953 resultados para interpersonal reproducibility
Resumo:
Background and Aims. HTLV-I-transformed T cells secrete biologically active forms of vascular endothelial growth factor (VEGF) and basic fibroblast growth factor (b-FGF). In addition, HTLV-I-transformed cells have a high capacity of adhesion to endothelial cells. Methods. We measured the circulating endothelial progenitor cells (EPCs) and mature endothelial cells (MECs) by flow cytometry in 27 HTLV-I carriers in comparison to 30 healthy, age- and gender-matched subjects. All subjects had HTLV-I positivity confirmed by Western blot and/or polymerase chain reaction (PCR). The numbers of different subpopulations of EPCs and MECSs were evaluated by four-color flow cytometry using a panel of monoclonal antibodies. All reactions were done in duplicate to confirm reproducibility of the results. Results. The median age of all 27 HTLV-I carriers enrolled in this study was 45 years (range: 27-65 years); 11(41%) were male and 16 (59%) were female. The median age of the 30 healthy subjects in the control group was 45.5 years (range: 20-63 years); 11 (36.6%) were male and 19 (63.4%) were female. The number of EPCs was significantly higher in HTLV-I carriers (median 0.8288 cells/mu L, range: 0.0920-3.3176 cells/mu L) as compared to control group (median 0.4905 cells/mu L, range: 0.0000-1.5660 cells/mu L) (p = 0.035). In contrast, the median of the MECs in the HTLV-I carriers was 0.6380 cells/mu L (range: 0.0473-5.7618 cells/mu L) and 0.4950 cells/mu L (range: 0.0000-4.0896 cells/mu L) in the control group, with no statistical difference (p = 0.697). Conclusions. We demonstrated that EPCs, but not MECs, are increased in the peripheral blood of HTLV-I carriers. (C) 2011 IMSS. Published by Elsevier Inc.
Resumo:
Dacryocystorhinostomy is the treatment of choice for the obstruction of the lachrymal apparatus. At the end of last century, the development of the endoscopic instruments for nasosinusal surgery has made it possible to do it through the endoscopic pathway. Nonetheless, anatomical variations make it difficult to have reproducibility endonasaly. Aim: study the endoscopic anatomy of the lachrymal fossa through transillumination of the common canaliculus. Study design: experimental. Materials and Methods: we dissected 40 lachrymal pathways from 20 human cadavers, in three stages: 1. identification and dilation of the lachrymal canaliculus. 2 Optic fiber beam introduction; 3 - endoscopic dissection of the lachrymal sac, describing its position. Results: the most frequent position of the lachrymal sac was between the free border of the middle turbinate and its insertion immediately underneath it. The maxillary line was seen in 95% of the cases. Septoplasty was needed in 12.5%, unicifectomy in 35% and middle turbinectomy in 7.5%. Conclusion: Although the lachrymal sac has a more frequent location, its position varied considerably. The transillumination of the common canaliculus proved useful, solving the problem of the anatomical variability.
Resumo:
Background: The risks for depression broadly include biological and environmental factors. Furthermore, having a family member suffering from major depression is also likely to have consequences for the family environment. Further research aimed at understanding the effects of having a child with major depression on family interaction patterns is warranted. Methods: We studied 31 families with an 8- to 17-year-old child (mean age +/- SD = 12.9 +/- 2.7 years) who met the DSM-IV criteria for major depressive disorder (MDD) and 34 families with no mentally ill children (mean age 8 SD = 12.6 +/- 2.9 years) or parents. Children and their parents were assessed with the K-SADS-PL (Kiddie Schedule for Affective Disorders and Schizophrenia - Present and Lifetime Version) interview. Parents completed the Moos Family Environment Scale (FES) to assess their perceptions of current family functioning. Data were analyzed using the nonparametric Wilcoxon-Mann-Whitney test. Results: Families of MDD children showed significantly different patterns of family functioning on FES subscales representing relationships and personal growth dimensions. The families with MDD children showed higher levels of conflict (p < 0.001) and lower levels of cohesion (p < 0.001), expressiveness (p = 0.003) and active-recreational orientation (p = 0.02) compared to the families without mentally ill children. Conclusion: Families with MDD children show a lower degree of commitment, provide less support to one another, provide less encouragement to express feelings and have more conflicts compared to families with no mentally ill children or parents. Interventions aimed at improving family dynamics may be beneficial to MDD children and their families. Copyright (C) 2010 S. Karger AG, Basel
Resumo:
The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Objective: The purpose of this study was to investigate the reliability and validity of photogrammetry in measuring the lateral spinal inclination angles. Methods: Forty subjects (32 female and 8 males) with a mean age of 23.4 +/- 11.2 years had their scoliosis evaluated by radiographs of their trunk, determined by the Cobb angle method, and by photogrammetry. The statistical methods used included Cronbach alpha, Pearson/Spearman correlation coefficients, and regression analyses. Results: The Cronbach a values showed that the photogrammetric measures showed high internal consistency, which indicated that the sample was bias free. The radiograph method showed to be more precise with intrarater reliabilities of 0.936, 0.975, and 0.945 for the thoracic, lumbar, and thoracolumbar curves, respectively, and interrater reliabilities of 0.942 and 0.879 for the angular measures of the thoracic and thoracolumbar segments, respectively. The regression analyses revealed a high determination coefficient although limited to the adjusted linear model between the radiographic and photographic measures. It was found that with more severe scoliosis, the lateral curve measures obtained with the photogrammetry were for the thoracic and lumbar regions (R = 0.619 and 0.551). Conclusions: The photogrammetric measures were found to be reproducible in this study and could be used as Supplementary information to decrease the number of radiographs necessary for the monitoring of scoliosis. (J Manipulative Physiol Ther 2009;32:423-430)
