993 resultados para Regulatory power
Resumo:
12th European Conference on Wireless Sensor Networks (EWSN 2015). 9 to 11, Feb, 2015. Porto, Portugal
Resumo:
First IFAC Workshop on Fractional Differentiation and Its Application - 19-21 July 2004, Enseirb, Bordeaux, France - FDA'04
Resumo:
This paper reports investigation on the estimation of the short circuit impedance of power transformers, using fractional order calculus to analytically study the influence of the diffusion phenomena in the windings. The aim is to better characterize the medium frequency range behavior of leakage inductances of power transformer models, which include terms to represent the magnetic field diffusion process in the windings. Comparisons between calculated and measured values are shown and discussed.
Resumo:
In this paper, we apply the following four power indices to the Portuguese Parliament: Shapley–Shubik index, Banzhaf index, Deegan–Packel index and Public Good Index. We also present the main notions related with simple games and discuss the features of each power index by means of their axiomatic characterizations.
Resumo:
Smart Grids (SGs) have emerged as the new paradigm for power system operation and management, being designed to include large amounts of distributed energy resources. This new paradigm requires new Energy Resource Management (ERM) methodologies considering different operation strategies and the existence of new management players such as several types of aggregators. This paper proposes a methodology to facilitate the coalition between distributed generation units originating Virtual Power Players (VPP) considering a game theory approach. The proposed approach consists in the analysis of the classifications that were attributed by each VPP to the distributed generation units, as well as in the analysis of the previous established contracts by each player. The proposed classification model is based in fourteen parameters including technical, economical and behavioural ones. Depending of the VPP strategies, size and goals, each parameter has different importance. VPP can also manage other type of energy resources, like storage units, electric vehicles, demand response programs or even parts of the MV and LV distribution network. A case study with twelve VPPs with different characteristics and one hundred and fifty real distributed generation units is included in the paper.
Multi-criteria optimisation approach to increase the delivered power in radial distribution networks
Resumo:
This study proposes a new methodology to increase the power delivered to any load point in a radial distribution network, through the identification of new investments in order to improve the repair time. This research work is innovative and consists in proposing a full optimisation model based on mixed-integer non-linear programming considering the Pareto front technique. The goal is to achieve a reduction in repair times of the distribution networks components, while minimising the costs of that reduction as well as non-supplied energy costs. The optimisation model considers the distribution network technical constraints, the substation transformer taps, and it is able to choose the capacitor banks size. A case study based on a 33-bus distribution network is presented in order to illustrate in detail the application of the proposed methodology.
Resumo:
Proceedings of the 13th International UFZ-Deltares Conference on Sustainable Use and Management of Soil, Sediment and Water Resources - 9–12 June 2015 • Copenhagen, Denmark
Resumo:
The Internet of Things (IoT) has emerged as a paradigm over the last few years as a result of the tight integration of the computing and the physical world. The requirement of remote sensing makes low-power wireless sensor networks one of the key enabling technologies of IoT. These networks encompass several challenges, especially in communication and networking, due to their inherent constraints of low-power features, deployment in harsh and lossy environments, and limited computing and storage resources. The IPv6 Routing Protocol for Low Power and Lossy Networks (RPL) [1] was proposed by the IETF ROLL (Routing Over Low-power Lossy links) working group and is currently adopted as an IETF standard in the RFC 6550 since March 2012. Although RPL greatly satisfied the requirements of low-power and lossy sensor networks, several issues remain open for improvement and specification, in particular with respect to Quality of Service (QoS) guarantees and support for mobility. In this paper, we focus mainly on the RPL routing protocol. We propose some enhancements to the standard specification in order to provide QoS guarantees for static as well as mobile LLNs. For this purpose, we propose OF-FL (Objective Function based on Fuzzy Logic), a new objective function that overcomes the limitations of the standardized objective functions that were designed for RPL by considering important link and node metrics, namely end-to-end delay, number of hops, ETX (Expected transmission count) and LQL (Link Quality Level). In addition, we present the design of Co-RPL, an extension to RPL based on the corona mechanism that supports mobility in order to overcome the problem of slow reactivity to frequent topology changes and thus providing a better quality of service mainly in dynamic networks application. Performance evaluation results show that both OF-FL and Co-RPL allow a great improvement when compared to the standard specification, mainly in terms of packet loss ratio and average network latency. 2015 Elsevier B.V. Al
Resumo:
Transformers may be classified according to dielectric insulation material as follows: • Oil-filled transformers • Dry type transformers
Resumo:
Cloud data centers have been progressively adopted in different scenarios, as reflected in the execution of heterogeneous applications with diverse workloads and diverse quality of service (QoS) requirements. Virtual machine (VM) technology eases resource management in physical servers and helps cloud providers achieve goals such as optimization of energy consumption. However, the performance of an application running inside a VM is not guaranteed due to the interference among co-hosted workloads sharing the same physical resources. Moreover, the different types of co-hosted applications with diverse QoS requirements as well as the dynamic behavior of the cloud makes efficient provisioning of resources even more difficult and a challenging problem in cloud data centers. In this paper, we address the problem of resource allocation within a data center that runs different types of application workloads, particularly CPU- and network-intensive applications. To address these challenges, we propose an interference- and power-aware management mechanism that combines a performance deviation estimator and a scheduling algorithm to guide the resource allocation in virtualized environments. We conduct simulations by injecting synthetic workloads whose characteristics follow the last version of the Google Cloud tracelogs. The results indicate that our performance-enforcing strategy is able to fulfill contracted SLAs of real-world environments while reducing energy costs by as much as 21%.
