826 resultados para Rapid Screen
Resumo:
Drug combinations can improve angiostatic cancer treatment efficacy and enable the reduction of side effects and drug resistance. Combining drugs is non-trivial due to the high number of possibilities. We applied a feedback system control (FSC) technique with a population-based stochastic search algorithm to navigate through the large parametric space of nine angiostatic drugs at four concentrations to identify optimal low-dose drug combinations. This implied an iterative approach of in vitro testing of endothelial cell viability and algorithm-based analysis. The optimal synergistic drug combination, containing erlotinib, BEZ-235 and RAPTA-C, was reached in a small number of iterations. Final drug combinations showed enhanced endothelial cell specificity and synergistically inhibited proliferation (p < 0.001), but not migration of endothelial cells, and forced enhanced numbers of endothelial cells to undergo apoptosis (p < 0.01). Successful translation of this drug combination was achieved in two preclinical in vivo tumor models. Tumor growth was inhibited synergistically and significantly (p < 0.05 and p < 0.01, respectively) using reduced drug doses as compared to optimal single-drug concentrations. At the applied conditions, single-drug monotherapies had no or negligible activity in these models. We suggest that FSC can be used for rapid identification of effective, reduced dose, multi-drug combinations for the treatment of cancer and other diseases.
Resumo:
Tässä diplomityössä haluttiin mallintaa kuidutusrummun toimintaa Fluent virtausmallinusohjelman avulla. Aikaisempi tieto ja kehitystyö on perustunut kokemukseen ja käytännön kokeisiin. Kehitystyön alkuaikoina on suoritettu muutamia laskelmia koskien rummun tuottoa mutta sen jälkeen ei toimintaa ole laskennallisesti kuvattu. Työn ensimmäinen osa käsittelee yleisesti keräyspaperin käsittelyyn liittyviä laitteita ja menetelmiä. Toimintaperiaatteita on kuvattu yleisellä tasolla ja FibreFlow® rumpu on sitten käsitelty muita laitteita tarkemmin. Työn toinen osa sisältää sitten laboratoriotestit paikallisilta tahteilta hankittujen näytteiden viskositeettien ja tiheyksien määrittämiseksi. Kokeet suoritettiin Kemiantekniikan osastolla Brookfield viskoosimetrillä. Joitain alustavia laskentoja tuotosta suoritettiin aikaisempien tietojen perusteella. Rumpua kun on valmistettu vuodesta 1976, on tietoa kertynyt runsaasti vuosien mittaan. Laskelmia varten valittiin mallinnettavaksi alueeksi vain yksittäinen reikä sihdistä jolle laskettiin massavirta. Käytetyt laadut olivat OCC ja DIP. Myös eri rumpukoot otettiin jossain määrin huomioon.
Resumo:
Diplomityö on tehty Telecom Business Research Centerissä Lappeenrannassa. Toimialalle tyypillistä on tekniikan ja globaalien markkinoiden nopea kehitys, mikä edellyttää alan tuotekehitykseltä panostamista oikeisiin ideoihin, sekä niiden nopeaa ja joustavaa kehittämistä tuotteiksi. Tuotekehityksen alkuvaihe on johtamisen kannalta erityisen suuri haaste, koska ideoita on runsaasti, mutta resurssit tehdä niihin liittyviä selvityksiä ovat rajalliset. Diplomityön tavoitteena oli tuotekehityksen alkuvaiheen ymmärtäminen ja tutkia kuinka ideoita pystytään seulomaan. Tutkimus perustuu tuotekehityskirjallisuuteen ja haastatteluihin Telecom-teollisuudessa. Työn tuloksena ideoiden seulontaa kirjallisuudessa ja Telecom-teollisuudessa kuvataan ja niiden perusteella esitetään toimivia käytäntöjä tuotekehitysideoiden seulontaan toimialalla. Ehdotettujen käytäntöjen tavoitteena on saada parempia ideoita tehokkaammin tuotekehityksen alkuvaiheesta varsinaiseksi tuotekehitysprojektiksi.
