611 resultados para Rotary Sorter


Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the efficacy of ProTaper Universal rotary retreatment system and the influence of sealer type on the presence of filling debris in the reinstrumented canals viewed in an operative clinical microscope. Forty-five palatal root canals of first molars were filled with gutta-percha and one of the following sealers: G1, EndoFill; G2, AH Plus; G3, Sealapex. The canals were then reinstrumented with ProTaper Universal rotary system. Roots were longitudinally sectioned and examined under an operative clinical microscope (10x), and the amount of filling debris on canal walls was analyzed using the AutoCAD 2004 software. A single operator used a specific software tool to outline the canal area and the filling debris area in each third (cervical, middle, and apical), as well as the total canal area. Data were analyzed by Kruskal-Wallis test and Tukey test at P < 0.05. Sealapex demonstrated significant differences in the average of filling debris area/canal among the 3 thirds. This group revealed that apical third showed more debris than the both cervical and middle third (P < 0.0001). Endofill presented significantly more filling debris than Sealapex in the cervical third (P < 0.05). In the middle (P = 0.12) and apical third (P = 0.10), there were no differences amongst groups. Debris was left in all canal thirds, regardless of the retreatment technique. The greatest differences between techniques and sealers were found in the cervical third. Microsc. Res. Tech. 75:12331236, 2012. (C) 2012 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Smilax L. in Brazil is represented by 32 taxa and it is a taxonomically difficult genus because the plants are dioecious and show wide phenotypic variation. The analysis and use of leaf anatomy characters is recognized as a frequently successful taxonomic method to distinguish between individual taxon, when floral material is absent or minute differences in flowers and foliage exist such as in Smilax. The aim of this study was to characterize the anatomical features of the aerial organs in Smilax syphilitica collected from the Atlantic Rainforest, in Santa Teresa-ES and the Smilax aff syphilitica from the Amazon Rainforest, in Manaus, Brazil. For this, a total of three samples of Smilax were collected per site. Sample leaves and stems were fixed with FAA 50, embedded in historesin, sectioned on a rotary microtome, stained and mounted in synthetic resin. Additionally, histochemical tests were performed and cuticle ornamentation was analyzed with standard scanning electron microscopy. S. syphilitica and S. aff syphilitica differed in cuticle ornamentation, epidermal cell arrangement and wall thickness, stomata type and orientation, calcium oxalate crystal type, and position of stem thorns. Leaf blades of S. syphilitica from the Amazon Rainforest have a network of rounded ridges on both sides, while in S. aff syphilitica, these ridges are parallel and the spaces between them are filled with numerous membranous platelets. Viewed from the front, the epidermal cells of S. syphilitica have sinuous walls (even more pronounced in samples from the Amazon); while in S. aff syphilitica, these cells are also sinuous but elongated in the cross-section of the blade and arranged in parallel. Stomata of S. syphilitica are paracytic, whereas in S. aff syphilitica, are both paracytic and anisocytic, and their polar axes are directed towards the mid-vein. Calcium oxalate crystals in S. syphilitica are prisms, whereas in S. aff syphilitica, crystal sand. Thorns occur in nodes and internodes in S. syphilitica but only in internodes in S. aff syphilitica. These features have proven to be of diagnostic value and may support a separation into two species, but future studies are needed to confirm that S. aff syphilitica is indeed a new taxon. Rev. Biol. Trop. 60(3): 1137-1148. Epub 2012 September 01.