Resumo:
The integration of wind power in eletricity generation brings new challenges to unit commitment due to the random nature of wind speed. For this particular optimisation problem, wind uncertainty has been handled in practice by means of conservative stochastic scenario-based optimisation models, or through additional operating reserve settings. However, generation companies may have different attitudes towards operating costs, load curtailment, or waste of wind energy, when considering the risk caused by wind power variability. Therefore, alternative and possibly more adequate approaches should be explored. This work is divided in two main parts. Firstly we survey the main formulations presented in the literature for the integration of wind power in the unit commitment problem (UCP) and present an alternative model for the wind-thermal unit commitment. We make use of the utility theory concepts to develop a multi-criteria stochastic model. The objectives considered are the minimisation of costs, load curtailment and waste of wind energy. Those are represented by individual utility functions and aggregated in a single additive utility function. This last function is adequately linearised leading to a mixed-integer linear program (MILP) model that can be tackled by general-purpose solvers in order to find the most preferred solution. In the second part we discuss the integration of pumped-storage hydro (PSH) units in the UCP with large wind penetration. Those units can provide extra flexibility by using wind energy to pump and store water in the form of potential energy that can be generated after during peak load periods. PSH units are added to the first model, yielding a MILP model with wind-hydro-thermal coordination. Results showed that the proposed methodology is able to reflect the risk profiles of decision makers for both models. By including PSH units, the results are significantly improved.
Resumo:
A solFORM é uma empresa de Consultoria e Formação Profissional nas áreas da Energia e Eletricidade, Higiene e Segurança no Trabalho e Comportamental. O seu foco de atuação é a oferta de formação profissional especializada a empresas que trabalham na rede de distribuição de energia elétrica. O diagnóstico realizado permitiu identificar como potencialidade de intervenção os serviços de recursos humanos prestados pela empresa, mais especificamente conceber uma metodologia de avaliação de competências e de identificação de necessidades de desenvolvimento para os técnicos do setor elétrico. A aplicação deste projeto permite adequar as competências dos colaboradores dos clientes da solFORM, empresas do setor elétrico, aos perfis profissionais exigidos pela agência reguladora da formação do setor, a AQTSE - Associação para a Qualificação Técnica do Setor Energético. Assim, o objetivo final será que a solFORM possa propor planos de desenvolvimento adequados às necessidades específicas dos colaboradores das suas empresas clientes. Depois de definido o planeamento estratégico e operacional da nova metodologia foi implementada num grupo piloto. Ao longo da implementação e no final foram avaliados os indicadores que demonstram o cumprimento dos objetivos estabelecidos, assim como a finalidade do projeto.
Resumo:
A liberalização dos mercados de energia elétrica e a crescente integração dos recursos energéticos distribuídos nas redes de distribuição, nomeadamente as unidades de produção distribuída, os sistemas de controlo de cargas através dos programas de demand response, os sistemas de armazenamento e os veículos elétricos, representaram uma evolução no paradigma de operação e gestão dos sistemas elétricos. Este novo paradigma de operação impõe o desenvolvimento de novas metodologias de gestão e controlo que permitam a integração de todas as novas tecnologias de forma eficiente e sustentável. O principal contributo deste trabalho reside no desenvolvimento de metodologias para a gestão de recursos energéticos no contexto de redes inteligentes, que contemplam três horizontes temporais distintos (24 horas, 1 hora e 5 minutos). As metodologias consideram os escalonamentos anteriores assim como as previsões atualizadas de forma a melhorar o desempenho total do sistema e consequentemente aumentar a rentabilidade dos agentes agregadores. As metodologias propostas foram integradas numa ferramenta de simulação, que servirá de apoio à decisão de uma entidade agregadora designada por virtual power player. Ao nível das metodologias desenvolvidas são propostos três algoritmos de gestão distintos, nomeadamente para a segunda (1 hora) e terceira fase (5 minutos) da ferramenta de gestão, diferenciados pela influência que os períodos antecedentes e seguintes têm no período em escalonamento. Outro aspeto relevante apresentado neste documento é o teste e a validação dos modelos propostos numa plataforma de simulação comercial. Para além das metodologias propostas, a aplicação permitiu validar os modelos dos equipamentos considerados, nomeadamente, ao nível das redes de distribuição e dos recursos energéticos distribuidos. Nesta dissertação são apresentados três casos de estudos, cada um com diferentes cenários referentes a cenários de operação futuros. Estes casos de estudos são importantes para verificar a viabilidade da implementação das metodologias e algoritmos propostos. Adicionalmente são apresentadas comparações das metodologias propostas relativamente aos resultados obtidos, complexidade de gestão em ambiente de simulação para as diferentes fases da ferramenta proposta e os benefícios e inconvenientes no uso da ferramenta proposta.
