991 resultados para implant-supported prosthesis


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To provide 2-year clinical- and patient-oriented data with regard to mandibular overdenture assisted by 2 immediately loaded unsplinted implants. Material and methods In this pre-post design, Phase-I clinical trial, 18 edentate individuals (62.4 ± 7.7 years) received a new set of complete denture. Then, following standard procedures, 3 threaded implants (OsseoSpeed TX™, Dentsply Implants, Mölndal, Sweden) were placed in the mandible in each patient, and locator abutments (Zest Anchors LLC, Escondido, U.S.A.) were inserted on the right and left side implants. The midline implant served as a control for within-patient comparison. The immediate loading was conducted within 24 h of surgery. Data were collected at baseline (T0), 12 (T1) and 24 (T2) months after immediate loading. The clinical outcomes included implant survival rate, crestal bone level changes and implant stability. These criteria were assessed through clinical and radiographic examinations as well as resonance frequency analysis. Patient-centered outcomes included patient satisfaction and oral health-related quality of life measured using validated questionnaires. Brunner-Langer approach was used for statistical analysis. Results Implant survival rate for immediate loaded implants was 91.7% at 2-year follow-up. None of the unloaded implants failed. There was no statistically significant difference at baseline and follow-ups with regard to clinical outcomes between loaded and unloaded implants. Patient satisfaction and quality of life improved (p < 0.0001) from baseline to 2-year follow-up. Conclusion Immediate loading protocol did not negatively affect clinical outcomes, satisfaction and quality of life of patients wearing 2-unsplinted-implant mandibular overdenture for 2 years. This conclusion requires confirmation by randomized control trials. Clinical significance statement Mandibular overdenture assisted by two immediately-loaded unsplinted implants is successful treatment based on 2-year clinical and patient-based outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To provide 2-year clinical- and patient-oriented data with regard to mandibular overdenture assisted by 2 immediately loaded unsplinted implants. Material and methods In this pre-post design, Phase-I clinical trial, 18 edentate individuals (62.4 ± 7.7 years) received a new set of complete denture. Then, following standard procedures, 3 threaded implants (OsseoSpeed TX™, Dentsply Implants, Mölndal, Sweden) were placed in the mandible in each patient, and locator abutments (Zest Anchors LLC, Escondido, U.S.A.) were inserted on the right and left side implants. The midline implant served as a control for within-patient comparison. The immediate loading was conducted within 24 h of surgery. Data were collected at baseline (T0), 12 (T1) and 24 (T2) months after immediate loading. The clinical outcomes included implant survival rate, crestal bone level changes and implant stability. These criteria were assessed through clinical and radiographic examinations as well as resonance frequency analysis. Patient-centered outcomes included patient satisfaction and oral health-related quality of life measured using validated questionnaires. Brunner-Langer approach was used for statistical analysis. Results Implant survival rate for immediate loaded implants was 91.7% at 2-year follow-up. None of the unloaded implants failed. There was no statistically significant difference at baseline and follow-ups with regard to clinical outcomes between loaded and unloaded implants. Patient satisfaction and quality of life improved (p < 0.0001) from baseline to 2-year follow-up. Conclusion Immediate loading protocol did not negatively affect clinical outcomes, satisfaction and quality of life of patients wearing 2-unsplinted-implant mandibular overdenture for 2 years. This conclusion requires confirmation by randomized control trials. Clinical significance statement Mandibular overdenture assisted by two immediately-loaded unsplinted implants is successful treatment based on 2-year clinical and patient-based outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Total knee arthroplasty (TKA) has revolutionized the life of millions of patients and it is the most efficient treatment in cases of osteoarthritis. The increase in life expectancy has lowered the average age of the patient, which requires a more enduring and performing prosthesis. To improve the design of implants and satisfying the patient's needs, a deep understanding of the knee Biomechanics is needed. To overcome the uncertainties of numerical models, recently instrumented knee prostheses are spreading. The aim of the thesis was to design and manifacture a new prototype of instrumented implant, able to measure kinetics and kinematics (in terms of medial and lateral forces and patellofemoral forces) of different interchangeable designs of prosthesis during experiments tests within a research laboratory, on robotic knee simulator. Unlike previous prototypes it was not aimed for industrial applications, but purely focusing on research. After a careful study of the literature, and a preliminary analytic study, the device was created modifying the structure of a commercial prosthesis and transforming it in a load cell. For monitoring the kinematics of the femoral component a three-layers, piezoelettric position sensor was manifactured using a Velostat foil. This sensor has responded well to pilot test. Once completed, such device can be used to validate existing numerical models of the knee and of TKA and create new ones, more accurate.It can lead to refinement of surgical techniques, to enhancement of prosthetic designs and, once