921 resultados para Conical tubes


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this work was to evaluate the spatial distribution of thrips in different crops, and the correlation between meterological parameters and the flight movements of this pest, using immunomarking. The experiment was conducted in cultivated areas, with tomato (Solanum lycopersicum), potato (Solanum tuberosum), and onion (Allium cepa); and non-cultivated areas, with weedy plants. The areas with tomato (100 days), potato (20 days), and weeds were sprayed with casein, albumin, and soy milk, respectively, to mark adult thrips; however, the areas with onion (50 days) and tomato (10 days) were not sprayed. Thrips were captured with georeferenced blue sticky traps, transferred into tubes, and identified by treatment area with the Elisa test. The dependence between the samples and the capture distance was determined using geostatistics. Meteorlogical parameters were correlated with thrips density in each area. The three protein types used for immunomarking were detected in different proportions in the thrips. There was a correlation between casein-marked thrips and wind speed. The thrips flew a maximum distance of 3.5 km and dispersed from the older (tomato) to the younger crops (potato). The immunomarking method is efficient to mark large quantities of thrips.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tämän diplomityön päämääränä on tehdä prosessiteollisuuden tarpeisiin Excel-taulukkolaskentaohjelmassa toimiva putkilämmönsiirtimen mitoitusohjelma. Prosessiteollisuudessa lämmönvaihtimien toimintaympäristöt ja olosuhteet vaihtelevat merkittävästi ja niinpä jokaisen vaihtimen suunnittelu ja mitoitus on toteutettava tapauskohtaisesti. Työssä käsitellään rekuperatiivisen ristivirtaputkilämmönvaihtimen yleinen lämpötekninen mitoitus sisältäen putken sisäpinnalle tapahtuvan mahdollisen lauhtumisen. Mitoitettava vaihdinkoostuu pystysuorista putkista, joissa lämmin ja kostea ilma virtaa putkien sisäpuolella ja kylmä kuiva ilma vaippapuolella vaakasuoraan. Vaihdinmateriaalina käytetään ruostumatonta AISI 304 -tai haponkestävää AISI 316 terästä. Kuuman ilman tila vaihtelee tarkasteltavan kohteen mukaan. Paperiteollisuuden kuivausyksiköiltä poistuva ilma on usein lämmintä ja kosteaa, ja infrakuivaimilta poistuva ilma on kuumaa. Mitoitettavalle lämmönvaihtimelle tulevan kuuman ilman lämpötila tapauksesta riippuen voi vaihdella 30°C, maksimissaan +300°C:een saakka, vesisisällön ollessa välillä 0,010...0,200 kg/kg ki tai jopa tämän ylikin. Vaihtimen mitoitus perustuu energiataseyhtälöiden käyttöön. Laskennassa määritetään vaihtimen pintalämpötila sekä mahdollinen kostean ilman lauhtuminen putken sisäpinnalle. Lisäksi teoria käsittää molempien virtausten tilanmuutosten laskennan. Työssä on esitetty esimerkkilaskelma, jossa on laskettu ilma- kostea ilma lämmönsiirrinkonstruktio. Esimerkissä on tarkasteltu vaihtimen hyötysuhdetta, virtausten lämpö- ja kosteuskäyttäytymistä ulkoilman lämpötilan funktiona. Ohjelmasta saadaan tulostettua mitoitettavanvaihtimen dimensiot; putkien lukumäärät syvyys- ja pituussuunnassa sekä kokonaisputkilukumäärä, putkien väliset etäisyydet toisiinsa nähden sekä syvyys, että pituussuunnassa, putkipituus ja putken sisä- ja ulkohalkaisijat. Nämä tiedot suunnittelija itse syöttää ohjelmalle alkuarvoina. Laskettuna tietona ohjelma antaa molempien virtausten poistolämpötilat, kuuman ilman poistuvan absoluuttisen kosteuden, kondenssivesimäärän, vaihtimen tehon ja painehäviöt vaippa- ja putkipuolelle. Lisäksi ohjelma laskee kuuman ilman ominaisentalpiat vaihtimen sisään- ja ulostulossa. Tämä mahdollistaa ilman tilapisteiden piirtämisen Mollier-piirrokseen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Automatització d’una màquina que permeti la fabricació de tubs mitjançant actuadors mecànics que actuen en sintonia amb l’aparellatge elèctric i electrònic responent a un programa realitzat en “Step 7” inserit en un PLC de la sèrie S7-300, el qual respon a una aplicació SCADA per a l’òptima visualització, seguiment i configuració del procés

