910 resultados para Automated quantification


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our objective was to determine if automated peritoneal dialysis (APD) leads to changes in nutritional parameters of patients treated by continuous ambulatory peritoneal dialysis (CAPD). Twenty-six patients (15 males; 50.5 ± 14.3 years) were evaluated during CAPD while training for APD and after 3 and 6 months of APD. Body fat was assessed by the sum of skinfold thickness and the other body compartments were assessed by bioelectrical impedance. During the 6-month follow-up, 12 patients gained more than 1 kg (GW group), 8 patients lost more than 1 kg (LW group), and 6 patients maintained body weight (MW group). Except for length on dialysis that was longer for the LW group compared with the GW group, no other differences were found between the groups at baseline. After 6 months on APD, the LW group had a reduction in body fat (24.5 ± 7.7 vs 22.1 ± 7.3 kg; P = 0.01), body cell mass (22.6 ± 6.2 vs 21.6 ± 5.8 kg, P = 0.02) and phase angle (5.4 ± 0.9 vs 5.1 ± 0.8 degrees, P = 0.004). In the GW group, body fat (25 ± 7.6 vs 27.2 ± 7.6 kg, P = 0.001) and body cell mass (20.1 ± 3.9 vs 20.8 ± 4.0 kg, P = 0.05) were increased. In the present study, different patterns of change in body composition were found. The length of previous dialysis treatment seems to be the most important factor in determining these nutritional modifications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In vivo proton magnetic resonance spectroscopy (¹H-MRS) is a technique capable of assessing biochemical content and pathways in normal and pathological tissue. In the brain, ¹H-MRS complements the information given by magnetic resonance images. The main goal of the present study was to assess the accuracy of ¹H-MRS for the classification of brain tumors in a pilot study comparing results obtained by manual and semi-automatic quantification of metabolites. In vivo single-voxel ¹H-MRS was performed in 24 control subjects and 26 patients with brain neoplasms that included meningiomas, high-grade neuroglial tumors and pilocytic astrocytomas. Seven metabolite groups (lactate, lipids, N-acetyl-aspartate, glutamate and glutamine group, total creatine, total choline, myo-inositol) were evaluated in all spectra by two methods: a manual one consisting of integration of manually defined peak areas, and the advanced method for accurate, robust and efficient spectral fitting (AMARES), a semi-automatic quantification method implemented in the jMRUI software. Statistical methods included discriminant analysis and the leave-one-out cross-validation method. Both manual and semi-automatic analyses detected differences in metabolite content between tumor groups and controls (P < 0.005). The classification accuracy obtained with the manual method was 75% for high-grade neuroglial tumors, 55% for meningiomas and 56% for pilocytic astrocytomas, while for the semi-automatic method it was 78, 70, and 98%, respectively. Both methods classified all control subjects correctly. The study demonstrated that ¹H-MRS accurately differentiated normal from tumoral brain tissue and confirmed the superiority of the semi-automatic quantification method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for determining aflatoxins B1 (AFB1), B2 (AFB2),G1 (AFG1) andG2 (AFG2) in maize with florisil clean up was optimised aiming at one-dimensional thin layer chromatography (TLC) analysis with visual and densitometric quantification. Aflatoxins were extracted with chloroform: water (30:1, v/v), purified through florisil cartridges, separated on TLC plate, detected and quantified by visual and densitometric analysis. The in-house method performance characteristics were determined by using spiked, naturally contaminated maize samples, and certified reference material. The mean recoveries for aflatoxins were 94.2, 81.9, 93.5 and 97.3% in the range of 1.0 to 242 µg/kg for AFB1, 0.3 to 85mg/kg for AFB2, 0.6 to 148mg/kg for AFG1 and 0.6 to 140mg/kg for AFG2, respectively. The correlation values between visual and densitometric analysis for spiked samples were higher than 0.99 for AFB1, AFB2, AFG1 and 0.98 for AFG2. The mean relative standard deviations (RSD) for spiked samples were 16.2, 20.6, 12.8 and 16.9% for AFB1, AFB2, AFG1 and AFG2, respectively. The RSD of the method for naturally contaminated sample (n = 5) was 16.8% for AFB1 and 27.2% for AFB2. The limits of detection of the method (LD) were 0.2, 0.1, 0.1 and 0.1mg/kg and the limits of quantification (LQ) were 1.0, 0.3, 0.6 and 0.6mg/kg for AFB1, AFB2, AFG1 and AFG2, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tutkimuksen tavoitteena oli selvittää automaattisten tilausjärjestelmien onnistuneen käyttöönottoon taustalla vaikuttavia tekijöitä vähittäiskaupan toimialalla ja etsiä ratkaisua kyseisten järjestelmien onnistuneeseen käyttöönottoon tässä ympäristössä. Tutkimus analysoi yli sadan kaupan järjestelmän käyttöönottoa ja käyttöönoton tuloksia. Tutkimusta varten haastateltiin niin yhtiön sisältä kuin ulkopuoleltakin mukana olleita hankintajärjestelmän ja jalkautuksen asiantuntijoita. Tämän lisäksi järjestelmän käyttöönottaneisiin kauppoihin lähetettiin kyselyt, joita analysoitiin ryhmissä automaattisen tilausjärjestelmän tietojen pohjalta. Työn tuloksena pystyttiin tunnistamaan tietty joukko taustatekijöitä, jotka tulee ottaa käyttöönotossa huomioon sekä saatuihin tutkimustuloksiin perustuen kehitettiin malli vastaavanlaisten järjestelmien käyttöönotolle vähittäiskaupan alalle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research is looking to find out what benefits employees expect the organization of data governance gains for an organization and how it benefits implementing automated marketing capabilities. Quality and usability of the data are crucial for organizations to meet various