785 resultados para high-intensity exercise
Resumo:
Advances in optical techniques have enabled many breakthroughs in biology and medicine. However, light scattering by biological tissues remains a great obstacle, restricting the use of optical methods to thin ex vivo sections or superficial layers in vivo. In this thesis, we present two related methods that overcome the optical depth limit—digital time reversal of ultrasound encoded light (digital TRUE) and time reversal of variance-encoded light (TROVE). These two techniques share the same principle of using acousto-optic beacons for time reversal optical focusing within highly scattering media, like biological tissues. Ultrasound, unlike light, is not significantly scattered in soft biological tissues, allowing for ultrasound focusing. In addition, a fraction of the scattered optical wavefront that passes through the ultrasound focus gets frequency-shifted via the acousto-optic effect, essentially creating a virtual source of frequency-shifted light within the tissue. The scattered ultrasound-tagged wavefront can be selectively measured outside the tissue and time-reversed to converge at the location of the ultrasound focus, enabling optical focusing within deep tissues. In digital TRUE, we time reverse ultrasound-tagged light with an optoelectronic time reversal device (the digital optical phase conjugate mirror, DOPC). The use of the DOPC enables high optical gain, allowing for high intensity optical focusing and focal fluorescence imaging in thick tissues at a lateral resolution of 36 µm by 52 µm. The resolution of the TRUE approach is fundamentally limited to that of the wavelength of ultrasound. The ultrasound focus (~ tens of microns wide) usually contains hundreds to thousands of optical modes, such that the scattered wavefront measured is a linear combination of the contributions of all these optical modes. In TROVE, we make use of our ability to digitally record, analyze and manipulate the scattered wavefront to demix the contributions of these spatial modes using variance encoding. In essence, we encode each spatial mode inside the scattering sample with a unique variance, allowing us to computationally derive the time reversal wavefront that corresponds to a single optical mode. In doing so, we uncouple the system resolution from the size of the ultrasound focus, demonstrating optical focusing and imaging between highly diffusing samples at an unprecedented, speckle-scale lateral resolution of ~ 5 µm. Our methods open up the possibility of fully exploiting the prowess and versatility of biomedical optics in deep tissues.
Resumo:
A study on the interactions of high intensity (similar to 10(16) W/cm(2)) femtosecond laser pulses with rare gas clusters in a dense jet is performed. Energy absorption by Ar and Xe clusters is measured and it can be as high as 90%. Very energetic ions produced in the laser interaction with a dense cluster jet are detected by time-of-flight spectrometry and the maximum ion energy of Xe is up to 1.3 MeV. The average ion energies are found to increase with increasing cluster size and get saturated gradually. The average ion energies also show a strong directionality and the average ion energy in the direction parallel to the laser polarization vector is 40% higher than that perpendicular to it. The findings are discussed in terms of a model of charge-dependent ion acceleration.
Resumo:
Particle-in-cell simulations are performed to study the acceleration of ions due to the interaction of a relativistic femtosecond laser pulse with a narrow thin target. The numerical results show that ions can be accelerated in a cascade by two electrostatic fields if the width of the target is smaller than the laser beam waist. The first field is formed in front of the target by the central part of the laser beam, which pushes the electron layer inward. The major part of the abaxial laser energy propagates along the edges to the rear side of the target and pulls out some hot electrons from the edges of the target, which form another electrostatic field at the rear side of the target. The ions from the front surface are accelerated stepwise by these two electrostatic fields to high energies at the rear side of the target. The simulations show that the largest ion energy gain for a narrow target is about four times higher than in the case of a wide target. (c) 2006 American Institute of Physics.
Resumo:
利用高重复频率(1kHz)、吉瓦级飞秒激光脉冲实验验证了高强度飞秒脉冲在空气中的自压缩现象,研究了入射脉冲在不同初始啁啾情况下经空气中聚焦成丝后,时域及频域特性随入射脉冲能量的变化规律.实验结果表明,在无需后继色散补偿情况下,高强度飞秒脉冲仅通过在空气中的非线性传输过程就可以实现脉冲压缩;在入射脉冲为负啁啾情况下,实验观察到脉冲光谱及时域宽度同时得到压缩,并可获得比激光源所能提供的更短的近双曲正割型变换限脉冲.
