995 resultados para Image diagnosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reviews the literature for lowering of dose to paediatric patients through use of exposure factors and additional filtration. Dose reference levels set by The International Commission on Radiological Protection (ICRP) will be considered. Guidance was put in place in 1996 requires updating to come into line with modern imaging equipment. There is a wide range of literature that specifies that grids should not be used on paediatric patients. Although much of the literature advocates additional filtration, contrasting views on the relative benefits of using aluminium or copper filtration, and their effects on dose reduction and image quality can vary. Changing kVp and mAs has an effect on the dose to the patient and image quality. Collimation protects adjacent structures whilst reducing scattered radiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine whether using different combinations of kVp and mAs with additional filtration can reduce the effective dose to a paediatric phantom whilst maintaining diagnostic image quality. Methods: 27 images of a paediatric AP pelvis phantom were acquired with different kVp, mAs and additional copper filtration. Images were displayed on quality controlled monitors with dimmed lighting. Ten diagnostic radiographers (5 students and 5 experienced radiographers) had eye tests to assess visual acuity before rating the images. Each image was rated for visual image quality against a reference image using 2 alternative forced choice software using a 5-point Likert scale. Physical measures (SNR and CNR) were also taken to assess image quality. Results: Of the 27 images rated, 13 of them were of acceptable image quality and had a dose lower than the image with standard acquisition parameters. Two were produced without filtration, 6 with 0.1mm and 5 with 0.2mm copper filtration. Statistical analysis found that the inter-rater and intra-rater reliability was high. Discussion: It is possible to obtain an image of acceptable image quality with a dose that is lower than published guidelines. There are some areas of the study that could be improved. These include using a wider range of kVp and mAs to give an exact set of parameters to use. Conclusion: Additional filtration has been identified as amajor tool for reducing effective dose whilst maintaining acceptable image quality in a 5 year old phantom.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the field of appearance-based robot localization, the mainstream approach uses a quantized representation of local image features. An alternative strategy is the exploitation of raw feature descriptors, thus avoiding approximations due to quantization. In this work, the quantized and non-quantized representations are compared with respect to their discriminativity, in the context of the robot global localization problem. Having demonstrated the advantages of the non-quantized representation, the paper proposes mechanisms to reduce the computational burden this approach would carry, when applied in its simplest form. This reduction is achieved through a hierarchical strategy which gradually discards candidate locations and by exploring two simplifying assumptions about the training data. The potential of the non-quantized representation is exploited by resorting to the entropy-discriminativity relation. The idea behind this approach is that the non-quantized representation facilitates the assessment of the distinctiveness of features, through the entropy measure. Building on this finding, the robustness of the localization system is enhanced by modulating the importance of features according to the entropy measure. Experimental results support the effectiveness of this approach, as well as the validity of the proposed computation reduction methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Information obtained from the routine application of hydatid immunodiagnostic techniques in different clinical situations over a seven-year period is presented. The Immunoelectrophoresis test was used until it was replaced by the simpler, more sensitive and equally specific arc 5 double diffusion (DD5) test. Examination of sera from 1,888 patients with signs and/or symptoms compatible with hydatid disease revealed that the presurgical confirmation of Echinococcus granulosus infection is only obtained by detection of anti-antigen 5 antibodies. The latter were not found in 1,539 presumptive hydatidosis patients whose definitive diagnoses corresponded to other disease conditions. However, false positive latex agglutination test results were obtained in two cases. In all patients whose preoperative serum showed three or more uncharacteristic bands in the absence of anti-antigen 5 antibodies, hydatid cysts were found sur gically. DD5 testing of a fluid sample collected by puncture established its hydatid etiology. Post-operative monitoring of hydatidosis patients demonstrated that persistence of DD5-positivity two years after surgery established the presence of other cysts. Further evidence was obtained in patients with hydatid cysts in intrathoracic, abdominal or other locations associating cyst membrane integrity, antigen release and immunodiagnostic test positivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Química - Ramo Tecnologias de Protecção Ambiental

