945 resultados para High frequency chest wall oscillation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We consider laminar high-Reynolds-number flow through a finite-length planar channel, where a portion of one wall is replaced by a thin massless elastic membrane that is held under longitudinal tension T and subject to an external pressure distribution. The flow is driven by a fixed pressure drop along the full length of the channel. We investigate the global stability of two-dimensional Poiseuille flow using a method of matched local eigenfunction expansions, which is compared to direct numerical simulations. We trace the neutral stability curve of the primary oscillatory instability of the system, illustrating a transition from high-frequency ‘sloshing’ oscillations at high T to vigorous ‘slamming’ motion at low T . Small-amplitude sloshing at high T can be captured using a low-order eigenmode truncation involving four surface-based modes in the compliant segment of the channel coupled to Womersley flow in the rigid segments. At lower tensions, we show that hydrodynamic modes contribute increasingly to the global instability and we demonstrate a change in the mechanism of energy transfer from the mean flow, with viscous effects being destabilising. Simulations of finite-amplitude oscillations at low T reveal a generic slamming motion, in which the the flexible membrane is drawn close to the opposite rigid wall before rapidly recovering. A simple model is used to demonstrate how fluid inertia in the downstream rigid channel segment, coupled to membrane curvature downstream of the moving constriction, together control slamming dynamics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To evaluate the prevalence and hygiene habits of 13-19 years-old adolescent users of removable orthodontic appliances (ROA) and to determine hygiene methods for the appliances prescribed by dentists, in the city of Pelotas. Methods: The study had two stages. The first stage was a telephone interview with dentists. Dentists were interview by telephone calls in order to obtain information regarding the hygiene methods for cleaning acrylic appliances. Second stage was a cross-sectional study performed with schoolchildren. Children from public and private schools with secondary level were included in the sample. A questionnaire was applied to the students using any type of ROA. Questionnaires included demographic information and behavioral characteristics. Data collected were subjected to Chi-square test and logistic regression. Results: The prevalence of children using ROA was 5.4%. Students (89.7%) and dentists (47.2%) reported to prefer mechanical methods to clean their ROA. Cleaning with soup, hydrogen peroxide or effervescent tabs were less used. High frequency of use was associated with higher frequency of hygiene on the ROA. Conclusions: The prevalence of schoolchildren using removable appliances was low. The common cleaning method used by children and prescribed by dentists was mechanical. Hygiene frequency was significantly associated with the routine of use of the appliance and with the type of hygiene method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Doutoramento em Economia

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objetivo: Analizar el manejo del trauma de tórax en el Hospital Vicente Corral Moscoso y describir las características demográficas de la población estudiada. Método: Estudio descriptivo retrospectivo, la muestra fue de 167 pacientes atendidos en el servicio de Emergencia del Hospital Vicente Corral Moscoso, con diagnóstico de trauma de tórax, durante el periodo enero de 2013 a junio de 2015; los datos se obtuvieron de las historias clínicas. Se analizaron las variables de datos demográficos y tratamiento, utilizando frecuencias, porcentajes y chi cuadrado. Se empleó el programa SPSS versión 18, Excel 2010. Resultados: La edad promedio fue de 37 años, con mayor frecuencia en varones con el 84.4%. Los diagnósticos fueron: hemotórax 36.53%, neumotórax 25.75%, hemoneumotórax 27.54%. El 4.8% de los pacientes recibió tratamiento no quirúrgico, el 82.6% avenamiento pleural; al 12.6% se practicó toracotomías al ingreso. Al 19.8% se realizó toracotomía durante la estancia hospitalaria debido a complicaciones como el hemotórax coagulado o residual. La mortalidad fue del 5.4% (9 pacientes), 7 presentaron lesiones extra torácicas. Conclusiones: El trauma de tórax se presentó en alto porcentaje en la tercera década de vida y se resolvió mayormente con avenamiento pleural. Las lesiones extra torácicas incrementan la mortalidad y necesitan un manejo multidisciplinario.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An 18-year time series of daily sea surface temperature of Gulf of Cadiz and an 18-month time series of temperature collected in the vicinity of the Guadalquivir estuary mouth have been analyzed to investigate the heat exchange between the estuary and the adjacent continental shelf. The first time identifies a continental shelf area where seasonal thermal oscillation signal (amplitudes and phase) changes abruptly. In order to explain this anomaly, the second data set allows a description of thermal fluctuations in a wide range of frequencies and an estimation of the upstream heat budget of the Guadalquivir estuary. Results show that high frequency thermal signal, diurnal and semidiurnal, and water flux signal through Guadalquivir mouth, mainly semidiurnal, apparently interact randomly to give a small exchange of thermal energy at high frequency. There is no trace, at the estuary's mouth, of daily heat exchanges with intertidal mudflats probably because it tends to cancel on daily time scales. Results also show that fluctuations of estimated air-sea fluxes force fluctuations of temperature in a quite homogeneous estuarine, with a delay of 20 days. The along-channel thermal energy gradient reaches magnitudes of 300-400 J m-4 near the mouth during the summer and winter and drives the estuary-shelf exchange of thermal energy at seasonal scale. Particularly, the thermal heat imported by the estuary from the shelf area during late fall-winter-early spring of 2008/2009 is balanced by the thermal heat that the estuary exports to the shelf area during late spring-summer of 2008. In summary, Guadalquivir river removes/imports excess of thermal energy towards/from the continental shelf seasonally, as a mechanism to accommodate excess of heat from one side respect to the other side.