879 resultados para Attitude alignment
Resumo:
Computer navigation in total knee arthroplasty is somewhat controversial. We have previously shown that femoral component positioning is more accurate with computed navigation than with conventional implantation techniques, but the clinical impact of this is unknown. We now report the 5-year outcome of our previously reported 2-year outcome study.
Resumo:
This study examined the influence of single peer to peer interventions on participants' recovery attitudes.
High accuracy alignment facility for the receiver and transmitter of the BepiColombo Laser Altimeter
Resumo:
The accurate co-alignment of the transmitter to the receiver of the BepiColombo Laser Altimeter is a challenging task for which an original alignment concept had to be developed. We present here the design, construction and testing of a large collimator facility built to fulfill the tight alignment requirements. We describe in detail the solution found to attenuate the high energy of the instrument laser transmitter by an original beam splitting pentaprism group. We list the different steps of the calibration of the alignment facility and estimate the errors made at each of these steps. We finally prove that the current facility is ready for the alignment of the flight instrument. Its angular accuracy is 23 μrad.
Resumo:
An Internet survey demonstrated the existence of problems related to intraoperative tracking camera set-up and alignment. It is hypothesized that these problems are a result of the limited field of view of today's optoelectronic camera systems, which is usually insufficiently large to keep the entire site of surgical action in view during an intervention. A method is proposed to augment a camera's field of view by actively controlling camera orientation, enabling it to track instruments as they are used intraoperatively. In an experimental study, an increase of almost 300% was found in the effective volume in which instruments could be tracked.
Resumo:
This paper addresses the problem of estimating postoperative cup alignment from single standard X-ray radiograph with gonadal shielding. The widely used procedure of evaluation of cup orientation following total hip arthroplasty using single standard anteroposterior radiograph is known inaccurate, largely due to the wide variability in individual pelvic position relative to X-ray plate. 2D-3D image registration methods have been introduced to estimate the rigid transformation between a preoperative CT volume and postoperative radiograph(s) for an accurate estimation of the postoperative cup alignment relative to an anatomical reference extracted from the CT data. However, these methods require either multiple radiographs or a radiograph-specific calibration, both of which are not avaiable for most retrospective studies. Furthermore, these methods were only evaluated on X-ray radiograph(s) without gonadal shielding. In this paper, we propose to use a hybrid 2D-3D registration scheme combining an iterative landmark-to-ray registration with a 2D-3D intensity-based registration to estimate the rigid transfromation for a precise estimation of cup alignment. Quantitative and qualitative results evaluated on clinical and cadaveric datasets are given which indicate the validity of our approach.
Resumo:
AIM: Establish a list of first year medical students' attitudes, doubts, and knowledge in the fields of organ transplantation and donation. METHOD: Anonymized questionnaire handed out to students during class lectures. RESULTS: 183 questionnaires were distributed and 117 returned (participation: 64%). The average age of the students was 21.6 +/- 2.7 years (range 18 to 38 years); the sample included 71 women (60.7%) and 48 men (39.3%). Only 2 students (2%) were not interested in the subject of organ donation. The students knew very little of the legal aspects of organ donation and 1/4 of them thought there was even a Federal law regarding organ transplantation. When asked if they knew whether a law existed in the Canton of Berne, 44% replied yes, but only 24 (20%) knew that this is contradictory. There was no gender difference in the answers to these question. From 57 students (48%) 246 individual comments on doubts and concerns were analyzed. In this respect, the students mainly questioned whether the donor was truly dead when donation took place (n = 48), if illegal transplantation could be eliminated (n = 44) and if transplantation was truly necessary (n = 43). Some also mentioned religious/ethical doubts (n = 42). In regard to organ donation by a living individual, 27 students were concerned about the health of this donor. 20 students had doubts regarding the pressure possibly applied by family members and friends and as many voiced doubts in regard to premature diagnosis of brain death of potential donors. Only 2 students were concerned about the post-mortem presentation. 45 students (48%) indicated discomfort with the donation of certain organs. They ranked the kidney as the first organ to donate, followed by the pancreas, heart, cornea, intestine, lung and liver. CONCLUSION: The interest in organ donation and transplantation is already strong in fist year medical students in the pre-clinical stage. However, differences from lay public are not readably detectable at this stage of medical training. Adequate information could influence future physicians in their mediatory role.
Resumo:
This report presents a study on the problem of spacecraft attitude control using magnetic actuators. Several existing approaches are reviewed and one control strategy is implemented and simulated. A time-varying feedback control law achieving inertial pointing for magnetically actuated spacecraft is implemented. The report explains the modeling of the spacecraft rigid body dynamics, kinematics and attitude control in detail. Besides the fact that control laws have been established for stabilization around local equilibrium, this report presents the results of a control law that yields a generic, global solution for attitude stabilization of a magnetically actuated spacecraft. The report also involves the use MATLAB as a tool for both modeling and simulation of the spacecraft and controller. In conclusion, the simulation outlines the performance of the controller in independently stabilizing the spacecraft in three mutually perpendicular directions.