1000 resultados para Water-meters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proceedings of tile 1" R.C.A.N.S. Congress, Lisboa, October 1992

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Moncorvo Ordovician ironstones in northeastern Portugal consist of iron ore sedimentary horizons frequently interbanded with psamites and quartzites. Ore reserves may probably exceed 1 000 million tonnes and this makes Moncorvo the largest iron ore deposit in the European Union. Compact poorly banded massive layers may exceed 90 meters in thickness which is quite an extraordinary feature for a Phanerozoic deposit. If the thickness of Precambrian deposits may reach a few hundred meters, the thickness of Phanerozoic deposits never exceed a maximum of 15 meters generally forming a number of comparatively thin layers confined to a particular member of a sedimentary sequence. A detailed microscopic analysis of the ores revealed that initially a compact magnetite/quartzite layer, detrital in character (the magnetite occasionally showing chromite cores), was deposited by entrapment in near shore lagoons where rivers debouched, rather than in the open sea. This stage was followed by oscilating and transgressive shore lines which gave rise to breaks in sedimentation in combined river delta and shallow water marine environment where detrital material and fine iron oxide and clay suspensions were deposited in fluctuating environments. These events gave rise to layers of both magnetite (martite) and specularite intergrown with quartz, silicates and phosphates. Textural and mineralogical studies show that the deposits consist of ferruginous clastic sediments and are not chemically deposited cherts. Field, geological and palaeontological evidence also supports a detrital origin, the facies being typical of zones rich in oxygen and close to the feeding continent. The uncommon huge development of Moncorvo was due to the fact that the deposits occur in restricted basins on a continental platform were clastic sediments were predominantly deposited. Not only morphologically but also chemically the deposits are more similar to Precambrian iron formations than to Phanerozoic ironstones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trihalomethanes (THMs) are widely referred and studied as disinfection by-products (DBPs). The THMs that are most commonly detected are chloroform (TCM), bromodichloromethane (BDCM), chlorodibromomethane (CDBM), and bromoform (TBM). Several studies regarding the determination of THMs in swimming pool water and air samples have been published. This paper reviews the most recent work in this field, with a special focus on water and air sampling, sample preparation and analytical determination methods. An experimental study has been developed in order to optimize the headspace solid-phasemicroextraction (HS-SPME) conditions of TCM, BDCM, CDBM and TBM from water samples using a 23 factorial design. An extraction temperature of 45 °C, for 25min, and a desorption time of 5 min were found to be the best conditions. Analysis was performed by gas chromatography with an electron capture detector (GC-ECD). The method was successfully applied to a set of 27 swimming pool water samples collected in the Oporto area (Portugal). TCM was the only THM detected with levels between 4.5 and 406.5 μg L−1. Four of the samples exceeded the guideline value for total THMs in swimming pool water (100 μgL−1) indicated by the Portuguese Health Authority.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to optimize the water quality monitoring of a polluted watercourse (Leça River, Portugal) through the principal component analysis (PCA) and cluster analysis (CA). These statistical methodologies were applied to physicochemical, bacteriological and ecotoxicological data (with the marine bacterium Vibrio fischeri and the green alga Chlorella vulgaris) obtained with the analysis of water samples monthly collected at seven monitoring sites and during five campaigns (February, May, June, August, and September 2006). The results of some variables were assigned to water quality classes according to national guidelines. Chemical and bacteriological quality data led to classify Leça River water quality as “bad” or “very bad”. PCA and CA identified monitoring sites with similar pollution pattern, giving to site 1 (located in the upstream stretch of the river) a distinct feature from all other sampling sites downstream. Ecotoxicity results corroborated this classification thus revealing differences in space and time. The present study includes not only physical, chemical and bacteriological but also ecotoxicological parameters, which broadens new perspectives in river water characterization. Moreover, the application of PCA and CA is very useful to optimize water quality monitoring networks, defining the minimum number of sites and their location. Thus, these tools can support appropriate management decisions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes preliminary work on the generation of synthesis gas from water electrolysis using graphite electrodes without the separation of the generated gases. This is an innovative process, that has no similar work been done earlier. Preliminary tests allowed to establish correlations between the applied current to the electrolyser and flow rate and composition of the generated syngas, as well as a characterisation of generated carbon nanoparticles. The obtained syngas can further be used to produce synthetic liquid fuels, for example, methane, methanol or DME (dimethyl ether) in a catalytic reactor, in further stages of a present ongoing project, using the ELECTROFUEL® concept. The main competitive advantage of this project lies in the built-in of an innovative technology product, from RE (renewable energy) power in remote locations, for example, islands, villages in mountains as an alternative for energy storage for mobility constraints.