1000 resultados para laser threshold


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zn1−xCoxO films with different Co concentrations (with x=0.00, 0.10, 0.15, and 0.30) were grown by pulsed laser deposition (PLD) technique. The structural and optical properties of the films were investigated by grazing incidence X-ray diffraction (GIXRD), Raman spectroscopy and photoluminescence (PL). The magnetic properties were measured by conventional magnetometry using a SQUID and simulated by ab-initio calculations using Korring–Khon–Rostoker (KKR) method combined with coherent potential approximation (CPA). The effect of Co-doping on the GIXRD and Raman peaks positions, shape and intensity is discussed. PL studies demonstrate that Co-doping induces a decrease of the bandgap energy and quenching of the UV emission. They also suggest the presence of Zn interstitials when x≥0.15. The 10% Co-doped ZnO film shows ferromagnetism at 390 K with a spontaneous magnetic moment ≈4×10−5 emu and coercive field ≈0.17 kOe. The origin of ferromagnetism is explained based on the calculations using KKR method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, Ba0.8Sr0.2TiO3 (BST)/ITO structures were grown on glass substrate and laser assisted annealing (LAA) was performed to promote the crystallization of BST. Atomic force microscopy and X-ray diffraction studies confirm the crack free and polycrystalline perovskite phase of BST. White light controlled resistive switching (RS) effect in Au/BST/ITO device is investigated. The device displays the electroforming-free bipolar RS characteristics and are explained by the modulationof the width and height of barrier at the BST/ITO interface via ferroelectric polarization. Moreover, the RS effect is signifi- cantly improved under white light illumination compared to that in the dark. The enhanced RS and photovoltaic effects are explained by considering depolarization field and charge distribution at the interface. The devices exhibit stable retention characteristics with low currents (mA), which make them attractive for non volatile memory devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Engenharia Clínica)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the initial clinical experience of transmyocardial laser revascularization (TMLR) in patients with severe diffuse coronary artery disease. METHODS: Between February, 1998 and February, 1999, 20 patients were submitted to TMLR at the Heart Institute (InCor), University of São Paulo Medical School, Brazil, isolated or in association with conventional coronary artery bypass graft (CABG). All patients had severe diffuse coronary artery disease, with angina functional class III/IV (Canadian Cardiovascular Society score) unresponsive to medical therapy. Fourteen patients were submitted to TMLR as the sole therapy, whereas 6 underwent concomitant CABG. Fifty per cent of the patients had either been previously submitted to a CABG or to a percutaneous transluminal coronary angioplasty (PTCA). Mean age was 60 years, ranging from 45 to 74 years. RESULTS: All patients had three-vessel disease, with normal or mildly impaired left ventricular global function. Follow-up ranged from 1 to 13 months (mean 6.6 months), with no postoperative short or long term mortality. There was significant symptom improvement after the procedure, with 85% of the patients free of angina, and the remaining 15 % of the patients showing improvement in functional class, as well as in exercise tolerance. CONCLUSION: This novel technique can be considered a low risk alternative for a highly selected group of patients not suitable for conventional revascularization procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVE: With the increased use of intracoronary stents, in-stent restenosis has become a clinically significant drawback in invasive cardiology. We retrospectively assessed the short- and long-term outcomes after excimer laser coronary angioplasty of in-stent restenosis. METHODS: Twenty-five patients with 33 incidents of in-stent restenosis treated with excimer laser coronary angioplasty (ELCA) were analyzed. Sixty-six percent were males, mean age of 73±11 years, and 83% were functional class III-IV (NYHA). ELCA was performed using 23 concentric and 10 eccentric catheters with a diameter of 1.6-2.2 mm, followed by balloon angioplasty (PTCA) and ultrasound monitoring. The procedure was performed in the following vessels: left anterior descending artery, 10; left circumflex artery, 8; right coronary artery, 6; left main coronary artery, 2; and venous bypass graft, 7. RESULTS: The ELCA was successful in 71% of the cases, and PTCA was 100% successful. The diameter of the treated vessels was 3.44±0.5mm; the minimal luminal diameter (MLD) increased from 0.30mm pre-ECLA to 1.97mm post-ELCA, and to 2.94mm post-PTCA (p<0.001). The