998 resultados para Optical Sensitivity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim To compare the ability of scanning laser polarimeter (SLP) with variable corneal compensation (GDx VCC) and optical coherence tomograph (Stratus OCT) to discriminate between eyes with band atrophy (BA) of the optic nerve and healthy eyes. Methods The study included 37 eyes with BA and temporal visual field (VF) defects from chiasmal compression, and 29 normal eyes. Subjects underwent standard automated perimetry (SAP) and retinal nerve fibre layer (RNFL) scans using GDx VCC and Stratus OCT. The severity of the VF defects was evaluated by the temporal mean defect (TMD), calculated as the average of 22 values of the temporal total deviation plot on SAP. Receiver operating characteristic (ROC) curves were calculated. Pearson`s correlation coefficients were used to evaluate the relationship between RNFL thickness parameters and the TMD. Results No significant difference was found between the ROC curves areas (AUCs) for the GDx VCC and Stratus OCT with regard to average RNFL thickness (0.98 and 0.99, respectively) and the superior (0.94; 0.95), inferior (0.96; 0.97), and nasal (0.92; 0.96) quadrants. However, the AUC in the temporal quadrant (0.77) was significantly smaller (P < 0.001) with GDx VCC than with Stratus OCT (0.98). Lower TMD values were associated with smaller RNFL thickness in most parameters from both equipments. Conclusion Adding VCC resulted in improved performance in SLP when evaluating eyes with BA, and both technologies are sensitive in detecting average, superior, inferior, and nasal quadrant RNFL loss. However, GDx VCC still poorly discriminates RNFL loss in the temporal quadrant when compared with Stratus OCT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Several attempts to determine the transit time of a high dose rate (HDR) brachytherapy unit have been reported in the literature with controversial results. The determination of the source speed is necessary to accurately calculate the transient dose in brachytherapy treatments. In these studies, only the average speed of the source was measured as a parameter for transit dose calculation, which does not account for the realistic movement of the source, and is therefore inaccurate for numerical simulations. The purpose of this work is to report the implementation and technical design of an optical fiber based detector to directly measure the instantaneous speed profile of a (192)Ir source in a Nucletron HDR brachytherapy unit. Methods: To accomplish this task, we have developed a setup that uses the Cerenkov light induced in optical fibers as a detection signal for the radiation source moving inside the HDR catheter. As the (192)Ir source travels between two optical fibers with known distance, the threshold of the induced signals are used to extract the transit time and thus the velocity. The high resolution of the detector enables the measurement of the transit time at short separation distance of the fibers, providing the instantaneous speed. Results: Accurate and high resolution speed profiles of the 192Ir radiation source traveling from the safe to the end of the catheter and between dwell positions are presented. The maximum and minimum velocities of the source were found to be 52.0 +/- 1.0 and 17.3 +/- 1:2 cm/s. The authors demonstrate that the radiation source follows a uniformly accelerated linear motion with acceleration of vertical bar a vertical bar = 113 cm/s(2). In addition, the authors compare the average speed measured using the optical fiber detector to those obtained in the literature, showing deviation up to 265%. Conclusions: To the best of the authors` knowledge, the authors directly measured for the first time the instantaneous speed profile of a radiation source in a HDR brachytherapy unit traveling from the unit safe to the end of the catheter and between interdwell distances. The method is feasible and accurate to implement on quality assurance tests and provides a unique database for efficient computational simulations of the transient dose. