997 resultados para 1995_04041049 TM-78 4502620
Resumo:
Boletim elaborado pela Assessoria de Comunicação e Imprensa da Reitoria da UNESP
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The Restinga of Marambaia is an emerged sand bar located between the Sepetiba Bay and the South Atlantic Ocean, on the south-east coast of Brazil. The objective of this study was to observe the geomorphologic evolution of the coastal zone of the Restinga of Marambaia using multitemporal satellite images acquired by multisensors from 1975 to 2004. The images were digitally segmented by a region growth algorithm and submitted to an unsupervised classification procedure (ISOSEG) followed by a raster edit based on visual interpretation. The image time-series showed a general trend of decrease in the total sand bar area with values varying from 80.61km(2) in 1975 to 78.15km(2) in 2004. The total area calculation based on the 1975 and 1978 Landsat MSS data was shown to be super-estimated in relation to the Landsat TM, Landsat ETM+, and CBERS-2 CCD data. These differences can also be associated to the relatively poorer spatial resolution of the MSS data, nominally 79m, against the 20m of the CCD data and 30m of the TM and ETM+ data. For the estimates of the width in the central portion of the sand bar the variation was from 158m (1975) to 100m (2004). The formation of a spit in the northern region of the study area was visually observed. The area of the spit was estimated, with values varying from 0.82km(2) (1975) to 0.55km(2) (2004).
Resumo:
Objective: We investigated the relation between duration of dual antiplatelet therapy (DAPT) and clinical outcomes up to 12 months after Genous (TM) endothelial progenitor cell capturing R stent (TM) placement in patients from the e-HEALING registry. Background: Cessation of (DAPT) has been shown to be associated with the occurrence of stent thrombosis (ST). After Genous placement, 1 month of DAPT is recommended. Methods: Patients were analyzed according to continuation or discontinuation of DAPT at a 30-day and 6-month landmark, excluding patients with events before the landmark. Each landmark was a new baseline, and outcomes were followed up to 12 months after stenting. The main outcome for our current analysis was target vessel failure (TVF), defined as target vessel-related cardiac death or myocardial infarction and target vessel revascularization. Secondary outcomes included ST. (Un)adjusted hazard ratios (HR) for TVF were calculated with Cox regression. Results: No difference was observed in the incidence of TVF [HR: 1.03; 95% confidence intervals (CI): 0.651.65, P = 0.89] in patients continuing DAPT (n = 4,249) at 30 days versus patients stopped (n = 309), and HR: 0.82 (95% CI: 0.551.23, P = 0.34) in patients continuing DAPT (n = 2,654) at 6 months versus patients stopped [n = 1,408] DAPT). Furthermore, no differences were observed in ST. Even after addition of identified independent predictors for TVF, adjusted TVF hazards were comparable. Conclusions: In a post-hoc analysis of e-HEALING, duration of DAPT was not associated with the occurrence of the outcomes TVF or ST. The Genous stent may be an attractive treatment especially in patients at increased risk for (temporary) cessation of DAPT or bleeding. (C) 2011 Wiley Periodicals, Inc.
Resumo:
The aim of this study was to investigate the effects of beta-alanine supplementation on exercise capacity and the muscle carnosine content in elderly subjects. Eighteen healthy elderly subjects (60-80 years, 10 female and 4 male) were randomly assigned to receive either beta-alanine (BA, n = 12) or placebo (PL, n = 6) for 12 weeks. The BA group received 3.2 g of beta-alanine per day (2 x 800 mg sustained-release Carnosyn (TM) tablets, given 2 times per day). The PL group received 2 x (2 x 800 mg) of a matched placebo. At baseline (PRE) and after 12 weeks (POST-12) of supplementation, assessments were made of the muscle carnosine content, anaerobic exercise capacity, muscle function, quality of life, physical activity and food intake. A significant increase in the muscle carnosine content of the gastrocnemius muscle was shown in the BA group (+85.4%) when compared with the PL group (+7.2%) (p = 0.004; ES: 1.21). The time-to-exhaustion in the constant-load submaximal test (i.e., TLIM) was significantly improved (p = 0.05; ES: 1.71) in the BA group (+36.5%) versus the PL group (+8.6%). Similarly, time-to-exhaustion in the incremental test was also significantly increased (p = 0.04; ES 1.03) following beta-alanine supplementation (+12.2%) when compared with placebo (+0.1%). Significant positive correlations were also shown between the relative change in the muscle carnosine content and the relative change in the time-to-exhaustion in the TLIM test (r = 0.62; p = 0.01) and in the incremental test (r = 0.48; p = 0.02). In summary, the current data indicate for the first time, that beta-alanine supplementation is effective in increasing the muscle carnosine content in healthy elderly subjects, with subsequent improvement in their exercise capacity.
