977 resultados para preparo intestinal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intestinal infection with Salmonella enterica serotype Enteritidis, a food-borne infection spread to humans especially through contaminated eggs and egg-products as well as undercooked contaminated fresh meat, is the most common cause of intestinal inflammation in the European Union. Enteritis caused by Salmonella Enteritidis is characterized by fever, diarrhoea and abdominal pain. The disruption of the intestinal epithelial barrier function contributes to diarrhoea and is responsible for the perpetuation of the inflammatory process. In this sense, oxidative stress and the proinflammatory cytokines TNF-α, IFN-γ and IL-1β are described to induce the disorganization of the tight junctions (TJ), the most apical epithelial intercellular junctions and responsible for the paracellular permeability. The interest of this chapter relies not only in the investigation dealing with the mechanisms of TJ regulation but also in the contribution to the development of new tools for the prevention of epithelial barrier disruption in enteritis caused by Salmonella Enteritidis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work shows some laboratory waste management developed in order to recover some elements or to prepare the waste for a correct final disposal. The 25 elements chosen cover basically all chemical behaviors found for the metals in the Periodic Table. The treatments adopted were based on the classical behavior in aqueous solution (wet chemistry) but an important condition for a full success was the previous knowledge of the qualitative composition of the wastes treated. Some general trends were found: the final liquid waste was always saline and normally presented a higher volume than the original waste; most original wastes were acid in nature; steps such as solid-liquid separation, washing, evaporating and calcining were currently performed. This work was also a very good experience in chemistry in solution for students and showed them the need of treating wastes for a better environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

MIPs are synthetic polymers that are used as biomimetic materials simulating the mechanism verified in natural entities such as antibodies and enzymes. Although MIPs have been successfully used as an outstanding tool for enhancing the selectivity or different analytical approaches, such as separation science and electrochemical and optical sensors, several parameters must be optimized during their synthesis. Therefore, the state-of-the-art of MIP production as well as the different polymerization methods are discussed. The potential selectivity of MIPs in the extraction and separation techniques focusing mainly on environmental, clinical and pharmaceutical samples as applications for analytical purposes is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hydrated sodium salt of EDTA, Na2H2Y·2H2O, cannot be used as a primary standard for titrations due to uncertainties in the water content. An alkalimetric titration of the homogenized solid in the presence of a small excess of BaCl2·2H2O allows one to titrate quantitatively the released two hydrogen cations with end-point indication by phenolphthalein or potentiometry. This leads one to calculate the average molar mass of the reagent and its water content, allowing to use it to prepare EDTA standard solutions. One titrated sample led to the formula Na2H2Y·1.876 H2O, and 370.01 g.mol-1 for the average molar mass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Colorectal cancer is a major health problem worldwide and many efforts have been done to delineate risk factors and develop screening strategies to reduce its incidence and mortality. Colorectal adenomas have been clearly considered preneoplastic lesions due to their potential malignant transformation via the adenoma-carcinoma sequence. Over the last years, intestinal microbiota has been studied in several diseases and it has been hypothesized that colonic microbiota could influence colorectal cancer pathogenesisObjective: The goal of this study is to analyse whether there is an association between the fecal microbiota profiling and the presence and progression of colorectal adenomas, detected in population undergoing colonoscopy, to better understand the role of intestinal microbiota in colorectal carcinogenesisDesign: A cross-sectional study in the Gastroenterology Department at Hospital Universitari Doctor Josep Trueta in Girona, in a period of time of two yearsParticipants: General population undergoing screening or diagnostic colonoscopy in the Digestive Endoscopy UnitOutcomes: Identification and characterization of intestinal microbiota in stool samples from healthy patients and patients with low and high risk colorectal adenomas

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experiments simple, short and efficient for experimental disciplines in undergraduate courses in Chemistry are an excellent opportunity for students to consolidate the learning of theoretical concepts in classical chemical transformations. The use of a safe reagent, of low cost and easy access is the motivation for this communication, that describes the use of trichloroisocyanuric acid - a chlorinating agent used in the treatment of swimming pool water - for the chlorination of acetanilide, an intermediate in the preparation of para-chloroaniline.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work deals with paint decomposition methods for major, minor and trace elements determination. Three methods were investigated: (1) decomposition in closed quartz vessel and heating in microwave oven; (2) decomposition in open vessel using HNO3 and ashing, following the ASTM D 3335-85a method; and (3) decomposition in open vessel using HNO3 + HF and ashing. Paints of different types and colours were analyzed, in which several elements were determined using inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP OES). It was observed that method (1) is appropriate for trace, minor and major elements determination, while method (3) is appropriate for Ti.