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: Aerobic exercise training has been established as an important nonpharmacological treatment for hypertension. We investigated whether the number and function of endothelial progenitor cells (EPCs) are restored after exercise training, potentially contributing to neovascularization in hypertension. Methods: Twelve-week-old male spontaneously hypertensive rats (SHRs, n = 14) and Wistar Kyoto (WKY, n = 14) rats were assigned to four groups: SHR; trained SHR (SHR-T); WKY; and trained WKY. Exercise training consisted of 10 weeks of swimming. EPC number and function, as well as the vascular endothelial growth factor (VEGF), nitrotyrosine and nitrite concentration in peripheral blood were quantified by fluorescence-activated cell sorter analysis (CD34+/Flk1+ cells), colony-forming unit assay, ELISA and nitric oxide (NO) analyzer, respectively. Soleus capillary/fiber ratio and protein expression of VEGF and endothelial NO synthase (eNOS) by western blot were assessed. Results: Exercise training was effective in reducing blood pressure in SHR-T accompanied by resting bradycardia, an increase in exercise tolerance, peak oxygen uptake (VO2) and citrate synthase activity. In response to hypertension, the amount of peripheral blood-EPC and number of colonies were decreased in comparison with control levels. In contrast, exercise training normalized the EPC levels and function in SHR-T accompanied by an increase in VEGF and NO levels. In addition, oxidative stress levels were normalized in SHR-T. Similar results were found in the number and function of bone marrow EPC. Exercise training repaired the peripheral capillary rarefaction in hypertension by a signaling pathway VEGF/eNOS-dependent in SHR-T. Moreover, improvement in EPC was significantly related to angiogenesis. Conclusion: Our data show that exercise training repairs the impairment of EPC in hypertension, which could be associated with peripheral revascularization, suggesting a mechanism for its potential therapeutic: application in vascular diseases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to compare two methods of assessing apical transportation in curved canals after rotary instrumentation, namely, cross-sections and micro-computed tomography (mu CT). Thirty mandibular molars were divided into two groups and prepared according to the requirements of each method. In G1 (cross-sections), teeth were embedded in resin blocks and sectioned at 2.0, 3.5, and 5.0 mm from the anatomic apex. Pre- and postoperative sections were photographed and analyzed. In G2 (mu CT), teeth were embedded in a rubber-base impression material and scanned before and after instrumentation. Mesiobuccal canals were instrumented with the Twisted File (TF) system (SybronEndo, Orange, USA), and mesiolingual canals, with the Endo Sequence (ES) system (Brasseler, Savannah, USA). Images were reconstructed, and sections corresponding to distances 2.0, 3.5, and 5.0 mm from the anatomic apex were selected for comparison. Data were analyzed using Mann-Whitney's test at a 5% significance level. The TF and ES instruments produced little deviation from the root canal center, with no statistical difference between them (P > 0.05). The canal transportation results were significantly lower (0.056 mm) in G2 than in G1 (0.089 mm) (p = 0.0012). The mu CT method was superior to the cross-section method, especially in view of its ability to preserve specimens and provide results that are more closely related to clinical situations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The aim of the present work was to evaluate the resistance to flexural fatigue of Reciproc R25 nickel-titanium files, 25 mm, used in continuous rotation motion or reciprocation motion, in dynamic assays device. Methods: Thirty-six Reciproc R25 files were divided into 2 groups (n = 18) according to kinematics applied, continuous rotary (group CR) and reciprocation motion (group RM). The files were submitted to dynamic assays device moved by an electric engine with 300 rpm of speed that permitted the reproduction of pecking motion. The files run on a ring's groove of temperate steel, simulating instrumentation of a curved root canal with 400 and 5 mm of curvature radius. The fracture of file was detected by sensor of device, and the time was marked. The data were analyzed statistically by Student's t test, with level of significance of 95%. Results: The instruments moved by reciprocating movement reached significantly higher numbers of cycles before fracture (mean, 1787.78 cycles) when compared with instruments moved by continuous rotary (mean, 816.39 cycles). Conclusions: The results showed that the reciprocation motion improves flexural fatigue resistance in nickel-titanium instrument Reciproc R25 when compared with continuous rotation movement. (J Endod 2012;38:684-687)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sensor and actuator based on laminated piezocomposite shells have shown increasing demand in the field of smart structures. The distribution of piezoelectric material within material layers affects the performance of these structures; therefore, its amount, shape, size, placement, and polarization should be simultaneously considered in an optimization problem. In addition, previous