975 resultados para CIRCADIAN OSCILLATOR


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação para a Ciência e a Tecnologia (FCT) - PhD grant (SFRH/BD/62568/2009)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Modern CMOS radio frequency (RF) Receivers have enabled efficient and increasing applications. The main requirement is to have system in a single chip, in order to minimize area and cost. For the purpose it is required the development of inductorless circuits for the key blocks of an RF receiver. Examples of this key blocks are RC oscillators, RF band pass filters, and Low Noise Amplifiers. The present dissertation presents an inductorless wideband MOSFET-only RF Non-Gyrator Type of Active Inductors with low area, low cost, and very low power, capable of covering the whole WMTS, and ISM, band and intended for biomedical applications. The proposed circuit is based on a floating capacitor connected between two controlled current sources. The first current source, which is controlled by the circuit input voltage, has two objectives: supply current to the capacitor (

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The work described in this thesis was performed at the Laboratory for Intense Lasers (L2I) of Instituto Superior Técnico, University of Lisbon (IST-UL). Its main contribution consists in the feasibility study of the broadband dispersive stages for an optical parametric chirped pulse amplifier based on the nonlinear crystal yttrium calcium oxi-borate (YCOB). In particular, the main goal of this work consisted in the characterization and implementation of the several optical devices involved in pulse expansion and compression of the amplified pulses to durations of the order of a few optical cycles (20 fs). This type of laser systems find application in fields such as medicine, telecommunications and machining, which require high energy, ultrashort (sub-100 fs) pulses. The main challenges consisted in the preliminary study of the performance of the broadband amplifier, which is essential for successfully handling pulses with bandwidths exceeding 100 nm when amplified from the μJ to 20 mJ per pulse. In general, the control, manipulation and characterization of optical phenomena on the scale of a few tens of fs and powers that can reach the PW level are extremely difficult and challenging due to the complexity of the phenomena of radiation-matter interaction and their nonlinearities, observed at this time scale and power level. For this purpose the main dispersive components were characterized in detail, specifically addressing the demonstration of pulse expansion and compression. The tested bandwidths are narrower than the final ones, in order to confirm the parameters of these elements and predict the performance for the broadband pulses. The work performed led to additional tasks such as a detailed characterization of laser oscillator seeding the laser chain and the detection and cancelling of additional sources of dispersion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Quadrature oscillators are key elements in modern radio frequency (RF) transceivers and very useful nowadays in wireless communications, since they can provide: low quadrature error, low phase-noise, and wide tuning range (useful to cover several bands). RC oscillators can be fully integrated without the need of external components (external high Q-inductors), optimizing area, cost, and power consumption. The conventional structure of ring oscillator offers poor frequency stability and phasenoise, low quality factor (Q), and besides being vulnerable to process, voltage and temperature (PVT) variations, its performance degrades as the frequency of operation increases. This thesis is devoted to quadrature oscillators and presents a detailed comparative study of ring oscillator and shift register (SR) approaches. It is shown that in SRs both phase-noise and phase error are reduced, while ring oscillators have the advantage of occupying less area and less consumption due to the reduced number of components in the circuit. Thus, although ring oscillators are more suitable for biomedical applications, SRs are more appropriate for wireless applications, especially when specification requirements are more stringent and demanding. The first architecture studied consists in a simple CMOS ring oscillator employing an odd number of static single-ended inverters as delay cells. Subsequently, the quadrature 4-stage ring oscillator concept is shown and post-layout simulations are presented. The 3 and 4-phase single-frequency local oscillator (LO) generators employing SRs are presented, the latter with 50% and 25% duty-cycles. The circuits operate at 600 MHz and 900 MHz, and were designed in a 130 nm standard CMOS technology with a voltage supply of 1.2 V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Modern telecommunication equipment requires components that operate in many different frequency bands and support multiple communication standards, to cope with the growing demand for higher data rate. Also, a growing number of standards are adopting the use of spectrum efficient digital modulations, such as quadrature amplitude modulation (QAM) and orthogonal frequency division multiplexing (OFDM). These modulation schemes require accurate quadrature oscillators, which makes the quadrature oscillator a key block in modern radio frequency (RF) transceivers. The wide tuning range characteristics of inductorless quadrature oscillators make them natural candidates, despite their higher phase noise, in comparison with LC-oscillators. This thesis presents a detailed study of inductorless sinusoidal quadrature oscillators. Three quadrature oscillators are investigated: the active coupling RC-oscillator, the novel capacitive coupling RCoscillator, and the two-integrator oscillator. The thesis includes a detailed analysis of the Van der Pol oscillator (VDPO). This is used as a base model oscillator for the analysis of the coupled oscillators. Hence, the three oscillators are approximated by the VDPO. From the nonlinear Van der Pol equations, the oscillators’ key parameters are obtained. It is analysed first the case without component mismatches and then the case with mismatches. The research is focused on determining the impact of the components’ mismatches on the oscillator key parameters: frequency, amplitude-, and quadrature-errors. Furthermore, the minimization of the errors by adjusting the circuit parameters is addressed. A novel quadrature RC-oscillator using capacitive coupling is proposed. The advantages of using the capacitive coupling are that it is noiseless, requires a small area, and has low power dissipation. The equations of the oscillation amplitude, frequency, quadrature-error, and amplitude mismatch are derived. The theoretical results are confirmed by simulation and by measurement of two prototypes fabricated in 130 nm standard complementary metal-oxide-semiconductor (CMOS) technology. The measurements reveal that the power increase due to the coupling is marginal, leading to a figure-of-merit of -154.8 dBc/Hz. These results are consistent with the noiseless feature of this coupling and are comparable to those of the best state-of-the-art RC-oscillators, in the GHz range, but with the lowest power consumption (about 9 mW). The results for the three oscillators show that the amplitude- and the quadrature-errors are proportional to the component mismatches and inversely proportional to the coupling strength. Thus, increasing the coupling strength decreases both the amplitude- and quadrature-errors. With proper coupling strength, a quadrature error below 1° and amplitude imbalance below 1% are obtained. Furthermore, the simulations show that increasing the coupling strength reduces the phase noise. Hence, there is no trade-off between phase noise and quadrature error. In the twointegrator oscillator study, it was found that the quadrature error can be eliminated by adjusting the transconductances to compensate the capacitance mismatch. However, to obtain outputs in perfect quadrature one must allow some amplitude error.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de Doutoramento em Ciências da Saúde