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review attempts to provide an updated overview of the Quick, Easy, Cheap, Effective, Ruged and Safe (QuEChERS) multiresidue extraction method, that involves initial extraction in acetonitrile, an extraction/partition step after the addition of salt, and a cleanup step utilizing dispersive solid phase extraction. QuEChERS method is nowadays the most applied extraction method for the determination of pesticide residues in food samples, providing acceptable recoveries for acidic, neutral and basic pesticides. Several applications for various food matrices (fruits, vegetables, cereals and others) in combination with chromatographic mass spectrometry analysis were presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pyrohydrolysis is proposed for fossil fuels sample preparation for further fluorine and chlorine determination. Samples were heated during 10 min at temperatures up to 1000 °C. Water vapor was passed through the reactor and the volatile products were condensed and collected in NH4OH solution. Fluoride was determined by potentiometry using an ion selective electrode (ISE) and Cl by ICP OES and DRC-ICP-MS. The results are in good agreement with certified values and the precision is better than 10% (n = 4). Sample preparation by means of pyrohydrolysis is relatively simple, whereas chlorine and fluorine can be determined at low concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The decomposition of detergent powder samples in a microwave oven and autoclave was evaluated. To establish the best experimental conditions a 2(5) factorial design was performed, varying the conditions in autoclave and microwave digestion and flow system parameters for the determination of phosphorus. The best composition was: 0.2 mL sulfuric acid; 500 W power and a 2 min time interval; 6 mmol L-1 of ascorbic acid and 16 mmol L-1 of molybdate to flow system. This factor levels use less reagents than the reference method. No statistically significant differences were found between the autoclave and microwave oven responses at the 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The restricted availability of water sources suitable for consumption and high costs for obtaining potable water has caused an increase of the conscience concerning the use. Thus, there is a high demand for "environmentally safe methods" which are according to the principles of Green Chemistry. Moreover, these methods should be able to provide reliable results for the analysis of water quality for various pollutants, such as phenol. In this work, greener alternatives for sample preparation for phenol determination in aqueous matrices are presented, which include: liquid phase microextraction, solid phase microextraction, flow analysis, cloud point extraction and aqueous two-phase systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The variability in aflatoxin B1 concentration among peanut subsamples of 4 sample preparation procedures was evaluated. For each procedure, 18 samples were prepared involving dry comminuting/homogenization or dry roughly comminuting followed by the preparation of a aqueous slurry. Ten analytical samples were withdrawn from each sample/procedure and analyzed by thin layer chromatography. The coefficient of variation (CV%) among each set of 10 analytical samples was assumed to be associated with the sample preparation procedure. The procedure that made use of a subsample mill and preparation of a subsample slurry, showed lower variability (CV%) among the analytical subsamples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study cellulose acetate butyrate (CAB) and carboxymehtylcellulose acetate butyrate (CMCAB) films adsorbed onto silicon wafers were characterized by means of ellipsometry, atomic force microscopy (AFM), sum frequency generation spectroscopy (SFG) and contact angle measurements. The adsorption behavior of lysozyme (LIS) or bovine serum albumin (BSA) onto CAB and CMCAB films was investigated. The amounts of adsorbed LIS or BSA onto CMCAB films were more pronounced than those onto CAB films due to the presence of carboxymethyl group in the CMCAB structure. Besides, the adsorption of BSA molecules on CMCAB films was more favored than that of LIS molecules. Antimicrobial effect of LIS bound to CAB or CMCAB layers was evaluated using Micrococcus luteus as substrate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of pesticide residues in water samples by Liquid Chromatography require sample preparation for extraction and enrichment of the analytes with the minimization of interferences to achieve adequate detection limits. The Solid Phase Extraction (SPE), Solid Phase Microextraction (SPME), Stir Bar Sorptive Extraction (SBSE) and Dispersive Liquid-Liquid Microextraction (DLLME) techniques have been widely used for extraction of pesticides in water. In this review, the principles of these sample preparation techniques associated with the analysis by Liquid Chromatography with Diode Array Detection (LC-DAD) or Mass Spectrometry (LC-MS) are described and an overview of several applications were presented and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the materials used in the recovery of estrogens from aqueous matrices by filtration and solid phase extraction were evaluated. The results showed that glass-fiber filters allow a recovery and repeatability compatible with this type of analysis, whereas cellulose esters lead to significant losses of the analytes, mainly due to adsorption processes. On the other hand, the transferring of the sample to the extraction cartridges should be carried out with glass or Teflon tubing, since the adsorption observed with other polymeric materials (eg. silicone, Tygon, polyethylene and PVC) dramatically reduces the recovery and repeatability of the extraction process.