validated, and if properly modified, it can be used also intraoperatively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Reconstruction of the distal femur after resection for malignant bone tumors in skeletally immature children is challenging. The use of megaprostheses has become increasingly popular in this patient group since the introduction of custom-made, expandable devices that do not require surgery for lengthening, such as the Repiphysis(®) Limb Salvage System. Early reports on the device were positive but more recently, a high complication rate and associated bone loss have been reported. QUESTIONS/PURPOSES: We asked: (1) what are the clinical outcomes using the Musculoskeletal Tumor Society (MSTS) scoring system after 5-year minimum followup in patients treated with this prosthesis at one center; (2) what are the problems and complications associated with the lengthening procedures of this implant; and (3) what are the specific concerns associated with revision of this implant? METHODS: At our institute, between 2002 and 2007, the Repiphysis(®) expandable prosthesis was implanted in 15 children (mean age, 8 years; range, 6-11 years) after distal femoral resection for malignant bone tumors. During this time, the general indication for use of this implant was resection of the distal femur for localized malignant bone tumors in pediatric patients. Alternative techniques used for this indication were modular prosthetic reconstruction, massive (osteoarticular or intercalary) allograft reconstruction, or rotationplasty. Age and tumor extension were the main factors to decide on the surgical indication. Of the 15 patients who had this prosthesis implanted during reconstruction surgery, five died with the implant in situ or underwent amputation before 5 years followup and the remaining 10 were evaluated at a minimum of 5 years (mean, 104 months; range, 78-140 months). No patients were lost to followup. These 10 patients were long-term survivors and underwent the lengthening program. They were included in our study analysis. The first seven lengthening procedures were attempted in an outpatient setting; however, owing to pain and burning sensations experienced by the patients, the procedures failed to achieve the desired lengthening. Therefore, other procedures were performed with the patients under general anesthesia. We reviewed clinical data at index surgery for all 15 patients. We further analyzed the lengthening procedures, implant survival, radiographic and functional results, for the 10 long-term survivors. Functional results were assessed according to the MSTS scoring system. Complications were classified according to the International Society of Limb Salvage (ISOLS) classification system. RESULTS: Nine of the 10 survivors underwent revision of the implant for mechanical failure. They had a mean MSTS score of 64% (range, 47%-87%) before revision surgery. At final followup the 10 long-term surviving patients had an average MSTS score of 81% (range, 53%-97%). In total, we obtained an average lengthening of 39 mm per patient (range, 17-67 mm). Exact expansion of the implant was unpredictable and difficult to control. Nine of 10 of the long-term surviving patients underwent revision surgery of the prosthesis-eight for implant breakage and one for stem loosening. At revision surgery, six patients had another type of expandable prosthesis implanted and three had an adult-type megaprosthesis implanted. In five cases, segmental bone grafts were used during revision surgery to compensate for loss of bone stock. CONCLUSIONS: We could not comfortably expand the Repiphysis(®) prosthesis in an outpatient setting because of pain experienced by the patients during the lengthening procedures. Furthermore, use of the prosthesis was associated with frequent failures related to implant breakage and stem loosening. Revisions of these procedures were complex and difficult. We no longer use this prosthesis and caution others against the use of this particular prosthesis design. LEVEL OF EVIDENCE: Level IV, therapeutic study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Reconstruction of the distal femur after resection for malignant bone tumors in skeletally immature children is challenging. The use of megaprostheses has become increasingly popular in this patient group since the introduction of custom-made, expandable devices that do not require surgery for lengthening, such as the Repiphysis(®) Limb Salvage System. Early reports on the device were positive but more recently, a high complication rate and associated bone loss have been reported. QUESTIONS/PURPOSES: We asked: (1) what are the clinical outcomes using the Musculoskeletal Tumor Society (MSTS) scoring system after 5-year minimum followup in patients treated with this prosthesis at one center; (2) what are the problems and complications associated with the lengthening procedures of this implant; and (3) what are the specific concerns associated with revision of this implant? METHODS: At our institute, between 2002 and 2007, the Repiphysis(®) expandable prosthesis was implanted in 15 children (mean age, 8 years; range, 6-11 years) after distal femoral resection for malignant bone tumors. During this time, the general indication for use of this implant was resection of the distal femur for localized malignant bone tumors in pediatric patients. Alternative techniques used for this indication were modular prosthetic reconstruction, massive (osteoarticular or intercalary) allograft reconstruction, or rotationplasty. Age and tumor extension were the main factors to decide on the surgical indication. Of the 15 patients who had this prosthesis implanted during reconstruction surgery, five died with the implant in situ or underwent amputation