997 resultados para Aharonov-Bohm-like interferometer
Resumo:
A parallel plate interferometer with a reflecting mirror for measuring angular displacement is proposed. A deflection angle of a beam caused by an angular displacement is amplified by use of a reflecting mirror to increase the optical path difference (OPD) in the plane-parallel plate, which provides high sensitivity of the phase measurement. Detection of light transmitted through the plane-parallel plate with a position sensitive detector (PSD) enables high accurate measurement of the initial angle of incidence to the plane-parallel plate with insensitivity to stray light. The improved parallel plate interferometer achieves a measurement repeatability of 10(-8) rad. (C) 2007 The Optical Society of Japan.
Resumo:
Topography of a granite surface has an effect on the vertical positioning of a wafer stage in a lithographic tool, when the wafer stage moves on the granite. The inaccurate measurement of the topography results in a bad leveling and focusing performance. In this paper, an in situ method to measure the topography of a granite surface with high accuracy is present. In this method, a high-order polynomial is set up to express the topography of the granite surface. Two double-frequency laser interferometers are used to measure the tilts of the wafer stage in the X- and Y-directions. From the sampling tilts information, the coefficients of the high-order polynomial can be obtained by a special algorithm. Experiment results shows that the measurement reproducibility of the method is better than 10 nm. (c) 2006 Elsevier GmbH. All rights reserved.
Resumo:
The measurement accuracy of a parallel-plate interferometer for angular displacement measurement is analyzed. The measurement accuracy of angular displacement is not only related to the accuracy of phase extraction, but also related to initial incident angle, refraction index and thickness of plane-parallel plate as well as wavelength's stability of laser diode, etc. Theoretical analysis and computer simulation show that the measurement error of the angular displacement bears a minimum value when choosing an optimal initial incident angle in a large range. These analytical results serve as a guide in practical measurement. In this interferometer, reducing the refraction index or increasing the thickness of the parallel plate can improve the measurement accuracy; and the relative error of the phase measurement is 3.0 x 10(-4) corresponding to 1 degrees C temperature variation. Based on these theoretical and experimental results, the measurement accuracy of the parallel-plate interferometer is up to an order of 10(-8) rad. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
In the process of interferometric testing, the measurement result is influenced by the system structure, which reduces the measurement accuracy. To obtain an accurate test result, it is necessary to analyze the test system, and build the relationship between the measurement error and the system parameters. In this paper, the influences of the system elements which include the collimated lens and the standard surface on the interferometric testing are analyzed, the expressions of phase distribution and wavefront error on the detector are obtained, the method to remove some element errors is introduced, and the optimization structure relationships are given. (C) 2006 Elsevier GmbH. All rights reserved.
Resumo:
A new dual-frequency laser displacement measurement interferometer with nanometer precision has been developed. An eight-pass optical subdivision technology is proposed to improve resolution based on commercial interferometers. A static positioning error measuring method has been used to examine the precision and repeatability of the laser interferometer. An optical resolution of 1.24 nm and an accuracy of nanometer scale have been achieved.
Resumo:
Only the first- order Doppler frequency shift is considered in current laser dual- frequency interferometers; however; the second- order Doppler frequency shift should be considered when the measurement corner cube ( MCC) moves at high velocity or variable velocity because it can cause considerable error. The influence of the second- order Doppler frequency shift on interferometer error is studied in this paper, and a model of the second- order Doppler error is put forward. Moreover, the model has been simulated with both high velocity and variable velocity motion. The simulated results show that the second- order Doppler error is proportional to the velocity of the MCC when it moves with uniform motion and the measured displacement is certain. When the MCC moves with variable motion, the second- order Doppler error concerns not only velocity but also acceleration. When muzzle velocity is zero the second- order Doppler error caused by an acceleration of 0.6g can be up to 2.5 nm in 0.4 s, which is not negligible in nanometric measurement. Moreover, when the muzzle velocity is nonzero, the accelerated motion may result in a greater error and decelerated motion may result in a smaller error.
Resumo:
The theory of optical subdivision techniques of dual-frequency laser interferometers is stated. And a novel optical subdivision technique is proposed originally to enhance resolution of a commercial interferometer by adding some corner-cubes. Then the performance of the interferometer is tested. The interferometer resolution of 1.24 nm and the average error of below 2 nm are achieved by using the technique. The most novel of the optical subdivision technique is without lambda/4 plates. It is less sensitive to environmental changes, it has prodigious potential to improve resolution farther and it can reduce polarization mixing error. (C) 2007 Elsevier GmbH. All rights reserved.