Resumo:
Blood pressure (BP) measurement is the basis for the diagnosis and management of arterial hypertension. The aim of this study was to compare BP measurements performed in the office and at home (home blood pressure monitoring, HBPM) in children and adolescents with chronic arterial hypertension. HBPM was performed by the patient or by his/her legal guardian. During a 14-day period, three BP measurements were performed in the morning or in the afternoon (daytime measurement) and in the evening (night-time measurement), with 1-min intervals between measurements, totalling six measurements per day. HBPM was defined for systolic blood pressure (SBP) and diastolic blood pressure (DBP) values. HBPM was evaluated in 40 patients (26 boys), mean age of 12.1 years (4-18 years). SBP and DBP records were analysed. The mean differences between average HBP and doctor`s office BP were 0.6 +/- 14 and 4 +/- 13 mm Hg for SBP and DBP, respectively. Average systolic HBPM (daytime and night-time) did not differ from average office BP, and diastolic HBPM (daytime and night-time) was statistically lower than office BP. The comparison of individual BP measurements along the study period (13 days) by s.d. of differences shows a significant decline only for DBP values from day 5, on which difference tends to disappear towards the end of the study. Mean daytime and night-time SBP and DBP values remained stable throughout the study period, confirming HBPM as an acceptable methodology for BP evaluation in hypertensive children and adolescents. Journal of Human Hypertension (2009) 23, 464-469; doi:10.1038/jhh.2008.167; published online 12 March 2009
Resumo:
Background: We studied the characteristics of family functioning in bipolar children and healthy comparison children. We hypothesized that the family environment of bipolar children would show greater levels of dysfunction as measured by the Family Environment Scale (FES). Methods: We compared the family functioning of 36 families that included a child with DSM-IV bipolar disorder versus 29 comparison families that included only healthy children. All subjects and their parents were assessed with the K-SADS-PL interview. The parents completed the FES to assess their current family functioning. Multivariate analysis of variance was used to compare the family environment of families with and without offspring with bipolar disorder. Results: Parents of bipolar children reported lower levels of family cohesion (p<0.001), expressiveness (p=0.005), active-recreational orientation (p<0.001), intellectual-cultural orientation (p=0.04) and higher levels of conflict (p<0.001) compared to parents with no bipolar children. Secondary analyses within the bipolar group revealed lower levels of organization (p=0.03 1) and cohesion (p=0.014) in families where a parent had a history of mood disorders compared to families where parents had no history of mood disorders. Length of illness in the affected child was inversely associated with family cohesion (r=-0.47, p=0.004). Limitations: Due to the case-control design of the study, we cannot comment on the development of these family problems or attribute their cause specifically to child bipolar disorder. Conclusion: Families with bipolar children show dysfunctional patterns related to interpersonal interactions and personal growth. A distressed family environment should be addressed when treating children with bipolar disorder. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Purpose: The purpose of our study was to compare signal characteristics and image qualities of MR imaging at 3.0 T and 1.5 T in patients with diffuse parenchymal liver disease. Materials and methods: 25 consecutive patients with diffuse parenchymal liver disease underwent abdominal MR imaging at both 3.0 T and 1.5 T within a 6-month interval. A retrospective study was conducted to obtain quantitative and qualitative data from both 3.0 T and 1.5 T MRI. Quantitative image analysis was performed by measuring the signal-to-noise ratios (SNRs) and the contrast-to-noise ratios (CNRs) by the Students t-test. Qualitative image analysis was assessed by grading each sequence on a 3- and 4-point scale, regarding the presence of artifacts and image quality, respectively. Statistical analysis consisted of the Wilcoxon signed-rank test. Results: the mean SNRs and CNRs of the liver parenchyma and the portal vein were significantly higher at 3.0 T than at 1.5 T on portal and equilibrium phases of volumetric interpolated breath-hold examination (VIBE) images (P < 0.05). The mean SNRs were significantly higher at 3.0 T than at 1.5 T on T1-weighted spoiled gradient echo (SGE) images (P < 0.05). However, there were no significantly differences on T2-weighted short-inversion-time inversion recovery (STIR) images. Overall image qualities of the 1.5 T noncontrast T1- and T2-weighted sequences were significantly better than 3.0 T (P < 0.01). In contrast, overall image quality of the 3.0 T post-gadolinium VIBE sequence was significantly better than 1.5 T (P< 0.01). Conclusions: MR imaging of post-gadolinium VIBE sequence at 3.0 T has quantitative and qualitative advantages of evaluating for diffuse parenchymal liver disease. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