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3483780]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate retinal nerve fiber layer (RNFL), optic nerve head (ONH), and macular thickness measurements for glaucoma detection using the RTVue spectral domain optical coherence tomograph. Design: Diagnostic, case-control study. Participants: One hundred forty eyes of 106 glaucoma patients and 74 eyes of 40 healthy subjects from the Diagnostic Innovations in Glaucoma Study (DIGS). Methods: All patients underwent ocular imaging with the commercially available RTVue. Optic nerve head, RNFL thickness, and macular thickness scans were obtained during the same visit. Receiver operating characteristic (ROC) curves and sensitivities at fixed specificities (80% and 95%) were calculated for each parameter. Main Outcome Measures: Areas under the ROC curves (AUC) and sensitivities at fixed specificities of 80% and 95%. Results: The AUC for the RNFL parameter with best performance, inferior quadrant thickness, was significantly higher than that of the best-performing ONH parameter, inferior rim area (0.884 vs 0.812, respectively; P = 0.04). There was no difference between ROC curve areas of the best RNFL thickness parameters and the best inner macular thickness measurement, ganglion cell complex root mean square (ROC curve area = 0.870). Conclusions: The RTVue RNFL and inner retinal macular thickness measurements had good ability to detect eyes with glaucomatous visual field loss and performed significantly better than ONH parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Selective serotonin reuptake inhibitors (SSRIs) are first-line treatments for posttraumatic stress disorder (PTSD). Serotonergic (5HT) attenuation of stress sensitivity is postulated from SSRIs` effects in other anxiety disorders, and we studied this in PTSD. Methods: Ten patients with PTSD fully recovered on SSRIs (Clinical Global Impression Scale-I 1 and 2) were enrolled in the study. Patients were tested on two occasions I week apart; in each session, they received a drink containing large neutral amino acids (LNAAs) either with (sham tryptophan depletion [STD], control) or without (acute tryptophan depletion [ATD]) tryptophan. At 5.5 hours after the drink, subjects were exposed to a trauma-related exposure challenge. Self-reports of PTSD (visual analogue scales [VAS] and the Davidson Trauma Scale [DTSI), anxiety (Spielberger State Inventory [STAI] Form Y-1), and mood (Profile of Mood States [POMS]) were obtained. Heart rate (HR), systolic (SBP) and diastolic (DBP) blood pressure were also measured. Results: The trauma-related exposure challenge induced anxiety on both days, with more marked responses on the ATD day according to VAS, DTS, POMS, and DBP (p < .05). A trend of significance (.1 > p >.05) was observed for STAI Form Y-1, HR, and SBP. Conclusions: These data demonstrate that ATD accentuates responses to trauma-related stimuli in SSRI-recovered PTSD. They also suggest that SSRI-induced increases in serotonin function restrain PTSD symptoms, especially under provocation, supporting a role for serotonin in mediating stress resilience.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the effects of administering rosiglitazone (RSG) vs pioglitazone (PIO) oil cardiovascular disease risk factors in insulin-resistant. nondiabetic individuals with no apparent disease. Twenty-two nondiabetic, apparently healthy individuals, classified as being insulin resistant oil the basis of a steady-state plasma glucose concentration of at least 10 mmol/L during the insulin suppression test, were treated with either RSG or 1110 for 3 months. Measurements were made before and after drug treatment of weight; blood pressure; fasting and daylong glucose, insulin, and free fatty acid (FFA) levels; and lipid and lipoprotein concentrations. Insulin sensitivity (steady-state plasma glucose concentration) significantly improved in both treatment groups, associated with significant decreases in daylong plasma concentrations of glucose, insulin, and FFA. Diastolic blood pressure fell somewhat in both groups, and this change reached significance in those receiving PIO. Improvement in lipid metabolism was confined to the PIO-treated group, signified by a significant decrease in plasma triglyceride concentration, whereas triglyceride concentration did not decline in the RSG-treated group, and these individuals also had increases in total (P = .047) and low-density lipoprotein cholesterol (P = .07). In conclusion, RSG and PIO appear to have comparable abilities to improve insulin sensitivity and lower daylong glucose, insulin, and FFA concentrations in nondiabetic, insulin-resistant individuals. However, despite these similarities, their effects on lipoprotein metabolism seem to be quite different, with beneficial effects confined to PIO-treated individuals. