816 resultados para injury healing
Resumo:
An easy access to a library of simple organic salts derived from tert-butoxycarbonyl (Boc)-protected L-amino acids and two secondary amines (dicyclohexyl- and dibenzyl amine) are synthesized following a supramolecular synthon rationale to generate a new series of low molecular weight gelators (LMWGs). Out of the 12 salts that we prepared, the nitrobenzene gel of dicyclohexylammonium Boc-glycinate (GLY.1) displayed remarkable load-bearing, moldable and self-healing properties. These remarkable properties displayed by GLY.1 and the inability to display such properties by its dibenzylammonium counterpart (GLY.2) were explained using microscopic and rheological data. Single crystal structures of eight salts displayed the presence of a 1D hydrogen-bonded network (HBN) that is believed to be important in gelation. Powder X-ray diffraction in combination with the single crystal X-ray structure of GLY.1 clearly established the presence of a 1D hydrogen-bonded network in the xerogel of the nitrobenzene gel of GLY.1. The fact that such remarkable properties arising from an easily accessible (salt formation) small molecule are due to supramolecular (non-covalent) interactions is quite intriguing and such easily synthesizable materials may be useful in stress-bearing and other applications.
Resumo:
The healing times for the growth of thin films on patterned substrates are studied using simulations of two discrete models of surface growth: the Family model and the Das Sarma-Tamborenea (DT) model. The healing time, defined as the time at which the characteristics of the growing interface are ``healed'' to those obtained in growth on a flat substrate, is determined via the study of the nearest-neighbor height difference correlation function. Two different initial patterns are considered in this work: a relatively smooth tent-shaped triangular substrate and an atomically rough substrate with singlesite pillars or grooves. We find that the healing time of the Family and DT models on aL x L triangular substrate is proportional to L-z, where z is the dynamical exponent of the models. For the Family model, we also analyze theoretically, using a continuum description based on the linear Edwards-Wilkinson equation, the time evolution of the nearest-neighbor height difference correlation function in this system. The correlation functions obtained from continuum theory and simulation are found to be consistent with each other for the relatively smooth triangular substrate. For substrates with periodic and random distributions of pillars or grooves of varying size, the healing time is found to increase linearly with the height (depth) of pillars (grooves). We show explicitly that the simulation data for the Family model grown on a substrate with pillars or grooves do not agree with results of a calculation based on the continuum Edwards-Wilkinson equation. This result implies that a continuum description does not work when the initial pattern is atomically rough. The observed dependence of the healing time on the substrate size and the initial height (depth) of pillars (grooves) can be understood from the details of the diffusion rule of the atomistic model. The healing time of both models for pillars is larger than that for grooves with depth equal to the height of the pillars. The calculated healing time for both Family and DT models is found to depend on how the pillars and grooves are distributed over the substrate. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
Two-component super-hydrogelation triggered by the acid-base interaction of a L-histidine appended pyrenyl derivative (PyHis) and phthalic acid (PA) was reported. The use of isomeric isophthalic or terephthalic acid or other comparable acids in place of PA does not lead to salt formation and therefore hydrogelation is not observed. Excimer formation of the pyrenyl unit has not been detected although the PyHis : PA = 1: 1 system undergoes extensive self-assembly in aqueous solution. The synergistic effect of intermolecular H-bonding forces, pi-pi stacking, electrostatic interactions, etc. is found to be responsible for robust hydrogel formation. Development of chiral supramotecular assemblies has been verified through circular dichroism spectroscopy. Morphological investigations involving the PyHis : PA = 1: 1 system show vesicular nano-structures with a definite bilayer width at relatively low concentrations. The latter fuses to construct coiled-coil left-handed helical fibers upon increase in the concentrations of the gelators. The intertwining of the resultant helical fibers eventually results in hydrogel formation. The probable bilayer packing in the self-assembled structures has been probed using X-ray diffraction (XRD) studies and lanthanide sensitization, which suggests that the polar imidazolium hydrogen phthalate unit of the gelator forms the head group and faces the hydrophilic water environment while the hydrophobic pyrenyl units sit inside the hydrophobic core of the bilayer. The hydrogel exhibits multi-stimuli responsiveness including thixotropic behavior. In addition, shape-persistent as well as rapid self-healing behaviour of the hydrogel was established. Furthermore load-bearing characteristics of the hydrogel have also been demonstrated.