Objective(s): We intend to verify if fetal volume and crown-rump length were different between singletons and twins in pregnancies aged from 7 to 10 weeks and to evaluate if fetal volume is more accurate to determine the gestational age than crown-rump length at this gestational age. Study design: From 52 days (7 weeks and 3 days) to 73 days (10 weeks and 3 days) weekly three-dimensional Ultrasonography was per-formed in 20 twin fetuses and 20 singletons. Crown-rump length and fetal volume using VOCAL were assessed in all examinations. The `true` gestational age was based on oocyte retrieval. Results: At the age of 52 days, the crown-rump length was 11.74 +/- 0.27 mm (mean +/- S.D.) and 11.48 +/- 0.22 mm (singletons and twins, respectively), while the fetal volume was 0.354 +/- 0.015 cm(3) and 0.324 +/- 0.012 cm(3). At the gestational age of 73 days, the crown-rump length was 36.19 +/- 0.90 mm and 35.87 +/- 0.54 mm and the fetal volume was 6.204 +/- 0.090 cm(3) and 6.083 +/- 0.081 cm(3). The total relative increase observed was much higher for fetal volume than for CRL: 1705 +/- 301% vs. 210 +/- 33% in singletons and 1827 +/- 305% vs. 214 +/- 25% in twins. The 95% limits of agreement (+/- 2.3 days vs. +/- 3.2 days, fetal volume vs. crown-rump length) and the intraclass correlation coefficients (0.989 vs. 0.978) between the ""true"" gestational age and that predicted by fetal volume were better than those predicted by crown-rump length. No significant difference was identified between singletons and twins for both fetal volume and crown-rump length. Conclusion(s): Twins and singletons had similar fetal volume and crown-rump length between the 7th and 10th week of gestational age. Additionally, fetal volume assessed by VOCAL was better than crown-rump length to estimate the gestational age at the evaluated period. However, the improvement was small and probably without clinical significance. Condensation: Fetal volume and crown-rump length were similar between singletons and twins. Fetal volume relative increase was higher and the predicted gestational age was better. (c) 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Objectives: Studies have shown that women previously treated for breast cancer present fewer cardiovascular events, indicating a possible protective effect of tamoxifen treatment. The effects of these aromatase inhibitors on cardiovascular protection remain controversial. The aim of this study was to compare some cardiovascular risk markers among breast cancer survivors following treatment with tamoxifen group (TMXg), letrozole group (LTZg) or no endocrine treatment group (NETg). Methods: A total of 103 breast cancer survivors: 35 using TMXg, 34 using letrozole group (LTZg) and 34 using no endocrine treatment group (NETg) were evaluated. Ultrasonographic evaluation of brachial artery flow-mediated dilation (FMD), carotid intima-media thickness (IMT) and stiffness index (beta); blood total cholesterol, HDL and triglycerides were assessed. Results: All three groups presented similar values of HDL and IMT. TMXg showed the lowest total cholesterol (219.29 +/- 36.31 mg/dL vs. 250.59 +/- 38.37 mg/dL vs. 245.09 +/- 35.35 mg/dL; TMXg vs. LTZg vs. NETg, respectively; p < 0.01-ANOVA), the highest triglycerides (139.34 +/- 41.82 mg/dL vs. 111.35 +/- 28.22 mg/dL vs.122.09 +/- 33.42 mg/dL; p < 0.01), the highest FMD (6.32 +/- 2.33% vs. 4.10 +/- 2.06% vs. 4.66 +/- 2.52%; p < 0.01) and the lowest stiffness index (beta) (5.08 +/- 1.68 vs. 6.28 +/- 1.75 vs. 5.99 +/- 1.86; p=0.01). LTZg did not differ significantly from NETg on any evaluated parameter. Conclusions: We did not observe any effect of LTZg on the evaluated cardiovascular risk parameters compared to NETg. As such, the observed difference on lipid values, stiffness index (beta) and FMD between women receiving tamoxifen anti letrozole might be best attributed to the beneficial effect of tamoxifen than to a detrimental effect of letrozole. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
Resumo:
The aim of this study was to compare the crown-rump length (CRL) and the fetal head and trunk (HT) volume between singletons and twins conceived after in vitro fertilization. Thirty pregnant patients submitted to embryo transfer were enrolled in this research. Ten conceived twins (20 dichorionic fetuses) while other 20 conceived singletons. The gestational age was calculated by adding 14 d to the number of days between the oocyte retrieval and the scheduled ultrasound. Three-dimensional ultrasound scans were performed weekly from 73 d (10 wk and 3 d) to 101 d (14 wk and 3 d) of gestational age. HT volume was assessed by VOCAL using 15 degrees step rotation on the manual mode. The measurement of CRL was performed by using the longitudinal plane of the fetus in the multiplanar view. The CRL and HT volume weekly relative increase were evaluated to compare the growth between singletons and twins. No significant difference was identified, in any analyzed week, when comparing the mean of CRL and HT volume between singletons and twins. Additionally, no significant difference between singletons and twins was noticed when comparing the weekly relative increase, both for CRL and HT volume. However, the weekly relative increase was significantly higher for HT volume than for CRL in every week studied for both singletons and twins. The total relative increase observed between 73 and 101 d was much higher for HT volume than for CRL: 679 +/- 39% versus 138 +/- 18% in singletons and 689 +/- 58% versus 139 +/- 21% in twins (HT volume and CRL, respectively), suggesting that HT volume could more accurately determine the gestational age.