Resumo:
Nos últimos anos, tem-se assistido a uma maior preocupação com o meio ambiente, a atual conjuntura mundial está cada vez mais direcionada para a eficiência energética e para a utilização de fontes de energias renováveis. Os principais governos mundiais, incluindo o português, já perceberam a necessidade de enveredar por esse caminho e nesse sentido aplicam medidas que direcionam e consciencializam a população para a eficiência energética e para as energias renováveis. Em Portugal, o setor das energias renováveis assume atualmente uma posição de extrema importância, resultante da expressão que governo português tem vindo a implementar no panorama energético nacional, da qual resulta uma importante contribuição para o desenvolvimento económico, na criação de riqueza e geração de emprego. Neste contexto, e no caso particular da energia fotovoltaica têm sido implementadas medidas que incentivam a aposta nesta tecnologia, prova disso é o Decreto-Lei n.º 153/2014 aprovado em conselho de ministros em Setembro de 2014, que promove essencialmente o autoconsumo. O autoconsumo consiste na utilização de painéis fotovoltaicos para produção de energia elétrica para consumo próprio com ou sem recurso a equipamentos de acumulação. Em termos práticos, este sistema permite que os consumidores produzam a sua própria energia através de uma fonte renovável ao invés de adquirir essa energia na rede elétrica de serviço público. As políticas de incentivo ao autoconsumo proporcionam uma oportunidade para os consumidores interessados em investir na produção da própria energia elétrica, neste sentido e de forma a ajudar no dimensionamento de unidades de produção de autoconsumo foi desenvolvida, no âmbito desta tese, uma ferramenta de apoio ao dimensionamento de sistemas de autoconsumo fotovoltaico sem acumulação em ambiente doméstico, com o objetivo de estimar as necessidades de potência fotovoltaica a instalar em habitações de baixa tensão normal. Na base da construção desta ferramenta estiveram essencialmente os perfis de consumo, aprovados pela Entidade Reguladora dos Serviços Energéticos, de todos os clientes finais que não dispõem de equipamento de medição com registo de consumos e também a estimativa de produção fotovoltaica desenvolvida pelo Centro Comum de Investigação da Comissão Europeia. A aplicação desenvolvida tem como principal funcionalidade proporcionar ao utilizador o dimensionamento de unidades de produção de autoconsumo fotovoltaico, mediante a introdução de alguns dados tais como o distrito, a potência contratada, a tarifa e o consumo energético anual. Esta aplicação apresenta resultados relativos ao dimensionamento do sistema, como é o caso da potência a instalar e da estimativa de produção fotovoltaica anual, e resultados relativos à análise económica do sistema como é o caso do valor atual líquido, da taxa interna de rentabilidade e do payback do investimento.
Resumo:
The objective was to validate Regulatory Sensory Processing Disorders’ criteria (DC:0-3R, 2005) using empirical data on the presence and severity of sensory modulation deficits and specific psychiatric symptoms in clinical samples. Sixty toddlers who attended a child mental health unit were diagnosed by a clinical team. The following two groups were created: toddlers with RSPD(N = 14) and those with ‘‘other diagnoses in Axis I/II of the DC:0-3R00(OD3R) (N = 46). Independently of the clinical process, parents completed the Infant Toddler Sensory Profile (as a checklist for sensory symptoms) and the Achenbach Behavior Checklist for ages 1/2–5 (CBCL 1/2–5). The scores from the two groups were compared. The results showed the following for the RSPD group: a higher number of affected sensory areas and patterns than in the OD3R group; a higher percentage of sensory deficits in specific sensory categories; and a higher severity of behavioral symptoms such as withdrawal, inattention, other externalizing problems and pervasive developmental problems in CBCL 1/2–5. The results confirmed our hypotheses by indicating a higher severity of sensory symptoms and identifying specific behavioral problems in children with RSPD. The results revealed convergent validity between the instruments and the diagnostic criteria for RSPD and supported the validity of RSPD as a unique diagnosis. The findings also suggested the importance of identifying sensory modulation deficits in order to develop an early intervention to enhance the sensory capacities of children who do not fully satisfy the criteria for some DSM-IV-TR disorders.