912 resultados para Closed loop control systems


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper overviews the field of graphical simulators used for AUV development, presents the taxonomy of these applications and proposes a classification. It also presents Neptune, a multivehicle, real-time, graphical simulator based on OpenGL that allows hardware in the loop simulations

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A long development time is needed from the design to the implementation of an AUV. During the first steps, simulation plays an important role, since it allows for the development of preliminary versions of the control system to be integrated. Once the robot is ready, the control systems are implemented, tuned and tested. The use of a real-time simulator can help closing the gap between off-line simulation and real testing using the already implemented robot. When properly interfaced with the robot hardware, a real-time graphical simulation with a "hardware in the loop" configuration, can allow for the testing of the implemented control system running in the actual robot hardware. Hence, the development time is drastically reduced. These paper overviews the field of graphical simulators used for AUV development proposing a classification. It also presents NEPTUNE, a multi-vehicle, real-time, graphical simulator based on OpenGL that allows hardware in the loop simulations

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper surveys control architectures proposed in the literature and describes a control architecture that is being developed for a semi-autonomous underwater vehicle for intervention missions (SAUVIM) at the University of Hawaii. Conceived as hybrid, this architecture has been organized in three layers: planning, control and execution. The mission is planned with a sequence of subgoals. Each subgoal has a related task supervisor responsible for arranging a set of pre-programmed task modules in order to achieve the subgoal. Task modules are the key concept of the architecture. They are the main building blocks and can be dynamically re-arranged by the task supervisor. In our architecture, deliberation takes place at the planning layer while reaction is dealt through the parallel execution of the task modules. Hence, the system presents both a hierarchical and an heterarchical decomposition, being able to show a predictable response while keeping rapid reactivity to the dynamic environment

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper deals with the problem of identification and semiactive control of smart structures subject to unknown external disturbances such as earthquake, wind, etc. The experimental setup used is a 6-story test structure equipped with shear-mode semiactive magnetorheological actuators being installed in WUSCEEL. The experimental results obtained have verified the effectiveness of the proposed control algorithms

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aquest projecte s’aplica sobre el robot PRIM (Plataforma Robotitzada d’Informació Multimèdia), un robot autònom no humanoide creat el 2004 per Ateneu Informàtic (AI) que permet realitzar trajectòries 2D gràcies a un sistema de tracció format per dues rodes motrius propulsades independentment. La plataforma PRIM és controlada a partir del control predictiu, aquest control es va implementar en un projecte anterior, creat per l’Alexandre Blasco Gutierrez i titulat “Implementació de tècniques MPC (Model Predictiu Control) sobre la plataforma PRIM I”. El que es pretén en aquest projecte és millorar els resultats obtinguts en el passat projecte reformulant la llei de control i analitzar les discrepàncies obtingudes en les metodologies que s’utilitzen per minimitzar la funció de costos a partir de simulacions de trajectòries

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The problem of stability analysis for a class of neutral systems with mixed time-varying neutral, discrete and distributed delays and nonlinear parameter perturbations is addressed. By introducing a novel Lyapunov-Krasovskii functional and combining the descriptor model transformation, the Leibniz-Newton formula, some free-weighting matrices, and a suitable change of variables, new sufficient conditions are established for the stability of the considered system, which are neutral-delay-dependent, discrete-delay-range dependent, and distributeddelay-dependent. The conditions are presented in terms of linear matrix inequalities (LMIs) and can be efficiently solved using convex programming techniques. Two numerical examples are given to illustrate the efficiency of the proposed method

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The H∞ synchronization problem of the master and slave structure of a second-order neutral master-slave systems with time-varying delays is presented in this paper. Delay-dependent sufficient conditions for the design of a delayed output-feedback control are given by Lyapunov-Krasovskii method in terms of a linear matrix inequality (LMI). A controller, which guarantees H∞ synchronization of the master and slave structure using some free weighting matrices, is then developed. A numerical example has been given to show the effectiveness of the method

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L’objectiu d’aquest treball és fer un estudi dels diferents tipus de sistemes de posicionament global que hi ha en el mercat, elegir un mòdul receptor assequible per poder analitzar-lo i veure si disposa de les característiques adequades per integrar-lo en un robot autònom d’exploració del projecte Sant Bernardo. S’hauran de fer les anàlisis de la precisió del mòdul en les diferents direccions cardinals, es a dir Nord, Sud, Est, Oest i altura i veure la diferència d’error que hi ha en cada una, veure si la precisió varia molt en diferents situacions, com en cel obert, en sotabosc, costat i interior edificis. A més a més s’haurà de mirar la repetibilitat, la diferencia d’error amb diferentnombre de satèl•lits connectats i si disposa de suficient velocitat de processat per a podar corregir la posició del robot en moviment. Un cop analitzades les característiques del mòdul receptor elegit, es decidirà si aquest ésadequat per fer les correccions de posició del robot, o s’haurà d’adquirir un mòdul de característiques superiors i per tant molt més car per a dura a terme adequadament la correcció de la posició

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Mechatronics Research Centre (MRC) owns a small scale robot manipulator called aMini-Mover 5. This robot arm is a microprocessor-controlled, six-jointed mechanical armdesigned to provide an unusual combination of dexterity and low cost.The Mini-Mover-5 is operated by a number of stepper motors and is controlled by a PCparallel port via a discrete logic board. The manipulator also has an impoverished array ofsensors.This project requires that a new control board and suitable software be designed to allow themanipulator to be controlled from a PC. The control board will also provide a mechanism forthe values measured using some sensors to be returned to the PC.On this project I will consider: stepper motor control requirements, sensor technologies,power requirements, USB protocols, USB hardware and software development and controlrequirements (e.g. sample rates).In this report we will have a look at robots history and background, as well as we willconcentrate how stepper motors and parallel port work