works suggest the concept of laminated piezocomposite structure that includes fiber-reinforced composite layer can increase the performance of these piezoelectric transducers; however, the design optimization of these devices has not been fully explored yet. Thus, this work aims the development of a methodology using topology optimization techniques for static design of laminated piezocomposite shell structures by considering the optimization of piezoelectric material and polarization distributions together with the optimization of the fiber angle of the composite orthotropic layers, which is free to assume different values along the same composite layer. The finite element model is based on the laminated piezoelectric shell theory, using the degenerate three-dimensional solid approach and first-order shell theory kinematics that accounts for the transverse shear deformation and rotary inertia effects. The topology optimization formulation is implemented by combining the piezoelectric material with penalization and polarization model and the discrete material optimization, where the design variables describe the amount of piezoelectric material and polarization sign at each finite element, with the fiber angles, respectively. Three different objective functions are formulated for the design of actuators, sensors, and energy harvesters. Results of laminated piezocomposite shell transducers are presented to illustrate the method. Copyright (C) 2012 John Wiley & Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo do presente trabalho foi comparar duas sequências diferentes na rapidez e segurança no preparo de canais curvos simulados. Foram empregados 30 blocos de acrílico com canais simulados que foram divididos em Grupo 1 – La Axxess 20 e 35/.06 25/.06, 20/.06, 25/.04 e 20/.04 e Grupo 2 – K3 Universal (VTVT) – 25/.10, 25/.08, 35/.06, 30/.04, 25/.06 e 20/.04. No preparo de todos os blocos empregou-se a velocidade de 250 rpm e torque de 1.4N/cm. Foram confeccionados dois pontos externos de amálgama para mensuração do desvio e adotou-se 17 mm como comprimento de trabalho. No Grupo 1, dilatou-se até o instrumento 25/.04, enquanto que no Grupo 2 até o 25/.06, e cronometrou-se o tempo de preparo de cada bloco. Na análise do desvio, radiografias com lima k 15 (antes) e K 25 (depois) foram realizadas e digitalizadas, medindo-se o ângulo antes e depois no programa Digora for Windows 1.51. Os dados foram comparados pelo teste T-Student e Mann-Whitney. Os resultados mostraram que em ambas as técnicas não ocorreram diferenças significantes entre o ângulo antes e depois e que não ocorreu diferença significante entre os desvios médios do Grupo 1 (0,130) e do Grupo 2 (1,330). No tempo de preparo, o Grupo 1 foi significantemente mais rápido que o Grupo 2. No Grupo 1, ocorreu a fratura de 1 instrumento, enquanto que no Grupo 2 ocorrerem duas fraturas. Concluiu-se que ambas as técnicas são seguras para o preparo de canais simulados curvos, sendo que no Grupo 1 o tempo de preparo é menor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recently, a new ternary phase was discovered in the Ti-Si-B system, located near the Ti6Si2B composition. The present study concerns the preparation of titanium alloys that contain such phase mixed with α-titanium and other intermetallic phases. High-purity powders were initially processed in a planetary ball-mill under argon atmosphere with Ti-18Si-6B and Ti-7.5Si-22.5B at. (%) initial compositions. Variation of parameters such as rotary speed, time, and ball diameters were adopted. The as-milled powders were pressureless sintered and hot pressed. Both the as-milled and sintered materials were characterized by X-ray diffraction, scanning electron microscopy and energy-dispersive spectrometry. Sintered samples have presented equilibrium structures formed mainly by the α-Ti+Ti6Si2B+Ti5Si3+TiB phases. Silicon and boron peaks disappear throughout the milling processes, as observed in the powder diffraction data. Furthermore, an iron contamination of up to 10 at. (%) is measured by X-ray spectroscopy analysis on some regions of the sintered samples. Density, hardness and tribological results for these two compositions are also presented here.