970 resultados para non conventional instrument transformer
Resumo:
Transformer protection is one of the most challenging applications within the power system protective relay field. Transformers with a capacity rating exceeding 10 MVA are usually protected using differential current relays. Transformers are an aging and vulnerable bottleneck in the present power grid; therefore, quick fault detection and corresponding transformer de-energization is the key element in minimizing transformer damage. Present differential current relays are based on digital signal processing (DSP). They combine DSP phasor estimation and protective-logic-based decision making. The limitations of existing DSP-based differential current relays must be identified to determine the best protection options for sensitive and quick fault detection. The development, implementation, and evaluation of a DSP differential current relay is detailed. The overall goal is to make fault detection faster without compromising secure and safe transformer operation. A detailed background on the DSP differential current relay is provided. Then different DSP phasor estimation filters are implemented and evaluated based on their ability to extract desired frequency components from the measured current signal quickly and accurately. The main focus of the phasor estimation evaluation is to identify the difference between using non-recursive and recursive filtering methods. Then the protective logic of the DSP differential current relay is implemented and required settings made in accordance with transformer application. Finally, the DSP differential current relay will be evaluated using available transformer models within the ATP simulation environment. Recursive filtering methods were found to have significant advantage over non-recursive filtering methods when evaluated individually and when applied in the DSP differential relay. Recursive filtering methods can be up to 50% faster than non-recursive methods, but can cause false trip due to overshoot if the only objective is speed. The relay sensitivity is however independent of filtering method and depends on the settings of the relay’s differential characteristics (pickup threshold and percent slope).
Resumo:
An electrospray source has been developed using a novel new fluid that is both magnetic and conductive. Unlike conventional electrospray sources that required microfabricated structures to support the fluid to be electrosprayed, this new electrospray fluid utilizes the Rosensweig instability to create the structures in the magnetic fluid when an external magnetic field was applied. Application of an external electric field caused these magnetic fluid structures to spray. These fluid based structures were found to spray at a lower onset voltage than was predicted for electrospray sources with solid structures of similar geometry. These fluid based structures were also found to be resilient to damage, unlike the solid structures found in traditional electrospray sources. Further, experimental studies of magnetic fluids in non-uniform magnetic fields were conducted. The modes of Rosensweig instabilities have been studied in-depth when created by uniform magnetic fields, but little to no studies have been performed on Rosensweig instabilities formed due to non-uniform magnetic fields. The measured spacing of the cone-like structures of ferrofluid, in a non-uniform magnetic field, were found to agree with a proposed theoretical model.
Resumo:
Data of the strength of Earth’s magnetic field (paleointensity) in the geological past are crucial for understanding the geodynamo. Conventional paleointensity determination methods require heating a sample to a high temperature in one or more steps. Consequently, many rocks are unsuitable for these methods due to a heating-induced experimental alteration. Alternative non-heating paleointensity methods are investigated to assess their effectiveness and reliability using both natural samples from Lemptégy Volcano, France, and synthetic samples. Paleointensity was measured from the natural and synthetic samples using the Pseudo-Thellier, ARM, REM, REMc, REM’, and Preisach methods. For the natural samples, only the Pseudo-Thellier method was able to produce a reasonable paleointensity estimate consistent with previous paleointensity data. The synthetic samples yielded more successful estimates using all the methods, with the Pseudo-Thellier and ARM methods producing the most accurate results. The Pseudo-Thellier method appears to be the best alternative to the heating-based paleointensity methods.
Resumo:
Notwithstanding non-robotic, thoracoscopic preparation of the internal mammary artery (IMA) is a difficult surgical task, an appropriate experimental training model is lacking. We evaluated the young domestic pig for this purpose. Four domestic female pigs (30-40 kg body weight) were used for this study. Bilateral thoracoscopic preparation of the IMA was carried out under continuous, pressure controlled CO(2) insufflation. A 30 degrees rigid thoracoscope was inserted through a 10-mm port in the 5th/6th intercostal space (ICS) dorsally to the posterior axillary line. The dissection instrument (Ultracision Harmonic Scalpel) was inserted (5-mm port) in the 7th ICS at the posterior axillary line and the endo-forceps (5-mm port) in the 5th ICS at the posterior axillary line. Thoracoscopic IMA preparation in pig resulted more difficult than in man. A total of seven IMAs were prepared in their full intrathoracic length. A change in the preparation technique (lateral detachment of the endothoracic muscle) improved the safety of the procedure, allowing all four respective IMAs to be prepared safely, while the initial technique ensued an injury for 2 out of 3 vessels. The described young domestic pig model is suitable for experimental training of bilateral thoracoscopic IMA preparation.