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In 1959, Swerdlow reported a case of a 27-year-old woman with a pelvic tumour that seemed to arise from the peritoneum, in the presence of normal ovaries, fallopian tubes and uterus, and that was histologically similar to papillary serous carcinoma of the ovary [52]. Since then several authors have described this disease using different names, such as extraovarian primary peritoneal carcinoma (EOPPC), peritoneal papillary serous carcinoma, peritoneal adenocarcinoma of Müllerian type, serous surface papillary carcinoma, normal sized ovary carcinoma syndrome, peritoneal mesothelioma, and primary peritoneal carcinoma. This illustrates the confusion about definition, histogenesis and clinicopathologic features of this entity. In 1993, in an attempt to sort out these confounding variables, the Gynecologic Oncology Group (GOG) developed criteria to define EOPPC: - Both ovaries must be either physiologically normal in size or enlarged by a benign process. - The involvement in extraovarian sites must be greater than the involvement on the surface of either ovary. - Microscopically, the ovarian component must be one of the following: non existent; confined to ovarian surface epithelium with no evidence of cortical invasion; involving ovarian surface epithelium and underlying cortical stroma but with tumour size less than 5x5mm within ovarian substance with or without surface disease. The histological and cytological characteristics of the tumour must be predominantly of the serous type that is similar or identical to ovarian serous adenocarcinoma of any grade [8, 55].

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Siiloja käytetään jauhemaisten ja rakeisten aineiden varastointiin ja annosteluun maataloudessa sekä mm. lasi-, laasti- ja tasoiteteollisuudessa. Tällaiset laitokset toimitetaan usein kokonaistoimituksina, joissa tavanomaisten teräsrakenteiden kustannusvaikutus voi olla jopa 30 % koko toimituksen arvosta. Niinpä osaltaan siilojen tehokkaalla mitoituksella ja erilaisiarakenneratkaisuja vertailemalla voidaan alentaa toimitusten kokonaiskustannuksia. Tässä diplomityössä perehdyttiin siilojen rakenteisiin ja niiden lujuustekniseen mitoitukseen etenkin tuentaratkaisujen osalta. Mitoituksen osalta työssä perehdyttiin pääasiassa uusiin Eurooppalaisiin standardeihin SFS-EN 1991-4 ja SFS-EN 1993-4-1. Niiden mukaan määritetään mitoituskuormat sekä tehdään lujuustekninen mitoitus. Työn tuloksena laadittiin Microsoft Excel -pohjainen mitoitusohjelma, jolla voidaan nopeasti mitoittaa siilojen olennaisimmat teräsrakenteet. Ohjelmalla voidaan määrittää mitoitus koskien siilon lieriön ja kartion seinämiä sekä tuentaratkaisuja. Ohjelma nopeuttaa erityisesti tarjousvaiheen suunnittelua ja antaa pohjan varsinaiselle siilojen yksityiskohtaiselle mitoittamiselle ja suunnittelulle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis gives an overview of the validation process for thermal hydraulic system codes and it presents in more detail the assessment and validation of the French code CATHARE for VVER calculations. Three assessment cases are presented: loop seal clearing, core reflooding and flow in a horizontal steam generator. The experience gained during these assessment and validation calculations has been used to analyze the behavior of the horizontal steam generator and the natural circulation in the geometry of the Loviisa nuclear power plant. The cases presented are not exhaustive, but they give a good overview of the work performed by the personnel of Lappeenranta University of Technology (LUT). Large part of the work has been performed in co-operation with the CATHARE-team in Grenoble, France. The design of a Russian type pressurized water reactor, VVER, differs from that of a Western-type PWR. Most of thermal-hydraulic system codes are validated only for the Western-type PWRs. Thus, the codes should be assessed and validated also for VVER design in order to establish any weaknesses in the models. This information is needed before codes can be used for the safety analysis. Theresults of the assessment and validation calculations presented here show that the CATHARE code can be used also for the thermal-hydraulic safety studies for VVER type plants. However, some areas have been indicated which need to be reassessed after further experimental data become available. These areas are mostly connected to the horizontal stem generators, like condensation and phase separation in primary side tubes. The work