Resumo:
Cognitive impairment in schizophrenia and psychosis is ubiquitous and acknowledged as a core feature of clinical expression, pathophysiology, and prediction of functioning. However, assessment of cognitive functioning is excessively time-consuming in routine practice, and brief cognitive instruments specific to psychosis would be of value. Two screening tools have recently been created to address this issue, i.e., the Brief Cognitive Assessment Tool for Schizophrenia (B-CATS) and the Screen for Cognitive Impairment in Psychiatry (SCIP). The aim of this research was to examine the comparative validity of these two brief instruments in relation to a global cognitive score. 161 patients with psychosis (96 patients diagnosed with schizophrenia and 65 patients diagnosed with bipolar disorder) and 76 healthy control subjects were tested with both instruments to examine their concurrent validity relative to a more comprehensive neuropsychological assessment battery. Scores from the B-CATS and the SCIP were highly correlated in the three diagnostic groups, and both scales showed good to excellent concurrent validity relative to a Global Cognitive Composite Score (GCCS) derived from the more comprehensive examination. The SCIP-S showed better predictive value of global cognitive impairment than the B-CATS. Partial and semi-partial correlations showed slightly higher percentages of both shared and unique variance between the SCIP-S and the GCCS than between the B-CATS and the GCCS. Brief instruments for assessing cognition in schizophrenia and bipolar disorders, such as the SCIP-S and B-CATS, seem to be reliable and promising tools for use in routine clinical practice.
Resumo:
BACKGROUND: Fever is a frequent cause of medical consultation among returning travelers. The objectives of this study were to assess whether physicians were able to identify patients with influenza and whether the use of an influenza rapid diagnostic test (iRDT) modified the clinical management of such patients. METHODS: Randomized controlled trial conducted at 2 different Swiss hospitals between December 2008 and November 2012. Inclusion criteria were 1) age ≥18 years, 2) documented fever of ≥38 °C or anamnestic fever + cough or sore throat within the last 4 days, 3) illness occurring within 14 days after returning from a trip abroad, 4) no definitive alternative diagnosis. Physicians were asked to estimate the likelihood of influenza on clinical grounds, and a single nasopharyngeal swab was taken. Thereafter patients were randomized into 2 groups: i) patients with iRDT (BD Directigen A + B) performed on the nasopharyngeal swab, ii) patients receiving usual care. A quantitative PCR to detect influenza was done on all nasopharyngeal swabs after the recruitment period. Clinical management was evaluated on the basis of cost of medical care, number of X-rays requested and prescription of anti-infective drugs. RESULTS: 100 eligible patients were referred to the investigators. 93 patients had a naso-pharyngeal swab for a PCR and 28 (30%) swabs were positive for influenza. The median probability of influenza estimated by the physician was 70% for the PCR positive cases and 30% for the PCR negative cases (p < 0.001). The sensitivity of the iRDT was only 20%, and specificity 100%. Mean medical cost for the patients managed with iRDT and without iRDT were USD 581 (95%CI 454-707) and USD 661 (95%CI 522-800) respectively. 14/60 (23%) of the patients managed with iRDT were prescribed antibiotics versus 13/33 (39%) in the control group (p = 0.15). No patient received antiviral treatment. CONCLUSION: Influenza was a frequent cause of fever among these febrile returning travelers. Based on their clinical assessment, physicians had a higher level of suspicion for influenza in PCR positive cases. The iRDT used in this study showed a disappointingly low sensitivity and can therefore not be recommended for the management of these patients. TRIAL REGISTRATION: ClinicalTrials.gov NCT00821626.