Resumo:
We present the circuit board integration of a self-healing mechanism to repair open faults. The electric field driven mechanism physically restores fractured interconnects in electronic circuits and has the ability to solve mazes. The repair is performed by conductive particles dispersed in an insulating fluid. We demonstrate the integration of the healing module onto printed circuit boards and the ability of maze solving. We model and perform experiments on the influence of the geometry of conductive particles as well as the terminal impedances of the route on the healing efficiency. The typical heal rate is 10 mu m/s with healed route having mean resistance of 8 k Omega across a 200 micron gap and depending on the materials and concentrations used. (C) 2015 AIP Publishing LLC.
Resumo:
The molecular dynamics method is used to simulate microcrack healing during heating or/and under compressive stress. A centre microcrack in Cu crystal would be sealed under compressive stress or by heating. The role of compressive stress and heating in crack healing was additive. During microcrack healing, dislocation generation and motion occurred. When there were pre-existing dislocations around the microcrack, the critical temperature or compressive stress necessary for microcrack healing would decrease, and, the higher the number of dislocations, the lower the critical temperature or compressive stress. The critical temperature necessary for microcrack healing depended upon the orientation of the crack plane. For example, the critical temperature for the crack along the (001) plane was the lowest, i.e. 770K.
Resumo:
[EN] Diabetic foot ulcers (DFUs) represent a major clinical challenge in the ageing population. To address this problem, rhEGF-loaded Poly-Lactic-co-Glycolic-Acid (PLGA)-Alginate microspheres (MS) were prepared by a modified w/o/w-doubleemulsion/ solvent evaporation method. Different formulations were evaluated with the aim of optimising MSs properties by adding NaCl to the surfactant solution and/or the solvent removal phase and adding alginate as a second polymer. The characterization of the developed MS showed that alginate incorporation increased the encapsulation efficiency (EE) and NaCl besides increasing the EE also became the particle surface smooth and regular. Once the MS were optimised, the target loading of rhEGF was increased to 1% (PLGA-Alginate MS), and particles were sterilised by gamma radiation to provide the correct dosage for in vivo studies. In vitro cell culture assays demonstrated that neither the microencapsulation nor the sterilisation process affected rhEGF bioactivity or rhEGF wound contraction. Finally, the MS were evaluated in vivo for treatment of the full-thickness wound model in diabetised Wistar rats. rhEGF MS treated animals showed a statistically significant decrease of the wound area by days 7 and 11, a complete re-epithelisation by day 11 and an earlier resolution of the inflammatory process. Overall, these findings demonstrate the promising potential of rhEGF-loaded MS (PLGA-Alginate MS) to promote faster and more effective wound healing, and suggest its possible application in DFU treatment.
Resumo:
Therapy employing epidural electrostimulation holds great potential for improving therapy for patients with spinal cord injury (SCI) (Harkema et al., 2011). Further promising results from combined therapies using electrostimulation have also been recently obtained (e.g., van den Brand et al., 2012). The devices being developed to deliver the stimulation are highly flexible, capable of delivering any individual stimulus among a combinatorially large set of stimuli (Gad et al., 2013). While this extreme flexibility is very useful for ensuring that the device can deliver an appropriate stimulus, the challenge of choosing good stimuli is quite substantial, even for expert human experimenters. To develop a fully implantable, autonomous device which can provide useful therapy, it is necessary to design an algorithmic method for choosing the stimulus parameters. Such a method can be used in a clinical setting, by caregivers who are not experts in the neurostimulator's use, and to allow the system to adapt autonomously between visits to the clinic. To create such an algorithm, this dissertation pursues the general class of active learning algorithms that includes Gaussian Process Upper Confidence Bound (GP-UCB, Srinivas et al., 2010), developing the Gaussian Process Batch Upper Confidence Bound (GP-BUCB, Desautels et al., 2012) and Gaussian Process Adaptive Upper Confidence Bound (GP-AUCB) algorithms. This dissertation develops new theoretical bounds for the performance of these and similar algorithms, empirically assesses these algorithms against a number of competitors in simulation, and applies a variant of the GP-BUCB algorithm in closed-loop to control SCI therapy via epidural electrostimulation in four live rats. The algorithm was tasked with maximizing the amplitude of evoked potentials in the rats' left tibialis anterior muscle. These experiments show that the algorithm is capable of directing these experiments sensibly, finding effective stimuli in all four animals. Further, in direct competition with an expert human experimenter, the algorithm produced superior performance in terms of average reward and comparable or superior performance in terms of maximum reward. These results indicate that variants of GP-BUCB may be suitable for autonomously directing SCI therapy.