Resumo:
Phagocytosis of fine particles (1 mum) by macrophages is a ligand-receptor-mediated, actin-based process, whereas the entering of smaller particles (= 0.2 mum) in macrophages occurs also by other mechanisms. Virosomes with a diameter of 0.12-0.18 mum are widely used as carrier systems for drugs, vectors, and plasmids in cancer therapy or for vaccines. We investigated their interactions with airway cells, in particular penetration into monocyte-derived macrophages. The microscopic analysis of phagocytic cells incubated with virosomes and polystyrene particles showed that virosomes and particles penetrated cells even in the presence of cytochalasin D, a drug inhibiting actin-based phagocytosis. The charge of the virosomes and particles did not influence their penetration. Also, different inhibitors of endocytotic pathways did not prevent the particles and virosomes from penetrating into the cells. Additionally, to study the ability of virosomes to overcome the epithelial airway barrier, a triple cell co-culture model composed of epithelial cells, monocyte-derived macrophages and dendritic cells of the respiratory tract was used. We found virosomes and polystyrene particles in both populations of antigen-presenting cells, monocyte-derived macrophages, and dendritic cells, in the latter even if they were not directly exposed. In conclusion, virosomes are readily taken up by monocyte-derived macrophages, both by conventional phagocytosis and by actin-independent mechanisms. Further, they can penetrate the airway barrier and reach resident dendritic cells. Therefore, virosomes are promising vaccine candidates.
Resumo:
BACKGROUND: A precise, non-invasive, non-toxic, repeatable, convenient and inexpensive follow-up of renal transplants, especially following biopsies, is in the interest of nephrologists. Formerly, the rate of biopsies leading to AV fistulas had been underestimated. Imaging procedures suited to a detailed judgement of these vascular malformations are to be assessed. METHODS: Three-dimensional (3D) reconstruction techniques of ultrasound flow-directed and non-flow-directed energy mode pictures were compared with a standard procedure, gadolinium-enhanced nuclear magnetic resonance imaging angiography (MRA) using the phase contrast technique. RESULTS: Using B-mode and conventional duplex information, AV fistulas were localized in the upper pole of the kidney transplant of the index patient. The 3D reconstruction provided information about the exact localization and orientation of the fistula in relation to other vascular structures, and the flow along the fistula. The MRA provided localization and orientation information, but less functional information. Flow-directed and non-flow-directed energy mode pictures could be reconstructed to provide 3D information about vascular malformations in transplanted kidneys. CONCLUSION: In transplanted kidneys, 3D-ultrasound angiography may be equally as effective as MRA in localizing and identifying AV malformations. Advantages of the ultrasound method are that it is cheaper, non-toxic, non-invasive, more widely availability and that it even provides more functional information. Future prospective studies will be necessary to evaluate the two techniques further.
Resumo:
BACKGROUND: We investigated the psychometric properties of a short questionnaire for combined assessment of different perceived stress management skills in the general population and tested whether scores relate to physiological stress reactivity. METHODS: For psychometric evaluation, we determined the factor structure of the questionnaire and investigated its measurement invariance in the participant groups and over time in three different independent samples representing the general population (total N=332). Reliability was tested by estimating test-retest reliability, internal consistency, and item reliabilities. We examined convergent and criterion validity using selected criterion variables. For endocrine validation, 35 healthy non-smoking and medication-free men in a laboratory study and 35 male and female employees in a workplace study underwent an acute standardized psychosocial stress task. We assessed stress management skills and measured salivary cortisol before and several times up to 60 min (workplace study) and 120 min (laboratory study) after stress. Potential confounders were controlled. RESULTS: The factor structure of the questionnaire consists of five scales reflecting acceptably distinct stress management skills such as cognitive strategies, use of social support, relaxation strategies, anger regulation, and perception of bodily tension. This factor structure was stable across participant groups and over time. Internal consistencies, item reliabilities, and test-retest reliabilities met established statistical requirements. Convergent and criterion validity were also established. In both endocrine validation studies, higher stress management skills were independently associated with lower cortisol stress reactivity (p's<.029). CONCLUSIONS: Our findings suggest that the questionnaire has good psychometric properties and that it relates to subjective psychological and objective physiological stress indicators. Therefore, the instrument seems a suitable measure for differential assessment of stress management skills in the general population.