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The aim of this study was to investigate the influence of cervical preflaring in determining the initial apical file (IAF) in the palatal roots of maxillary molars, and to determine the morphologic shape of the canal 1 mm short of the apex. METHODS: After preparing standard access cavities the group 1 received the IAF without cervical preflaring (WCP). In groups 2 to 5, preflaring was performed with Gates-Glidden (GG), Anatomic Endodontics Technology (AET), GT Rotary Files (GT) and LA Axxes (LA), respectively. Each canal was sized using manual K-files, starting with size 08 files, and making passive movements until the WL was reached. File sizes were increased until a binding sensation was felt at the WL. The IAF area and the area of the root canal were measured to verify the percentage occupied by the IAF inside the canal in each sample by SEM. The morphologic shape of the root canal was classified as circular, oval or flattened. Statistical analysis was performed by ANOVA/Tukey test (P < 0.05). RESULTS: The decreasing percentages occupied by the IAF inside the canal were: LA>GT=AET>GG>WCP. The morphologic shape was predominantly oval. CONCLUSION: The type of cervical preflaring used interferes in the determination of IAF.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Banco Español de Algas, Las Palmas de Gran Canaria, España. Universidad de Colonia (Alemania)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This PhD thesis presents the results, achieved at the Aerospace Engineering Department Laboratories of the University of Bologna, concerning the development of a small scale Rotary wing UAVs (RUAVs). In the first part of the work, a mission simulation environment for rotary wing UAVs was developed, as main outcome of the University of Bologna partnership in the CAPECON program (an EU funded research program aimed at studying the UAVs civil applications and economic effectiveness of the potential configuration solutions). The results achieved in cooperation with DLR (German Aerospace Centre) and with an helicopter industrial partners will be described. In the second part of the work, the set-up of a real small scale rotary wing platform was performed. The work was carried out following a series of subsequent logical steps from hardware selection and set-up to final autonomous flight tests. This thesis will focus mainly on the RUAV avionics package set-up, on the onboard software development and final experimental tests. The setup of the electronic package allowed recording of helicopter responses to pilot commands and provided deep insight into the small scale rotorcraft dynamics, facilitating the development of helicopter models and control systems in a Hardware In the Loop (HIL) simulator. A neested PI velocity controller1 was implemented on the onboard computer and autonomous flight tests were performed. Comparison between HIL simulation and experimental results showed good agreement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sperm cells need hexoses as a substrate for their function, for both the maintenance of membrane homeostasis and the movement of the tail. These cells have a peculiar metabolism that has not yet been fully understood, but it is clear that they obtain energy from hexoses through glycolisis and/or oxidative phosphorylation. Spermatozoa are in contact with different external environments, beginning from the testicular and epididymal fluid, passing to the seminal plasma and finally to the female genital tract fluids; in addition, with the spread of reproductive biotechnologies, sperm cells are diluted and stored in various media, containing different energetic substrates. To utilize these energetic sources, sperm cells, as other eukaryotic cells, have a well-constructed protein system, that is mainly represented by the GLUT family proteins. These transporters have a membrane-spanning α-helix structure and work as an enzymatic pump that permit a fast gradient dependent passage of sugar molecules through the lipidic bilayer of sperm membrane. Many GLUTs have been studied in man, bull and rat spermatozoa; the presence of some GLUTs has been also demonstrated in boar and dog spermatozoa. The aims of the present study were - to determine the presence of GLUTs 1, 2, 3, 4 and 5 in boar, horse, dog and donkey spermatozoa and to describe their localization; - to study eventual changes in GLUTs location after capacitation and acrosome reaction in boar, stallion and dog spermatozoa; - to determine possible changes in GLUTs localization after capacitation induced by insulin and IGF stimulation in boar spermatozoa; - to evaluate changes in GLUTs localization after flow-cytometric sex sorting in boar sperm cells. GLUTs 1, 2, 3 and 5 presence and localization have been demonstrated in boar, stallion, dog and donkey spermatozoa by western blotting and immunofluorescence analysis; a relocation in GLUTs after capacitation has been observed only in dog sperm cells, while no changes have been observed in the other species examined. As for boar, the stimulation of the capacitation with insulin and IGF didn’t cause any change in GLUTs localization, as well as for the flow cytometric sorting procedure. In conclusion, this study confirms the presence of GLUTs 1, 2 ,3 and 5 in boar, dog, stallion and donkey spermatozoa, while GLUT 4 seems to be absent, as a confirmation of other studies. Only in dog sperm cells capacitating conditions induce a change in GLUTs distribution, even if the physiological role of these changes should be deepened.