before 5 years followup and the remaining 10 were evaluated at a minimum of 5 years (mean, 104 months; range, 78-140 months). No patients were lost to followup. These 10 patients were long-term survivors and underwent the lengthening program. They were included in our study analysis. The first seven lengthening procedures were attempted in an outpatient setting; however, owing to pain and burning sensations experienced by the patients, the procedures failed to achieve the desired lengthening. Therefore, other procedures were performed with the patients under general anesthesia. We reviewed clinical data at index surgery for all 15 patients. We further analyzed the lengthening procedures, implant survival, radiographic and functional results, for the 10 long-term survivors. Functional results were assessed according to the MSTS scoring system. Complications were classified according to the International Society of Limb Salvage (ISOLS) classification system. RESULTS: Nine of the 10 survivors underwent revision of the implant for mechanical failure. They had a mean MSTS score of 64% (range, 47%-87%) before revision surgery. At final followup the 10 long-term surviving patients had an average MSTS score of 81% (range, 53%-97%). In total, we obtained an average lengthening of 39 mm per patient (range, 17-67 mm). Exact expansion of the implant was unpredictable and difficult to control. Nine of 10 of the long-term surviving patients underwent revision surgery of the prosthesis-eight for implant breakage and one for stem loosening. At revision surgery, six patients had another type of expandable prosthesis implanted and three had an adult-type megaprosthesis implanted. In five cases, segmental bone grafts were used during revision surgery to compensate for loss of bone stock. CONCLUSIONS: We could not comfortably expand the Repiphysis(®) prosthesis in an outpatient setting because of pain experienced by the patients during the lengthening procedures. Furthermore, use of the prosthesis was associated with frequent failures related to implant breakage and stem loosening. Revisions of these procedures were complex and difficult. We no longer use this prosthesis and caution others against the use of this particular prosthesis design. LEVEL OF EVIDENCE: Level IV, therapeutic study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Growth rods are commonly used for the treatment of scoliosis in the immature spine. Many variations have been proposed but breakage of implants is a common problem. Growth rod insertion commonly involves large exposures at initial insertion followed by multiple smaller procedures for lengthening. We present our early experiences using a percutaneous technique of insertion of a new titanium mobile bearing implant (Medtronic Inc). The implant allows some rotatory motion in the middle of the construct thus reducing construct stresses and thus possibly reducing rod breakage risk. Based on this small initial series with 12 months follow-up, percutaneous insertion of growth rods using the new implant is a safe and reliable technique although the infection rate in our sample was of note. This may be related to the titanium wear and inflammation seen in the soft tissues at time of operation and visualised on histology. No implants have required removal due to infection, and all infections were treated with debridement at next lengthening and suppressive antibiotics. Propionibacterium is one of the commonest infections seen with spinal implants and sometimes does not respond to simple antibiotic suppression. The technique allows preservation of the soft tissues until definitive fusion is needed and may lead to a decrease in hospital stay. The implant is low profile and seems to offer advantages over other systems on the market. Further follow up is needed to look at longer term outcomes with this new implant type.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, natural palygorskite impregnated with zero-valent iron (ZVI) was prepared and characterised. The combination of ZVI particles on surface of fibrous palygorskite can help to overcome the disadvantage of ultra-fine powders which may have strong tendency to agglomerate into larger particles, resulting in an adverse effect on both effective surface area and catalyst performance. There is a significant increase of methylene blue (MB) decolourized efficiency on acid treated palygorskite with ZVI grafted, within 5 mins, the concentration of MB in the solution was decreased from 94 mg/L to around 20 mg/L and the equilibration was reached at about 30 to 60 mins with only around 10 mg/L MB remained in solution. Changes in the surface and structure of prepared materials were characterized using X-ray diffraction (XRD), infrared (IR) spectroscopy, surface analysing and scanning electron microscopy (SEM) with element analysis and mapping. Comparing with zero-valent iron and palygorskite, the presence of zero-valent iron reactive species on the palygorskite surface strongly increases the decolourization capacity for methylene blue, and it is significant for providing novel modified clay catalyst materials for the removal of organic contaminants from waste water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study established that the core principle underlying categorisation of activities have the potential to provide more comprehensive outcomes than the recognition of activities because it takes into consideration activities other than directional locomotion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study directly measured the load acting on the abutment of the osseointegrated implant system of transfemoral amputees during level walking, and studied the variability of the load within and among amputees. Twelve active transfemoral