843 resultados para (acidified sample)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O uso dos tamanhos de amostras adequados nas unidades experimentais melhora a eficiência da pesquisa. Foi conduzido um experimento no ano agrícola 2004/2005 em Santa Maria, Rio Grande do Sul, com o objetivo de estimar o tamanho de amostra para o comprimento de espiga, o diâmetro de espiga e de sabugo, o peso da espiga, dos grãos por espiga, do sabugo e de 100 grãos, o número de fileiras de grãos por espiga, o número de grãos por espiga e o comprimento dos grãos de dois híbridos simples (P30F33 e P Flex), dois híbridos triplos (AG8021 e DG501) e dois híbridos duplos (AG2060 e DKB701) de milho. Para uma precisão de 5% (D5), características de peso (peso de espiga despalhada, de grãos, de sabugo e de 100 grãos) podem ser amostradas com 21 espigas, características de tamanho (comprimento de espiga e de grão, diâmetro de espiga e de sabugo) com oito espigas, e dados de contagem (número de grãos e de fileiras) com 13 espigas. O tamanho de amostra é variável em função da característica da espiga e do tipo de híbrido: simples, triplo ou duplo. A variabilidade genética existente entre os híbridos de milho, na forma crescente: simples, triplo e duplo, não reflete na mesma ordem no tamanho de amostra de caracteres da espiga.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudo retrospectivo avaliando alterações laboratoriais hepáticas e potenciais interações medicamentosas em pacientes tratados para onicomicose. Foram avaliados 202 pacientes, sendo 82% do sexo feminino. em 273 exames de enzimas hepáticas, houve alterações em apenas 6%. Potenciais interações medicamentosas foram identificadas em 28% dos pacientes para imidazólicos e 14% para terbinafina. O risco de interações potenciais aumentou com a idade do paciente e o uso de múltiplas medicações.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amostra de Paracoccidioides brasiliensis isolada de vísceras (baço e fígado) de um tatu (Dasipus novencinctus) foi estudada do ponto de vista micológico e imunoquímico. O tatu havia sido capturado em área da usina hidroelétrica de Tucuruí (Estado do Pará). Este já havia sido considerado como reservatório enzoótico do Paracoccidioides brasiliensis naquela região. Esta amostra, conservada na Micoteca do Instituto de Medicina Tropical de São Paulo sob o número 135, apresenta todas as características de Paracoccidioides brasiliensis, com elevado poder antigênico e baixa virulência para cobaios e ratos Wistar. A demonstração do exo-antígeno específico do P. brasiliensis, representado pela glicoproteína de peso molecular 43 kDa, foi evidente através das técnicas de Imunodifusão Dupla, Imunoeletroforese, SDS-PAGE e Imunoblotting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Cerebrospinal fluid (CSF) is produced in the cerebral ventricles through ultrafiltration of plasma and active transport mechanisms. Evaluation of proteins in CSF may provide important information about the production of immunoglobulins within the central nervous system as well as possible disturbances in the blood-brain barrier. Objective: the objective of this study was to measure the concentration and fractions of protein in CSF samples using a membrane microconcentrator technique followed by electrophoresis, and to compare the protein fractions obtained with those in serum. Methods: CSF samples from 3 healthy dogs and 3 dogs with canine distemper virus infection were concentrated using a membrane microconcentrator having a 0.5 to 30,000 d nominal molecular weight limit (Ultrafree, Millipore, Billerica, MA, USA). Protein concentration was determined before and after concentration. Agarose gel electrophoresis was done on concentrated CSF samples, serum, and serial dilutions of one of the CSF samples. Results: Electrophoretic bands were clearly identified in densitometer tracings in CSF samples with protein concentrations as low as 1.3 g/dL. The higher CSF protein concentration in dogs with distemper was mainly the result of increased albumin concentration. Conclusion: the microconcentrating method used in this study enables characterization of the main protein fractions in CSF by routine electrophoresis and may be useful for interpreting the underlying cause of changes in CSF protein concentrations

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to develop an appropriate sample preparation procedure for the flame atomic absorption spectrometry determination of Cu, Fe, Mn, and, Zn in rocks used in organic agriculture as a source of macro- and micronutrients.Six different procedures were evaluated and are classified into three groups: (a) pressure digestion system with Teflon bombs, (b) conventional wet digestion in a digester heating block, and (c) closed microwave system with pressure and temperature control.Two standard reference materials and two commercial samples were analyzed. It was found that the closed microwave system required low reagent consumption, less time, and resulted in low contamination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent studies have shown that the (X) over bar chart with