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the concentration probability distributions of 82 pharmaceutical compounds detected in the effluents of 179 European wastewater treatment plants were computed and inserted into a multimedia fate model. The comparative ecotoxicological impact of the direct emission of these compounds from wastewater treatment plants on freshwater ecosystems, based on a potentially affected fraction (PAF) of species approach, was assessed to rank compounds based on priority. As many pharmaceuticals are acids or bases, the multimedia fate model accounts for regressions to estimate pH-dependent fate parameters. An uncertainty analysis was performed by means of Monte Carlo analysis, which included the uncertainty of fate and ecotoxicity model input variables, as well as the spatial variability of landscape characteristics on the European continental scale. Several pharmaceutical compounds were identified as being of greatest concern, including 7 analgesics/anti-inflammatories, 3 β-blockers, 3 psychiatric drugs, and 1 each of 6 other therapeutic classes. The fate and impact modelling relied extensively on estimated data, given that most of these compounds have little or no experimental fate or ecotoxicity data available, as well as a limited reported occurrence in effluents. The contribution of estimated model input variables to the variance of freshwater ecotoxicity impact, as well as the lack of experimental abiotic degradation data for most compounds, helped in establishing priorities for further testing. Generally, the effluent concentration and the ecotoxicity effect factor were the model input variables with the most significant effect on the uncertainty of output results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since long ago cellulosic lyotropic liquid crystals were thought as potential materials to produce fibers competitive with spidersilk or Kevlar, yet the processing of high modulus materials from cellulose-based precursors was hampered by their complex rheological behavior. In this work, by using the Rheo-NMR technique, which combines deuterium NMR with rheology, we investigate the high shear rate regimes that may be of interest to the industrial processing of these materials. Whereas the low shear rate regimes were already investigated by this technique in different works [1-4], the high shear rates range is still lacking a detailed study. This work focuses on the orientational order in the system both under shear and subsequent relaxation process arising after shear cessation through the analysis of deuterium spectra from the deuterated solvent water. At the analyzed shear rates the cholesteric order is suppressed and a flow-aligned nematic is observed which for the higher shear rates develops after certain time periodic perturbations that transiently annihilate the order in the system. During relaxation the flow aligned nematic starts losing order due to the onset of the cholesteric helices leading to a period of very low order where cholesteric helices with different orientations are forming from the aligned nematic, followed in the final stage by an increase in order at long relaxation times corresponding to the development of aligned cholesteric domains. This study sheds light on the complex rheological behavior of chiral nematic cellulose-based systems and opens ways to improve its processing. (C) 2015 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Master Thesis to obtain the Master degree in Chemical Engineering - Branch Chemical Processes

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an optimization study of a distillation column for methanol and aqueous glycerol separation in a biodiesel production plant. Considering the available physical data of the column configuration, a steady state model was built for the column using Aspen-HYSYS as process simulator. Several sensitivity analysis were performed in order to better understand the relation between the variables of the distillation process. With the information obtained by the simulator, it is possible to define the best range for some operational variables that maintain composition of the desired product under specifications and choose operational conditions to minimize energy consumptions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fourteen year schistosomiasis control program in Peri-Peri (Capim Branco, MG) reduced prevalence from 43.5 to 4.4%; incidence from 19.0 to 2.9%, the geometric mean of the number of eggs from 281 to 87 and the level of the hepatoesplenic form cases from 5.9 to 0.0%. In 1991, three years after the interruption of the program, the prevalence had risen to 19.6%. The district consists of Barbosa (a rural area) and Peri-Peri itself (an urban area). In 1991, the prevalence in the two areas was 28.4% and 16.0% respectively. A multivariate analysis of risk factors for schistosomiasis indicated the domestic agricultural activity with population attributive risk (PAR) of 29.82%, the distance (< 10 m) from home to water source (PAR = 25.93%) and weekly fishing (PAR = 17.21%) as being responsible for infections in the rural area. The recommended control measures for this area are non-manual irrigation and removal of homes to more than ten meters