Resumo:
高强度飞秒激光脉冲的腔外压缩是获得高次谐波阿秒脉冲驱动源的必要手段。实验研究了超强超短飞秒激光脉冲在经过块状介质后的光谱展宽和色散补偿压缩现象。单脉冲能量0.26mJ,脉宽50fs的激光脉冲经透镜在空气中聚焦后再入射到块状材料上,出射脉冲光谱被展宽到接近40nm。由于在块状材料中的自聚焦效应,出射光束质量变好并保持较小的空间啁啾。利用熔融石英棱镜对补偿带有正色散的出射脉冲,最后得到〉0.1mJ,19fs的压缩脉冲。利用SPIDER装置测量了出射脉冲的脉宽和光谱相位。整个系统的能量效率大约为35%,压缩后的
Resumo:
应用电子汤姆孙散射的经典理论,通过理论分析和计算机模拟,研究了超短超强激光脉冲作用下电子产生的辐射脉冲的性质.计算表明,在这种情况下,电子的辐射通常以阿秒脉冲列的形式出现.讨沦了不同激光场参数(包括激光强度、脉宽、初相位和偏振态)、不同电子初始状态(初始速度和位置)对辐射脉冲的时间和空间特性的影响.通常在相对论光强条件下,激光强度越大,电子辐射越强,脉宽越窄,中心频率越大,并且方向性越好;电子在线偏振激光中产生的辐射效率,比在同样强度下圆偏振激光中产生的效率更高;无论入射光是线偏振光,还是圆偏振光,辐射场
Resumo:
By using a one-dimensional self-consistent relativistic fluid model, an investigation is made numerically on relativistic electromagnetic solitons with a high intensity in cold overdense plasmas with an electrons' initial velocity opposite to the laser propagating direction. Two types of standing solitons with zero group velocity are found at the given electrons' initial velocities. One is single-humped with a weakly relativistic intensity; the another is multi-humped with a strong relativistic amplitude. The properties of these two types of solitons are presented in detail.
Resumo:
Microwave noise emission at the harmonics of the electron cyclotron frequency from the magnetized plasma column of a Penning discharge is investigated experimentally. The harmonic emission spectrum is observed using oxygen gas in a variety of discharge configurations. It is found that grid stabilization of the plasma column has very little effect on the emission spectrum. Measurements of the shape and location of the harmonic emission lines are described in detail. On the basis of a microwave interferometer measurement of the electron density, it is concluded that the existence of a hybrid layer somewhere on the plasma column is a necessary condition for the observation of harmonic emission. The relaxation time and the cathode voltage dependence of the harmonic emission are investigated using a pulse modulation technique. It is found that the emission intensity increases rapidly with the magnitude of the cathode voltage and that the relaxation time decreases with increasing neutral gas pressure. High intensity nonharmonic radiation is observed and identified as resulting from a beam-plasma wave instability thereby eliminating the same instability as a possible source of the harmonic emission. It is found that the collective experimental results are in reasonable agreement with the single particle electrostatic radiation theory of Canobbio and Croci.
Resumo:
Charged pion pair photoproduction has been investigated up to a gamma energy of 1500 MeV, using the Caltech 12-inch heavy liquid bubble chamber with a small diameter, high intensity photon beam passing through a central beam tube gaseous hydrogen target surrounded by the sensitive Freon. Scanning, analysis, and data reduction techniques have been developed to deal with the problems of two-vie stereo, hidden event origins, absence of magnetic field, and the range-energy and multiple scattering relationships that occur in the heavy materials. Roughly 5700 pictures have been scanned and analyzed, yielding 754 acceptable events. Cross section and parameter distributions are generally consistent with the results of previous experiments. A statistically insignificant “bump” was observed in the dipion mass spectrum in the region of 500 MeV, the disputed σ meson mass. This region was investigated as carefully as the limited statistics would allow; dipion angular distributions are consistent with isotropy, and there is indication that some of the events in this region might come from decay of an intermediate N*11 (1425) into a proton and dipion.
Photographic materials on pp. 18, 20, 22, and 24 are essential and will not reproduce clearly on Xerox copies. Photographic copies should be ordered.
Resumo:
O presente estudo teve como objetivo avaliar a influência da variação da intensidade de luz, para uma mesma exposição radiante, na resistência à flexão, na microdureza e na resistência à tração diametral de uma resina convencional e de uma resina de baixa contração. Para a confecção dos corpos de prova foram utilizadas as resinas Filtek Z250 (3M ESPE) e Filtek P90 LS (3M ESPE) fotoativadas por meio dos seguintes protocolos: Convencional (400mW/cm por 60 s), Média intensidade (700mW/cm por 34 s) e Alta intensidade (950mW/cm por 26 s). Todos os corpos de prova receberam a mesma exposição radiante de 24J/cm. A resistência à flexão foi avaliada por meio do ensaio de flexão três pontos. Para este ensaio foram confeccionados trinta corpos de prova de cada material (n=10) com dimensões de 10mm x 2mm x 1mm. A avaliação da microdureza Knoop foi obtida a partir de seis discos de cada resina com 5mm de diâmetro por 2mm de espessura (n=2), sendo realizadas cinco indentações em cada espécime. Trinta corpos de prova cílindricos de cada compósito (n=10) com 3mm de diâmetro por 6mm de altura foram confeccionados para a realização do teste de tração diametral. A análise estatística dos resultados obtidos foi realizada por meio do teste de análise de variância (ANOVA) e do teste de múltiplas comparações de Tukey (p < 0.05). A resistência à flexão da resina P90 não foi influenciada de forma significativa pelas diferentes formas de ativação, enquanto a Z250 obteve resultados significantemente maiores para o protocolo de alta intensidade em relação ao convencional. Em todas as intensidades de luz, os resultados da Z250 foram significativamente maiores que os da P90. A microdureza da resina P90 foi estatisticamente maior para o grupo de média intensidade em relação aos outros, já a Z250 não obteve resultados com diferença estatística em relação às formas de ativação. Para a mesma irradiância, a Z250 obteve maiores valores de microdureza do que a P90, com exceção para o protocolo de média intensidade em que não houve diferença estatística entre os materiais. Os valores de resistência à tração não foram influenciados de forma significativa nem pelas diferentes intensidades de luz, nem pelos materiais utilizados. A influência da variação da intensidade de luz depende do tipo de compósito utilizado e da propriedade mecânica avaliada.