amputees (age: 54±12 years, mass:84.3±16.3 kg, height: 17.8±0.10 m) fitted with an osseointegrated implant for over 1 year participated in the study. The load applied on the abutment was measured during unimpeded, level walking in a straight line using a commercial six-channel transducer mounted between the abutment and the prosthetic knee. The pattern and the magnitude of the three-dimensional forces and moments were revealed. Results showed a low step-to-step variability of each subject, but a high subject-to-subject variability in local extrema of body-weight normalized forces and moments and impulse data. The high subject-to-subject variability suggests that the mechanical design of the implant system should be customized for each individual, or that a fit-all design should take into consideration the highest values of load within a broad range of amputees. It also suggests specific loading regime in rehabilitation training are necessary for a given subject. Thus the loading magnitude and variability demonstrated should be useful in designing an osseointegrated implant system better able to resist mechanical failure and in refining the rehabilitation protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current understanding of students’ group metacognition is limited. The research on metacognition has focused mainly on the individual student. The aim of this study was to address the void by developing a conceptual model to inform the use of scaffolds to facilitate group metacognition during mathematical problem solving in computer supported collaborative learning (CSCL) environments. An initial conceptual framework based on the literature from metacognition, cooperative learning, cooperative group metacognition, and computer supported collaborative learning was used to inform the study. In order to achieve the study aim, a design research methodology incorporating two cycles was used. The first cycle focused on the within-group metacognition for sixteen groups of primary school students working together around the computer; the second cycle included between-group metacognition for six groups of primary school students working together on the Knowledge Forum® CSCL environment. The study found that providing groups with group metacognitive scaffolds resulted in groups planning, monitoring, and evaluating the task and team aspects of their group work. The metacognitive scaffolds allowed students to focus on how their group was completing the problem-solving task and working together as a team. From these findings, a revised conceptual model to inform the use of scaffolds to facilitate group metacognition during mathematical problem solving in computer supported collaborative learning (CSCL) environments was generated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The buckling strength of a new cold-formed hollow flange channel section known as LiteSteel beam (LSB) is governed by lateral distortional buckling characterised by simultaneous lateral deflection, twist and web distortion for its intermediate spans. Recent research has developed a modified elastic lateral buckling moment equation to allow for lateral distortional buckling effects. However, it is limited to a uniform moment distribution condition that rarely exists in practice. Transverse loading introduces a non-uniform bending moment distribution, which is also often applied above or below the shear centre (load height). These loading conditions are known to have significant effects on the lateral buckling strength of beams. Many steel design codes have adopted equivalent uniform moment distribution and load height factors to allow for these effects. But they were derived mostly based on data for conventional hot-rolled, doubly symmetric I-beams subject to lateral torsional buckling. The moment distribution and load height effects of transverse loading for LSBs, and the suitability of the current design modification factors to accommodate these effects for LSBs is not known. This paper presents the details of a research study based on finite element analyses on the elastic lateral buckling strength of simply supported LSBs subject to transverse loading. It discusses the suitability of the current steel design code modification factors, and provides suitable recommendations for simply supported LSBs subject to transverse loading.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The flexural capacity of of a new cold-formed hollow flange channel section known as LiteSteel beam (LSB) is limited by lateral distortional buckling for intermediate spans, which is characterised by simultaneous lateral deflection, twist and web distortion. Recent research has developed suitable design rules for the member capacity of LSBs. However, they are limited to a uniform moment distribution that rarely exists in practice. Many steel design codes have adopted equivalent uniform moment distribution factors to accommodate the effect of non-uniform moment distributions in design. But they were derived mostly based on the data for conventional hot-rolled, doubly symmetric I-beams subject to lateral torsional buckling. The effect of moment distribution for LSBs, and the suitability of the current steel design code rules to include this effect for LSBs are not yet known. This paper presents the details of a research study based on finite element analyses of the lateral buckling strength of simply supported LSBs subject to moment gradient effects. It also presents the details of a number of LSB lateral buckling experiments undertaken to validate the results of finite element analyses. Finally, it discusses the suitability of the current design methods, and provides design recommendations for simply supported LSBs subject to moment gradient effects.