999 resultados para guías clínicas informatizadas


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Integração dos Sistemas de Informação em Radiologia (RIS - "Radiology Information System") e de Arquivamento e Comunicação de Imagens (PACS - "Picture Archiving and Communication System") no Serviço de Radiodiagnóstico do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo, para possibilitar a consulta remota de laudos e imagens associadas. MATERIAIS E MÉTODOS: A integração RIS/PACS implementada é feita em tempo real, no momento da consulta, utilizando tecnologias "web" e técnicas de programação para "intranet/internet". RESULTADOS: A aplicação "web" permite a consulta pela "intranet" do hospital dos laudos de exames e imagens associadas através de nome, sobrenome, número de registro hospitalar dos pacientes ou por modalidade, dentro de um determinado período. O visualizador possibilita que o usuário navegue pelas imagens, podendo realizar algumas funções básicas como "zoom", controle de brilho e contraste e visualização de imagens lado a lado. CONCLUSÃO: A integração RIS/PACS diminui o risco de inconsistências, através da redução do número de interfaces entre bases de dados com grande redundância de informação, proporcionando um ambiente de trabalho rápido e seguro para consulta de laudos radiológicos e visualização de imagens associadas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Novas técnicas de exames têm sido desenvolvidas com o objetivo de se obter não apenas uma avaliação estrutural, mas também uma análise funcional e metabólica de diversos órgãos e tipos de lesões. Entre estas ferramentas, a perfusão por tomografia computadorizada (PTC) tem despertado o interesse de muitos pesquisadores em estudar a sua aplicabilidade em órgãos e doenças abdominais. Entre estas aplicações podemos citar a avaliação do comportamento biológico de tecidos sadios e doentes, a diferenciação de processos inflamatórios de tumorais e o diagnóstico da recidiva tumoral após terapêuticas minimamente invasivas. A principal característica da PTC reside na sua capacidade de caracterizar comportamentos perfusionais distintos e que traduzem alterações biológicas de determinadas lesões e tecidos doentes. Dessa forma, o nosso objetivo foi realizar uma ampla revisão da literatura, mostrando as principais técnicas e protocolos utilizados nos exames de PTC, as principais indicações, vantagens e desvantagens do método, além de propor um protocolo de exame que possa ser introduzido na rede privada e pública de saúde, com reprodutibilidade e simplicidade de implementação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Los estudiantes de medicina efectúan una parte de sus rotaciones en entornos como salas de hospitalización, consultas externas y centros de salud, donde comparten las experiencias clínicas con un médico al que llamaremos"tutor". La reforma de los planes docentes abordados por las facultades de medicina pone el acento en este tipo de prácticas [1,2]. El presente trabajo se enmarca en un esfuerzo de la Facultad de Medicina de la Universitat de Barcelona para hacer presente las habilidades de comunicación en la tarea docente [3,4], e indica algunas pautas para la recepción y acomodación de estos estudiantes, así como situaciones delicadas que deben ser resueltas con asertividad...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar aspectos ultrassonográficos associados à morbidade em pacientes com formas clínicas crônicas de esquistossomose mansônica, utilizando-se protocolo proposto pela Organização Mundial da Saúde (OMS). MATERIAIS E MÉTODOS: Foram avaliadas duas populações distintas: a) área endêmica e b) institucional terciária, com histopatológico confirmando fibrose. Critérios de inclusão: diagnóstico confirmado por parasitológico de fezes para Schistosoma mansoni (método Kato-Katz). Critérios de exclusão: sorologia positiva para HIV, HTLV-1, VHB ou VHC. Foi utilizado protocolo ultrassonográfico de Niamey, proposto pela OMS. RESULTADOS: Avaliando-se isoladamente as medidas dos espaços periportais, estas se mostraram sem alterações em 21% dos indivíduos com doença avançada da instituição terciária. Utilizando-se todos os parâmetros do protocolo, 100% dos indivíduos da instituição terciária, com forma grave da doença, apresentaram fibrose periportal avançada. Em pacientes hepatoesplênicos da área endêmica não se identificou fibrose à ultrassonografia. CONCLUSÃO: O protocolo ultrassonográfico proposto pela OMS detecta fibrose periportal avançada nos pacientes com forma grave da doença, com maior sensibilidade do que a medida do espaço periportal isoladamente. A complexidade de identificação das fases iniciais da fibrose periportal, em áreas endêmicas, pela ultrassonografia, pode suscitar o campo da complementação diagnóstica e a continuidade do aprimoramento dos protocolos ultrassonográficos nestas áreas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The construction and evaluation of an inexpensive flow photometer for clinical analysis, using a bicolour LED and a phototransistor adapted for tubular flow cell, are described. The instrument presents some new features such as: automatic zero, electronic calibration and peak-hold signal. When compared with a classical photometer, it is simpler and has the advantages of a flow analysis system: lower volumes of reagents and samples, lower levels of contamination, shorter time for analysis and lower analysis costs. The instrument was used in the determination of the constituents in blood samples. The results obtained agree with those obtained by a classical photometer and the precision was better.