presented in this thesis covers a large numberof the phenomena included in the CSNI code validation matrices for small and intermediate leaks and for transients. Also some of the phenomena included in the matrix for large break LOCAs are covered. The matrices for code validation for VVER applications should be used when future experimental programs are planned for code validation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An accidental burst of a pressure vessel is an uncontrollable and explosion-like batch process. In this study it is called an explosion. The destructive effectof a pressure vessel explosion is relative to the amount of energy released in it. However, in the field of pressure vessel safety, a mutual understanding concerning the definition of explosion energy has not yet been achieved. In this study the definition of isentropic exergy is presented. Isentropic exergy is the greatest possible destructive energy which can be obtained from a pressure vessel explosion when its state changes in an isentropic way from the initial to the final state. Finally, after the change process, the gas has similar pressure and flow velocity as the environment. Isentropic exergy differs from common exergy inthat the process is assumed to be isentropic and the final gas temperature usually differs from the ambient temperature. The explosion process is so fast that there is no time for the significant heat exchange needed for the common exergy.Therefore an explosion is better characterized by isentropic exergy. Isentropicexergy is a characteristic of a pressure vessel and it is simple to calculate. Isentropic exergy can be defined also for any thermodynamic system, such as the shock wave system developing around an exploding pressure vessel. At the beginning of the explosion process the shock wave system has the same isentropic exergyas the pressure vessel. When the system expands to the environment, its isentropic exergy decreases because of the increase of entropy in the shock wave. The shock wave system contains the pressure vessel gas and a growing amount of ambient gas. The destructive effect of the shock wave on the ambient structures decreases when its distance from the starting point increases. This arises firstly from the fact that the shock wave system is distributed to a larger space. Secondly, the increase of entropy in the shock waves reduces the amount of isentropic exergy. Equations concerning the change of isentropic exergy in shock waves are derived. By means of isentropic exergy and the known flow theories, equations illustrating the pressure of the shock wave as a function of distance are derived. Amethod is proposed as an application of the equations. The method is applicablefor all shapes of pressure vessels in general use, such as spheres, cylinders and tubes. The results of this method are compared to measurements made by various researchers and to accident reports on pressure vessel explosions. The test measurements are found to be analogous with the proposed method and the findings in the accident reports are not controversial to it.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study focuses on two effects of the presence of a noncondensable gas on the thermal-hydraulic behavior of thecoolant of the primary circuit of a nuclear reactor in the VVER-440 geometry inabnormal situations. First, steam condensation with the presence of air was studied in the horizontal tubes of the steam generator (SG) of the PACTEL test facility. The French thermal-hydraulic CATHARE code was used to study the heat transfer between the primary and secondary side in conditions derived from preliminary experiments performed by VTT using PACTEL. In natural circulation and single-phase vapor conditions, the injection of a volume of air, equivalent to the totalvolume of the primary side of the SG at the entrance of the hot collector, did not stop the heat transfer from the primary to the secondary side. The calculated results indicate that air is located in the second half-length (from the mid-length of the tubes to the cold collector) in all the tubes of the steam generator The hot collector remained full of steam during the transient. Secondly, the potential release of the nitrogen gas dissolved in the water of the accumulators of the