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L’estudi que es realitza en aquest projecte/treball final de carrera queda englobat dins del grup de recerca MICE (Modal Intervals Control and Engeneering), el qual realitzainvestigacions entorn al control de glucèmia. Aquest grup de recerca vinculat a la Universitat de Girona col•labora amb l’Hospital Universitari Dr. Josep Trueta de Girona. La temàtica principal tractarà de realitzar el control de glucèmia en pacients crítics, que es troben ingressats en la unitat de cures intensives de qualsevol hospital. Com a conseqüència d’aquesta problemàtica, s’ha implementat en un entorn virtual, un pacient el qual simula la situació d’un pacient real en la unitat de cures intensives. El model emprat per a la obtenció del model de pacient virtual és el desenvolupat per Chase et al. (2005), el qual mitjançant variables com l’alimentació enteral i la sensibilitat insulínica, es podien realitzar assajos reals per a validar protocols de control ‘in silico’ per posteriorment realitzar assajos amb població real

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aquest projecte pretén presentar de forma clara i detallada l’estructura i el funcionament del robot així com dels components que el conformen. Aquesta informació és de vital importància a l’hora de desenvolupar aplicacions per al robot. Un cop descrites les característiques del robot s’analitzaran les eines necessàries i/o disponibles per poder desenvolupar programari per cada nivell de la forma més senzilla i eficient possible. Posteriorment s’analitzaran els diferents nivells de programació i se’n contrastaran els avantatges i els inconvenients de cada un. Aquest anàlisi es començarà fent pel nivell més alt i anirà baixant amb la intenció de no entrar en nivells més baixos del necessari. Baixar un nivell en la programació suposa haver de crear aplicacions sempre compatibles amb els nivells superiors de forma que com més es baixa més augmenta la complexitat. A partir d’aquest anàlisi s’ha arribat a la conclusió que per tal d’aprofitar totes les prestacions del robot és precís arribar a programar en el nivell més baix del robot. Finalment l’objectiu és obtenir una sèrie de programes per cada nivell que permetin controlar el robot i fer-lo seguir senzilles trajectòries

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AMADEUS is a dexterous subsea robot hand incorporating force and slip contact sensing, using fluid filled tentacles for fingers. Hydraulic pressure variations in each of three flexible tubes (bellows) in each finger create a bending moment, and consequent motion or increase in contact force during grasping. Such fingers have inherent passive compliance, no moving parts, and are naturally depth pressure-compensated, making them ideal for reliable use in the deep ocean. In addition to the mechanical design, development of the hand has also considered closed loop finger position and force control, coordinated finger motion for grasping, force and slip sensor development/signal processing, and reactive world modeling/planning for supervisory `blind grasping¿. Initially, the application focus is for marine science tasks, but broader roles in offshore oil and gas, salvage, and military use are foreseen. Phase I of the project is complete, with the construction of a first prototype. Phase I1 is now underway, to deploy the hand from an underwater robot arm, and carry out wet trials with users.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AMADEUS is a dexterous subsea robot hand incorporating force and slip contact sensing, using fluid filled tentacles for fingers. Hydraulic pressure variations in each of three flexible tubes (bellows) in each finger create a bending moment, and consequent motion or increase in contact force during grasping. Such fingers have inherent passive compliance, no moving parts, and are naturally depth pressure-compensated, making them ideal for reliable use in the deep ocean. In addition to the mechanical design, development of the hand has also considered closed loop finger position and force control, coordinated finger motion for grasping, force and slip sensor development/signal processing, and reactive world modeling/planning for supervisory `blind grasping¿. Initially, the application focus is for marine science tasks, but broader roles in offshore oil and gas, salvage, and military use are foreseen. Phase I of the project is complete, with the construction of a first prototype. Phase I1 is now underway, to deploy the hand from an underwater robot arm, and carry out wet trials with users.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Drug development has improved over recent decades, with refinements in analytical techniques, population pharmacokinetic-pharmacodynamic (PK-PD) modelling and simulation, and new biomarkers of efficacy and tolerability. Yet this progress has not yielded improvements in individualization of treatment and monitoring, owing to various obstacles: monitoring is complex and demanding, many monitoring procedures have been instituted without critical assessment of the underlying evidence and rationale, controlled clinical trials are sparse, monitoring procedures are poorly validated and both drug manufacturers and regulatory authorities take insufficient account of the importance of monitoring. Drug concentration and effect data should be increasingly collected, analyzed, aggregated and disseminated in forms suitable for prescribers, along with efficient monitoring tools and evidence-based recommendations regarding their best use. PK-PD observations should be collected for both novel and established critical drugs and applied to observational data, in order to establish whether monitoring would be suitable. Methods for aggregating PK-PD data in systematic reviews should be devised. Observational and intervention studies to evaluate monitoring procedures are needed. Miniaturized monitoring tests for delivery at the point of care should be developed and harnessed to closed-loop regulated drug delivery systems. Intelligent devices would enable unprecedented precision in the application of critical treatments, i.e. those with life-saving efficacy, narrow therapeutic margins and high interpatient variability. Pharmaceutical companies, regulatory agencies and academic clinical pharmacologists share the responsibility of leading such developments, in order to ensure that patients obtain the greatest benefit and suffer the least harm from their medicines.