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twenty domestic commercial filters, in order to determine the percentual retention of color, turbidity, dry residue, bicarbonates, carbonates, total hardness, nitrogens, iron, chlorides, fluorides, and residual chlorine (parameters of food legislation) and sulphides in thirteen water samples proceeding from springs, wells, rivers, lakes, drinking patterns and standards, before and after purification were evaluated. The results showed that purifiers presented adequate retention for nitrates (74.8 ± 16.2 %) and residual chlorine (74.0 ± 11.2) and medium retention for sulphides (61.7 ± 11.3); while porcelain plus activated carbon filters presented adequate retention for color (90.0 ± 19.7), turbidity (76.4 ± 18.4) and iron (83.5 ± 15.1). Therefore the retention of carbonates, bicarbonates, total hardness, chlorides, dry residue, fluorides, ammonium nitrogens and nitrites was less than 10%, and the values of pH didn't show significant variation, for all the filters studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow system based on multicommutation and binary sampling process was developed to implement the sample zone trapping technique in order to increase the spectrophotometric analytical range and to improve sensitivity. The flow network was designed with active devices in order to provide facilities to determine sequentialy analyte with a wide concentration range, employing a single pumping channel to propel sample and reagents solutions. The procedure was employed to determine ortophosphate ions in water samples of river and waste. Profitable features such as an analytical throughput of 60 samples determination per hour, relative standard deviation (r.s.d.) of 2% (n = 6) for a typical sample with concentration of 2.78 mg/L were achieved. By applying the paired t-test no significant difference at 95% confidence level was observed between the results obtained with the proposed system and those of the usual flow injection system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The multi-element determination of Al, Cr, Mn, Ni, Cu, Zn, Cd, Ba, Pb, SO4= and Cl- in riverine water samples was accomplished by inductively coupled plasma mass spectrometry (ICP-MS). The sample passed through a column containing the anionic resin AG1-X8 and the metals were determined directly. The retained anionic species were eluted and SO4= and Cl- were determined at m/z 48 and 35 correspondent to the ions SO+ and Cl+ formed at the plasma. Accuracy for metals was assessed by analysing the certified reference TM-26 (National Water Research Institute of Canada). Results for SO4= and Cl- were in agreement with those obtained by turbidimetry and spectrophotometry. LOD's of 0.1 µg l-1 for Cd, Ba and Pb; 0.2 µg l-1 for Al, Mn and Cu; 0.5 µg l-1 for Cr; 0.9 for Zn; 2.0 µg l-1for Ni , 60 µg l-1 for S and 200 µg l-1 Cl were attained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The input of heavy metals concentrations determinated by ICP-AES, in samples of the Cambé river basin, was evaluated by using the Principal Component Analysis. The results distinguishes clearly one site, which is strongly influenced by almost all elements studied. Special attention was given to Pb, because of the presence of one battery industry in this area. Some downstream samples were associated with the same characteristics of this site, showing residual action of contaminants along the basin. Other sites presented influence of soil elements, plus Cr near a tannery industry. This study allowed to distinguish different sites in the upper basin of the Cambé (Londrina-PR-BR), in accordance to elements input.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Results on the optimization of analytical methods for the determination of phosphorus in phosphino-polycarboxylate (PPCA), used frequently as scale inhibitor during oil production, by ICP-AES and ICP-MS are presented. Due to the complex matrix of production waters (brines) and their high concentration in inorganic phosphorus, the separation of organic phosphorus prior to its determination is necessary. In this work, minicolumns of silica immobilized C18 were used. Optimization of the separation step resulted in the following working conditions: (1) prewashing of the column with methanol (80% v/v); (2) use of a flow rate of 5 mL/min and 10 mL/min, respectively, for the preconditioning step and for percolation of the water sample; (3) final elution of organic phosphorus with 7 mL of buffer of H3BO3/NaOH (0.05 M, pH 9) with a flow rate of 1 mL/min. Sample detection limits (3s) for different combinations of nebulizers and spectrometric methods, based on 10 mL water aliquots, are: ICP-AES -Cross flow (47 mg/L) and Ultrasonic (18 mug/L); ICP-MS -Cross flow (1.2 mug/L), Cyclonic (0.7 mug/L) and Ultrasonic (0.5 mug/L). Typical recoveries of organic phosphorus are between 90 and 95% and the repeatability of the whole procedure is better than 10%. The developed methodology was applied successfully to samples from the oil-well NA 46, platform PNA 2, Campos basin, Brazil. Assessment of the PPCA inhibitor was possible at lower concentrations than achieved by current analytical methods, resulting in benefits such as reduced cost of chemicals, postponed oil production and lower environmental impacts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The technique of solid phase microextraction (SPME) was used for the extraction of halogenated contaminants of water samples from three cities of the State of São Paulo and the extracts were submitted to gas chromatographic analysis with electron capture detection (GC-ECD). In the samples of water collected at the city of São Paulo the detected level of trihalomethanes (THM) expressed as the sum of chloroform, dibromochloromethane and dichlorobromomethane, were higher than the permissible limit established by the Brazilian regulation. In the samples collected at the two other cities the level of any of the three THM remained below the sensitivity of the ECD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to evaluate the chromium contamination from tannery discharges into rivers in the State of Minas Gerais, samples of water and suspended material were collected and submitted to chemical analysis. The total content of chromium in the samples was measured by flame atomic absorption spectrophotometry. Water samples were analysed by standard addition method, while chromium concentration in suspended materials was determined by calibration curves. Localities investigated were Ipatinga, Matias Barbosa, Dores de Campo, Ressaquinha, Ubá and Juiz de Fora. Samples from a not-industrialized area were also analysed to obtain regional background values. Metal inputs were related to effluent discharges into the rivers. Suspended material transported Cr downriver. Chromium concentration in river water exceeded 656 times the value of the Brazilian Environmental Standards, while its concentration in suspended material ranged from 15 to 11066 µg g-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work the contamination, by organochlorinated, of a drinking water source located in the region of Viçosa, MG, was evaluated. The identification and quantification of the analytes was carried out using a gas-chromatograph equipped with an electron capture detector after liquid-liquid extraction and concentration. Four insecticides, Aldrin, Epoxy heptachloride, Endrin and op'- DDT were detected in concentrations that are higher than the safety limits established in the Brazilian legislation.