Resumo:
STUDY QUESTION Is the steroid hormone profile in follicular fluid (FF) at the time of oocyte retrieval different in naturally matured follicles, as in natural cycle IVF (NC-IVF), compared with follicles stimulated with conventional gonadotrophin stimulated IVF (cIVF)? SUMMARY ANSWER Anti-Mullerian hormone (AMH), testosterone (T) and estradiol (E2) concentrations are ∼3-fold higher, androstenedione (A2) is ∼1.5-fold higher and luteinizing hormone (LH) is ∼14-fold higher in NC-IVF than in cIVF follicles, suggesting an alteration of the follicular metabolism in conventional gonadotrophin stimulated IVF. WHAT IS KNOWN ALREADY In conventional IVF, the implantation rate of unselected embryos appears to be lower than in NC-IVF, which is possibly due to negative effects of the stimulation regimen on follicular metabolism. In NC-IVF, the intrafollicular concentration of AMH has been shown to be positively correlated with the oocyte fertilization and implantation rates. Furthermore, androgen treatment seems to improve the ovarian response in low responders. STUDY DESIGN, SIZE, DURATION This cross-sectional study involving 36 NC-IVF and 40 cIVF cycles was performed from 2011 to 2013. Within this population, 13 women each underwent 1 NC-IVF and 1 cIVF cycle. cIVF was performed by controlled ovarian stimulation with HMG and GnRH antagonists. PARTICIPANTS/MATERIALS, SETTING, METHODS Follicular fluid was collected from the leading follicles. AMH, T, A2, dehydroepiandrosterone (DHEA), E2, FSH, LH and progesterone (P) were determined by immunoassays in 76 women. Aromatase activity in follicular fluid cells was analysed by a tritiated water release assay in 33 different women. For statistical analysis, the non-parametric Mann-Whitney U or Wilcoxon tests were used. MAIN RESULTS AND ROLE OF CHANCE In follicular fluid from NC-IVF and from cIVF, median levels were 32.8 and 10.7 pmol/l for AMH (P < 0.0001), 47.2 and 18.8 µmol/l for T (P < 0.0001), 290 and 206 nmol/l for A2 (P = 0.0035), 6.7 and 5.6 pg/ml for DHEA (n.s.), 3292 and 1225 nmol/l for E2 (P < 0.0001), 4.9 and 7.2 mU/ml for FSH (P < 0.05), 14.4 and 0.9 mU/ml for LH (P < 0.0001) and 62 940 and 54 710 nmol/l for P (n.s.), respectively. Significant differences in follicular fluid concentrations for AMH, E2 and LH were also found in the 13 patients who underwent both NC-IVF and cIVF when they were analysed separately in pairs. Hormone analysis in serum excluded any relevant impact of AMH, T, A2, and E2 serum concentration on the follicular fluid hormone concentrations. Median serum concentrations were 29.4 and 0.9 mU/ml for LH (P < 0.0001) and 2.7 and 23.5 nmol/l for P (P < 0.0001) after NC-IVF and c-IVF, respectively. Positive correlations were seen for FF-AMH with FF-T (r = 0.35, P = 0.0002), FF-T with FF-LH (r = 0.48, P < 0.0001) and FF-E2 with FF-T (r = 0.75, P < 0.0001). The analysis of aromatase activity was not different in NC-IVF and cIVF follicular cells. LIMITATION, REASONS FOR CAUTION Any association between the hormone concentrations and the implantation potential of the oocytes could not be investigated as the oocytes in cIVF were not treated individually in the IVF laboratory. Since both c-IVF and NC-IVF follicles were stimulated by hCG before retrieval, the endocrine milieu in the natural cycle does not represent the pure physiological situation. WIDER IMPLICATIONS OF THE FINDINGS The endocrine follicular milieu and the concentration of putative markers of oocyte quality, such as AMH, are significantly different in gonadotrophin-stimulated conventional IVF compared with natural cycle IVF. This could be a cause for the suggested lower oocyte quality in cIVF compared with naturally matured oocytes. The reasons for the reduced AMH concentration might be low serum and follicular fluid LH concentrations due to LH suppression, leading initially to low follicular androgen concentrations and then to low follicular AMH production. STUDY FUNDING/COMPETING INTERESTS Funding for this study was obtained from public universities (for salaries) and private industry (for consumables). Additionally, the study was supported by an unrestricted grant from MSD Merck Sharp & Dohme GmbH and IBSA Institut Biochimique SA. The authors are clinically involved in low-dose monofollicular stimulation and IVF therapies, using gonadotrophins from all gonadotrophin distributors on the Swiss market, including Institut Biochimique SA and MSD Merck Sharp & Dohme GmbH. Otherwise, the authors have no competing interests. TRIAL REGISTRATION NUMBER Not applicable.
