937 resultados para weak instruments
Resumo:
Fifty-four extracted human mandibular molars were embedded and sectioned at two levels. The reassembled mesial root canals were prepared with stainless-steel hand K-files (Flexofiles) and either Nitiflex or Mity nickel-titanium hand K-files using a push-pull anticurvature filing technique. Each of the three experimental groups contained 36 mesial canals randomly distributed. Superimposed pre- and postinstrumentation cross-sectional root images were magnified using a stereomicroscope and transferred to a computer for measurement and statistical analysis. The direction and extent of canal center movement were evaluated. At the apical level, the groups produced no significant difference of direction of canal center movement. In cervical sections, all groups tended to move in a distolingual direction. The three groups, however, produced no significant difference in the cervical sections in the extent of canal center movement. In apical sections, Nitiflex produced the least canal center movement. Copyright © 1999 by The American Association of Endodontists.
Resumo:
We investigate the weak interaction emission of spin-1/2 fermions from accelerated currents. As particular applications, we analyze the decay of uniformly accelerated protons and neutrons, and the neutrino-antineutrino emission from uniformly accelerated electrons. The possible relevance of our results to astrophysics is also discussed.
Magnetic behavior of poly(3-methylthiophene): Metamagnetism and room-temperature weak ferromagnetism
Resumo:
A weak ferromagnetic phase is shown in pressed pellets of partially doped poly(3-methylthiophene) (P3MT) in the whole range from 1.8 to 300 K in magnetic measurements. Thermoremanence data have been used to estimate the suppression of this phase to be around 815 K. We also show that instead of the classical antiferromagnetism for the first-order interaction that gives weak ferromagnetism as a second-order effect, metamagnetic behavior is observed. X-band electron spin resonance (ESR) measurements and magnetization measurements allowed us to estimate that 8.1% of the total number of spins contributes to the weak ferromagnetism at room temperature. The doping level obtained from the ESR data is in good agreement with that estimated from electron dispersive spectroscopy measurements.
Resumo:
Monte Carlo simulations have been performed to investigate the structure and hydrogen bonds formation in liquid acetaldehyde. An all atom model for the acetaldehyde have been optimized in the present work. Theoretical values obtained for heat of vaporisation and density of the liquid are in good agreement with experimental data. Graphics of radial distribution function indicate a well structured liquid compared to other similar dipolar organic liquids. Molecular mechanics minimization in gas phase leads to a trimer of very stable structure. The geometry of this complex is in very good agreement with the rdf. The shortest site-site correlation is between oxygen and the carbonyl hydrogen, suggesting that this correlation play a important role in the liquid structure and properties. The O⋯H average distance and the C-H⋯O angle obtained are characteristic of weak hydrogen bonds.
Resumo:
The objective of this study was to evaluate, through scanning electronic microscopy, the effect of sharpening with different sharpening stones on the cutting angle of periodontal curettes (Gracey 5-6), and the influence on root surfaces after debridement and planing. The experimental model consisted of two different phases. In the first, the cutting angles of fifteen stainless steel Gracey 5-6 curettes were analyzed under a scanning electronic microscope after being sharpened with different types of stones. In the second phase, the root surfaces of 25 newly extracted teeth were evaluated with a scanning electronic microscope after being debrided with curettes sharpened with different stones. Analysis of the results showed that the synthetic stones (aluminum oxide and carborundum) are more abrasive and produce more irregular cutting angles, whereas Arkansas stones are less abrasive and produce smoother and more defined cutting angles. There was no significant statistical differences among the five groups tested with regard to the degree of irregularity of the root surfaces after instrumentation.
