947 resultados para Test method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To compare new bone formation in maxillary sinus augmentation procedures using biomaterial associated with mesenchymal stem cells (MSCs) separated by two different isolation methods. Background: In regenerative medicine open cell concentration systems are only allowed for clinical application under good manufacturing practice conditions. Methods: Mononuclear cells, including MSCs, were concentrated with either the synthetic poylsaccharid (FICOLL) method (classic open system-control group, n = 6 sinus) or the bone marrow aspirate concentrate (BMAC) method (closed system-test group, n = 12 sinus) and transplanted in combination with biomaterial. A sample of the cells was characterized by their ability to differentiate. After 4.1 months (SD +/- 1.0) bone biopsies were obtained and analyzed. Results: The new bone formation in the BMAC group was 19.9% (90% confidence interval [CI], 10.9-29), and in the FICOLL group was 15.5% (90% CI, 8.6-22.4). The 4.4% difference was not significant (90% CI, -4.6-13.5; p = 0.39). MSCs could be differentiated into osteogenic, chondrogenic, and adipogenic lineages. Conclusion: MSCs harvested from bone marrow aspirate in combination with bovine bone matrix particles can form lamellar bone and provide a reliable base for dental implants. The closed BMAC system is suited to substitute the open FICOLL system in bone regeneration procedures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

P>This study aimed to verify the effect of modified section method and laser-welding on the accuracy of fit of ill-fitting commercially pure titanium (cp Ti) and Ni-Cr alloy one-piece cast frameworks. Two sets of similar implant-supported frameworks were constructed. Both groups of six 3-unit implant-supported fixed partial dentures were cast as one-piece [I: Ni-Cr (control) and II: cp Ti] and evaluated for passive fitting in an optical microscope with both screws tightened and with only one screw tightened. All frameworks were then sectioned in the diagonal axis at the pontic region (III: Ni-Cr and IV: cp Ti). Sectioned frameworks were positioned in the matrix (10-Ncm torque) and laser-welded. Passive fitting was evaluated for the second time. Data were submitted to anova and Tukey-Kramer honestly significant difference tests (P < 0 center dot 05). With both screws tightened, one-piece cp Ti group II showed significantly higher misfit values (27 center dot 57 +/- 5 center dot 06 mu m) than other groups (I: 11 center dot 19 +/- 2 center dot 54 mu m, III: 12 center dot 88 +/- 2 center dot 93 mu m, IV: 13 center dot 77 +/- 1 center dot 51 mu m) (P < 0 center dot 05). In the single-screw-tightened test, with readings on the opposite side to the tightened side, Ni-Cr cast as one-piece (I: 58 center dot 66 +/- 14 center dot 30 mu m) was significantly different from cp Ti group after diagonal section (IV: 27 center dot 51 +/- 8 center dot 28 mu m) (P < 0 center dot 05). On the tightened side, no significant differences were found between groups (P > 0 center dot 05). Results showed that diagonally sectioning ill-fitting cp Ti frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves passivity levels of the same frameworks when compared to one-piece cast structures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to test a device developed to improve the functionality, accuracy and precision of the original technique for sweating rate measurements proposed by Schleger and Turner [Schleger AV, Turner HG (1965) Aust J Agric Res 16:92-106]. A device was built for this purpose and tested against the original Schleger and Turner technique. Testing was performed by measuring sweating rates in an experiment involving six Mertolenga heifers subjected to four different thermal levels in a climatic chamber. The device exhibited no functional problems and the results obtained with its use were more consistent than with the Schleger and Turner technique. There was no difference in the reproducibility of the two techniques (same accuracy), but measurements performed with the new device had lower repeatability, corresponding to lower variability and, consequently, to higher precision. When utilizing this device, there is no need for physical contact between the operator and the animal to maintain the filter paper discs in position. This has important advantages: the animals stay quieter, and several animals can be evaluated simultaneously. This is a major advantage because it allows more measurements to be taken in a given period of time, increasing the precision of the observations and diminishing the error associated with temporal hiatus (e.g., the solar angle during field studies). The new device has higher functional versatility when taking measurements in large-scale studies (many animals) under field conditions. The results obtained in this study suggest that the technique using the device presented here could represent an advantageous alternative to the original technique described by Schleger and Turner.