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When interacting with each other, people often synchronize spontaneously their movements, e.g. during pendulum swinging, chair rocking[5], walking [4][7], and when executing periodic forearm movements[3].Although the spatiotemporal information that establishes the coupling, leading to synchronization, might be provided by several perceptual systems, the systematic study of different sensory modalities contribution is widely neglected. Considering a) differences in the sensory dominance on the spatial and temporal dimension[5] , b) different cue combination and integration strategies [1][2], and c) that sensory information might provide different aspects of the same event, synchronization should be moderated by the type of sensory modality. Here, 9 naïve participants placed a bottle periodically between two target zones, 40 times, in 12 conditions while sitting in front of a confederate executing the same task. The participant could a) see and hear, b) see , c) hear the confederate, d) or audiovisual information about the movements of the confederate was absent. The couple started in 3 different relative positions (i.e., in-phase, anti-phase, out of phase). A retro-reflective marker was attached to the top of the bottles. Bottle displacement was captured by a motion capture system. We analyzed the variability of the continuous relative phase reflecting the degree of synchronization. Results indicate the emergence of spontaneous synchronization, an increase with bimodal information, and an influence of the initial phase relation on the particular synchronization pattern. Results have theoretical implication for studying cue combination in interpersonal coordination and are consistent with coupled oscillator models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Long-term exposure to transmeridian flights has been shown to impact cognitive functioning. Nevertheless, the immediate effects of jet lag in the activation of specific brain networks have not been investigated. We analyzed the impact of short-term jet lag on the activation of the default mode network (DMN). A group of individuals who were on a transmeridian flight and a control group went through a functional magnetic resonance imaging acquisition. Statistical analysis was performed to test for differences in the DMN activation between groups. Participants from the jet lag group presented decreased activation in the anterior nodes of the DMN, specifically in bilateral medial prefrontal and anterior cingulate cortex. No areas of increased activation were observed for the jet lag group. These results may be suggestive of a negative impact of jet lag on important cognitive functions such as introspection, emotional regulation and decision making in a few days after individuals arrive at their destination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de Doutoramento em Ciências da Saúde