percent stenosis was reduced from 91.4±9.5% before ECLA to 42.3±14.9% after ELCA and to 14.6 ± 9.3% after PTCA (p<0.001). Seventeen (68%) patients were asymptomatic at 6 months and 15 (60%) at 1 year. New restenosis rates were 8/33 (24.2%) at 6 months and 9 /33 (27.3%) at 12 months. CONCLUSION: ELCA is safe and effective for the treatment of in-stent restenosis. In the present sample, a slight increase in new restenotic lesions between 6 and 12 months was found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE - To identify, the anaerobic threshold and respiratory compensation point in patients with heart failure. METHODS - The study comprised 42 Men,divided according to the functional class (FC) as follows: group I (GI) - 15 patients in FC I; group II (GII) - 15 patients in FC II; and group III (GIII) - 12 patients in FC III. Patients underwent a treadmill cardiopulmonary exercise test, where the expired gases were analyzed. RESULTS - The values for the heart rate (in bpm) at the anaerobic threshold were the following: GI, 122±27; GII, 117±17; GIII, 114±22. At the respiratory compensation point, the heart rates (in bpm) were as follows: GI, 145±33; GII, 133±14; GIII 123±22. The values for the heart rates at the respiratory compensation point in GI and GIII showed statistical difference. The values of oxygen consumption (VO2) at the anaerobic threshold were the following (in ml/kg/min): GI, 13.6±3.25; GII, 10.77±1.89; GIII, 8.7±1.44 and, at the respiratory compensation point, they were as follows: GI, 19.1±2.2; GII, 14.22±2.63; GIII, 10.27±1.85. CONCLUSION - Patients with stable functional class I, II, and III heart failure reached the anaerobic threshold and the respiratory compensation point at different levels of oxygen consumption and heart rate. The role played by these thresholds in physical activity for this group of patients needs to be better clarified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the results of laser-assisted extraction of permanent pacemaker and defibrillator leads. METHODS: We operated upon 36 patients, whose mean age was 54.2 years, and extracted 56 leads. The reasons for extracting the leads were as follows: infection in 19 patients, elective replacement in 13, and other causes in 4 patients. The mean time of catheter placement was 7.5±5.5 years. Forty-seven leads were from pacemakers, and 9 were from defibrillators. Thirty-eight leads were in use, 14 had been abandoned in the pacemaker pocket, and 4 had been abandoned inside the venous system. RESULTS: We successfully extracted 54 catheters, obtaining a 96.4% rate of success and an 82.1% rate for complete extraction. The 2 unsuccessful cases were due to the presence of calcium in the trajectory of the lead. The mean duration of laser light application was 123.0±104.5 s, using 5,215.2±4,924.0 pulses, in a total of 24.4±24.2 cycles of application. Thirty-four leads were extracted from the myocardium with countertraction after complete progression of the laser sheath, 12 leads came loose during the progression of the laser sheath, and the remaining 10 were extracted with other maneuvers. One patient experienced cardiac tamponade after extraction of the defibrillator lead, requiring open emergency surgery. CONCLUSION: The use of the excimer laser allowed extraction of the leads with a 96% rate of success; it was not effective in 2 patients who had calcification on the lead. One patient (2.8%) had a complication that required cardiac surgery on an emergency basis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El láser de baja y media energía y la magnetoterapia son utilizados en desórdenes osteomioarticulares por sus efectos analgésico, antiinflamatorio y trófico, entre los más destacados. Sin embargo, son insuficientes las investigaciones sobre su mecanismo de acción y antecedentes científicos que avalen sus efectos. Es por ello, que la determinación de acontecimientos celulares y moleculares que ocurren durante la interacción de estos tipos de energía con el sistema muscular, sería relevante para el conocimiento y optimización de tales terapias en las ciencias biomédicas. En las miopatías inflamatorias idiopáticas, se encuentra afectada la estructura, morfología y bioquímica del tejido muscular. La energía que éste requiere para el normal funcionamiento es generada en la mitocondria. Esta organela también es la responsable de la generación de especies oxidantes provocando estrés oxidativo y el inicio de los procesos de apoptosis. Por lo antes dicho, consideramos que la determinación de los biomarcadores inflamatorios asociados a estrés oxidativo, realizando el análisis histomorfométrico ultraestructural y valorando la actividad de los complejos enzimáticos mitocondriales, permitiría una evaluación de la acción terapéutica del láser y la magnetoterapia en un modelo experimental de miopatía. Para