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The etiology of irritable bowel syndrome (IBS) is complex and multifaceted. Psychosocial factors play a role in such a process. Several reports suggest that IBS patients have increased psychopathology scores as compared with population controls. The influence of depressive symptoms on rectal sensitivity thresholds vary across different studies. The influence of predominant bowel habits on rectal sensitivity thresholds as determined by barostat-based investigations is not well established. The present report aimed to investigate the influence of depressive symptoms on rectal sensitivity in different subtypes of IBS patients (diarrhea/constipation-predominant vs. alternating subtypes). Depressive symptoms correlated well with first pain sensitivity threshold in alternating patients (n = 8; [rho] = -0.77; p = 0.02) but not in diarrhea/constipation predominant symptoms (n = 11; [rho] = -0.44; p = 0.27). These data suggest that depressive symptoms might impact pain thresholds differently according to the subtype of IBS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim Stapled haemorrhoidopexy may damage the anorectal musculature and its sensorimotor function. Most studies have not used a barostat for the measurement of compliance. This study aimed to investigate the effect of stapled haemorrhoidopexy on rectal compliance and sensitivity. Method After Ethical Committee approval, we studied 10 male patients (mean age 33.8 years) with third- or fourth-degree haemorrhoids. Rectal compliance and sensitivity were measured with a 600-ml bag and an electronic barostat. Volunteers were submitted to two consecutive rectal distension protocols, including continuous distension at 2, 4 and 6 months after stapled haemorrhoidopexy. Intraluminal volume and pressure were recorded, including the first rectal sensation, desire to defecate and onset of rectal pain. Another group of 10 male control patients (mean age 24.9 years) with pilonidal sinus and no haemorrhoids was also included in the study. Results Two months after stapled haemorrhoidopexy, rectal compliance decreased (7.1 +/- 0.2 vs 5.3 +/- 0.1, 6.4 +/- 0.1 vs 5.1 +/- 0.1 and 5.6 +/- 0.2 vs 4.7 +/- 0.1 ml/mmHg for first rectal sensation, desire to defecate and rectal pain, respectively; P < 0.05). The sensitivity threshold volume did not change for the first sensation but decreased significantly for the desier to defecate and pain (p < 0.05) (116.8 +/- 13.8 vs 148.4 +/- 14.61, 251.1 +/- 8.9 vs 185.8 +/- 8.6 and 293.3 +/- 16.6 vs 221.2 +/- 6.0 ml for first rectal sensation, desire to defecate and rectal pain, respectively). Four and 6 months after surgery, rectal compliance and sensitivity returned to levels similar to those in the basal period. Muscle tissue was found in only three of the 10 resected doughnuts. Controls remained without any change in rectal compliance and sensitivity. Conclusion Stapled haemorrhoidopexy transiently decreases rectal compliance and sensitivity threshold in young male patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study compared two heating methods currently used for antigen retrieval (AR) immunostaining: the microwave oven and the steam cooker. Myosin-V, a molecular motor involved in vesicle transport, was used as a neuronal marker in honeybee Apis mellifera brains fixed in formalin. Overall, the steam cooker showed the most satisfactory AR results. At 100 degrees C, tissue morphology was maintained and revealed epitope recovery, while evaporation of the AR solution was markedly reduced; this is important for stabilizing the sodium citrate molarity of the AR buffer and reducing background effects. Standardization of heat-mediated AR of formalin-fixed and paraffin-embedded tissue sections results in more reliable immunostaining of the honeybee brain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the advantages and disadvantages of the new low-addition (add) (+3.00 diopter [D]) ReSTOR multifocal IOL compared with the preceding ReSTOR model with +4.00 D add. SETTING: University Eye Hospital, Tuebingen, Germany. DESIGN: Comparative case series. METHODS: Patients with a +3.00 D or +4.00 D add multifocal IOL were examined for uncorrected and distance-corrected visual acuity at distance, intermediate, and near. A defocus profile was assessed, individual reading distance and the distance for lowest intermediate visual acuity were determined. Patient satisfaction was evaluated with a standardized questionnaire. Contrast sensitivity was tested under mesopic and photopic conditions. RESULTS: Uncorrected and distance-corrected intermediate visual acuities were statistically significantly better in the +3.00 D add group (24 eyes) than in the +4.00 D add group (30 eyes); distance and near visual acuities were not different between groups. The defocus profile significantly varied between groups. The +4.00 D add group had a closer reading distance (33.0 cm) than the +3.00 D add group (43.5 cm), a closer point of lowest intermediate visual acuity (65.8 cm versus 86.9 cm) and worse lowest intermediate visual acuity (20/59 +/- 4.5 letters [SD] versus 20/48 +/- 5.5 letters). Thus, patients in the +3.00 D add group reported being more satisfied with intermediate visual acuity. The +3.00 D add group reported more glare but less halos than the +4.00 D add group; contrast sensitivity