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Studio della caratterizzazione micromeccanica di provini in alluminio 6082 T6 saldati con la tecnica della rotary friction welding, tecnica innovativa nell’ambito delle tecnologie di giunzione solida, che sfrutta il principio della saldatura per attrito. Dopo un'introduzione teorica sulle principali tematiche affrontate e sui principali sistemi di misura usati, verranno effettuate micrografie dei giunti e prove di microdurezza sugli stessi. Si termina riportando i grafici delle microdurezze trovate, in modo da poter confrontare i risultati ottenuti con le caratteristiche del materiale base. Da questi si osserva che: nonostante la qualità accettabile dei giunti, le elevate temperature raggiunte durante la saldatura hanno alterato il trattamento termico del materiale base, che da T6 assume caratteristiche più simili a un T4. In altre parole il materiale saldato presenta caratteristiche micromeccaniche inferiori a quelle nominalmente assegnabili al materiale base.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Il presente lavoro di tesi si pone come obiettivo la caratterizzazione microstrutturale di una serie di giunti realizzati tramite un innovativo processo di saldatura allo stato solido denominato Rotary Friction Welding. In tale ricerca si descrive il percorso seguito per arrivare a tale caratterizzazione partendo da una discussione delle principali tecniche di saldatura, in particolare quelle per attrito, per passare poi ad un’analisi dettagliata della fase di creazione dei giunti saldati e della successiva fase dedicata alla verifica microstrutturale. I risultati ottenuti, ci forniranno indici di confronto sulla qualità del materiale, sui processi tecnologici, sui trattamenti e su alcune fondamentali proprietà meccaniche

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Root canal treatment is a frequently performed dental procedure and is carried out on teeth in which irreversible pulpitis has led to necrosis of the dental pulp. Removal of the necrotic tissue remnants and cleaning and shaping of the root canal are important phases of root canal treatment. Treatment options include the use of hand and rotary instruments and methods using ultrasonic or sonic equipment. OBJECTIVES: The objectives of this systematic review of randomized controlled trials were to determine the relative clinical effectiveness of hand instrumentation versus ultrasonic instrumentation alone or in conjunction with hand instrumentation for orthograde root canal treatment of permanent teeth. MATERIAL AND METHODS: The search strategy retrieved 226 references from the Cochrane Oral Health Group Trials Register (7), the Cochrane Central Register of Controlled Trials (CENTRAL) (12), MEDLINE (192), EMBASE (8) and LILACS (7). No language restriction was applied. The last electronic search was conducted on December 13th, 2007. Screening of eligible studies was conducted in duplicate and independently. RESULTS: Results were to be expressed as fixed-effect or random-effects models using mean differences for continuous outcomes and risk ratios for dichotomous outcomes with 95% confidence intervals. Heterogeneity was to be investigated including both clinical and methodological factors. No eligible randomized controlled trials were identified. CONCLUSIONS: This review illustrates the current lack of published or ongoing randomized controlled trials and the unavailability of high-level evidence based on clinically relevant outcomes referring to the effectiveness of ultrasonic instrumentation used alone or as an adjunct to hand instrumentation for orthograde root canal treatment. In the absence of reliable research-based evidence, clinicians should base their decisions on clinical experience, individual circumstances and in conjunction with patients' preferences where appropriate. Future randomized controlled trials might focus more closely on evaluating the effectiveness of combinations of these interventions with an emphasis on not only clinically relevant, but also patient-centered outcomes.