831 resultados para Screening leerlingkenmerken
Resumo:
BACKGROUND: Newborn screening (NBS) for Cystic Fibrosis (CF) has been introduced in many countries, but there is no ideal protocol suitable for all countries. This retrospective study was conducted to evaluate whether the planned two step CF NBS with immunoreactive trypsinogen (IRT) and 7 CFTR mutations would have detected all clinically diagnosed children with CF in Switzerland. METHODS: IRT was measured using AutoDELFIA Neonatal IRT-Kit in stored NBS cards. RESULTS: Between 2006 and 2009, 66 children with CF were reported, 4 of which were excluded for various reasons (born in another country, NBS at 6 months, no informed consent). 98% (61/62) had significantly higher IRT compared to matched control group. There was one false negative IRT result in an asymptomatic child with atypical CF (normal pancreatic function and sweat test). CONCLUSIONS: All children but one with atypical CF would have been detected with the planned two step protocol.
Resumo:
Shared decision-making approach to uncertain clinical situations such as cancer screening seems more appropriate than ever. Shared decision making can be defined as an interactive process where physician and patient share all the stages of the decision making process. For patients who wish to be implicated in the management of their health conditions, physicians might express difficulty to do so. Use of patient decision aids appears to improve such process of shared decision making. L'incertitude quant à l'efficacité de certains dépistages de cancers et du traitement en cas de test positif rend l'application du partage de la décision particulièrement appropriée. Le concept du partage de la décision peut être défini comme un processus interactif où le médecin et le patient partagent les étapes du processus de décision. Face aux patients qui désirent être impliqués dans les décisions concernant leur santé, les médecins peinent parfois à le faire. Or, l'utilisation d'outils d'aide à la décision est un moyen efficace de favoriser ce partage de l'information et, si souhaité par le patient, de la décision.
Resumo:
Suite à des essais cliniques randomisés démontrant l'efficacité du dépistage de l'anévrisme de l'aorte abdominale (AAA) par échographie, plusieurs recommandations ont été publiées dans de nombreux pays en faveur du dépistage dans une partie de la population générale. De plus, au-delà de la rupture aortique, le dépistage d'un petit AAA semble être une bonne occasion d'appliquer les stratégies de prévention secondaire, permettant une amélioration globale du pronostic cardiovasculaire du patient. Ces recommandations sont cependant peu suivies; les campagnes de dépistage systématique sont rares, laissant la responsabilité du dépistage au médecin généraliste. Cet article se propose de discuter les raisons de la non-implantation du dépistage de l'AAA. [Abstract] Following the evidence of benefits of ultrasound screening for abdominal aorta aneurysms (AAA), several guidelines support this screening in population. Beyond the prompt diagnosis of AAA prior to its rupture of grim vital prognosis, small AAA can beconsidered as a prognostic marker for cardiovascular diseases (CVD). Yet, its detection is an opportunity for secondary prevention to reduce CVD mortality. Despite, these guidelines are poorly applied: systematic screening campaigns are infrequent, making the screening of family physicians responsibility. While the major benefit from this screening strategy is to reduce AAA-related death (but only trivial effect on long-term total mortality), this explains only partially the lack of guidelines implementation. The reasons of the poor implementation of these guidelines are discussed herein.
Resumo:
Au vu de l'augmentation de la prévalence de l'insuffisance rénale chronique (IRC), une détection précoce a été proposée. Certaines organisations de santé proposent des mesures de détection précoce (par exemple : taux de filtration glomérulaire). L'efficacité du dépistage de l'IRC n'est cependant pas connue puisqu'aucune étude randomisée contrôlée n'a été conduite. Si le test de dépistage de l'IRC est simple et peu onéreux, un dépistage n'est justifié que s'il améliore le pronostic par rapport à l'absence de dépistage avec un rapport risques-bénéfices favorable et un rapport coût-efficacité acceptable. Sur la base d'études observationnelles et de modèles de rapport coût-efficacité, le dépistage de l'IRC doit être proposé chez les patients hypertendus et/ou diabétiques mais pas dans la population générale. [Abstract] Given the increasing prevalence of chronic kidney disease (CKD), early detection has been proposed. Some organizations recommend CKD screening. Yet, the efficacy of CKD screening is unknown given the absence of randomized controlled trial conducted so far. While CKD screening tests (e.g., glomerular filtration rate) are simple and inexpensive, CKD screening can only be justified if it reduces CKD-related mortality and/or CKD-related morbidity compared to no screening. In addition, CKD screening must provide more benefits than risks to the participants and must be cost-effective. Based on observational studies and cost-effectiveness models, CKD screening has to be proposed to high risk population (patients with hypertension and/or diabetes) but not to the general population.
Resumo:
BACKGROUND: Detailed comparison of effectiveness between organised and opportunistic mammography screening operating in the same country has seldom been carried out. PATIENTS AND METHODS: Prognostic indicators, as defined in the European Guidelines, were used to evaluate screening effectiveness in Switzerland. Matching of screening programmes' records with population-based cancer registries enabled to compare indicators of effectiveness by screening and detection modality (organised versus opportunistic screening, unscreened, interval cancers). Comparisons of prognostic profile were also drawn with two Swiss regions uncovered by service screening of low and high prevalence of opportunistic screening, respectively. RESULTS: Opportunistic and organised screening yielded overall little difference in prognostic profile. Both screening types led to substantial stage shifting. Breast cancer prognostic indicators were systematically more favourable in Swiss regions covered by a programme. In regions without a screening programme, the higher the prevalence of opportunistic screening, the better was the prognostic profile. CONCLUSIONS: Organised screening appeared as effective as opportunistic screening. Mammography screening has strongly influenced the stage distribution of breast cancer in Switzerland, and a favourable impact on mortality is anticipated. Extension of organised mammography screening to the whole of Switzerland can be expected to further improve breast cancer prognosis in a cost-effective way.