Resumo:
AIM To investigate age- and gender-related differences in non-culprit versus culprit coronary vessels assessed with virtual histology intravascular ultrasound (VH-IVUS). METHODS In 390 patients referred for coronary angiography to a single center (Luzerner Kantonsspital, Switzerland) between May 2007 and January 2011, 691 proximal vessel segments in left anterior descending, circumflex and/or right coronary arteries were imaged by VH-IVUS. Plaque burden and plaque composition (fibrous, fibro-fatty, necrotic core and dense calcium volumes) were analyzed in 3 age tertiles, according to gender and separated for vessels containing non-culprit or culprit lesions. To classify as vessel containing a culprit lesion, the patient had to present with an acute coronary syndrome, and the VH-IVUS had to be performed in a vessel segment containing the culprit lesion according to conventional coronary angiography. RESULTS In non-culprit vessels the plaque burden increased significantly with aging (in men from 37% ± 12% in the lowest to 46% ± 10% in the highest age tertile, P < 0.001; in women from 30% ± 9% to 40% ± 11%, P < 0.001); men had higher plaque burden than women at any age (P < 0.001 for each of the 3 age tertiles). In culprit vessels of the lowest age tertile, plaque burden was significantly higher than that in non-culprit vessels (in men 48% ± 6%, P < 0.001 as compared to non-culprit vessels; in women 44% ± 18%, P = 0.004 as compared to non-culprit vessels). Plaque burden of culprit vessels did not significantly change during aging (plaque burden in men of the highest age tertile 51% ± 9%, P = 0.523 as compared to lowest age tertile; in women of the highest age tertile 49% ± 8%, P = 0.449 as compared to lowest age tertile). In men, plaque morphology of culprit vessels became increasingly rupture-prone during aging (increasing percentages of necrotic core and dense calcium), whereas plaque morphology in non-culprit vessels was less rupture-prone and remained constant during aging. In women, necrotic core in non-culprit vessels was very low at young age, but increased during aging resulting in a plaque morphology that was very similar to men. Plaque morphology in culprit vessels of young women and men was similar. CONCLUSION This study provides evidence that age- and gender-related differences in plaque burden and plaque composition significantly depend on whether the vessel contained a non-culprit or culprit lesion.
Resumo:
BACKGROUND Nebulized surfactant therapy has been proposed as an alternative method of surfactant administration. The use of a perforated vibrating membrane nebulizer provides a variety of advantages over conventional nebulizers. We investigated the molecular structure and integrity of poractant alfa pre- and post-nebulization. METHOD Curosurf® was nebulized using an Investigational eFlow® Nebulizer System. Non-nebulized surfactant ("NN"), recollected surfactant droplets from nebulization through an endotracheal tube ("NT") and nebulization of surfactant directly onto a surface ("ND") were investigated by transmission electron microscopy. Biophysical characteristics were assessed by the Langmuir-Wilhelmy balance and the Captive Bubble Surfactometer. RESULTS Volume densities of lamellar body-like forms (LBL) and multi-lamellar forms (ML) were high for "NN" and "NT" samples (38.8% vs. 47.7% for LBL and 58.2% vs. 47.8% for ML). In the "ND" sample, we found virtually no LBL's, ML's (72.6%) as well as uni-lamellar forms (16.4%) and a new structure, the "garland-like" forms (9.4%). Surface tension for "NN" and "NT" was 23.33 ± 0.29 and 25.77 ± 1.12 mN/m, respectively. Dynamic compression-expansion cycling minimum surface tensions were between 0.91 and 1.77 mN/m. CONCLUSION The similarity of surfactant characteristics of nebulized surfactant via a tube and the non-nebulized surfactant suggests that vibrating membrane nebulizers are suitable for surfactant nebulization. Alterations in surfactant morphology and characteristics after nebulization were transient. A new structural subtype of surfactant was identified. Pediatr Pulmonol. 2014; 49:348-356. © 2013 Wiley Periodicals, Inc.