business needs. Organizations have more data and technology available what can be utilized for example in automated marketing. Data governance addresses the organization of decision rights and accountabilities for the management of an organization’s data assets. With automated marketing it is meant sending a right message, to a right person, at a right time, automatically. The research is a single case study conducted in Finnish ICT-company. The case company was starting to organize data governance and implementing automated marketing capabilities at the time of the research. Empirical material is interviews of the employees of the case company. Content analysis is used to interpret the interviews in order to find the answers to the research questions. Theoretical framework of the research is derived from the morphology of data governance. Findings of the research indicate that the employees expect the organization of data governance among others to improve customer experience, to improve sales, to provide abilities to identify individual customer’s life-situation, ensure that the handling of the data is according to the regulations and improve operational efficiency. The organization of data governance is expected to solve problems in customer data quality that are currently hindering implementation of automated marketing capabilities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increasing presence of products derived from genetically modified (GM) plants in human and animal diets has led to the development of detection methods to distinguish biotechnology-derived foods from conventional ones. The conventional and real-time PCR have been used, respectively, to detect and quantify GM residues in highly processed foods. DNA extraction is a critical step during the analysis process. Some factors such as DNA degradation, matrix effects, and the presence of PCR inhibitors imply that a detection or quantification limit, established for a given method, is restricted to a matrix used during validation and cannot be projected to any other matrix outside the scope of the method. In Brazil, sausage samples were the main class of processed products in which Roundup Ready® (RR) soybean residues were detected. Thus, the validation of methodologies for the detection and quantification of those residues is absolutely necessary. Sausage samples were submitted to two different methods of DNA extraction: modified Wizard and the CTAB method. The yield and quality were compared for both methods. DNA samples were analyzed by conventional and real-time PCR for the detection and quantification of Roundup Ready® soybean in the samples. At least 200 ng of total sausage DNA was necessary for a reliable quantification. Reactions containing DNA amounts below this value led to large variations on the expected GM percentage value. In conventional PCR, the detection limit varied from 1.0 to 500 ng, depending on the GM soybean content in the sample. The precision, performance, and linearity were relatively high indicating that the method used for analysis was satisfactory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and low cost method to determine volatile contaminants in post-consumer recycled PET flakes was developed and validated by Headspace Dynamic Concentration and Gas Chromatography-Flame Ionization Detection (HDC-GC-FID). The analytical parameters evaluated by using surrogates include: correlation coefficient, detection limit, quantification limit, accuracy, intra-assay precision, and inter-assay precision. In order to compare the efficiency of the proposed method to recognized automated techniques, post-consumer PET packaging samples collected in Brazil were used. GC-MS was used to confirm the identity of the substances identified in the PET packaging. Some of the identified contaminants were estimated in the post-consumer material at concentrations higher than 220 ng.g-1. The findings in this work corroborate data available in the scientific literature pointing out the suitability of the proposed analytical method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to analyze the fatty acid and proximate composition of five brands of breaded chicken steak (A, B, C, D, and E) by accurate chromatographic quantification and to compare the experimental results with food label nutrition facts. The protein values of all brands were in agreement with the Brazilian regulation values, except for that of sample E, which presented the highest lipid content. Thirteen fatty acids were identified in the studied brands and the major ones were oleic acid, linoleic acid, and palmitic acid. The polyunsaturated fatty acid/saturated fatty acid ratios were within the values considered appropriate for human health; however, the high n-6/n-3 ratios found can result in an unbalanced intake of these fat acids. Only samples D and E can be considered trans free according to the regulations. The comparison of the analyses' results and the food label nutrition facts showed little variation in protein values. Nevertheless, most brands underestimated their lipid and energy levels. Brand B and C labels declared "free of trans", but the obteined results showed levels excedding those especified by regulation to be considered trans free values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pisciculture is an economic activity that is steadily growing in the state of Parana, Brazil, and Nile tilapia (Oreochromis niloticus) is one of the widely cultivated species in this state. Tilapia is not only a very nutritious food, but also an important indicator of environmental contamination. This study aimed to verify contamination by cadmium, copper and lead in tilapia fillets, and to compare the found values to international legislations. Were collected 135 samples of tilapia fillets, between July 2006 and May 2007, in three