ello se propone evaluar el efecto de la magnetoterapia y del láser de baja energía (He-Ne y As.Ga) en miopatía experimental determinando indicadores inflamatorios asociados a estrés oxidativo, análisis histomorfométrico y valoración de la actividad enzimática mitocondrial. Específicamente: -Determinar indicadores inflamatorios y de estrés oxidativo: Oxido Nítrico, Grupos carbonilos, L-citrulina, Fibrinógeno, Superóxido dismutasa, Glutation peroxidasa y Catalasa por espectrofotometría. -Identificar los cambios anatomopatológicos del músculo esquelético por microscopía óptica (MO): cuantificación del infiltrado inflamatorio; MO de alta resolución (MOAR) y por microscopía electrónica: histomorfometría de la ultraestructura miofibrilar y mitocondrial. -Valorar las actividades enzimáticas de la citrato sintasa y de los complejos: I (NADH-ubiquinona reductasa), II (succinato-ubiquinona-reductasa) III (ubiquinona-citocromo c-reductasa) y IV (citocromo c-oxidasa); en mitocondrias de tejido muscular por espectrofotometría. -Evaluar la actividad apoptótica en las fibras musculares de los diferentes grupos por ténica de T.U.N.E.L. Las mediciones mitocondriales (por ME) y de infiltrado inflamatorio (por MO) se realizarán en un total de 5 fotos de aumentos similares en forma aleatoria por grupo estudiado (n=10). Los cambios estructurales observados se analizarán en el programa Axiovision 4.8, para cuantificar el área total ocupada, número total y grado de alteración de las mitocondrias y el porcentaje de infiltrado inflamatorio determinando el grado de inflamación. Los resultados de los datos cuantitativos se analizarán aplicando ANAVA (test de Fisher para comparaciones múltiples); y para los datos categóricos se utilizará Chi cuadrado (test de Pearson), estableciéndose un nivel de significación de p < 0.05 para todos los casos. Importancia del Proyecto: La salud y el bienestar del hombre son los logros perseguidos por las ciencias de la salud. La obtención de terapias curativas o paliativas con un mínimo de efectos colaterales para el enfermo se incluye en estos logros. Por esto y todo lo anteriormente expuesto es que consideramos de gran importancia poder esclarecer desde las ciencias básicas los efectos celulares y moleculares en modelos experimentales la acción de la terapia con láser y magnetoterapia para una aplicación clínica con base científica en todas las áreas de las Ciencias Médicas. In the idiopathic inflammatory myopathies, is affected the structure, morphology and biochemistry of muscle tissue. The mitochondria is responsible for the generation of oxidizing species leading to oxidative stress and the beginning of the process of apoptosis. As said before, we consider the determination of inflammatory biomarkers related to oxidative stress, by ultrastructural morphometric analysis and assessing the activity of mitochondrial enzyme complexes, permit an evaluation of the therapeutic action of laser and magnetic therapy in an experimental model myopathy. We propose to evaluate the effect of the treatment identifying indicators in experimental inflammatory myopathy associated with oxidative stress, histomorphometric analysis and assessment of mitochondrial enzyme activity. Specifically -determining: Nitric oxide, carbonyl groups, L-citrulline, fibrinogen, superoxide dismutase, glutathione peroxidase and catalase by spectrophotometry. -Identify the pathological changes in skeletal muscle by optical microscopy (OM): quantification of the inflammatory infiltrate, OM high resolution (MOAR) and electron microscopy, histomorphometry of myofibrillar and mitochondrial ultrastructure. -Evaluate the enzymatic activity of citrate synthase and complexes: I, II, III and IV in mitochondria muscle tissue by spectrophotometry. -Evaluate apoptotic activity in muscle fibers by TUNEL technique of Mitochondrial measurements and inflammatory infiltration (by OM) was performed in a total of 5 photos of similar increases in random by the study group (n = 10). The structural changes observed are discussed in the program Axiovision 4.8, to quantify number, degree of alteration of mitochondria and the percentage of inflammatory infiltrate determining the degree of inflammation. The results of the quantitative data were analyzed using ANOVA (Fisher test), and categorical data with Chi-square (Pearson test), establishing a significance level of p <0.05.