emergency core coolant system of the Loviisa nuclear power plant (NPP) was investigated. The author implemented a model of the dissolution and release ofnitrogen gas in the CATHARE code; the model created by the CATHARE developers. In collaboration with VTT, an analytical experiment was performed with some components of PACTEL to determine, in particular, the value of the release time constant of the nitrogen gas in the depressurization conditions representative of the small and intermediate break transients postulated for the Loviisa NPP. Such transients, with simplified operating procedures, were calculated using the modified CATHARE code for various values of the release time constant used in the dissolution and release model. For the small breaks, nitrogen gas is trapped in thecollectors of the SGs in rather large proportions. There, the levels oscillate until the actuation of the low-pressure injection pumps (LPIS) that refill the primary circuit. In the case of the intermediate breaks, most of the nitrogen gas is expelled at the break and almost no nitrogen gas is trapped in the SGs. In comparison with the cases calculated without taking into account the release of nitrogen gas, the start of the LPIS is delayed by between 1 and 1.75 h. Applicability of the obtained results to the real safety conditions must take into accountthe real operating procedures used in the nuclear power plant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, equations for the calculation of erosion wear caused by ash particles on convective heat exchanger tubes of steam boilers are presented. Anew, three-dimensional test arrangement was used in the testing of the erosion wear of convective heat exchanger tubes of steam boilers. When using the sleeve-method, three different tube materials and three tube constructions could be tested. New results were obtained from the analyses. The main mechanisms of erosionwear phenomena and erosion wear as a function of collision conditions and material properties have been studied. Properties of fossil fuels have also been presented. When burning solid fuels, such as pulverized coal and peat in steam boilers, most of the ash is entrained by the flue gas in the furnace. In bubbling andcirculating fluidized bed boilers, particle concentration in the flue gas is high because of bed material entrained in the flue gas. Hard particles, such as sharp edged quartz crystals, cause erosion wear when colliding on convective heat exchanger tubes and on the rear wall of the steam boiler. The most important ways to reduce erosion wear in steam boilers is to keep the velocity of the flue gas moderate and prevent channelling of the ash flow in a certain part of the cross section of the flue gas channel, especially near the back wall. One can do this by constructing the boiler with the following components. Screen plates can beused to make the velocity and ash flow distributions more even at the cross-section of the channel. Shield plates and plate type constructions in superheaters can also be used. Erosion testing was conducted with three types of tube constructions: a one tube row, an inline tube bank with six tube rows, and a staggered tube bank with six tube rows. Three flow velocities and two particle concentrations were used in the tests, which were carried out at room temperature. Three particle materials were used: quartz, coal ash and peat ash particles. Mass loss, diameter loss and wall thickness loss measurements of the test sleeves were taken. Erosion wear as a function of flow conditions, tube material and tube construction was analyzed by single-variable linear regression analysis. In developing the erosion wear calculation equations, multi-variable linear regression analysis was used. In the staggered tube bank, erosion wear had a maximum value in a tube row 2 and a local maximum in row 5. In rows 3, 4 and 6, the erosion rate was low. On the other hand, in the in-line tube bank the minimum erosion rate occurred in tube row 2 and in further rows the erosion had an increasing value, so that in a six row tube bank, the maximum value occurred in row 6.