915 resultados para Pharmaceutical formulations


Relevância:

20.00% 20.00%

Publicador:

Resumo:

More than 3000 types of active pharmaceutical ingredients (APIs) are applied in Human and veterinary medicine practice. These compounds are considered an emergent class of environmental contaminants with the ability to cause damage and unexpected effects to aquatic organisms, namely in species of high commercial value. APIs are ubiquitous in the environment being frequently detected in influents and effluents of waste water treatment plants (WWTPs), surface waters and more distressingly in the public tap water in concentrations ranging from ng to μg.L-1. Considering these premises, the present thesis focused on APIs detection in the Arade river water, the impact of summer period in APIs’ concentration alterations applying the passive sampler device, POCIS (polar organic compound integrative sampler), as well as, the assessment of the effects caused by non-steroidal anti-inflammatory drugs (NSAID) ibuprofen (IBU) and diclofenac (DCF) and antidepressant selective serotonin reuptake inhibitor (SSRI) fluoxetine as single and mixture exposures along with a classical contaminant copper (Cu) on a non-target species, mussel Mytilus galloprovincialis. For this purpose, a multibiomarker approach was applied namely including biomarkers of oxidative stress (antioxidant enzymes activities of superoxide dismutase – SOD, catalase – CAT, glutathione reductase – GR and Phase II glutathione-S-transferase), damage - lipid peroxidation (LPO), neurotoxic effects (through the activity of acetylcholinesterase enzyme - AChE) and endocrine disruption (through vitellogenin-like proteins measurement applying the indirect method of alkali-labile phosphate - ALP) after exposure of mussel species’ to selected APIs at environmental relevant concentrations. The main results highlighted the occurrence of 19 APIs in the river Arade from several distinct therapeutic classes. Stimulant caffeine, antiasthmatic theophylline, NSAID ibuprofen and analgesic paracetamol presented the highest concentrations. Summer impact was inconclusive due to each API transient concentration in each month. The multibiomarker results revealed distinct responses towards each selected API (as single exposure or as mixtures) that were tissue and time dependent. Several multistressor interactions were proposed for each biomarker. The results also revealed APIs potential to induce oxidative stress, LPO, neurotoxicity and endocrine disruption even at extremely low concentrations on a species extremely vulnerable to APIs presence highlighting the urgency on the development of methodologies able to prevent its entrance in the aquatic environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de doutoramento, Farmácia (Tecnologia Farmacêutica), Universidade de Lisboa, Faculdade de Farmácia, 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de doutoramento, Farmácia (Tecnologia Farmacêutica), Universidade de Lisboa, Faculdade de Farmácia, 2015

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de doutoramento, Farmácia (Tecnologia Farmacêutica), Universidade de Lisboa, Faculdade de Farmácia, 2016