Resumo:
The present work describes the development of a fast and robust analytical method for the determination of 53 antibiotic residues, covering various chemical groups and some of their metabolites, in environmental matrices that are considered important sources of antibiotic pollution, namely hospital and urban wastewaters, as well as in river waters. The method is based on automated off-line solid phase extraction (SPE) followed by ultra-high-performance liquid chromatography coupled to quadrupole linear ion trap tandem mass spectrometry (UHPLC–QqLIT). For unequivocal identification and confirmation, and in order to fulfill EU guidelines, two selected reaction monitoring (SRM) transitions per compound are monitored (the most intense one is used for quantification and the second one for confirmation). Quantification of target antibiotics is performed by the internal standard approach, using one isotopically labeled compound for each chemical group, in order to correct matrix effects. The main advantages of the method are automation and speed-up of sample preparation, by the reduction of extraction volumes for all matrices, the fast separation of a wide spectrum of antibiotics by using ultra-high-performance liquid chromatography, its sensitivity (limits of detection in the low ng/L range) and selectivity (due to the use of tandem mass spectrometry) The inclusion of β-lactam antibiotics (penicillins and cephalosporins), which are compounds difficult to analyze in multi-residue methods due to their instability in water matrices, and some antibiotics metabolites are other important benefits of the method developed. As part of the validation procedure, the method developed was applied to the analysis of antibiotics residues in hospital, urban influent and effluent wastewaters as well as in river water samples
Resumo:
NlmCategory="UNASSIGNED">Rapid deployment aortic valve replacement (RDAVR) with the use of rapid deployment valve systems represents a smart alternative to the use of standard aortic bioprosthesis for aortic valve replacement. Nevertheless, its use is still debatable in patients with pure aortic valve regurgitation or true bicuspid aortic valve because of the risk of postoperative paravalvular leak. To address this issue, an optimal annulus-valve size match seems to be the ideal surgical strategy. This article describes a new technique developed to stabilize the aortic annulus and prevent paravalvular leak after RDAVR. To confirm the feasibility, this technique was performed in six patients with severe symptomatic aortic stenosis who were scheduled to undergo aortic valve replacement at our center. All patients survived surgery and were discharged from the hospital. There were no new intracardiac conduction system disturbances observed, and a permanent pacemaker implantation was not required in any of the patients. The intraoperative and postoperative echocardiogram confirmed successful positioning of the valve, and no paravalvular leak was observed. In this preliminary experience, RDAVR through a full sternotomy or an upper hemisternotomy approach with the use of aortic annulus stabilization technique was safe, and no leak was observed. Future studies on large series of patients are necessary to confirm the safety and effectiveness of this technique in preventing paravalvular leak in patients with true bicuspid aortic valves or pure aortic regurgitation.
Resumo:
To evaluate whether screening for hypertension should start early in life, information on the risk of diseases associated with the level of blood pressure in childhood or adolescence is needed. The study by Leiba et al. that is reported in the current issue of Pediatric Nephrology demonstrates convincingly that hypertensive adolescents are at higher risk of cardiovascular death than normotensive adolescents. Nevertheless, it can be shown that this excess risk is not sufficient to justify a screen-and-treat strategy. Since the large majority of cardiovascular deaths occur among normotensive adolescents, measures for primordial prevention of cardiovascular diseases could have a much larger impact at the population level.