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present study, the validation of an enzyme-linked immunosorbent assay (ELISA) for serodiagnosis of canine brucellosis is described. Two different antigenic extracts, obtained by heat or ultrasonic homogenization of microbial antigens from a wild isolate of Brucella canis bacteria, were compared by ELISA and Western blot (WB). A total of 145 canine sera were used to define sensitivity, specificity and accuracy of the ELISA as follows: (1) sera from 34 animals with natural B. canis infection, confirmed by blood culture and PCR, as well as 51 sera samples from healthy dogs with negative results by the agar-gel immunodiffusion (ACID) test for canine brucellosis, were used as the control panel for B. cants infection; and (2) to scrutinize the possibility of cross reactions with other common dog infections in the same geographical area in Brazil, 60 sera samples from dogs harboring known infections by Leptospira sp., Ehrlichia canis, canine distemper virus (CDV), Neospora caninum, Babesia canis and Leishmania chagasi (10 in each group) were included in the study. The ELISA using heat soluble bacterial extract (HE-antigen) as antigen showed the best values of sensitivity (91.18%), specificity (100%) and accuracy (96.47%). In the WB analyses, the HE-antigen showed no cross-reactivity with sera from dogs with different infections, while the B. canis sonicate had various protein bands identified by those sera. The performance of the ELISA standardized with the heat soluble B. canis antigen indicates that this assay can be used as a reliable and practical method to confirm infection by this microorganism, as well as a tool for seroepidemiological studies. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Boyadjian et al dental wash technique provides, in certain contexts, the only chance to analyze and quantify the use of plants by past populations and is therefore an important milestone for the reconstruction of paleodiet. With this paper we present recent investigations and results upon the influence of this method on teeth. A series of six teeth from a three thousand years old Brazilian shellmound (Jabuticabeira II) was examined before and after dental wash. The main focus was documenting the alteration of the surfaces and microstructures. The status of all teeth were documented using macrophotography, optical light microscopy, and atmospheric Secondary Electron Microscopy (aSEM) prior and after applying the dental wash technique. The comparison of pictures taken before and after dental wash showed the different degrees of variation and damage done to the teeth but, also, provided additional information about microstructures, which have not been visible before. Consequently we suggest that dental wash should only be carried out, if absolutely necessary, after dental pathology, dental morphology and microwear studies have been accomplished. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new approach for solving the optimal power flow (OPF) problem is established by combining the reduced gradient method and the augmented Lagrangian method with barriers and exploring specific characteristics of the relations between the variables of the OPF problem. Computer simulations on IEEE 14-bus and IEEE 30-bus test systems illustrate the method. (c) 2007 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Global optimization seeks a minimum or maximum of a multimodal function over a discrete or continuous domain. In this paper, we propose a hybrid heuristic-based on the CGRASP and GENCAN methods-for finding approximate solutions for continuous global optimization problems subject to box constraints. Experimental results illustrate the relative effectiveness of CGRASP-GENCAN on a set of benchmark multimodal test functions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The immersed boundary method is a versatile tool for the investigation of flow-structure interaction. In a large number of applications, the immersed boundaries or structures are very stiff and strong tangential forces on these interfaces induce a well-known, severe time-step restriction for explicit discretizations. This excessive stability constraint can be removed with fully implicit or suitable semi-implicit schemes but at a seemingly prohibitive computational cost. While economical alternatives have been proposed recently for some special cases, there is a practical need for a computationally efficient approach that can be applied more broadly. In this context, we revisit a robust semi-implicit discretization introduced by Peskin in the late 1970s which has received renewed attention recently. This discretization, in which the spreading and interpolation operators are lagged. leads to a linear system of equations for the inter-face configuration at the future time, when the interfacial force is linear. However, this linear system is large and dense and thus it is challenging to streamline its solution. Moreover, while the same linear system or one of similar structure could potentially be used in Newton-type iterations, nonlinear and highly stiff immersed structures pose additional challenges to iterative methods. In this work, we address these problems and propose cost-effective computational strategies for solving Peskin`s lagged-operators type of discretization. We do this by first constructing a sufficiently accurate approximation to the system`s matrix and we obtain a rigorous estimate for this approximation. This matrix is expeditiously computed by using a combination of pre-calculated values and interpolation. The availability of a matrix allows for more efficient matrix-vector products and facilitates the design of effective iterative schemes. We propose efficient iterative approaches to deal with both linear and nonlinear interfacial forces and simple or complex immersed structures with tethered or untethered points. One of these iterative approaches employs a splitting in which we first solve a linear problem for the interfacial force and then we use a nonlinear iteration to find the interface configuration corresponding to this force. We demonstrate that the proposed approach is several orders of magnitude more efficient than the standard explicit method. In addition to considering the standard elliptical drop test case, we show both the robustness and efficacy of the proposed methodology with a 2D model of a heart valve. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a variable time step, fully adaptive in space, hybrid method for the accurate simulation of incompressible two-phase flows in the presence of surface tension in two dimensions. The method is based on the hybrid level set/front-tracking approach proposed in [H. D. Ceniceros and A. M. Roma, J. Comput. Phys., 205, 391400, 2005]. Geometric, interfacial quantities are computed from front-tracking via the immersed-boundary setting while the signed distance (level set) function, which is evaluated fast and to machine precision, is used as a fluid indicator. The surface tension force is obtained by employing the mixed Eulerian/Lagrangian representation introduced in [S. Shin, S. I. Abdel-Khalik, V. Daru and D. Juric, J. Comput. Phys., 203, 493-516, 2005] whose success for greatly reducing parasitic currents has been demonstrated. The use of our accurate fluid indicator together with effective Lagrangian marker control enhance this parasitic current reduction by several orders of magnitude. To resolve accurately and efficiently sharp gradients and salient flow features we employ dynamic, adaptive mesh refinements. This spatial adaption is used in concert with a dynamic control of the distribution of the Lagrangian nodes along the fluid interface and a variable time step, linearly implicit time integration scheme. We present numerical examples designed to test the capabilities and performance of the proposed approach as well as three applications: the long-time evolution of a fluid interface undergoing Rayleigh-Taylor instability, an example of bubble ascending dynamics, and a drop impacting on a free interface whose dynamics we compare with both existing numerical and experimental data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nursing school graduates are under pressure to pass the RN-NCLEX Exam on the first attempt since New York State monitors the results and uses them to evaluate the school’s nursing programs. Since the RN-NCLEX Exam is a standardized test, we sought a method to make our students better test takers. The use of on-line computer adaptive testing has raised our student’s standardized test scores at the end of the nursing course.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

If a plastic material is used as a print bearer there are a need of a special surface treatment to get agod and durable printing. The most used surface treatment technique for the moment is coronatreatment. This kind of treatment has unfortunately showed not to be so durable in the long term.Plasma treatment which in this case uses different kind of gases in the treatment of polypropyleneis shown as a more effective treatment in this project. When the plasma treated surface has beenprinted is the good quality last much longer and the adhesion between the ink and the surface isremained. To test this adhesion is for the moment a standard used (ASTM D3359). This standardhas appeared unstable and dependent at many different factors, which gives a big variation in thetest results. Because of this has new test methods been carried out to give a more even and morereliable result in the test of the adhesion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The main purpose of this thesis project is to prediction of symptom severity and cause in data from test battery of the Parkinson’s disease patient, which is based on data mining. The collection of the data is from test battery on a hand in computer. We use the Chi-Square method and check which variables are important and which are not important. Then we apply different data mining techniques on our normalize data and check which technique or method gives good results.The implementation of this thesis is in WEKA. We normalize our data and then apply different methods on this data. The methods which we used are Naïve Bayes, CART and KNN. We draw the Bland Altman and Spearman’s Correlation for checking the final results and prediction of data. The Bland Altman tells how the percentage of our confident level in this data is correct and Spearman’s Correlation tells us our relationship is strong. On the basis of results and analysis we see all three methods give nearly same results. But if we see our CART (J48 Decision Tree) it gives good result of under predicted and over predicted values that’s lies between -2 to +2. The correlation between the Actual and Predicted values is 0,794in CART. Cause gives the better percentage classification result then disability because it can use two classes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Modular product architectures have generated numerous benefits for companies in terms of cost, lead-time and quality. The defined interfaces and the module’s properties decrease the effort to develop new product variants, and provide an opportunity