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A square-wave voltammetric (SWV) method and a flow injection analysis system with amperometric detection were developed for the determination of tramadol hydrochloride. The SWV method enables the determination of tramadol over the concentration range of 15-75 µM with a detection limit of 2.2 µM. Tramadol could be determined in concentrations between 9 and 50 µM at a sampling rate of 90 h-1, with a detection limit of 1.7 µM using the flow injection system. The electrochemical methods developed were successfully applied to the determination of tramadol in pharmaceutical dosage forms, without any pre-treatment of the samples. Recovery trials were performed to assess the accuracy of the results; the values were between 97 and 102% for both methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reduction of luvastatin (FLV) at a hanging mercury-drop electrode (HMDE) was studied by square-wave adsorptive-stripping voltammetry (SWAdSV). FLV can be accumulated and reduced at the electrode, with a maximum peak current intensity at a potential of approximately 1.26V vs. AgCl=Ag, in an aqueous electrolyte solution of pH 5.25. The method shows linearity between peak current intensity and FLV concentration between 1.0 10 8 and 2.7 10 6 mol L 1. Limits of detection (LOD) and quantification (LOQ) were found to be 9.9 10 9 mol L 1 and 3.3 10 8 mol L 1, respectively. Furthermore, FLV oxidation at a glassy carbon electrode surface was used for its hydrodynamic monitoring by amperometric detection in a flow-injection system. The amperometric signal was linear with FLV concentration over the range 1.0 10 6 to 1.0 10 5 mol L 1, with an LOD of 2.4 10 7 mol L 1 and an LOQ of 8.0 10 7 mol L 1. A sample rate of 50 injections per hour was achieved. Both methods were validated and showed to be precise and accurate, being satisfactorily applied to the determination of FLV in a commercial pharmaceutical.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical behavior of citalopram was studied by square-wave and square-wave adsorptive-stripping voltammetry (SWAdSV). Citalopram can be reduced and accumulated at a mercury drop electrode, with a maximum peak current intensity being obtained at a potential of approximately -1.25V vs. AgCl/Ag, in an aqueous electrolyte solution of pH 12. A SWAdSV method has been developed for the determination of citalopram in pharmaceutical preparations. The method shows a linear range between 1.0x10-7 and 2.0x10-6 mol L-1 with a limit of detection of 5x10-8 mol L-1 for an accumulation time of 30 s. The precision of the method was evaluated by assessing the repeatability and intermediate precision, achieving good relative standard deviations in all cases (≤2.3%). The proposed method was applied to the determination of citalopram in five pharmaceutical products and the results obtained are in good agreement with the labeled values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aiming the establishment of simple and accurate readings of citric acid (CA) in complex samples, citrate (CIT) selective electrodes with tubular configuration and polymeric membranes plus a quaternary ammonium ion exchanger were constructed. Several selective membranes were prepared for this purpose, having distinct mediator solvents (with quite different polarities) and, in some cases, p-tert-octylphenol (TOP) as additive. The latter was used regarding a possible increase in selectivity. The general working characteristics of all prepared electrodes were evaluated in a low dispersion flow injection analysis (FIA) manifold by injecting 500µl of citrate standard solutions into an ionic strength (IS) adjuster carrier (10−2 mol l−1) flowing at 3ml min−1. Good potentiometric response, with an average slope and a repeatability of 61.9mV per decade and ±0.8%, respectively, resulted from selective membranes comprising additive and bis(2-ethylhexyl)sebacate (bEHS) as mediator solvent. The same membranes conducted as well to the best selectivity characteristics, assessed by the separated solutions method and for several chemical species, such as chloride, nitrate, ascorbate, glucose, fructose and sucrose. Pharmaceutical preparations, soft drinks and beers were analyzed under conditions that enabled simultaneous pH and ionic strength adjustment (pH = 3.2; ionic strength = 10−2 mol l−1), and the attained results agreed well with the used reference method (relative error < 4%). The above experimental conditions promoted a significant increase in sensitivity of the potentiometric response, with a supra-Nernstian slope of 80.2mV per decade, and allowed the analysis of about 90 samples per hour, with a relative standard deviation <1.0%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work presented describes the development and evaluation of two flow-injection analysis (FIA) systems for the automated determination of carbaryl in spiked natural waters and commercial formulations. Samples are injected directly into the system where they are subjected to alkaline hydrolysis thus forming 1-naphthol. This product is readily oxidised at a glassy carbon electrode. The electrochemical behaviour of 1-naphthol allows the development of an FIA system with an amperometric detector in which 1-naphthol determination, and thus measurement of carbaryl concentration, can be performed. Linear response over the range 1.0×10–7 to 1.0×10–5 mol L–1, with a sampling rate of 80 samples h–1, was recorded. The detection limit was 1.0×10–8 mol L–1. Another FIA manifold was constructed but this used a colorimetric detector. The methodology was based on the coupling of 1-naphthol with phenylhydrazine hydrochloride to produce a red complex which has maximum absorbance at 495 nm. The response was linear from 1.0×10–5 to 1.5×10–3 mol L–1 with a detection limit of 1.0×10–6 mol L–1. Sample-throughput was about 60 samples h–1. Validation of the results provided by the two FIA methodologies was performed by comparing them with results from a standard HPLC–UV technique. The relative deviation was <5%. Recovery trials were also carried out and the values obtained ranged from 97.0 to 102.0% for both methods. The repeatability (RSD, %) of 12 consecutive injections of one sample was 0.8% and 1.6% for the amperometric and colorimetric systems, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ramsey pricing has been proposed in the pharmaceutical industry as a principle to price discriminate among markets while allowing to recover the (fixed) R&D cost. However, such analyses neglect the presence of insurance or the fund raising costs for most of drug reimbursement. By incorporating these new elements, we aim at providing some building blocks towards an economic theory incorporating Ramsey pricing and insurance coverage. We show how coinsurance affects the optimal prices to pay for the R&D investment. We also show that under certain conditions, there is no strategic incentive by governments to set coinsurance rates in order to shift the financial burden of R&D. This will have important implications to the application of Ramsey pricing principles to pharmaceutical products across countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Janssen-Cilag proposal for a risk-sharing agreement regarding bortezomib received a welcome signal from NICE. The Office of Fair Trading report included risk-sharing agreements as an available tool for the National Health Service. Nonetheless, recent discussions have somewhat neglected the economic fundamentals underlying risk-sharing agreements. We argue here that risk-sharing agreements, although attractive due to the principle of paying by results, also entail risks. Too many patients may be put under treatment even with a low success probability. Prices are likely to be adjusted upward, in anticipation of future risk-sharing agreements between the pharmaceutical company and the third-party payer. An available instrument is a verification cost per patient treated, which allows obtaining the first-best allocation of patients to the new treatment, under the risk sharing agreement. Overall, the welfare effects of risk-sharing agreements are ambiguous, and care must be taken with their use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As formulações de cloreto de sódio 0,9%, são na sua grande maioria utilizadas com bastante frequência sobretudo na população pediátrica. Tanto os cuidadores como os próprios profissionais de saúde as reconhecem e avaliam como um componente essencial para os cuidados de saúde desta população. No entanto, o grave problema destas formulações reside no facto de muitos dos consumidores após a sua utilização apresentarem reacções adversas, que não são justificáveis se apenas da composição da formulação fizerem parte água purificada e cloreto de sódio. Assim deve ser tida em conta a composição de cada apresentação farmacêutica, a fim de se averiguar quanto à presença de conservantes potencialmente perigosos e para deste modo alertar os possíveis consumidores destes produtos. O principal objectivo deste estudo foi a análise e avaliação da rotulagem e folheto de instruções das formulações de cloreto de sódio 0,9% para aplicação tópica em pediatria, a fim de se averiguar a utilização de conservantes na sua formulação e por conseguinte a sua conformidade para comercialização. Com o auxílio de uma check-list, foram avaliadas 34 apresentações de venda livre de formulações de cloreto de sódio 0,9% para aplicação tópica, no período de Janeiro a Março de 2014. Das 34 apresentações farmacêuticas analisadas, apenas uma dasapresentações não se encontrava descrita como dispositivo médico, mas sim como produto cosmético. Contudo quanto à marcação CE de conformidade, esta encontrava-se devidamente aposta em 94% das apresentações. No que às indicações terapêuticas diz respeito e como seria expectável, na sua maioria estas apresentações destinam-se em 51% dos casos para utilização nasal e em 33% dos casos para utilização oftálmica, sendo o modo de apresentação em gotas (88%) o mais encontrado para comercialização. Quanto à utilização de conservantes, constatou-se uma grande omissão e alguma imprecisão quanto às informações contidas na rotulagem e/ou folheto de instruções das formulações analisadas, expondo assim os indivíduos mais susceptíveis e em especial a população pediátrica ao risco de reacções adversas e que por vezes podem ser fatais. Por outro lado também podem ocorrer complicações aquando do uso inadvertido destasformulações com conservantes, por portadores de lentes de contacto ou sem a devida esterilidade para utilização oftálmica. Assim apesar de o soro fisiológico não ser considerado um medicamento, mas sim um dispositivo médico, deve ser contudo utilizado com algumas precauções, sobretudo nesta população pediátrica e sempre que possível aconselhado por um profissional treinado e consciente da problemática que os conservantes usados nestas formulações podem causar quando utilizados indevidamente.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada como requisito parcial para obtenção do grau de Mestre em Estatística e Gestão de Informação