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FUNDAMENTO: O isolamento das veias pulmonares (IVP) tem sido usado como endpoint para a ablação da fibrilação atrial (FA) com cateter balão. OBJETIVO: Determinar a utilidade do ultrassom intracardíaco (USIC) para guiar o IVP, usando cateter balão a laser. MÉTODOS: 59 VP foram ablacionadas em 27 cães. Imagens de Doppler foram usadas para identificar os vazamentos do fluxo sanguíneo entre a VP e o balão. Após cada liberação de energia, o cateter de mapeamento circular foi reposicionado para verificar se o isolamento tinha sido obtido. A posição de vazamento foi então correlacionada com a posição do gap no estudo patológico. A análise de regressão logística multivariada foi realizada. RESULTADOS: Cinquenta e nove VP foram submetidas à ablação. O tempo médio de energia liberada foi de 279±177 seg., o diâmetro médio do balão era de 23±3 mm, e o comprimento médio do balão era 25±4 mm. O isolamento completo foi obtido em 38/59 (64%), e foi significantemente mais comum sem vazamento: [30/38 (79%) versus 8/23 (35%), p<0,001]. Isso foi independente do tempo de aplicação (302±223 seg. vs. 266±148 sec., p=ns), potência (3,5 W/cm, 4,5 W/cm, e 5,5 W/cm), diâmetro do balão (24± 3 mm vs. 22± 3 mm, p= ns) e comprimento (27±4 mm vs. 24±4 mm, p=ns). O valor preditivo positivo para previsão de isolamento completo foi de 65% e o valor preditivo negativo foi 83%. CONCLUSÃO: Um vazamento identificável entre a VP e o dispositivo de ablação por cateter-balão observado no USIC é preditor de menor taxa de isolamento de VP mais baixas. O USIC pode ser útil para detectar vazamentos a fim de evitar o uso ineficaz de aplicação energia durante a ablação circunferencial da VP. Isto também pode ser útil quando outras energias são utilizadas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Systemic arterial hypertension (SAH) is considered to be the greatest risk factor for the development of neuro-cardiovascular pathologies, thus constituting a severe Public Health issue in the world. The Low-Level Laser Therapy (LLLT), or laser therapy, activates components of the cellular structure, therefore converting luminous energy into photochemical energy and leading to biophysical and biochemical reactions in the mitochondrial respiratory chain. The LLLT promotes cellular and tissue photobiomodulation by means of changes in metabolism, leading to molecular, cellular and systemic changes. The objective of this study was to analyze the action of low-level laser in the hemodynamic modulation of spontaneously hypertensive rats, in the long term. Animals (n = 16) were randomly divided into the Laser Group (n = 8), which received three weekly LLLT irradiations for seven weeks, and into the Sham Group (n = 8), which received three weekly simulations of laser for seven weeks, accounting for 21 applications in each group. After seven weeks, animals were cannulated by the implantation of a catheter in the left carotid artery. On the following day, the systemic arterial pressure was recorded. The Laser Group showed reduced levels of mean blood pressure, with statistically significant reduction (169 ± 4 mmHg* vs. 182 ± 4 mmHg from the Sham Group) and reduced levels of diastolic pressure (143 ± 4 mmHg* vs. 157 ± 3 mmHg from the Sham Group), revealing a 13 and 14 mmHg decrease, respectively. Besides, there was a concomitant important decline in heart rate (312 ± 14 bpm vs. 361 ± 13 bpm from the Sham Group). Therefore, laser therapy was able to produce hemodynamic changes, thus reducing pressure levels in spontaneously hypertensive rats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Data from over 4 decades have reported a higher incidence of silent infarction among patients with diabetes mellitus (DM), but recent publications have shown conflicting results regarding the correlation between DM and presence of pain in patients with acute coronary syndromes (ACS). Objective: Our primary objective was to analyze the association between DM and precordial pain at hospital arrival. Secondary analyses evaluated the association between hyperglycemia and precordial pain at presentation, and the subgroup of patients presenting within 6 hours of symptom onset. Methods: We analyzed a prospectively designed registry of 3,544 patients with ACS admitted to a Coronary Care Unit of a tertiary hospital. We developed multivariable models to adjust for potential confounders. Results: Patients with precordial pain were less likely to have DM (30.3%) than those without pain (34.0%; unadjusted p = 0.029), but this difference was not significant after multivariable adjustment, for the global population (p = 0.84), and for subset of patients that presented within 6 hours from symptom onset (p = 0.51). In contrast, precordial pain was more likely among patients with hyperglycemia (41.2% vs 37.0% without hyperglycemia, p = 0.035) in the overall population and also among those who presented within 6 hours (41.6% vs. 32.3%, p = 0.001). Adjusted models showed an independent association between hyperglycemia and pain at presentation, especially among patients who presented within 6 hours (OR = 1.41, p = 0.008). Conclusion: In this non-selected ACS population, there was no correlation between DM and hospital presentation without precordial pain. Moreover, hyperglycemia correlated significantly with pain at presentation, especially in the population that arrived within 6 hours from symptom onset.