was not different. CONCLUSION: The lower addition resulted in a narrower defocus profile, a farther reading distance, and better intermediate visual acuity and thus increased patient satisfaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Association between insulin resistance (IR) and non-alcoholic fatty liver disease (NAFLD) has been reported. This prompted us to evaluate the power of the insulin sensitivity index (ISI) in association with IGFBP-1 to identify IR early in obese children/adolescents. OGTT was performed in 34 obese/overweight children/adolescents. Glucose, insulin and IGFBP-1 were measured in serum samples and ISI was calculated. Considering the presence of three or more risk factors for IR as a criterion for IR, ISI <4.6 showed 87.5% sensitivity and 94.5% specificity in diagnosing IR. IGFBP-1 was lower in the group with ISI <4.6 (p <0.01). In this group, three patients had higher than expected IGFBP-1, suggesting hepatic IR, while three patients with ISI >4.6 showed very low IGFBP-1 levels. Conclusion: ISI <4.6 is a good indicator of early peripheral IR and, associated with IGFBP-1, can identify increased risk of hepatic IR. Low IGFBP-1 levels among non-IR children may indicate increased portal insulin levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The present study has investigated the effect of blockade of nitric oxide synthesis on cardiovascular autonomic adaptations induced by aerobic physical training using different approaches: 1) double blockade with methylatropine and propranolol; 2) systolic arterial pressure (SAP) and heart rate variability (HRV) by means of spectral analysis; and 3) baroreflex sensitivity. Methods: Male Wistar rats were divided into four groups: sedentary rats (SR); sedentary rats treated with N(omega)-nitro-L-arginine methyl ester (L-NAME) for one week (SRL); rats trained for eight weeks (TR); and rats trained for eight weeks and treated with L-NAME in the last week (TRL). Results: Hypertension and tachycardia were observed in SRL group. Previous physical training attenuated the hypertension in L-NAME-treated rats. Bradycardia was seen in TR and TRL groups, although such a condition was more prominent in the latter. All trained rats had lower intrinsic heart rates. Pharmacological evaluation of cardiac autonomic tonus showed sympathetic predominance in SRL group, differently than other groups. Spectral analysis of HRV showed smaller low frequency oscillations (LF: 0.2-0.75 Hz) in SRL group compared to other groups. Rats treated with L-NAME presented greater LF oscillations in the SAP compared to non-treated rats, but oscillations were found to be smaller in TRL group. Nitric oxide synthesis inhibition with L-NAME reduced the baroreflex sensitivity in sedentary and trained animals. Conclusion: Our results showed that nitric oxide synthesis blockade impaired the cardiovascular autonomic adaptations induced by previous aerobic physical training in rats that might be, at least in part, ascribed to a decreased baroreflex sensitivity. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Epidemiological studies report confidence or uncertainty intervals around their estimates. Estimates of the burden of diseases and risk factors are subject to a broader range of uncertainty because of the combination of multiple data sources and value choices. Sensitivity analysis can be used to examine the effects of social values that have been incorporated into the design of the disability–adjusted life year (DALY). Age weight, where a year of healthy life lived at one age is valued differently from at another age, is the most controversial value built into the DALY. The discount rate, which addresses the difference in value of current versus future health benefits, also has been criticized. The distribution of the global disease burden and rankings of various conditions are largely insensitive to alternate assumptions about the discount rate and age weighting. The major effects of discounting and age weighting are to enhance the importance of neuropsychiatric conditions and sexually transmitted infections. The Global Burden of Disease study also has been criticized for estimating mortality and disease burden for regions using incomplete and uncertain data. Including uncertain results, with uncertainty quantified to the extent possible, is preferable, however, to leaving blank cells in tables intended to provide policy makers with an overall assessment of burden of disease. No estimate is generally interpreted as no problem. Greater investment in getting the descriptive epidemiology of diseases and injuries correct in poor countries will do vastly more to reduce uncertainty in disease burden assessments than a philosophical debate about the appropriateness of social value