Resumo:
With continuing advances in CMOS technology, feature sizes of modern Silicon chip-sets have gone down drastically over the past decade. In addition to desktops and laptop processors, a vast majority of these chips are also being deployed in mobile communication devices like smart-phones and tablets, where multiple radio-frequency integrated circuits (RFICs) must be integrated into one device to cater to a wide variety of applications such as Wi-Fi, Bluetooth, NFC, wireless charging, etc. While a small feature size enables higher integration levels leading to billions of transistors co-existing on a single chip, it also makes these Silicon ICs more susceptible to variations. A part of these variations can be attributed to the manufacturing process itself, particularly due to the stringent dimensional tolerances associated with the lithographic steps in modern processes. Additionally, RF or millimeter-wave communication chip-sets are subject to another type of variation caused by dynamic changes in the operating environment. Another bottleneck in the development of high performance RF/mm-wave Silicon ICs is the lack of accurate analog/high-frequency models in nanometer CMOS processes. This can be primarily attributed to the fact that most cutting edge processes are geared towards digital system implementation and as such there is little model-to-hardware correlation at RF frequencies.
All these issues have significantly degraded yield of high performance mm-wave and RF CMOS systems which often require multiple trial-and-error based Silicon validations, thereby incurring additional production costs. This dissertation proposes a low overhead technique which attempts to counter the detrimental effects of these variations, thereby improving both performance and yield of chips post fabrication in a systematic way. The key idea behind this approach is to dynamically sense the performance of the system, identify when a problem has occurred, and then actuate it back to its desired performance level through an intelligent on-chip optimization algorithm. We term this technique as self-healing drawing inspiration from nature's own way of healing the body against adverse environmental effects. To effectively demonstrate the efficacy of self-healing in CMOS systems, several representative examples are designed, fabricated, and measured against a variety of operating conditions.
We demonstrate a high-power mm-wave segmented power mixer array based transmitter architecture that is capable of generating high-speed and non-constant envelope modulations at higher efficiencies compared to existing conventional designs. We then incorporate several sensors and actuators into the design and demonstrate closed-loop healing against a wide variety of non-ideal operating conditions. We also demonstrate fully-integrated self-healing in the context of another mm-wave power amplifier, where measurements were performed across several chips, showing significant improvements in performance as well as reduced variability in the presence of process variations and load impedance mismatch, as well as catastrophic transistor failure. Finally, on the receiver side, a closed-loop self-healing phase synthesis scheme is demonstrated in conjunction with a wide-band voltage controlled oscillator to generate phase shifter local oscillator (LO) signals for a phased array receiver. The system is shown to heal against non-idealities in the LO signal generation and distribution, significantly reducing phase errors across a wide range of frequencies.
Resumo:
Shockwave lithotripsy is a noninvasive medical procedure wherein shockwaves are repeatedly focused at the location of kidney stones in order to pulverize them. Stone comminution is thought to be the product of two mechanisms: the propagation of stress waves within the stone and cavitation erosion. However, the latter mechanism has also been implicated in vascular injury. In the present work, shock-induced bubble collapse is studied in order to understand the role that it might play in inducing vascular injury. A high-order accurate, shock- and interface-capturing numerical scheme is developed to simulate the three-dimensional collapse of the bubble in both the free-field and inside a vessel phantom. The primary contributions of the numerical study are the characterization of the shock-bubble and shock-bubble-vessel interactions across a large parameter space that includes clinical shockwave lithotripsy pressure amplitudes, problem geometry and tissue viscoelasticity, and the subsequent correlation of these interactions to vascular injury. Specifically, measurements of the vessel wall pressures and displacements, as well as the finite strains in the fluid surrounding the bubble, are utilized with available experiments in tissue to evaluate damage potential. Estimates are made of the smallest injurious bubbles in the microvasculature during both the collapse and jetting phases of the bubble's life cycle. The present results suggest that bubbles larger than 1 μm in diameter could rupture blood vessels under clinical SWL conditions.