Resumo:
Objectives To investigate the effect of Nintendo Wii (TM)-based motor cognitive training versus balance exercise therapy on activities of daily living in patients with Parkinson's disease. Design Parallel, prospective, single-blind, randomised clinical trial. Setting Brazilian Parkinson Association. Participants Thirty-two patients with Parkinson's disease (Hoehn and Yahr stages 1 and 2). Interventions Fourteen training sessions consisting of 30 minutes of stretching, strengthening and axial mobility exercises, plus 30 minutes of balance training. The control group performed balance exercises without feedback or cognitive stimulation, and the experimental group performed 10 Wii Fit (TM) games. Main outcome measure Section II of the Unified Parkinson's Disease Rating Scale (UPDRS-II). Randomisation Participants were randomised into a control group (n = 16) and an experimental group (n = 16) through blinded drawing of names. Statistical analysis Repeated-measures analysis of variance (RM-ANOVA). Results Both groups showed improvement in the UPDRS-II with assessment effect (RM-ANOVA P < 0.001, observed power = 0.999). There was no difference between the control group and the experimental group before training {8.9 [standard deviation (SD) 2.9] vs 10.1 (SD 3.8)}, after training [7.6 (SD 2.9) vs 8.1 (SD 3.5)] or 60 days after training [8.1 (SD 3.2) vs 8.3 (SD 3.6)]. The mean difference of the whole group between before training and after training was -0.9 (SD 2.3, 95% confidence interval -1.7 to -0.6). Conclusion Patients with Parkinson's disease showed improved performance in activities of daily living after 14 sessions of balance training, with no additional advantages associated with the Wii-based motor and cognitive training. Registered on http://www.clinicaltrials.gov (identifier: NCT01580787). (C) 2012 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Resumo:
Empirical approaches and, more recently, physical approaches, have grounded the establishment of logical connections between radiometric variables derived from remote data and biophysical variables derived from vegetation cover. This study was aimed at evaluating correlations of dendrometric and density data from canopies of Eucalyptus spp., as collected in Capao Bonito forest unit, with radiometric data from imagery acquired by the TM/Landsat-5 sensor on two orbital passages over the study site (dates close to field data collection). Results indicate that stronger correlations were identified between crown dimensions and canopy height with near-infrared spectral band data (rho(s)4), irrespective of the satellite passage date. Estimates of spatial distribution of dendrometric data and canopy density (D) using spectral characterization were consistent with the spatial distribution of tree ages during the study period. Statistical tests were applied to evaluate performance disparities of empirical models depending on which date data were acquired. Results indicated a significant difference between models based on distinct data acquisition dates.
Resumo:
The National Institute for Clinical Excellence (NICE) guidelines recommend the use of bare-metal stents (BMS) in non-complex lesions with a low risk of restenosis (diameter a parts per thousand yen3 mm and lesion length a parts per thousand currency sign15 mm) and the use of drug-eluting stents (DES) in more complex lesions with a high risk of restenosis (diameter < 3.0 mm or lesion length > 15 mm). However, the guidelines were created based on studies evaluating BMS and DES only. We performed an analysis of patients undergoing non-urgent percutaneous coronary intervention with the novel endothelial cell capturing stent (ECS). The ECS is coated with CD34(+) antibodies that attract circulating endothelial progenitor cells to the stent surface, thereby accelerating the endothelialization of the stented area. We analyzed all patients enrolled in the worldwide e-HEALING registry that met the NICE criteria for either low-risk or high-risk lesions and were treated with a parts per thousand yen1 ECS. The main study outcome was target vessel failure (TVF) at 12-month follow-up, defined as the composite of cardiac death or MI and target vessel revascularization (TVR). A total of 4,241 patients were assessed in the current analysis. At 12-month follow-up, TVF occurred in 7.0% of the patients with low-risk lesions and in 8.8% of the patients with high-risk lesions (p = 0.045). When evaluating the diabetic patients versus the non-diabetic patients per risk group, no significant differences were found in TVF, MI or TVR in either risk group. The ECS shows good clinical outcomes in lesions carrying either a high or a low risk of restenosis according to the NICE guidelines with comparable rates of cardiac death, myocardial infarction, and stent thrombosis. The TVF rate with ECS was slightly higher in patients with high-risk lesions, driven by higher clinically driven TLR. The risk of restenosis with ECS in patients carrying high-risk lesions needs to be carefully considered relative to other risks associated with DES. Furthermore, the presence of diabetes mellitus did not influence the incidence of TVF in either risk group.
