-PCR suitable for the detection of hRSV in clinical specimens.
Resumo:
Using the Roche LightCycler we developed a real-time reverse transcriptase polymerase chain reaction (RT-PCR) assay using the Influenza A LightCycler RT-PCR (FA-LC-RTPCR) for the rapid detection of Influenza A. The assay was used to examine 178 nasopharyngeal aspirate (NPA) samples, from patients with clinically recognised respiratory tract infection, for the presence of Influenza A RNA. The results were then compared to a testing algorithm combining direct immunofluorescent assy (DFA) and a culture augmented DFA (CA-DFA) assay. In total, 76 (43%) specimens were positive and 98 (55%) specimens were negative by both the FA-LC-RTPCR and the DFA and CA-DFA algorithm. In addition, the FA-LC-RTPCR detected a further 4 (2%) positive specimens, which were confirmed by a conventional RT-PCR method. The high level of sensitivity and specificity, combined with the rapid turnaround time for results, makes the LC-RT-PCR assay suitable for the detection of Influenza A in clinical specimens.
Resumo:
Detection of a circumferential crack in a hollow section beam is investigated using coupled response measurements. The crack section is represented by a local flexibility matrix connecting two undamaged beam segments. This matrix defines the relationship between the displacements and forces across the crack section and is derived by applying fundamental fracture mechanics theory. The suitability of the mode coupling methodology is first demonstrated analytically. Laboratory test results are then presented for circular hollow section beams with artificially generated cracks of varying severity. It is shown that this method has the potential as a damage detection tool for mechanical structures. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
In this paper we present a method for real-time detection and tracking of people in video captured by a depth camera. For each object to be assessed, an ordered sequence of values that represents the distances between its center of mass to the boundary points is calculated. The recognition is based on the analysis of the total distance value between the above sequence and some pre-defined human poses, after apply the Dynamic Time Warping. This similarity approach showed robust results in people detection.
Resumo:
Structures experience various types of loads along their lifetime, which can be either static or dynamic and may be associated to phenomena of corrosion and chemical attack, among others. As a consequence, different types of structural damage can be produced; the deteriorated structure may have its capacity affected, leading to excessive vibration problems or even possible failure. It is very important to develop methods that are able to simultaneously detect the existence of damage and to quantify its extent. In this paper the authors propose a method to detect and quantify structural damage, using response transmissibilities measured along the structure. Some numerical simulations are presented and a comparison is made with results using frequency response functions. Experimental tests are also undertaken to validate the proposed technique. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Mestrado em Medicina Nuclear.