Resumo:
Motivated by the reported dearth of debris discs around M stars, we use survival models to study the occurrence of planetesimal discs around them. These survival models describe a planetesimal disc with a small number of parameters, determine if it may survive a series of dynamical processes and compute the associated infrared excess. For the Wide-field Infrared Survey Explorer (WISE) satellite, we demonstrate that the dearth of debris discs around M stars may be attributed to the small semimajor axes generally probed if either: (1) the dust grains behave like blackbodies emitting at a peak wavelength coincident with the observed one; (2) or the grains are hotter than predicted by their blackbody temperatures and emit at peak wavelengths that are shorter than the observed one. At these small distances from the M star, planetesimals are unlikely to survive or persist for time-scales of 300 Myr or longer if the disc is too massive. Conversely, our survival models allow for the existence of a large population of low-mass debris discs that are too faint to be detected with current instruments. We gain further confidence in our interpretation by demonstrating the ability to compute infrared excesses for Sun-like stars that are broadly consistent with reported values in the literature. However, our interpretation becomes less clear and large infrared excesses are allowed if only one of these scenarios holds: (3) the dust grains are hotter than blackbody and predominantly emit at the observed wavelength; (4) or are blackbody in nature and emit at peak wavelengths longer than the observed one. Both scenarios imply that the parent planetesimals reside at larger distances from the star than inferred if the dust grains behaved like blackbodies. In all scenarios, we show that the infrared excesses detected at 22 μm (via WISE) and 70 μm (via Spitzer) from AU Mic are easily reconciled with its young age (12 Myr). Conversely, the existence of the old debris disc (2–8 Gyr) from GJ 581 is due to the large semimajor axes probed by the Herschel PACS instrument. We elucidate the conditions under which stellar wind drag may be neglected when considering dust populations around M stars. The WISE satellite should be capable of detecting debris discs around young M stars with ages ∼10 Myr.
Resumo:
BACKGROUND/AIMS Clinical differentiation between organic hypersomnia and non-organic hypersomnia (NOH) is challenging. We aimed to determine the diagnostic value of sleepiness and performance tests in patients with excessive daytime sleepiness (EDS) of organic and non-organic origin. METHODS We conducted a retrospective comparison of the multiple sleep latency test (MSLT), pupillography, and the Steer Clear performance test in three patient groups complaining of EDS: 19 patients with NOH, 23 patients with narcolepsy (NAR), and 46 patients with mild to moderate obstructive sleep apnoea syndrome (OSAS). RESULTS As required by the inclusion criteria, all patients had Epworth Sleepiness Scale (ESS) scores >10. The mean sleep latency in the MSLT indicated mild objective sleepiness in NOH (8.1 ± 4.0 min) and OSAS (7.2 ± 4.1 min), but more severe sleepiness in NAR (2.5 ± 2.0 min). The difference between NAR and the other two groups was significant; the difference between NOH and OSAS was not. In the Steer Clear performance test, NOH patients performed worst (error rate = 10.4%) followed by NAR (8.0%) and OSAS patients (5.9%; p = 0.008). The difference between OSAS and the other two groups was significant, but not between NOH and NAR. The pupillary unrest index was found to be highest in NAR (11.5) followed by NOH (9.2) and OSAS (7.4; n.s.). CONCLUSION A high error rate in the Steer Clear performance test along with mild sleepiness in an objective sleepiness test (MSLT) in a patient with subjective sleepiness (ESS) is suggestive of NOH. This disproportionately high error rate in NOH may be caused by factors unrelated to sleep pressure, such as anergia, reduced attention and motivation affecting performance, but not conventional sleepiness measurements.