fish stores located in regions west and north of Paraná State. Samples of tilapia fillet were analyzed in relation to the presence of cadmiun, lead and copper, using atomic absorption spectrophotometry. Lead has not been detected in the analyses. Cadmium has been detected in three samples, on concentrations of 0.012 µg.g-1, 0.011 µg.g-1 and 0.014 µg.g-1. Copper has been detected in all fillets, and the average concentration of each cold storage plant was of 0.122 µg.g-1, 0.106 µg.g-1 and 0.153 µg.g-1. The concentrations found in this study are within the limits allowed by both the European and the Australian legislations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to characterize the centesimal composition and quantify fatty acids in regular and diet chocolate brands with emphasis on trans fatty acids. Regular and diet dark chocolate samples from the major brands analyzed were purchased from different local supermarkets in the city of Maringá. The brands were labeled with letters and five lots of each brand with three chocolate units per lot were analyzed in triplicate. We observed that the diet chocolates from the same brands presented larger lipid contents. The main fatty acids observed were saturated fatty acids (SFA), myristic acid (14:0), palmitic acid (16:0), and estearic acid (18:0). Among the monounsaturated fatty acids (MUFA), polyunsaturated fatty acids (PUFA) and trans fatty acids, oleic acid (18:1n-9), linoleic acid (18:2n-6), and elaidic acid (18:1-9t) predominated. The trans fatty acid contents found in the analyzed samples were lower than and/or in accordance with the limits proposed by the Brazilian regulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to quantify the levels of catechins and caffeine in various forms of presentation of green tea: infusion tea bags, extract, and ready-to-drink beverage and, based on their content, identify the most suitable for consumption. High Performance Liquid Chromatography (HPLC) analytical method was used for the quantification of catechins and caffeine. The tea bags had the highest concentration of total catechins with 5 to 9.5% followed by the extract with 3.64 to 4.88%, and ready-to-drink green tea beverage showed low levels of catechins, from 0.14 to 0.26%. As for caffeine content, green tea extract had higher concentration (1.96 to 3.54%) compared to the tea bags (1.39 to 1.57%). Tea bags were found the most suitable for consumption because it contains higher amounts of catechins and smaller amounts of caffeine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method using Liquid Chromatography Tanden Mass Spectrometry (LC-MS/MS) with matrix-matched calibration curve was developed and validated for determining ochratoxin A (OTA) in green coffee. Linearity was found between 3.0 and 23.0 ng.g-1. Mean recoveries ranged between 90.45% and 108.81%; the relative standard deviation under repeatability and intermediate precision conditions ranged from 5.39% to 9.94% and from 2.20% to 14.34%, respectively. The limits of detection and quantification were 1.2 ng.g-1 and 3.0 ng.g-¹, respectively. The method developed was suitable and contributed to the field of mycotoxin analysis, and it will be used for future production of the Certified Reference Material (CRM) for OTA in coffee.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract The growing interest in the usage of dietary fiber in food has caused the need to provide precise tools for describing its physical properties. This research examined two dietary fibers from oats and beets, respectively, in variable particle sizes. The application of automated static image analysis for describing the hydration properties and particle size distribution of dietary fiber was analyzed. Conventional tests for water holding capacity (WHC) were conducted. The particles were measured at two points: dry and after water soaking. The most significant water holding capacity (7.00 g water/g solid) was achieved by the smaller sized oat fiber. Conversely, the water holding capacity was highest (4.20 g water/g solid) in larger sized beet fiber. There was evidence for water absorption increasing with a decrease in particle size in regards to the same fiber source. Very strong correlations were drawn between particle shape parameters, such as fiber length, straightness, width and hydration properties measured conventionally. The regression analysis provided the opportunity to estimate whether the automated static image analysis method could be an efficient tool in describing the hydration properties of dietary fiber. The application of the method was validated using mathematical model which was verified in comparison to conventional WHC measurement results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Sugarcane monosaccharides are reducing sugars, and classical analytical methodologies (Lane-Eynon, Benedict, complexometric-EDTA, Luff-Schoorl, Musson-Walker, Somogyi-Nelson) are based on reducing copper ions in alkaline solutions. In Brazil, certain factories use Lane-Eynon, others use the equipment referred to as “REDUTEC”, and additional factories analyze reducing sugars based on a mathematic model. The objective of this paper is to understand the relationship between variations in millivolts, mass and tenors of reducing sugars during the analysis process. Another objective is to generate an automatic model for this process. The work herein uses the equipment referred to as “REDUTEC”, a digital balance, a peristaltic pump, a digital camcorder, math programs and graphics programs. We conclude that the millivolts, mass and tenors of reducing sugars exhibit a good mathematical correlation, and the mathematical model generated was benchmarked to low-concentration reducing sugars (<0.3%). Using the model created herein, reducing sugars analyses can be automated using the new equipment.