Resumo:
SAOZ (Systeme d'Analyse par Observations Zenithales) is a ground-based UV-Visible zenith-sky spectrometer installed between 1988 and 1995 at a number of NDSC stations at various latitudes on the globe. The instrument is providing ozone and NO2 vertical columns at sunrise and sunset using the Differential Optical Absorption Spectroscopy (DOAS) technique in the visible spectral range. The ERS-2 GOME Ozone Monitoring Experiment (GOME) in 1995 was the first satellite mission to provide a global picture of atmospheric NO 2 with reasonable spatial and temporal resolution. It was then followed by SCanning ImAging spectroMeter for Atmospheric ChartographY (SCIAMACHY) onboard ENVISAT in 2002, and Ozone Monitoring Instrument (OMI) onboard EOS-AURA in 2004, with a similar capacity to monitor total NO 2. All these instruments are nadir viewing mapping spectrometers, applying the DOAS technique in the visible for deriving the NO2 total column. Here we present the results of NO2 long-term comparisons between GOME and SAOZ for the whole period of GOME operation since 1995 at all latitudes - tropics, mid-latitudes and polar regions - in both hemispheres. Comparisons are also shown with the most recently available SCIAMACHY and OMI data in 2004-2005. Overall, the daytime satellite measurements (around noon) are found consistent with sunrise ground-based data, with an average smaller difference at the tropics and mid-latitudes than in the polar areas in the summer. The agreement is even improved after correcting for the NO2 photochemical change between sunrise and the satellite overpass using a box model. However, some seasonal dependence of the difference between ground-based and satellite total NO2 still remains, related to the accuracy of photochemical simulations and the set of NO2 air mass factors used in the retrievals of both systems.
Resumo:
We define by simple conditions two wide subclasses of the socalled Arnoux-Rauzy systems; the elements of the first one share the property of (measure-theoretic) weak mixing, thus we generalize and improve a counterexample to the conjecture that these systems are codings of rotations; those of the second one have eigenvalues, which was known hitherto only for a very small set of examples.
Resumo:
Includes bibliography
Resumo:
After a short introduction to the nonmesonic weak decay (NMWD) ΛN→nN of Λ-hypernuclei we discuss the long-standing puzzle on the ratio Γn/Γp, and some recent experimental evidences that signalized towards its final solution. Two versions of the Independent-Particle-Shell-Model (IPSM) are employed to account for the nuclear structure of the final residual nuclei. They are: (a) IPSM-a, where no correlation, except for the Pauli principle, is taken into account, and (b) IPSM-b, where the highly excited hole states are considered to be quasi-stationary and are described by Breit-Wigner distributions, whose widths are estimated from the experimental data. We evaluate the coincidence spectra in Λ 4He, Λ 5He, Λ 12C, Λ 16O, and Λ 28Si, as a function of the sum of kinetic energies EnN=En+EN for N=n, p. The recent Brookhaven National Laboratory experiment E788 on Λ 4He, is interpreted within the IPSM. We found that the shapes of all the spectra are basically tailored by the kinematics of the corresponding phase space, depending very weakly on the dynamics, which is gauged here by the one-meson-exchange- potential. In spite of the straightforwardness of the approach a good agreement with data is achieved. This might be an indication that the final-state- interactions and the two-nucleon induced processes are not very important in the decay of this hypernucleus. We have also found that the π+K exchange potential with soft vertex-form-factor cutoffs (Λπ≈0. 7GeV, ΛK≈0.9GeV), is able to account simultaneously for the available experimental data related to Γp and Γn for Λ 4H, and Λ 5He. © 2010 American Institute of Physics.