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twenty patients with prolonged septicemic salmonellosis (Group 1) and 20 with schistosomiasis mansoni (Group 2) were selected for this study. In both groups, the Widal test was done using antigens of the sample Ty 901 (S. typhi). The test was also applied in 6 group 1 patients with antigens prepared from salmonellae isolated from these patients (autoantigens). Titres over 1:200 were considered significant. Ten group 1 patients (50%) were positive for antigen "H" and 5 (25%) were positive for antigen "O". Three patients with negative "H" and "O" reactions became positive with high titres when using autoantigens. Two other cases maintained the same positive titres and one case showed a fourfold increase in titres when the test was done 'with antigens of the Salmonella isolated. The Widal test was positive in most patients infected with group D Salmonellae. Considering titres above 1:200, all cases were negative in Group 2. The authors conclude that the Widal test has low positivity in prolonged septicemic salmonellosis. The test may be valuable in the diagnosis of this disease when using S. paratyphi "A" and "B" antigens and a mixture of Salmonella antigens taken from other groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brain dopamine transporters imaging by Single Emission Tomography (SPECT) with 123I-FP-CIT (DaTScanTM) has become an important tool in the diagnosis and evaluation of Parkinson syndromes.This diagnostic method allows the visualization of a portion of the striatum – where healthy pattern resemble two symmetric commas - allowing the evaluation of dopamine presynaptic system, in which dopamine transporters are responsible for dopamine release into the synaptic cleft, and their reabsorption into the nigrostriatal nerve terminals, in order to be stored or degraded. In daily practice for assessment of DaTScan TM, it is common to rely only on visual assessment for diagnosis. However, this process is complex and subjective as it depends on the observer’s experience and it is associated with high variability intra and inter observer. Studies have shown that semiquantification can improve the diagnosis of Parkinson syndromes. For semiquantification, analysis methods of image segmentation using regions of interest (ROI) are necessary. ROIs are drawn, in specific - striatum - and in nonspecific – background – uptake areas. Subsequently, specific binding ratios are calculated. Low adherence of semiquantification for diagnosis of Parkinson syndromes is related, not only with the associated time spent, but also with the need of an adapted database of reference values for the population concerned, as well as, the examination of each service protocol. Studies have concluded, that this process increases the reproducibility of semiquantification. The aim of this investigation was to create and validate a database of healthy controls for Dopamine transporters with DaTScanTM named DBRV. The created database has been adapted to the Nuclear Medicine Department’s protocol, and the population of Infanta Cristina’s Hospital located in Badajoz, Spain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The latest medical diagnosis devices enable the performance of e-diagnosis making the access to these services easier, faster and available in remote areas. However this imposes new communications and data interchange challenges. In this paper a new XML based format for storing cardiac signals and related information is presented. The proposed structure encompasses data acquisition devices, patient information, data description, pathological diagnosis and waveform annotation. When compared with similar purpose formats several advantages arise. Besides the full integrated data model it may also be noted the available geographical references for e-diagnosis, the multi stream data description, the ability to handle several simultaneous devices, the possibility of independent waveform annotation and a HL7 compliant structure for common contents. These features represent an enhanced integration with existent systems and an improved flexibility for cardiac data representation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A serologic study was undertaken in a group of 43 patients with active paracoccidioidomycosis who were treated in the same form (ketoconazole), for identical periods of time (6 months), and folio wed-up for various periods posttherapy. The tests employed were agar gel immunodiffusion (AGID) and complement fixation (FC). Also studied were 50 sera from patients with proven histoplasmosis and pulmonary aspergilloma, 30 patients with culturaly proven tuberculosis as well as 92 specimens from healthy individuals, residents in the endemic area for paracoccidioidomycosis. A single lot of yeast filtrate antigen was used throughout the study. The value of each test was measured according to GALEN and GAMBINO6. Both tests were highly sensitive, 89 and 93% respectively. Regarding their specificity, the AGID was totally specific while the CF exhibited 96.6% and 97% specificity in front of tuberculosis patients and healthy individuals respectively and 82% in comparison with patients with other mycoses. The concept of predictive value, that is, the certainty one has in accepting a positive test as diagnostic of paracoccidioidomycosis, favored the AGID procedure (100%) over the CF test. The latter