Resumo:
Structural and electronic properties of the PtnTM55-n (TM = Co, Rh, Au) nanoalloys are investigated using density functional theory within the generalized gradient approximation and employing the all-electron projected augmented wave method. For TM = Co and Rh, the excess energy, which measures the relative energy stability of the nanoalloys, is negative for all Pt compositions. We found that the excess energy has similar values for a wide range of Pt compositions, i.e., n = 20-42 and n = 28-42 for Co and Rh, respectively, with the core shell icosahedron-like configuration (n = 42) being slightly more stable for both Co and Rh systems because of the larger release of the strain energy due to the smaller atomic size of the Co and Rh atoms. For TM = Au, the excess energy is positive for all compositions, except for n = 13, which is energetically favorable due to the formation of the core-shell structure (Pt in the core and Au atoms at the surface). Thus, our calculations confirm that the formation of core-shell structures plays an important role to increase the stability of nanoalloys. The center of gravity of the occupied d-states changes almost linearly as a function of the Pt composition, and hence, based on the d-band model, the magnitude of the adsorption energy of an adsorbate can be tuned by changing the Pt composition. The magnetic moments of PtnCo55-n decrease almost linearly as a function of the Pt composition; however, the same does not hold for PtRh and PtAu. We found an enhancement of the magnetic moments of PtRh by a few times by increasing Pt composition, which we explain by the compression effects induced by the large size of the Pt atoms compared with the Rh atoms.
Resumo:
A doença de Dent é uma tubulopatia ligada ao X causada por mutações no gene que codifica o canal de cloro CLCN-5 e é caracterizada por proteinúria de baixo peso molecular, hipercalciúria, nefrocalcinose e insuficiência renal. Vários casos têm sido descritos, nos quais o único sintoma na apresentação foi proteinúria assintomática e glomerulosclerose global ou segmentar. A insuficiência renal nesses pacientes pode ser causada pela hipercalciúria e proteinúria persistente. Portanto, o inibidor da enzima de conversão da angiotensina e os tiazídicos poderiam ser úteis. O objetivo desta pesquisa é relatar os efeitos destas drogas em dois pacientes com doença de Dent tipo 1 com mutações novas. Neste relato não foram observadas correlações significativas entre dose de hidroclorotiazida e calciúria e entre enalapril e proteinúria. Este achado é importante, pois, sendo pacientes poliúricos, o uso destas drogas poderia prejudicar a função renal
Resumo:
INTRODUÇÃO: A mais comum indicação de correção cirúrgica de átrio esquerdo gigante está associada à insuficiência da valva mitral, com ou sem fibrilação atrial. Diversas técnicas para este fim já estão descritas com resultados variáveis. OBJETIVO: Apresentar a experiência inicial com a técnica da ressecção triangular tangencial (Pomerantzeff). MÉTODOS: De 2002 a 2010, quatro pacientes foram submetidos a operação da valva mitral com redução do volume do átrio esquerdo pela técnica da ressecção triangular tangencial em nosso serviço. Três pacientes eram do sexo feminino. A idade variou de 21 a 51 anos. Os quatro pacientes encontravam-se com fibrilação atrial. A fração de ejeção do ventrículo esquerdo no pré-operatório variava de 38% a 62%. O diâmetro do átrio esquerdo variou de 78 a 140 mm. Após o tratamento da disfunção mitral, o átrio esquerdo foi reduzido por meio de ressecção triangular tangencial da sua parede posterior, entre as veias pulmonares, para evitar distorções anatômicas do anel mitral ou veias pulmonares, reduzindo a tensão na linha de sutura. RESULTADOS: Tempo médio de internação hospitalar foi de 21,5 ± 6,5 dias. O tempo de circulação extracorpórea médio foi de 130 ± 30 minutos. Não houve sangramento cirúrgico ou mortalidade no período pós-operatório. Todos os pacientes tiveram o ritmo sinusal restabelecido na saída de circulação extracorpórea, mantendo esse ritmo no pós-operatório. O diâmetro médio do átrio esquerdo foi reduzido em 50,5 ± 19,5%. A fração de ejeção do ventrículo esquerdo melhorou em todas as pacientes. CONCLUSÃO: Os resultados iniciais com essa técnica têm demonstrado redução efetiva do átrio esquerdo.