variable sampling intervals (VSI) and/or with variable sample sizes (VSS) detects process shifts faster than the traditional (X) over bar chart. This article extends these studies for processes that are monitored by both the (X) over bar and R charts. A Markov chain model is used to determine the properties of the joint (X) over bar and R charts with variable sample sizes and sampling intervals (VSSI). The VSSI scheme improves the joint (X) over bar and R control chart performance in terms of the speed with which shifts in the process mean and/or variance are detected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this retrospective investigation was to evaluate the dentoalveolar and skeletal cephalometric changes of the Bionator appliance on individuals with a Class II division 1 malocclusion. Lateral cephalograms of 44 patients were divided into two equal groups. The control group comprised 22 untreated Class II children (11 males, 11 females), with an initial mean age of 8 years 7 months who were followed without treatment for a period of 13 months. The Bionator group (111 males, 11 females) had an initial mean age of 10 years 8 months, and were treated for a mean period of 16 months. Lateral cephalometric headfilms were obtained of each patient and control at the beginning and end of treatment.The results showed that there were no changes in forward growth of the maxilla in the experimental group compared with the control group. However, the Bionator treatment produced a statistically significant increase in mandibular protrusion, and in total mandibular and body lengths. There were no statistically significant differences in craniofacial growth direction between the Bionator group and the control group, although the treated patients demonstrated a greater increase in posterior face height. The Bionator appliance produced labial tipping of the lower incisors and lingual inclination of the upper incisors, as well as a significant increase (P < 0.01) in mandibular posterior dentoalveolar height. The major effects of the Bionator appliance were dentoalveolar, with a smaller significant skeletal effect. The results indicate that the correction of a Class II division 1 malocclusion with the Bionator appliance is achieved not only by a combination of mandibular skeletal effects, but also by significant dentoalveolar changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection spectrophotometric system is proposed for phosphite determination in fertilizers by the molybdenum blue method after the processing of each sample two times on-line without and with an oxidizing step. The flow system was designed to add sulfuric acid or permanganate solutions alternately into the system by simply displacing the injector-commutator from one resting position to another, allowing the determination of phosphate and total phosphate, respectively. The concentration of phosphite is obtained then by difference between the two measurents. The influence of flow rates, sample volume, and dimension of flow line connecting the injector-commutator to the main analytical channel was evaluated. The proposed method was applied to phosphite determination in commercial liquid fertilizers. Results obtained with the proposed FIA system were not statistically different from those obtained by titrimetry at the 95% confidence level. In addition, recoveries within 94 and 100% of spiked fertilizers were found. The relative standard deviation (n = 12) related to the phosphite-converted-phosphate peak alone was <= 3.5% for 800 mg L-1 P (phoshite) solution. Precision due to the differences of total phosphate and phosphate was 1.1% for 10 mg L-1 P (phosphate) + 3000 mg L-1 P (phosphite) solution. The sampling rate was calculated as 15 determinations per hour, and the reagent consumption was about 6.3 mg of KMnO4, 200 mg of (NH4)(6)Mo7O24 center dot 4H(2)O, and 40 mg of ascorbic acid per measurement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The efficiency of different methods for the decontamination of glassware used for the analysis of dissolved organic carbon (DOC) was tested using reported procedures as well as new ones proposed in this work. A Fenton solution bath (1.0 mmol L-1 Fe2+ and 100 mmol L-1 H2O2) for 1 h or for 30 min employing UV irradiation showed to combine simplicity, low cost and high efficiency. Using the optimized cleaning procedure, the DOC for stored UV-irradiated ultrapure water reached concentrations below the limit of detection (0.19 mu mol C L-1). Filtered (0.7 mu m) rain samples maintained the DOC integrity for at least 7 days when stored at 4 degrees C. The volatile organic carbon (VOC) fraction in the rain samples collected at two sites in São Paulo state (Brazil) ranged from 0% to 56% of their total DOC content. Although these high-VOC concentrations may be derived from the large use of ethanol fuel in Brazil, our results showed that when using the high-temperature catalytic oxidation technique, it is essential to measure DOC rather than non-purgeble organic carbon to estimate organic carbon, since rainwater composition can be quite variable, both geographically and temporally. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluoride toothpastes are a risk factor for the development of dental fluorosis. Products with low fluoride content offer a higher security, but their effectiveness must be proven. The aim of this in vitro study was to compare two acidified toothpastes with low fluoride concentration (412 and 550 mu g F/g) with neutral toothpastes. Bovine enamel blocks were selected by surface microhardness (SMH) and randomized to twelve groups of 13, according to the fluoride concentration in toothpaste (placebo, 275, 412, 550 or 1,100 jig F/g) and pH (7.0 or 5.5). Two commercially available toothpastes were also studied: a 1,100-mu g F/g, pH 7.0 paste (positive control) and a children's paste (500 mu g F/g, pH 7.0). The blocks were subjected to pH cycling for 7 days. The toothpaste treatment was done twice daily. Surface and cross-sectional microhardnesses were assessed to calculate the percentage change of SMH (%SMH) and the mineral loss (Delta Z). The amount of fluoride, calcium and phosphorus in the solutions after the pH cycling was also analyzed. Compared to neutral toothpastes, the acidified toothpastes reduced the %SMH in all F concentrations. Higher F and lower Ca and P concentrations were found in solutions for the acidified toothpastes. Regarding AZ, only the positive control, 1,100-mu g F/g (acidified and neutral) groups were not statistically different. The acidified toothpastes showed a dose-response relationship with all variables. For the low-fluoride toothpastes evaluated, only the 550-mu g F/g acidified paste had the same anticariogenic action as the 1,100-mu g F/g neutral paste.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method was developed using the multi-element graphite furnace atomic absorption spectrometry technique for the direct and simultaneous determination of As, Cu, and Pb in Brazilian sugar cane spirit (cachaqa) samples. Also employed was the end-capped transversely heated graphite atomizer (THGA) with platforms pre-treated with W permanent modifier and co-injection of Pd/Mg(NO3)(2). Pyrolysis and atomization temperature curves were established in a cachaqa medium (1+1; v/v) containing 0.2% (v/v) HNO3 and spiked with 20 mu g L-1 As and Pb and 200 mu g L-1 Cu. The effect of the concentration of major elements usually present in cachaqa matrices (Ca, Mg, Na, and K) and ethanol on the absorbance of As, Cu, and Pb was investigated. Analytical working solutions of As, Cu, and Pb were prepared in 10% (v/v) ethanol plus 5.0 mg L-1 Ca, Mg, Na, and K. Acidified to 0.2% (v/v) HNO3, these solutions were suitable to build calibration curves by matrix matching. The proposed method was applied to the simultaneous determination of As, Cu, and Pb in commercial sugar cane spirits. The characteristic mass for the simultaneous determination was 16 pg As, 119 pg Cu, and 28 pg Pb. The pretreated tube lifetime was about 450 firings. The limit of detection (LOD) was 0.6 mu g L-1 As, 9.2 mu g L-1 Cu, and 0.3 pig L-1 Pb. The found concentrations varied from 0.81 to 4.28 mu g L-1 As, 0.28 to 3.82 mg L-1 Cu and 0.82 to 518 mu g L-1 Pb. The recoveries of the spiked samples varied from 94-112% (As), 97-111% (Cu), and 95-101% (Pb). The relative standard deviation (n=12) was 6.9%, 7.4%, and 7.7% for As, Cu, and Pb, respectively, present in a sample at 0.87 mu g L-1, 0.81 mg L-1, and 38.9 mu g L-1 concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection system with online sample preparation is proposed for the determination of phosphite in liquid fertilizers by spectrophotometry. After loop-based injection, phosphite is oxidized by an acidic permanganate solution (1.0 10(-2) mol L-1 KMnO4 + 1.0 mol L-1 H2SO4) in a heated reactor (50 degreesC). The phosphate generated is then determined by the molybdenum blue method. Influence of flow rates, temperature, and concentration and order of addition of reagents, sample volume, and reactor configuration for the blue complex formation on recorded signals were investigated. The pow system was applied to phosphite determination in commercial samples of liquid fertilizers. The proposed system handles about 80 samples per hour [0.05-0.40% (w/v) H3PO3; R = 0,9998], consuming about 80 muL sample, 1 mg KMnO4, 25 mg (NH)(6)Mo7O24, and Ia mg ascorbic acid per determination. Results are precise [relative standard deviation less than or equal to 3.5% for 0.1% (w/v) H3PO3, n = 12] and in agreement with those obtained by gravimetry at 95% confidence level. (C) 2000 John Wiley & Sons, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The absorption and luminescence spectra for the poly(p-phenylene vinylene)/sol-gel silica with different thermal treatments were measured. A considerable increase in the luminescence was observed for the polymer introduced into SiO2 matrix with thermal treatment at 120 degreesC. The thermal diffusivity of these samples was measured using the thermal lens technique, and the obtained value 3.3 x 10(-5) cm(2)/s (sample treated at 37 degreesC) is practically independent of the thermal treatment (37-150 degreesC). (C) 2003 Elsevier B.V. All rights reserved.