Resumo:
Objective. Endothelial impairment evaluation by sonographic measurement of flow-mediated dilatation (FMD) has become broadly used. However, this method has 2 main caveats: the dilatation depends on the baseline arterial diameter, and a high precision level is required. Vasodilatation leads to an amplified fall in impedance. We hypothesized that assessment of the pulsatility index change (PI-C) 1 minute after 5-minute forearm compression might evaluate that fall in impedance. The aim of this study was to compare the PI-C with FMD. Methods. Flow-mediated dilatation and the PI-C were assessed in 51 healthy women aged between 35.1 and 67.1 years. We correlated both FMD and the PI-C with age, body mass index, waist circumference, cholesterol level, high-density lipoprotein level, glucose level, systolic and diastolic blood pressure, pulse pressure, brachial artery diameter, simplified Framingham score, intima-media thickness, and carotid stiffness index. Intraclass correlation coefficients between 2 FMD and PI-C measurements were also examined. Results. Only FMD correlated with baseline brachial diameter (r=-0.53). The PI-C had a high correlation with age, body mass index, waist circumference, cholesterol level, systolic blood pressure, pulse pressure, simplified Framingham score, and intima-media thickness. The correlation between FMD and the PI-C was high (r=-0.66). The PI-C had a higher intraclass correlation coefficient (0.991) than FMD (0.836) but not brachial artery diameter (0.989). Conclusions. The PI-C had a large correlation with various markers of cardiovascular risk. Additionally, PI-C measurement does not require offline analysis, extra software, or electrocardiography We think that the PI-C could be considered a marker of endothelial function. However, more studies are required before further conclusions.
Resumo:
The aim of this study was to compare the intra-and inter-rater reliability of pressure pain threshold (PPT) and manual palpation (MP) of orofacial structures in symptomatic and symptom-free children for temporomandibular disorders (TMD). Fourteen children reporting pain in masticatory muscles or the temporomandibular joint and 16 symptom-free children were randomly assessed on three different occasions: by rater-1 in the first and third session and by rater-2 in the second session. The trained raters applied algometry and MP as recommended by the Research Diagnostic Criteria for TMD. Intraclass correlation coefficients and the Kappa statistic were used to assess the levels of reliability of PPT and MP, respectively. Excellent intra-and inter-rater reliability levels were observed for PPT values at most of the examined sites for symptom-free children and excellent and moderate reliability levels for children reporting pain. For MP, moderate and poor intra-rater and inter-rater reliability levels were observed for most sites in both groups. Algometry showed higher reliability levels for both groups of children and is recommended for pain assessment in children in association with MP. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
The mechanical alterations related to the excessive use of accessory respiratory muscles and the mouth breathing observed in children with asthma may lead to the development of alterations in head posture, shoulders, thoracic region and, consequently, in alterations of body posture. The purpose of this study was to assess body posture changes of children with asthma compared to a non-asthmatic control group matched for gender, age, weight, and height. Thirty children with asthma and 30 non-asthmatic children aged 7 to 12 years were enrolled in this study. Digital photographic records were obtained for analysis of the body posture of the children by computed photogrammetry. The intraclass correlation coefficient and Student`s t test (p < 0.05) were used for statistical analysis. There were no significant differences between groups for the angles analyzed, except for the knee flexor angle. These results demonstrate that children with asthma did not present postural alterations compared to non-asthmatic controls since the only angle for which there was a significant difference between groups showed weak reproducibility. The findings of this study do not support the notion that children with asthma present alterations in body posture.