to perform parallel tasks in design, manufacturing and assembly. The background of this thesis is that companies perform verifications (tests, inspections and controls) of products late, when most of the parts have been assembled. This extends the lead-time to delivery and ruins benefits from a modular product architecture; specifically when the verifications are extensive and the frequency of detected defects is high. Due to the number of product variants obtained from the modular product architecture, verifications must handle a wide range of equipment, instructions and goal values to ensure that high quality products can be delivered. As a result, the total benefits from a modular product architecture are difficult to achieve. This thesis describes a method for planning and performing verifications within a modular product architecture. The method supports companies by utilizing the defined modules for verifications already at module level, so called MPV (Module Property Verification). With MPV, defects are detected at an earlier point, compared to verification of a complete product, and the number of verifications is decreased. The MPV method is built up of three phases. In Phase A, candidate modules are evaluated on the basis of costs and lead-time of the verifications and the repair of defects. An MPV-index is obtained which quantifies the module and indicates if the module should be verified at product level or by MPV. In Phase B, the interface interaction between the modules is evaluated, as well as the distribution of properties among the modules. The purpose is to evaluate the extent to which supplementary verifications at product level is needed. Phase C supports a selection of the final verification strategy. The cost and lead-time for the supplementary verifications are considered together with the results from Phase A and B. The MPV method is based on a set of qualitative and quantitative measures and tools which provide an overview and support the achievement of cost and time efficient company specific verifications. A practical application in industry shows how the MPV method can be used, and the subsequent benefits

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Syfte: Att testa den patientenkät som används i utvärdering av en leversjuksköterskemottagning på patienter med dekompenserad levercirros för att undersöka upplevelsen av att besvara frågorna samt frågornas relevans till patientens situation. Metod: Pilotstudiens metod var mixad. Resultat: Spridningen av deltagarnas upplevelse av oro/obehag av enkäten var stor (VAS 6-100 millimeter). Vid få sjukdomssymtom väcktes oro om framtida sjukdomsutveckling men vid längre tids sjukdom kändes samtliga symtom igen, tankar om tidigare beteende uppstod vid alkoholsorsakad sjukdom. En mindre spridning (VAS 66-92 millimeter) sågs gällande hur viktiga/väsentliga frågorna upplevdes. Frågor om bemötande ansågs viktiga och påverkade upplevelsen av rätten till vård. Kompletterande frågor om individuellt anpassad information samt upplevelsen av delaktighet vid information efterfrågades. Deltagarna visade hög uppskattning (VAS 73-95 millimeter) till att sjukdomen/situation uppmärksammades genom enkäten. Besöken till sjuksköterskan skiljde sig från läkarbesök. Sjuksköterskan fokuserade på egenvård och mer tid fanns för information. För en informant innebar försöksverksamheten ökade antal sjukhusbesök, samordning innebar för- och nackdelar. Vid symtom på fatigue och nedsatt koncentrationsförmåga upplevdes enkäten lång, tvådelad enkät efterfrågades. Vid lindrig sjukdom upplevdes enkäten inte ansträngande. Språket var enkelt att förstå och innehållet upplevdes relevant. De öppna frågeställningarna tillförde inte något för de tre informanterna.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In boreal forest regions, a great portion of forest tree seedlings are stored indoors in late autumn to prevent seedlings from outdoor winter damage. For seedlings to be able to survive in storage it is crucial that they store well and can cope with the dark and cold storage environment. The aim of this study was to search for genes that can determine the vitality status of Norway spruce (Picea abies (L.) Karst.) seedlings during frozen storage. Furthermore, the sensitivity of the ColdNSure (TM) test, a gene activity test that predicts storability was assessed. The storability of seedlings was tested biweekly by evaluating damage with the gene activity test and the electrolyte leakage test after freezing seedlings to -25 A degrees C (the SELdiff-25 method). In parallel, seedlings were frozen stored at -3 A degrees C. According to both methods, seedlings were considered storable from week 41. This also corresponded to the post storage results determined at the end of the storage period. In order to identify vitality indicators, Next Generation Sequencing (NGS) was performed on bud samples collected during storage. Comparing physiological post storage data to gene analysis data revealed numerous vitality related genes. To validate the results, a second trial was performed. In this trial, gene activity was better in predicting seedling storability than the conventional freezing test; this indicates a high sensitivity level of this molecular assay. For multiple indicators a clear switch between damaged and vital seedlings was observed. A collection of indicators will be used in the future development of a commercial vitality test.