could sort out with 93% certainty a patient with paracoccidioidomycosis among a group of healthy individuals and with 97.5% in the case of TB patients; when the group in question was composed by individuals with other deep mycoses, such certainty was lower (81%). The above results indicate that both the AGID and the CF tests furnish results of high confidence; one should not relay, however, in the CF alone as a means to establish the specific diagnosis of paracoccidioidomycosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lectins were labeled with fluorescein and tried as conjugates in the immunofluorescence (IP) test for the detection of IgM antibodies to T. gondii, in the diagnosis of acute toxoplasmosis. This approach was an attempt to find alternative reagents for anti-human IgM fluorescent conjugates (AHIgMFC), which contain quite frequently anaibcdies to toxoplasma, as contaminants, due to natural T. gondii infections among animals used for imunization. Lentil (Lens culinaris) lectin fluorescence conjugates (LcFC) provided most satisfactory results. The evaluation of LcFC carried out in a total of 179 sera from patients with acute and chronic toxoplasmosis, with non-related infections or healthy subjects, gave high values of relative efficiency, co-positivity and co-negativity indices, respectively 0.989, 0.969 and 1.000, in reference to the conventional AHIgMFC. Moreover, three batches of LcFC successively prepared gave reproducible test results. The advantage of LcFC as an alternative reagent for the serodiagnosis of acute toxoplasmosis is supported by practical aspects of its preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose - To develop and validate a psychometric scale for assessing image quality for chest radiographs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Urinary tract infection (UTI) is one of the most prevalent pathologies in developed countries, particularly in women, characterized by the presence of bacterial growth in any part of the urinary system. Currently, urine culture is considered the gold standard method for the diagnosis of UTI. However, this method has several disadvantages including the time necessary for obtaining the results and the associated high costs. Therefore, it is important to evaluate new efficient and valuable methods for the diagnosis of these infections. Objectives: Presently, dipsticks are considered a possible valuable alternative to urine culture. This method has very low costs associated and the results can be obtained in few minutes. Here we aim to compare the sensibility, specificity, predictive value of a positive test and a negative test of both methods in order to determine the efficiency of the test strips method and also to characterize the microorganism more frequently isolated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and effective dose for pelvis using automatic exposure control (AEC) and non-AEC in a computed radiography (CR) system. Methods and Materials: To determine the effects of using AEC and non-AEC by applying the 10 kVp rule in two experiments using an anthropomorphic pelvis phantom. Images were acquired using 10 kVp increments (60-120 kVp) for both experiments. The first experiment, based on seven AEC combinations, produced 49 images. The mean mAs from each kVp increment were used as a baseline for the second experiment producing 35 images. A total of 84 images were produced and a panel of 5 experienced observers participated for the image scoring using the 2 AFC visual grading software. PCXMC software was used to estimate the effective dose. Results: A decrease in perceptual image quality as the kVp increases was observed both in non-AEC and AEC experiments, however no significant statistical differences (p> 0.05) were found. Image quality scores from all observers at 10 kVp increments for all mAs values using non-AEC mode demonstrates a better score up to 90 kVp. Effective dose results show a statistical significant decrease (p=0.000) on the 75th quartile from 0.3 mSv at 60 kVp to 0.1 mSv at 120 kVp when applying the 10 kVp rule in non-AEC mode. Conclusion: No significant reduction in perceptual image quality is observed when increasing kVp whilst a marked and significant effective dose reduction is observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sensitivity, specificity and positive predictive values of selected clinical signs and symptoms in the diagnosis of Schistosoma mansoni infection were evaluated in 403 individuals (69% of inhabitants over 1 year of age) in an endemic area in Brazil (Divino). Highest sensitivity (13%) was found for blood in stools. Specificity over 90% was found for blood in stools, palpable liver with normal consistency and palpable hardened liver at middle clavicular (MCL) or middle sternal lines (MSL). Hardened liver at MSL (83%) or MCL (75%), and blood in stools (78%) presented higher positive predictive values for S. mansoni infection, while palpable liver with normal consistency at MCL (45%) or MSL (48%) presented smaller values. Enlarged liver without specification of its consistency has been traditionally used as an indicator of the infection in areas where malaria or Kalazar are not endemic. Our results demonstrate that the probability that a person with blood in stools or hardened palpable liver is infected is higher than among those with palpable liver with normal consistency.