Resumo:
We assessed knee extensor neuromuscular adjustments following repeated treadmill sprints in different normobaric hypoxia conditions, with special reference to rapid muscle torque production capacity. Thirteen team- and racquet-sport athletes undertook 8 × 5-s "all-out" sprints (passive recovery = 25 s) on a non-motorized treadmill in normoxia (NM; FiO2 = 20.9%), at low (LA; FiO2 = 16.8%) and high (HA; FiO2 = 13.3%) normobaric hypoxia (simulated altitudes of ~1800 m and ~3600 m, respectively). Explosive (~1 s; "fast" instruction) and maximal (~5 s; "hard" instruction) voluntary isometric contractions (MVC) of the knee extensors (KE), with concurrent electromyographic (EMG) activity recordings of the vastus lateralis (VL) and rectus femoris (RF) muscles, were performed before and 1-min post-exercise. Rate of torque development (RTD) and EMG (i.e., Root Mean Square or RMS) rise from 0 to 30, -50, -100, and -200 ms were recorded, and were also normalized to maximal torque and EMG values, respectively. Distance covered during the first 5-s sprint was similar (P > 0.05) in all conditions. A larger (P < 0.05) sprint decrement score and a shorter (P < 0.05) cumulated distance covered over the eight sprints occurred in HA (-8 ± 4% and 178 ± 11 m) but not in LA (-7 ± 3% and 181 ± 10 m) compared to NM (-5 ± 2% and 183 ± 9 m). Compared to NM (-9 ± 7%), a larger (P < 0.05) reduction in MVC torque occurred post-exercise in HA (-14 ± 9%) but not in LA (-12 ± 7%), with no difference between NM and LA (P > 0.05). Irrespectively of condition (P > 0.05), peak RTD (-6 ± 11%; P < 0.05), and normalized peak RMS activity for VL (-8 ± 11%; P = 0.07) and RF (-14 ± 11%; P < 0.01) muscles were reduced post-exercise, whereas reductions (P < 0.05) in absolute RTD occurred within the 0-100 (-8 ± 9%) and 0-200 ms (-10 ± 8%) epochs after contraction onset. After normalization to MVC torque, there was no difference in RTD values. Additionally, the EMG rise for VL muscle was similar (P > 0.05), whereas it increased (P < 0.05) for RF muscle during all epochs post-exercise, independently of the conditions. In summary, alteration in repeated-sprint ability and post-exercise MVC decrease were greater at high altitude than in normoxia or at low altitude. However, the post-exercise alterations in RTD were similar between normoxia and low-to-high hypoxia.
Resumo:
Bloodstream infections and sepsis are a major cause of morbidity and mortality. The successful outcome of patients suffering from bacteremia depends on a rapid identification of the infectious agent to guide optimal antibiotic treatment. The analysis of Gram stains from positive blood culture can be rapidly conducted and already significantly impact the antibiotic regimen. However, the accurate identification of the infectious agent is still required to establish the optimal targeted treatment. We present here a simple and fast bacterial pellet preparation from a positive blood culture that can be used as a sample for several essential downstream applications such as identification by MALDI-TOF MS, antibiotic susceptibility testing (AST) by disc diffusion assay or automated AST systems and by automated PCR-based diagnostic testing. The performance of these different identification and AST systems applied directly on the blood culture bacterial pellets is very similar to the performance normally obtained from isolated colonies grown on agar plates. Compared to conventional approaches, the rapid acquisition of a bacterial pellet significantly reduces the time to report both identification and AST. Thus, following blood culture positivity, identification by MALDI-TOF can be reported within less than 1 hr whereas results of AST by automated AST systems or disc diffusion assays within 8 to 18 hr, respectively. Similarly, the results of a rapid PCR-based assay can be communicated to the clinicians less than 2 hr following the report of a bacteremia. Together, these results demonstrate that the rapid preparation of a blood culture bacterial pellet has a significant impact on the identification and AST turnaround time and thus on the successful outcome of patients suffering from bloodstream infections.
Resumo:
We expose the ubiquitous interaction between an information screen and its’ viewers mobile devices, highlights the communication vulnerabilities, suggest mitigation strategies and finally implement these strategies to secure the communication. The screen infers information preferences’ of viewers within its vicinity transparently from their mobile devices over Bluetooth. Backend processing then retrieves up-to-date versions of preferred information from content providers. Retrieved content such as sporting news, weather forecasts, advertisements, stock markets and aviation schedules, are systematically displayed on the screen. To maximise users’ benefit, experience and acceptance, the service is provided with no user interaction at the screen and securely upholding preferences privacy and viewers anonymity. Compelled by the personal nature of mobile devices, their contents privacy, preferences confidentiality, and vulnerabilities imposed by screen, the service’s security is fortified. Fortification is predominantly through efficient cryptographic algorithms inspired by elliptic curves cryptosystems, access control and anonymity mechanisms. These mechanisms are demonstrated to attain set objectives within reasonable performance.