Resumo:
Includes bibliography
Resumo:
This study evaluated the efficacy of 2 types of rotary instruments employed in association with sodium hypochlorite (NaOCl) or EDTA in removing calcium hydroxide (CH) residues from root canals dentin walls. Forty-two mandibular human incisors were instrumented with the ProTaper System up to F2 instrument, irrigated with 2.5% NaOCl followed by 17% EDTA and filled with a CH intracanal dressing. After 7 days, the CH dressing was removed using 4 techniques: NiTi rotary instrument size 25, 0.06 taper (K3 Endo) and irrigation with 17% EDTA (Group 1), NiTi rotary F1 instrument (ProTaper) and irrigation with 17% EDTA (Group 2), NiTi rotary instrument size 25, 0.06 taper and irrigation with 2.5% NaOCl (Group 3) and NiTi rotary F1 instrument and irrigation with 2.5% NaOCl (Group 4). Two roots without intracanal dressing were used as negative controls. Teeth were evaluated by scanning electron microscopy, in the cervical and apical canal thirds. None of the techniques removed the CH dressing completely. In the apical and cervical thirds, F1 instrument was better than instrument size 25, 0.06 taper in removing CH residues (p<0.05), regardless of the final irrigating solution. No difference was found between the irrigating solutions in the groups of F1 instrument and of instrument size 25, 0.06 taper (p>0.05). The negative controls had no CH residues on the dentin walls. In conclusion, the ProTaper F1 instrument was better than K3 Endo instrument size 25, 0.06 taper in the removal of CH intracanal medication, regardless of irrigating solution used.
Resumo:
Includes bibliography
Insurance underwriter or financial development fund: what role for reserve pooling in Latin America?
Resumo:
Includes bibliography
Resumo:
Using two standard cycle methodologies (Classical and Deviation Cycle) and a comprehensive sample of 83 countries worldwide, including all developing regions, we show that the Latin American and Caribbean cycle exhibits two distinctive features. First, and most importantly, its expansion performance is shorter and for the most par less imtense than that of the rest of the regions considered, and in particular than that of East Asia and the Pacific, East Asia and the Pacific's expansions last five years longer than those of LAC, and its output gain is 50% greater than that of LAC. Second, LAC tends to exhibit contractions that are not significantly different in terms of duration and amplitude than t those of other regions. Both these features imply that the complete Latin American and Caribbean cycle has, overall, the shortest duration and smallest amplitude in relation to other regions. The specificities of the Latin American and Caribbean cycle are not confined to the short run. These are also reflected in variables such as productivity and investment, which are linked to long-run growth. East Asia and the Pacific's cumulative gain in labor productivity during the expansionary phase is twice that of LAC. Moreover, the evidence also shows that the effects of the contraction in public investment surpass those of the expansion leading to a declining trend over the entire cycle. In this sense we suggest that policy analysis needs to increase its focus on the expansionary phase of the cycle. Improving our knowledge of the differences in the expansionary dynamics of countries and regions, can further our understanding of the differences in their rates of growth and levels of development. We also suggest that while, the management of the cycle affects the short-run fluctuations of economic activity and hence volatility, it is not trend neutral. Hence, the effects of aggregate demand management policies may be more persistent over time and less transitory than currently thought.
Resumo:
Influence of cutting instruments and The aim of this study was to analyze the hybrid layer in noncarious dentin prepared by different cutting instruments and restored with composite resin. The cavities were randomly prepared in 40 specimens using a high-speed diamond bur (KG Sorensen 1013) and an ultrasonic tip (CVDentus C22). The cavities were restored with composite resin by varying the adhesive system between the Adper™ Single Bond (2 x 1 system, primer+adhesive) and the Prompt L-Pop™ (3 x 1 system, self-etching). The restorations were hemisected longitudinally and analyzed in the SEM (Scanning electron microscopy) in order to evaluate the hybrid layer and resinous tags characteristics, using scores ranging from 1 to 6. The Pearson test revealed a high correlation coefficient and good significance levels for both intra- and inter-raters values (r=0.90). The data were statistically analyzed using the Mann-Whitney test (P≤0.05). A larger proportion of regular hybrid layers with numerous tags were observed in the dentin prepared using the high-speed diamond burs and restored with a 2 × 1 adhesive system. Alternatively, the 3 × 1 adhesive system promoted the generation of a thin hybrid layer with few tags. After preparation using an ultrasonic tip revealed few or no tags after the preparation and 2 × 1 or 3 × 1 adhesive system application. The high-speed diamond burs produced a dentin surface that was more favorable to restorative material adhesion than the ultrasonic tips, regardless of the adhesive system used.