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudi elaborat a partir d’una estada al Stony Brook University al juliol del 2006. El RbTiOPO4 (RTP) monocristal•lí és un material d' òptica no lineal molt rellevant i utilitzat en la tecnologia làser actual, químicament molt estable i amb unes propietats físiques molt destacades, entre elles destaquen els alts coeficients electro-òptics i l'alt llindar de dany òptic que presenta. En els últims anys s’està utilitzant tecnològicament en aplicacions d'òptica no lineal en general i electro-òptiques en particular. En alguns casos ja ha substituït, millorant prestacions, a materials tals com el KTP o el LNB(1). Dopant RTP amb ions lantànids (Ln3+) (2-4), el material es converteix en un material làser auto-doblador de freqüència, combinant les seves propietats no lineals amb les de matriu làser. El RTP genera radiació de segon harmònic (SHG) a partir d’un feix fonamental amb longituds d’ona inferiors a 990 nm, que és el límit que presenta el KTP.La determinació de la ubicació estructural i l’estudi de l'entorn local del ions actius làser és de fonamental importància per a la correcta interpretació de les propietats espectroscòpiques d’aquest material. Mesures de difracció de neutrons sobre mostra de pols cristal•lí mostren que els ions Nb5+ i Ln3+ només substitueixin posicions de Ti4+ (8-9). Estudis molt recents d'EPR (electron paramagnetic resonance) semblen indicar que quan la concentració d'ió Ln3+ es baixa, aquest ió presenta la tendència a substituir l'ió alcalí present a l'estructura (10).Després dels resultats obtinguts en el present treball a partir de la tècnica EXAFS a la instal•lació sincrotò del Brookhaven National Laboratory/State University of New York (Stony Brook) es pot concloure definitivament que els ions Nb s’ubiquen en la posició Ti (1) i que els ions Yb3+ es distribueixen paritariament en les dues posicions del Ti (1 i 2). Aquests resultats aporten una valuosa informació per a la correcta interpretació dels espectres, tant d’absorció com d’emissió, del material i per la avaluació dels paràmetres del seu comportament durant l'acció làser.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudio elaborado a partir de una estancia en la Universidad de Rochester, Estados Unidos, de octubre del 2006 a enero del 2007. La estancia realizada en la Universidad de Rochester estuvo orientada al aprendizaje en profundidad del oftalmoscopio láser de barrido. El oftalmoscopio láser de barrido emplea una técnica confocal con la finalidad de visualizar diferentes estructuras retinianas en seres vivos. El instrumento diseñado y desarrollado en el Centro de Ciencias de la Visión incorpora un sistema de óptica adaptativa y fluorescencia. La óptica adaptativa aplicada en este oftalmoscopio tiene como objetivo corregir las aberraciones existentes en el ojo y así permitir observar detalles de la retina que de otra forma se verían emborronados. De esta forma se consigue alcanzar valores de resolución muy cercanos a los impuestos por difracción. Por otro lado el uso de fluorescencia tiene por objetivo el permitir la visualización de células y estructuras que, de no ser teñidas, son transparentes a la luz y visible. Esta técnica se ha estado utilizando principalmente en primates y ratas, aunque actualmente también se están llevando a cabo medidas de células de epitelio pigmentario en seres humanos ya que el pigmento contenido en estas células permite la aplicación de la fluorescencia sin necesidad de utilizar tinción.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We use a threshold seemingly unrelated regressions specification to assess whether the Central and East European countries (CEECs) are synchronized in their business cycles to the Euro-area. This specification is useful in two ways: First, it takes into account the common institutional factors and the similarities across CEECs in their process of economic transition. Second, it captures business cycle asymmetries by allowing for the presence of two distinct regimes for the CEECs. As the CEECs are strongly affected by the Euro-area these regimes may be associated with Euro-area expansions and contractions. We discuss representation, estimation by maximum likelihood and inference. The methodology is illustrated by using monthly industrial production in 8 CEECs. The results show that apart from Lithuania the rest of the CEECs experience “normal” growth when the Euro-area contracts and “high” growth when the Euro-area expands. Given that the CEECs are “catching up” with the Euro-area this result shows that most CEECs seem synchronized to the Euro-area cycle. Keywords: Threshold SURE; asymmetry; business cycles; CEECs. JEL classification: C33; C50; E32.