Resumo:
BACKGROUND The assessment of hemodynamic status is a crucial task in the initial evaluation of trauma patients. However, blood pressure and heart rate are often misleading, as multiple variables may impact these conventional parameters. More reliable methods such as pulmonary artery thermodilution for cardiac output measuring would be necessary, but its applicability in the Emergency Department is questionable due to their invasive nature. Non-invasive cardiac output monitoring devices may be a feasible alternative. METHODS A systematic literature review was conducted. Only studies that explicitly investigated non-invasive hemodynamic monitoring devices in trauma patients were considered. RESULTS A total of 7 studies were identified as suitable and were included into this review. These studies evaluated in a total of 1,197 trauma patients the accuracy of non-invasive hemodynamic monitoring devices by comparing measurements to pulmonary artery thermodilution, which is the gold standard for cardiac output measuring. The correlation coefficients r between the two methods ranged from 0.79 to 0.92. Bias and precision analysis ranged from -0.02 +/- 0.78 l/min/m(2) to -0.14 +/- 0.73 l/min/m(2). Additionally, data on practicality, limitations and clinical impact of the devices were collected. CONCLUSION The accuracy of non-invasive cardiac output monitoring devices in trauma patients is broadly satisfactory. As the devices can be applied very early in the shock room or even preclinically, hemodynamic shock may be recognized much earlier and therapeutic interventions could be applied more rapidly and more adequately. The devices can be used in the daily routine of a busy ED, as they are non-invasive and easy to master.
Resumo:
Recent findings demonstrate that trees in deserts are efficient carbon sinks. It remains however unknown whether the Clean Development Mechanism will accelerate the planting of trees in Non Annex I dryland countries. We estimated the price of carbon at which a farmer would be indifferent between his customary activity and the planting of trees to trade carbon credits, along an aridity gradient. Carbon yields were simulated by means of the CO2FIX v3.1 model for Pinus halepensis with its respective yield classes along the gradient (Arid – 100mm to Dry Sub Humid conditions – 900mm). Wheat and pasture yields were predicted on somewhat similar nitrogen-based quadratic models, using 30 years of weather data to simulate moisture stress. Stochastic production, input and output prices were afterwards simulated on a Monte Carlo matrix. Results show that, despite the high levels of carbon uptake, carbon trading by afforesting is unprofitable anywhere along the gradient. Indeed, the price of carbon would have to raise unrealistically high, and the certification costs would have to drop significantly, to make the Clean Development Mechanism worthwhile for non annex I dryland countries farmers. From a government agency's point of view the Clean Development Mechanism is attractive. However, such agencies will find it difficult to demonstrate “additionality”, even if the rule may be somewhat flexible. Based on these findings, we will further discuss why the Clean Development Mechanism, a supposedly pro-poor instrument, fails to assist farmers in Non Annex I dryland countries living at minimum subsistence level.
Resumo:
Antibody-drug conjugates (ADCs) have emerged as a promising class of anticancer agents, combining the specificity of antibodies for tumor targeting and the destructive potential of highly potent drugs as payload. An essential component of these immunoconjugates is a bifunctional linker capable of reacting with the antibody and the payload to assemble a functional entity. Linker design is fundamental, as it must provide high stability in the circulation to prevent premature drug release, but be capable of releasing the active drug inside the target cell upon receptor-mediated endocytosis. Although ADCs have demonstrated an increased therapeutic window, compared to conventional chemotherapy in recent clinical trials, therapeutic success rates are still far from optimal. To explore other regimes of half-life variation and drug conjugation stoichiometries, it is necessary to investigate additional binding proteins which offer access to a wide range of formats, all with molecularly defined drug conjugation. Here, we delineate recent progress with site-specific and biorthogonal conjugation chemistries, and discuss alternative, biophysically more stable protein scaffolds like Designed Ankyrin Repeat Proteins (DARPins), which may provide such additional engineering opportunities for drug conjugates with improved pharmacological performance.