Resumo:
OBJETIVO: Permanecem as controvérsias sobre a utilização de circulação extracorpórea (CEC) na cirurgia de revascularização miocárdica (CRM). O objetivo deste estudo foi avaliar o impacto do 2000 Bernstein Parsonnet (2000BP) e EuroSCORE (EU) para escolha de CEC na CRM. MÉTODOS: Foram submetidos à CRM 1.551 pacientes consecutivos. CEC foi utilizada em 1.121 (72,3%) pacientes. O desempenho do 2000BP e EU para a amostra foi avaliado mediante testes de calibração, discriminação e correlação. Para ambos os escores de risco, o aumento do valor do escore e a presença de CEC tiveram relação direta com maior chance de óbito (P<0,05). Portanto, com essas duas variáveis foi construído um modelo de regressão logística para cada escore de risco, com a finalidade de determinar em que valor do escore a presença de CEC aumenta significativamente a chance de óbito. RESULTADOS: A calibração, ao igual que a área abaixo da curva ROC para o grupo com CEC [2000BP=0,80; EU=0,78] e sem CEC [2000BP=0,81; EU=0,85] foram adequadas. A correlação de Spearman para os grupos com e sem CEC foi de 0,66 (P<0,001) e 0,62 (P<0,001), respectivamente. No 2000BP, para um valor>17,75, a presença de CEC aumentou a chance de óbito para 7,4 [IC95% (4,4-12,3), P<0,0001]. No EU, para um valor>4,5, a presença de CEC aumentou a chance de óbito para 5,4 [IC95% (3,3-9), P<0,0001]. CONCLUSÃO: Na tomada de decisões, o 2000BP>17,75 ou o EU>4,5 orientam a identificar pacientes que quando submetidos a CRM com CEC têm chance de óbito aumentada significativamente.
Resumo:
OBJETIVOS: descrever o conhecimento dos enfermeiros das Unidades Distritais Básicas de Saúde do município de Ribeirão Preto, SP, Brasil, acerca da violência contra a mulher, particularmente aquela cometida pelo parceiro íntimo. MÉTODOS: estudo quantitativo, transversal e descritivo. Participaram 51 enfermeiros, extraídos de um estudo maior com 221 profissionais de saúde. Os dados foram coletados por meio de questionário que investigava o conhecimento em relação à violência cometida contra as mulheres. RESULTADOS: os enfermeiros acertaram de 76% a 90,2% das questões sobre definição de violência de gênero e 78% obtiveram altos escores em questões sobre epidemiologia da violência; no entanto, 70,6% demonstraram desconhecer sua epidemiologia nos serviços de pré-natal. 83,7% dos enfermeiros demonstraram bom conhecimento sobre como abordar as vítimas para obter a revelação da violência ocorrida e 52% demonstraram conhecimento elevado sobre o manejo dos casos. CONCLUSÕES: os enfermeiros conhecem bem a definição de violência, têm conhecimentos sobre o manejo de casos, a necessidade de notificação e encaminhamentos de casos em situação de risco. Entretanto, desconhecem características epidemiológicas importantes da violência contra a mulher, o que pode ser uma barreira para a atuação dos enfermeiros no atendimento a mulheres em situação de risco, principalmente durante a atenção no pré-natal.
Resumo:
Considerando a indisponibilidade de equipamentos avançados de aquisição de imagens nos centros cirúrgicos da maioria dos centros hospitalares e a importância fundamental que têm para o cirurgião uma visualização imediata do implante coclear logo após sua inserção, uma boa opção é a utilização da radiografia convencional. OBJETIVO: Descrever um método radiográfico rápido prático e de baixo custo, que permita avaliar não só a posição, mas também a integridade dos eletrodos, na instalação do implante coclear. MATERIAL E MÉTODO: Foram analisadas radiografias de 262 pacientes submetidos à cirurgia de implante coclear entre Março/2005 e Outubro/2008, com radiografia transoperatória, logo após a inserção dos eletrodos. As radiografias foram analisadas pelo cirurgião no transoperatório e, posteriormente, pelo médico radiologista. RESULTADOS: Foram analisadas 524 radiografias das quais, 95,61% apresentavam técnica adequada, com posicionamento do paciente dentro da técnica descrita neste estudo e boa visualização dos eletrodos, sendo consideradas satisfatórias e 4,39% apresentavam técnica inadequada e/ou visualização insatisfatória dos eletrodos, sendo consideradas insatisfatórias. CONCLUSÃO: Apesar dos aparelhos de Raios X portáteis possuírem limitações, utilizando técnicas e acessórios adequados, é possível conseguir radiografias com resultados satisfatórios para visualização dos implantes cocleares.