from irrigation ditches. In the urban area, it was observed that swimming at weekly intervals (PAR = 20.71%), daily domestic agricultural activity (PAR = 4.07%) and the absence of drinking water in the home (PAR=4.29%) were responsible for infections. Thus, in the urban area the recommended control measures are the substitution of manual irrigation with an irrigation method that avoids contact with water, the creation of leisure options of the population and the provision of a domestic water supply. The authors call attention to the need for the efficacy of multivariate analysis of risk factors to be evaluated for schistosomiasis prior to its large scale use as a indicator of the control measures to be implemented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted to obtain a Ph.D. (Doutoramento) degree in Biology at the Instituto de Tecnologia Química e Biológica da Universidade Nova de Lisboa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do Grau de Doutor em Ambiente pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Schistosomiasis mansoni in the Serrano village, municipality of Cururupu, state of Maranhão, Brazil, is a widely spread disease. The PECE (Program for the Control of Schistosomiasis), undertaken since 1979 has reduced the prevalence of S. mansoni infection and the hepatosplenic form of the disease. Nevertheless piped water is available in 84% of the households, prevalence remains above 20%. In order to identify other risk factors responsible for the persistence of high prevalence levels, a cross-sectional survey was carried out in a systematic sample of 294 people of varying ages. Socioeconomic, environmental and demographic variables, and water contact patterns were investigated. Fecal samples were collected and analyzed by the Kato-Katz technique. Prevalence of S. mansoni infection was 24.1%, higher among males (35.5%) and between 10-19 years of age (36.6%). The risk factors identified in the univariable analysis were water contacts for vegetable extraction (Risk Ratio - RR = 2.92), crossing streams (RR = 2.55), bathing (RR = 2.35), fishing (RR = 2.19), hunting (RR = 2.17), cattle breeding (RR = 2.04), manioc culture (RR = 1.90) and leisure (RR = 1.56). After controlling for confounding variables by proportional hazards model the risks remained higher for males, vegetable extraction, bathing in rivers and water contact in rivers or in periodically inundated parts of riverine woodland (swamplands)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gradually smart grids and smart meters are closer to the home consumers. Several countries has developed studies focused in the impacts arising from the introduction of these technologies and one of the main advantages are related to energy efficiency, observed through the awareness of the population on behalf of a more efficient consumption. These benefits are felt directly by consumers through the savings on electricity bills and also by the concessionaires through the minimization of losses in transmission and distribution, system stability, smaller loading during peak hours, among others. In this article two projects that demonstrate the potential energy savings through smart meters and smart grids are presented. The first performed in Korea, focusing on the installation of smart meters and the impact of use of user interfaces. The second performed in Portugal, focusing on the control of loads in a residence with distributed generation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nesta dissertação pretendeu-se estudar a viabilidade do uso de eletrodiálise com membranas bipolares (BM) na recuperação de ácido clorídrico e de hidróxido de sódio a partir de um efluente industrial que contém 1.4 mol/L de cloreto de sódio. Estas membranas mostraram ser uma ferramenta eficiente para a produção de ácidos e bases a partir do respetivo sal. Foi feita uma seleção de diferentes membranas bipolares (Neosepta, Fumatech e PCA) e aniónicas (PC-SA e PC-ACID 60) na tentativa de encontrar a combinação mais adequada para o tratamento do efluente. Dependendo do critério, o melhor arranjo de membranas é o uso de PC-ACID 60 (membrana aniónica), PC-SK (membrana catiónica) e membranas bipolares do tipo Neosepta para maior pureza dos produtos; membranas bipolares Fumatech para maior eficiência de dessalinização e membranas bipolares PCA para um maior grau de dessalinização. Tecnologicamente foi possível obter uma dessalinização de 99.8% em quatro horas de funcionamento em modo batch com recirculação de todas as correntes. Independentemente da combinação usada é recomendável que o processo seja parado quando a densidade de corrente deixa de ser máxima, 781 A/m2. Assim é possível evitar o aumento de impurezas nos produtos, contra difusão, descida instantânea do pH e uma dessalinização pouco eficiente. A nível piloto o principal fornecedor de membranas e unidade de tratamento “stack” é a marca alemã PCA. Sendo assim realizaram-se ensaios de repetibilidade, contra difusão, avaliação económica e upscaling utilizando as membranas bipolares PCA. A nível económico estudou-se o uso de dois tipos de unidades de tratamento; EDQ 380 e EDQ 1600, para diferentes níveis de dessalinização (50, 75 e 80%). Tendo em conta a otimização económica, é recomendável uma dessalinização máxima de 80%, uma vez que a eficiência de processo a este ponto é de 40%. A aplicação do método com a unidade EDQ 1600 para uma dessalinização de 50% é a mais vantajosa economicamente, com custos de 16 €/m3 de efluente tratado ou 0,78 €/kg Cl- removido. O número de unidades necessárias é 4 posicionados em série.