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We examined root morphological and functional differences caused by restrictions imposed to vertical growth in the root system of holm oak (Quercus ilex L.) seedlings to assess the consequences of using nursery containers in the development of a confined root system for this species. Thus, root morphological, topological and functional parameters, including hydraulic conductance per leaf unit surface area (K $_{\rm RL})$, were investigated in one-year seedlings cultivated in three PVC tubes differing in length (20, 60 and 100 cm). Longer tubes showed greater projected root area, root volume, total and fine root lengths, specific root length (SRL) and K$_{\rm RL}$ values than did shorter tubes. On the other hand, the length of coarse roots (diameter > 4.5 mm) and the average root diameter were greater in shorter tubes. The strong positive correlation found between K$_{\rm RL}$ and SRL (r=+0.69; P<0.001) indicated that root thickness was inversely related to water flow through the root system. We concluded that root systems developed in longer tubes are more efficient for plant water uptake and, therefore, changes in root pattern produced in standard forest containers (i.e. about 20 cm length) may in fact prevent a proper establishment of the holm oak in the field, particularly in xeric environments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Se ha seguido la evolución de las poblaciones de parasitoides de Cacopsylla pyri (L.) (= Psylla pyri (L.)) en una parcela comercial de peral de la variedad Blanquilla no sometida a tratamientos con productos insecticidas en Lleida. Se recogieron al azar semanalmente unas 150 ninfas de C. pyri desde abril a noviembre de 1991. Las ninfas fueron llevadas al laboratorio y colocadas en brotes de peral. Las momias fueron individualizadas en tubos de cristal hasta la emergencia del adulto del parasitoide. La especie parasitoide más abundante fue el encírtido Trechnites psyllae (Ruschka) (= Metallon psyllae (Ruschka)). También se encontró un encírtido hiperparasitoide, Aphidencyrtus mamitus (Walker) (= Syrphophagus mamitus Walker). Se observó un 18 % de parasitismo en la primera quincena de mayo sobre ninfas de la primera generación de C. pyri, época del año en la que no han hecho su aparición los depredadores de psylla.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El presente trabajo tiene por objetivo principal analizar tres funciones de perfil del fuste sobre tres clones de Populus x euramericana (Canadá Blanco, I-214 y MC) en la Comunidad Foral de Navarra para elaborar una tarifa de cubicación con clasificación de volumen. Para minimizar el efecto de la autocorrelación entre los residuos se emplea una estructura de error continua autorregresiva de orden 2 o de orden 3 en función del clon analizado. Por otra parte, se compara el coeficiente local de forma de cada uno de los clones estudiados mediante dos metodologías: el análisis de la varianza de la estimación individual de dicho coeficiente y el contraste del estadístico de máxima verosimilitud entre ajustes, resultando ser el clon Canadá el más cónico de los tres. Los datos utilizados provienen de 143 chopos de plantaciones coetáneas y con mismo marco de plantación (marco real de 4,5 × 4,5 m).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tässä työssä selostetaan kuumalanka-anemometrin käyttö virtausmittauksissa. Kuumalanka-anemometrilla saadaan mitattua virtausnopeuden ja -suunnan lisäksi nopeusheilahteluja. Mittaustaajuus on tyypillisesti useita kymmeniä tuhansia mittauksia sekunnissa ja signaali on jatkuva. Nykytekniikalla pystytään helposti tallentamaan mittauslaitteistolta saatu viesti tietokoneelle ja muuntamaan se nopeudeksi. Hetkellisten nopeuksien avulla voidaan laskea turbulenttisen virtauksen ominaisuuksia, kuten turbulenssin intensiteetti ja spektri. Kuumalanka-anemometrissa lämmitetään sähköisesti ohutta lankaa, joka on mitattavassa virtauksessa. Langan sähköteho on suunnilleen yhtäsuuri kuin langasta konvektiolla siirtyvä lämpöteho. Tällöin on teoreettisesti mahdollista laskea virtausnopeus lämpötehosta lämmönsiirtokorrelaatioilla. Käytännössä laitteisto joudutaan kuitenkin erikseen kalibroimaan, mutta sähkötehon teoreettista riippuvuutta konvektiosta käytetään hyväksi. Kuumalangan lämmitettävä osuus on tyypillisesti halkaisijaltaan 5 µm ja pituudeltaan noin 1 mm. Sitä käytetään pääasiassa kaasuvirtausten mittaamiseen ja valtaosassa mittauksissa virtausaineena