Mitigating Scarring and Inflammation during Corneal Wound Healing using Nanofiber-Hydrogel Scaffolds
Resumo:
Due to the universal lack of donor tissue, there has been emerging interest in engineering materials to stimulate living cells to restore the features and functions of injured organs. We are particularly interested in developing materials for corneal use, where the necessity to maintain the tissue’s transparency presents an additional challenge. Every year, there are 1.5 – 2 million new cases of monocular blindness due to irregular healing of corneal injuries, dwarfing the approximately 150,000 corneal transplants performed. The large gap between the need and availability of cornea transplantation motivates us to develop a wound-healing scaffold that can prevent corneal blindness.
To develop such a scaffold, it is necessary to regulate the cells responsible for repairing the damaged cornea, namely myofibroblasts, which are responsible for the disordered and non-refractive index matched scar that leads to corneal blindness. Using in vitro assays, we identified that protein nanofibers of certain orientation can promote cell migration and modulate the myofibroblast phenotype. The nanofibers are also transparent, easy to handle and non-cytotoxic. To adhere the nanofibers to a wound bed, we examined the use of two different in situ forming hydrogels: an artificial extracellular matrix protein (aECM)-based gel and a photo-crosslinkable heparin-based gel. Both hydrogels can be formed within minutes, are transparent upon gelation and are easily tunable.
Using an in vivo mouse model for epithelial defects, we show that our corneal scaffolds (nanofibers together with hydrogel) are well-tolerated (no inflammatory response or turbidity) and support epithelium regrowth. We developed an ex vivo corneal tissue culture model where corneas that are wounded and treated with our scaffold can be cultured while retaining their ability to repair wounds for up to 21 days. Using this technique, we found that the aECM-based treatment induced a more favorable wound response than the heparin-based treatment, prompting us to further examine the efficacy of the aECM-based treatment in vivo using a rabbit model for stromal wounds. Results show that treated corneas have fewer myofibroblasts and immune cells than untreated ones, indicating that our corneal scaffold shows promise in promoting a calmer wound response and preventing corneal haze formation.
Resumo:
Ruptura do tendão calcâneo é uma das lesões tendíneas mais frequentes. Embora a maioria dos trabalhos sugira que o exercício seja benéfico na cicatrização tendínea, não há consenso sobre o efeito do antiinflamatório neste contexto. Trabalhos experimentais tentam reproduzir lesão aguda deste tendão, em diferentes espécies animais. Neste estudo, descrevemos uma técnica de tenotomia completa do tendão calcâneo direito em ratos e, em seguida, avaliamos os efeitos do uso do antiinflamatório e do exercício aeróbico, isoladamente e em combinação, sobre a proliferação celular e o perfil biomecânico do tendão calcâneo, durante o processo de cicatrização após tenotomia. Estudo experimental com 156 ratos machos adultos, da raça Wistar, com idade média de 3 meses e peso médio de 300g. Após anestesia com tiopental e com auxílio da microscopia de luz, foi realizada incisão longitudinal posterior de cinco milímetros, em direção proximal, a partir da tuberosidade posterior do calcâneo da pata direita do rato. Foi feito corte transversal do tendão calcâneo, a sete milímetros da tuberosidade do calcâneo, com preservação do tendão plantar. Utilizamos as técnicas de Hematoxilina e Eosina, Picrosirius-red e Resorcina-fucsina de Weigert para avaliação da cicatrização tendínea e das fibras dos sistemas colágeno e elástico. Após a tenotomia, metade dos animais receberam tenoxicam intramuscular por 7 dias e no 8o dia iniciou-se protocolo de exercício em esteira na metade de cada grupo. Os ratos foram divididos aleatoriamente em 4 grupos de tratamento: A sem antiinflamatório E sem exercício (controle); B com antiinflamatório E com exercício; C sem antiinflamatório E com exercício; D com antiinflamatório E sem exercício. Os animais foram eutanasiados com 1, 2, 4 e 8 semanas após a tenotomia, para avaliação histológica pelo PCNA, e biomecânica através do teste de resistência à tração e da medida do ciclo locomotor. Foram realizados análise de variância, teste de Kruskal-Wallis e o método de Bonferroni, no programa R Project, versão 2.11.1. O tempo cirúrgico médio foi de 1 minuto e 24 segundos, sem complicações observadas até a 8a semana pós-operatória. Observamos proliferação celular e fibrilogênese com duas semanas, e diminuição da celularidade e das fibras elásticas na 8a semana, além de mudanças na organização estrutural do sistema colágeno. Encontramos pico da imunomarcação com PCNA na 2a semana em todos os grupos, exceto no grupo A, cujo pico aconteceu com 1 semana da tenotomia. Evidenciamos resistência à tração significativamente maior (p=0,02) nos ratos submetidos ao exercício, 8 semanas após ruptura. Nos grupos com antiinflamatório, observamos um ciclo locomotor mais estável durante todo o tempo avaliado. Consideramos a técnica cirúrgica experimental de tenotomia completa do tendão calcâneo, realizada com auxílio da microscopia de luz e preservação do tendão plantar, simples, rápida, com sinais de cicatrização tendínea normal e de fácil reprodução em ratos. O exercício aeróbico, iniciado precocemente após tenotomia completa do tendão calcâneo, é significativamente benéfico na sua recuperação biomecânica e o uso combinado com antiinflamatório confere maior estabilidade na marcha, o que pode proteger contra rerruptura tendínea em ratos
Resumo:
O propósito do presente trabalho foi investigar a participação da proliferação celular e da expressão dos componentes da matriz extracelular na cascata de eventos do processo de reparo da fratura óssea, empregando as técnicas histológica, imunohistoquímica e morfométrica, em um modelo experimental padronizado para a indução da lesão na tíbia de ratos a partir do método empregado por Yuehuei e Friedman7. É importante padronizar um modelo de indução da fratura, para posterior investigação da participação das células e dos componentes da matriz extracelular no processo de reparo da fratura, considerando que o tempo de consolidação depende significantemente da natureza e do tipo da lesão produzida. Quarenta (n = 40) ratos Wistar foram submetidos a fratura . Os animais foram avaliados em oito (n = 8) grupos de cinco (n = 5) animais, cada grupo emperimental com 12, 24, 48, 72, 96, 144, 192 e 240 horas após a fratura (12h até 10 dias). As fraturas foram classificadas de acordo com o sistema de classificação internacional de fratura de Muller100, AO (Associação para Osteosíntese). Foram encontradas fraturas simples em 86% do total, sendo 68% de fraturas transversas e 18% de fraturas obliquas, 14% do total de fraturas foram complexas, sendo 8% de fraturas irregulares e 6% de fraturas segmentares. Esses resultados demonstram que o aparelho permite padronizar radiológicamente o tipo de fratura, caracterizado pela linha que separa os fragmentos ósseos. Os resultados qualitativos dos componentes da matriz extracelular para TGF-β, VEGF, colágeno I e II, osteopontina, proteoglicanos, fibras do sistema elástico com a coloração de resorcina funcsina de Weigert, e para proliferação celular pelo PCNA, assim como os resultados morfométricos, sugerem que a modulação da expressão dos componentes da matriz extracelular e a proliferação celular durante o processo de reparo da fratura não é homogênea para todos os componentes teciduais, dependendo significantemente das tensões locais geradas pelo tipo da linha de fratura que pode ser determinante no tempo de regeneração do osso e na qualidade da restauração das propriedades biomecânica. Nossos achados podem contribuir para melhor compreensão da reparo de fratura óssea e para novas abordagens terapêuticas que considerem as propriedades biomecânicas do tecido ósseo em reparo nas suas diferentes etapas
Resumo:
192 p.