Resumo:
The concept of early detection to then intervene and improve the prognostic seems straightforward. Applied to asymptomatic subjects, this concept--screening--is rather complex. This review presents the rational and fundamental principles of screening. It underscores the fundamental principles related to the disease and to the screening test considered, the importance of considering screening as a program rather than a test only, and the validity of measures used to evaluate the efficacy of screening. Lastly, it reviews the most frequently bias encountered in screening studies and interpretations.
Resumo:
Surfactants are used as additives in topical pharmaceuticals and drug delivery systems. The biocompatibility of amino acid-based surfactants makes them highly suitable for use in these fields, but tests are needed to evaluate their potential toxicity. Here we addressed the sensitivity of tumor (HeLa, MCF-7) and non-tumor (3T3, 3T6, HaCaT, NCTC 2544) cell lines to the toxic effects of lysine-based surfactants by means of two in vitro endpoints (MTT and NRU). This comparative assay may serve as a reliable approach for predictive toxicity screening of chemicals prior to pharmaceutical applications. After 24-h of cell exposure to surfactants, differing toxic responses were observed. NCTC 2544 and 3T6 cell lines were the most sensitive, while both tumor cells and 3T3 fibroblasts were more resistant to the cytotoxic effects of surfactants. IC50-values revealed that cytotoxicity was detected earlier by MTT assay than by NRU assay, regardless of the compound or cell line. The overall results showed that surfactants with organic counterions were less cytotoxic than those with inorganic counterions. Our findings highlight the relevance of the correct choice and combination of cell lines and bioassays in toxicity studies for a safe and reliable screen of chemicals with potential interest in pharmaceutical industry.
Resumo:
PURPOSE: To evaluate the diagnostic performance of abdominal radiography in the detection of illegal intracorporeal containers (hereafter, packets), with low-dose computed tomography (CT) as the reference standard. MATERIALS AND METHODS: This study was approved by the institutional ethical review board, with written informed consent. From July 2007 to July 2010, 330 people (296 men, 34 women; mean age, 32 years [range, 18-55 years]) suspected of having ingested drug packets underwent supine abdominal radiography and low-dose CT. The presence or absence of packets at abdominal radiography was reported, with low-dose CT as the reference standard. The density and number of packets (≤ 12 or >12) at low-dose CT were recorded and analyzed to determine whether those variables influence interpretation of results at abdominal radiography. RESULTS: Packets were detected at low-dose CT in 53 (16%) suspects. Sensitivity of abdominal radiography for depiction of packets was 0.77 (41 of 53), and specificity was 0.96 (267 of 277). The packets appeared isoattenuated to the bowel contents at low-dose CT in 16 (30%) of the 53 suspects with positive results. Nineteen (36%) of the 53 suspects with positive low-dose CT results had fewer than 12 packets. Packets that were isoattenuated at low-dose CT and a low number of packets (≤12) were both significantly associated with false-negative results at abdominal radiography (P = .004 and P = .016, respectively). CONCLUSION: Abdominal radiography is mainly limited by low sensitivity when compared with low-dose CT in the screening of people suspected of carrying drug packets. Low-dose CT is an effective imaging alternative to abdominal radiography.
Resumo:
BACKGROUND: Direct-infusion ESI-MS/MS is a powerful approach for the identification of substances in complex mixtures. The aim of this work was to investigate its applicability to the toxicological screening of blood samples. A simple protein precipitation was used, followed by a 15 min infusion of the extract in the mass spectrometer. RESULTS: The application of the procedure to commercial quality controls and authentic post-mortem blood samples demonstrated that the direct-infusion ESI-MS/MS approach enables the simultaneous identification of substances that require different chromatographic conditions. However, poor sensitivity was observed for benzodiazepine, amphetamines and opiate compounds. CONCLUSION: Considering the facile implementation and positive performance of direct-infusion ESI-MS/MS, this approach may to be a valuable complementary technique for systematic toxicological analysis procedures.
Resumo:
BACKGROUND: The objective is to develop a cost-effective, reliable and non invasive screening test able to detect early CRCs and adenomas. This is done on a nucleic acids multigene assay performed on peripheral blood mononuclear cells (PBMCs). METHODS: A colonoscopy-controlled study was conducted on 179 subjects. 92 subjects (21 CRC, 30 adenoma >1 cm and 41 controls) were used as training set to generate a signature. Other 48 subjects kept blinded (controls, CRC and polyps) were used as a test set. To determine organ and disease specificity 38 subjects were used: 24 with inflammatory bowel disease (IBD),14 with other cancers (OC). Blood samples were taken and PBMCs were purified. After the RNA extraction, multiplex RT-qPCR was applied on 92 different candidate biomarkers. After different univariate and multivariate analysis 60 biomarkers with significant p-values (<0.01) were selected. 2 distinct biomarker signatures are used to separate patients without lesion from those with CRC or with adenoma, named COLOX CRC and COLOX POL. COLOX performances were validated using random resampling method, bootstrap. RESULTS: COLOX CRC and POL tests successfully separate patients without lesions from those with CRC (Se 67%, Sp 93%, AUC 0.87), and from those with adenoma > 1cm (Se 63%, Sp 83%, AUC 0.77). 6/24 patients in the IBD group and 1/14 patients in the OC group have a positive COLOX CRC. CONCLUSION: The two COLOX tests demonstrated a high Se and Sp to detect the presence of CRCs and adenomas > 1 cm. A prospective, multicenter, pivotal study is underway in order to confirm these promising results in a larger cohort.