Resumo:
制备了不同氟化物含量的(1-x)TeO2-AlF3(x=10%,20%,30%,按摩尔计)透明氟碲酸盐玻璃。利用差热分析和Raman光谱对玻璃的性质和结构进行研究。结果显示:当x达到30%时,氟化铝以Al-F多面体的形式进入玻璃网络结构。随着氟化物含量增加,玻璃在中红外区的透过率提高,玻璃结构单元从[Te(O,F)4]三方双锥向[Te(O,F)3]三方锥转变。Raman光谱显示:1个宽的强峰出现在750~840cm^-1,表明玻璃中Te-O键长介于0.185-0.196nm之间。
Resumo:
[EUS] Ikerketa honen helburua futbol partiduen eta entrenatzeko erabiltzen diren joko murriztuen arteko bihotz maiztasunean oinarritutako intentsitateen arteko konparazioa egitea zen, horrela joko errealarekin antz handiena zuen joko murriztua zein zen determinatzeko. Hemeretzi jokalari erdi profesional (18,74 ± 1,24-ko adina, 72,49 ± 4,72-ko pisua, 1,80 ± 0,05-ko altuera) parte hartu zuten aurre denboraldiko lau partidu hiru joko murriztu ezberdinekin, SSG4, SSG7 eta SSGPG, konparatu zituen ikerketan. Bihotz maiztasun maximoa (BMmax), bataz besteko bihotz maiztasuna (BMbb) eta 5 intentsitate zonalde ezberdinetan egondako denbora neurtu ziten lau partidu eta joko murriztu bakoitzeko hiru saiotan eta ezberdintasun esanguratsuak aurkitu ziren partiduen eta joko murriztu guztien artean BMmax eta BMbb baloreetan, SSG7an izan ezik, zeinen BMbb partiduetan erregistratuarenaren antzekoa izan zen. Joko murriztuen artean ere ezberdintasunak aurkitu ziren, haien denen artean SSG7 intentsuena izan zelarik. Intentsitate zonaldeen kasuan partiduak eta SSG7 beste jokoak baino intentsuagoak zirela iruditu zuten, jokalariak joko hauetan intentsitate altuko zonaldeetan egondako denbora tarte luzeagoengatik.
Resumo:
Because dolphins sometimes travel with yellowfin tuna, Thunnus albacares, in the eastern tropical Pacific (ETP), purse seiners use the dolphins to locate and capture tuna schools. During the process of setting the purse seine nets, dolphins often become entangled and drown before they can be released. Data for the U.S. purse seine fleet in the ETP during 1979-88 show that dolphin mortality rates in sets made during the night are higher than mortality rates in sets made during the day. Even with efforts to reduce nightset mortality rates through the use of high intensity floodlights, night set mortality rates remain higher. The data are also used to simulate a regulation on the fishery aimed at eliminating night sets and show that dolphin mortality rates would decrease.
Resumo:
Distribution of the marine life in relation to the extent of pollution at and outside Mahim Bay was studied. A poor marine fauna at stations A and B was associated with a relatively high intensity of pollution accompanied by high BOD and nutrients and low DO levels. A distinct deterioration in the marine life and water quality along the northern part of the bay as compared to the southern part was evident. An increasing trend in the marine fauna with decreasing intensity of pollution from inside to outside the bay was noticed.
Resumo:
There is a growing need for very small nuclear reactors for space applications and as portable high-intensity neutron sources. This technical note investigates the question of what is the smallest possible thermal reactor. It was found that the smallest reactor is a spherically shaped solution of 242mAm(NO3)3 in water. The weight of such a reactor is 4.95 kg with 0.7 kg of 242mAm nuclear fuel. The radius of the reactor in this case is 9.6 cm.