on ilma. Kuumalanka voi olla toteutettu kuumakalvotekniikalla, jossa halkaisijaltaan noin 50 - 70 µm paksuinen kuitu on päällystetty ohuella sähköä johtavalla kalvolla. Kuumakalvoanturin ei tarvitse olla muodoltaan sylinterimäinen, se voi olla mm. kartiomainen tai kiilamainen. Erikoispäällystetyllä kuumakalvoanturilla on mahdollista mitata myös nestevirtauksia. Mitattaessa kaasuvirtauksia kuumakalvon etuna on selvästi parempi kestävyys verrattuna kuumalankaan. Nimitystä kuumalanka-anemometri käytetään yleisesti molemmista anturityypeistä Tämän työn alussa käsitellään sylinterin yli tapahtuvaan virtaukseen liittyvää virtausmekaniikkaa ja lämmönsiirtoa. Anemometrin sähköinen osa, laitteisto ja sen kalibrointi käydään läpi. Langan suuntariippuvuuden laskentaan esitetään tarvittavat yhtälöt. Työssä esitellään kolme laitteistolla tehtyä perusmittausta: anturin kohtauskulman muuttaminen, pyörähdyssymmerisen suihkun nopeuskenttä ja tuulitunnelin rajakerros. Lisäksi esitellään yksi käytännöllinen ja vaativampi mittaus, jossa on mitattu nopeusprofiili radiaalikompressorin diffuusorin loppuosassa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Työssä esisuunniteltiin Kemira Pigments Oy:lle uusi titanyylisulfaatin elektrolyyttinen pelkistyslaitos. Suurin syy uuden laitoksen suunnitteluun oli nykyisen laitoksen aiheuttamat korkeat H2SO4-pitoisuudet pelkistyslaitoksen läheisyydessä. Työn kirjallisuusosassa käsitellään elektrolyysilaitteiston suunnitteluun liittyviä seikkoja ja esitellään titanyylisulfaatin elektrolyyttiseen pelkistykseen liittyvää tutkimustietoa. Ennen uuden laitoksen suunnittelua suoritettiin nykyisellä pelkistyslaitoksella koeajoja, joiden tarkoituksena oli antaa lähtötiedot uuden laitoksen suunnittelulle. Koeajot osoittivat mm., että pelkistys on edullisinta suorittaa alhaisella virrantiheydellä n. 300…400 A/m2 ja vesilaimennuksen avulla anolyytin H2SO4-pitoisuus saadaan säädettyä tasolle, jossa titaani ei saostu. Kärynpoistoyhteisiin asennettujen pesuvesisuuttimien avulla saatiin titaanin saostuminen kärynpoistokanaviin estettyä. Uudesta titanyylisulfaatin elektrolyyttisestä pelkistyslaitoksesta laadittiin mm. seuraavat dokumentit: prosessin virtauskaavio ja ainevirtakenttä, PI-kaavio, layout-kuvat laitoksesta ja sen sijoituksesta sekä rakennepiirros elektrolyysialtaasta. Hankkeelle tehtiin kustannusarvio tarkkuudella ±20 %, jonka loppusummaksi saatiin 1 489 000 €. Laitoksen vuotuisten käyttökustannuksien arvioitiin olevan n. 105 000 €. Investoinnista aiheutuvien vuotuisten annuiteettikustannusten arvioitiin olevan n. 237 000 € 16,3 % korolla.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diplomityön tavoitteena oli tutkia kerrostumien muodostumista voimalaitoskattiloiden lämpöpinnoille ja niiden vaikutusta lämmönsiirtoon. Kerrostumien vaikutusta lämpöpintojen lämpötiloihin tutkittiin kerrostumasondin avulla kierto- ja kerrosleijukattiloissa. Saadun mittausaineiston muodostettiin mittaustilannetta vastaava laskentamalli, jonka avulla pystytään selvittämään voimalaitoksen lämpöpintojen likaantumista käyttöperiodin aikana. Työn alussa tarkasteltiin kerrostumien muodostumismekanismeja lämmönsiirtopinnoille, kerrostumien ominaisuuksia ja virtausympäristön vaikutusta lämmönsiirtoon. Poltossa syntyvä tuhka kiinnittyy eri mekanismeilla kattilan seinille ja lämpöpinnoille riippuen polttoaineesta ja ympäröivistä olosuhteista. Likakerrosten muodostuminen lämmönsiirtimen pinnalle pienentää putkeen siirtyvää lämpövirtaa ja alentaa kattilan hyötysuhdetta. Kerrostumien lämmönjohtumisesta ja mikrorakenteesta on hyvin vähän kokeellisen tietoa, mikä vaikeuttaa reaalisten mallien muodostamista kattilan käyttäytymisestä sen likaantuessa.Työn kokeellisessa osassa tarkasteltiin kahdella eri kattilalla tehtyjä mittauksia. Mittaukset tehtiin kerrostumasondilla, jonka lämmönsiirrosta luotiin laskentamalli SIMULINK-simulointiohjelmalla. Mittaustuloksina saatiin kolmen eri pinnan lämpötilat, jotka muuttuivat kerrostuman ja jäähdytyksen vaikutuksesta. Laskentamallista muokattiin mittaustilanteita vastaava, jolloin lämpötilamuutoksista nähdään likakerroksen ominaisuuksien vaikutus lämmönsiirtoon. Sondista muodostettiin myös FLUENT-malli, jolla tarkasteltiin yksittäisen putken virtauskenttää sekä kahden lähekkäin olevan putken vaikutusta virtaukseen.