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the influences of circadian variations on tilt-table testing (TTT) results by comparing the positivity rate of the test performed during the morning with that of the test performed in the afternoon and to evaluate the reproducibility of the results in different periods of the day. METHODS: One hundred twenty-three patients with recurrent unexplained syncope or near-syncope referred for TTT were randomized into 2 groups. In group I, 68 patients, TTT was performed first in the afternoon and then in the morning. In group II, 55 patients, the test was performed first in the morning and then in the afternoon. RESULTS: The TTT protocol was the prolonged passive test, without drug sensitization. Twenty-nine (23.5%) patients had a positive result in at least one of the periods. The positivity rate for each period was similar: 20 (16.2%) patients in the afternoon and 19 (15.4%) in the morning (p=1.000). Total reproducibility (positive/positive and negative/negative) was observed in 49 (89%) patients in group I and in 55 (81%) in group II. Reproducibility of the results was obtained in 94 (90.4%) patients with first negative tests but in 10 (34%) patients with first positive tests. CONCLUSION: TTT could be performed during any period of the day, and even in the 2 periods to enhance positivity. Considering the low reproducibility rate of the positive tests, serial TTT to evaluate therapeutic efficacy should be performed during the same period of the day.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente estudo teve por objetivo analisar os possíveis efeitos do trabalho por turnos, incluindo o turno noturno, a nível da saúde, vida familiar e social, numa empresa do sector da indústria. Foi construído um questionário que abordava questões relativas aos dados sociodemográficos, organização temporal do trabalho, qualidade do sono, exigências da tarefa e envolvimento, saúde, vida familiar e social, e posteriormente foi aplicado a uma amostra de 24 trabalhadores com idades entre os 29 e os 52 anos (41,58±5,79 anos). Os resultados mostram uma tendência para doenças como a obesidade, colesterol elevado e manifestação de sintomas relacionados com problemas digestivos nos trabalhadores que trabalham por turnos à [sic] mais anos. Antes do primeiro turno noturno o tempo de sono é bastante reduzido e fica aquém do tempo que os trabalhadores sentem que necessitam dormir para se sentirem bem. O turno da tarde é o que permite os trabalhadores ficarem com um tempo de sono mais próximo desse “ideal”. Em relação à idade, todos os trabalhadores do grupo etário mais velho manifestam interrupções do sono diurno. Também se verifica um maior descontentamento destes trabalhadores com o tempo livre para realizar atividades que tragam bem-estar. Este estudo contribui para o conhecimento da realidade do trabalho por turnos na indústria e espera-se que desperte a procura de soluções que otimizem a vida destes trabalhadores.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pyrogallol, uncatalyzed bromate oscillator, electric field, pulse wave, Belousov-Zhabotinsky reaction, reversal

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The diet of the benthic-feeding fish Iheringichthys labrosus (Lütken, 1874) was analyzed. Samples were taken bimonthly from December 1999 to January 2002, in three sites of the Ibicuí River, a tributary of Uruguay River basin (Rio Grande do Sul, Brazil). In each sampling point the specimens were collected in lentic and lotic environments. Gillnets and trammel nets were examined every 6 hours (6h, 12h, 18h and 24h). Diet description was based on the frequency of occurrence and the volume of each food item to obtain the Alimentary Index (IAi). The average stomach fullness was adopted to detect variations in the feeding activity according to the season, the circadian rhythm and the environment. Chironomids were the most important food item, followed by mollusks, and feeding activity was highest in summer, during daylight (6h and 12h), and in the lotic environment of the second sampling point.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to identify the patterns of seasonal and diel variation and the most important abiotic factors that influence variation in the fish assemblage of the Delta of the Jacuí River in southern Brazil. Seventy-two samples were collected over a one year period. Water temperature was the abiotic factor with the greatest influence on the distribution of the assemblage. The structure of the assemblage exhibited significant changes in terms of species abundance and biomass during the year, with the greatest abundance and biomass being observed during the autumn. There was no significant difference between day and night in terms of abundance, but biomass was significantly greater during the night than during the day.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Blood pressure follows a circadian rhythm with a physiologic 10% to 20% decrease during the night. There is now increasing evidence that a blunted decrease or an increase in nighttime blood pressure is associated with a greater prevalence of target organ damage and a faster disease progression in patients with chronic kidney diseases. Several factors contribute to the changes in nighttime blood pressure including changes in hormonal profiles such as variations in the activity of the renin-angiotensin and the sympathetic nervous systems. Recently, it was hypothesized that the absence of a blood pressure decrease during the nighttime (nondipping) is in fact a pressure-natriuresis mechanism enabling subjects with an impaired capacity to excrete sodium to remain in sodium balance. In this article, we review the clinical and epidemiologic data that tend to support this hypothesis. Moreover, we show that most, if not all, clinical conditions associated with an impaired dipping profile are diseases associated either with a low glomerular filtration rate and/or an impaired ability to excrete sodium. These observations would suggest that renal function, and most importantly the ability to eliminate sodium during the day, is indeed a key determinant of the circadian rhythm of blood pressure.