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, biocompatible and biodegradable poly(D-L-lactide-co-glycolide) (PLGA) microparticles with the potential for use as a controlled release system of vaccines and other drugs to the lung were manufactured using supercritical CO2, through the Supercritical Assisted Atomization (SAA) technique. After performing a controlled variance in production parameters (temperature, pressure, CO2/solution flow ratio) PLGA microparticles were characterized and later used to encapsulate active pharmaceutical ingredients (API). Bovine serum albumin (BSA) was chosen as model protein and vaccine, while sildenafil was the chosen drug to treat pulmonary artery hypertension and their effect on the particles characteristics was evaluated. All the produced formulations were characterized in relation to their morphology (Morphologi G3 and scanning electronic microscopy (SEM)), to their physical-chemical properties (X-ray diffraction (XRD, differential scanning calorimetry (DSC), Fourier transform infrared (FTIR)) and aerodynamic performance using an in vitro aerosolization study – Andersen cascade impactor (ACI) - to obtain data such as the fine particle fraction (FPF) and the mass median aerodynamic diameter (MMAD). Furthermore, pharmacokinetic, biodegradability and biocompatibility tests were performed in order to verify the particle suitability for inhalation. The resulting particles showed aerodynamic diameters between the 3 and 5 μm, yields up to 58% and FPF percentages rounding the 30%. Taken as a whole, the produced microparticles do present the necessary requests to make them appropriate for pulmonary delivery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Skin exposures to chemicals may lead, through percutaneous permeation, to a significant increase in systemic circulation. Skin is the primary route of entry during some occupational activities, especially in agriculture. To reduce skin exposures, the use of personal protective equipment (PPE) is recommended. PPE efficiency is characterized as the time until products permeate through material (lag time, Tlag). Both skin and PPE permeations are assessed using similar in vitro methods; the diffusion cell system. Flow-through diffusion cells were used in this study to assess the permeation of two herbicides, bentazon and isoproturon, as well as four related commercial formulations (Basagran(®), Basamais(®), Arelon(®) and Matara(®)). Permeation was measured through fresh excised human skin, protective clothing suits (suits) (Microchem(®) 3000, AgriSafe Pro(®), Proshield(®) and Microgard(®) 2000 Plus Green), and a combination of skin and suits. Both herbicides, tested by itself or as an active ingredient in formulations, permeated readily through human skin and tested suits (Tlag < 2 h). High permeation coefficients were obtained regardless of formulations or tested membranes, except for Microchem(®) 3000. Short Tlag, were observed even when skin was covered with suits, except for Microchem(®) 3000. Kp values tended to decrease when suits covered the skin (except when Arelon(®) was applied to skin covered with AgriSafe Pro and Microgard(®) 2000), suggesting that Tlag alone is insufficient in characterizing suits. To better estimate human skin permeations, in vitro experiments should not only use human skin but also consider the intended use of the suit, i.e., the active ingredient concentrations and type of formulations, which significantly affect skin permeation.