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The thesis deals with the experimental investigation of turbulent pipe flow at high Reynolds number. Wall-bounded turbulence is an extremely relevant topic for engineering and natural science applications and yet many aspects of the physics are not clear due to the difficulty in performing high Re experiments. To overcome these difficulties the CICLoPE Laboratory was developed, the main element of which is the Long Pipe wind tunnel. The facility is unique in its kind, as thanks to its large scale it delivers a flow quality and resolution that can not be achieved elsewhere at these Reynolds number. Reported here are the results from the first experimental campaign performed in the facility. A first part of the results presented concerns the characterization of this new facility. Flow quality and stability are assessed, particular attention is given to the characterization of pressure drop. The scaling of velocity fluctuations is analysed. The magnitude of the inner peak of the streamwise normal stress shows an increasing trend up to the highest Reynolds number examined, while no outer peak was clearly distinguishable from present measurements. Scaling of coherent motions is investigated via spectral analysis. An inner and outer spectral peaks are identified, with the former scaling in inner units while the latter neither following inner nor outer scaling, and increasing in magnitude with Re. Analysis of the spectra at y+ ≈ 15 shows how the increase of Reynolds normal stress is related to the influence of large scales in the inner wall region. Quadrant analysis was carried out on streamwise and wall-normal velocity fluctuations. The results show the important role in contribution to Reynolds shear stress of highly intermittent and strong events like ejections, that assume an even more intermittent and dominant role with the increase of Reynolds number.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As future technologies are going to be autonomous under the umbrella of the Internet of things (IoT) we can expect WPT to be the solution for intelligent devices. WPT has many industrial and medical applications both in the near-field and far-field domains. Considering the impact of WPT, this thesis is an attempt to design and realize both near-field and far-field WPT solutions for different application scenarios. A 27 MHz high frequency inductive wireless power link has been designed together with the Class-E switching inverter to compensate for the efficiency loss because of the varying weak coupling between transmitter and receiver because of their mutual misalignment. Then a system of three coils was introduced for SWIPT. The outer coil for WPT and the inner two coils were designed to fulfil the purpose of communication and testing, operating at frequencies different from the WPT coil. In addition to that, a trapping filter technique has also been adopted to ensure the EM isolation of the coils. Moreover, a split ring resonator-based dual polarization converter has been designed with good efficiency over a wide frequency range. The gap or cuts have been introduced in the adjacent sides of the square ring to make it a dual-polarization converter. The converter is also stable over a wide range of incident angles. Furthermore, a meta-element based intelligent surface has been designed to work in the reflection mode at 5 GHz. In this research activity, interdigital capacitors (IDCs) instead of ICs are introduced and a thin layer of the HfZrO between substrate and meta elements is placed whose response can be tuned and controlled with the applied voltage to achieve IRS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nowadays, electrical machines are seeing an ever-increasing development and extensive research is currently being dedicated to the improvement of their efficiency and torque/power density. Compared to conventional random windings, hairpin winding inherently features lower DC resistance, higher fill factor, better thermal performance, improved reliability, and an automated manufacturing process. However, several challenges need to be addressed, including electromagnetic, thermal, and manufacturing aspects. Of these, the high ohmic losses at high-frequency operations due to skin and proximity effects are the most severe, resulting in low efficiency or high-temperature values. In this work, the hairpin winding challenges were highlighted at high-frequency operations and at showing the limits of applicability of these standard approaches. Afterward, a multi-objective design optimization is proposed aiming to enhance the exploitation of the hairpin technology in electrical machines. Efficiency and volume power density are considered as main design objectives. Subsequently, a changing paradigm is made for the design of electric motors equipped with hairpin windings, where it is proven that a temperature-oriented approach would be beneficial when designing this type of pre-formed winding. Furthermore, the effect of the rotor topology on AC losses is also considered. After providing design recommendations and FE electromagnetic and thermal evaluations, experimental tests are also performed for validation purposes on a motorette wound with pre-formed conductors. The results show that operating the machine at higher temperatures could be beneficial to efficiency, particularly in high-frequency operations where AC losses are higher at low operating temperatures. The last part of the thesis focuses on comparing the main electromagnetic performance metrics for a conventional hairpin winding, wound onto a benchmark stator with a semi-closed slot opening design, and a continuous hairpin winding, in which the slot opening is open. Lastly, the adoption of semi-magnetic slot wedges is investigated to improve the overall performance of the motor.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents the experimental development of a novel heat treatment for a high performance Laser Powder Bed Fusion Ti6Al4V alloy. Additive manufacturing production processes for titanium alloys are particularly of interest in cutting-edge engineering fields, however, high frequency laser induced thermal cycles generate a brittle as built microstructure. For this reason, heat treatments compliant with near net shape components are needed before their homologation and usage. The experimental campaign focused on the development of a multi-step heat treatment leading to a bilamellar microstructure. In fact, according to literature, such a microstructure should be promising in terms of mechanical properties both under static and cyclic loads. The heat treatment development has asked for the preliminary analyses of samples annealed and aged in laboratory, implementing several cycles, differing for what concerns temperatures, times and cooling rates. Such a characterization has been carried out through optical and electron microscopy analyses, image analyses, hardness and tensile tests. As a result, the most suitable thermal cycle has been selected and performed using industrial equipment on mini bending fatigue samples with different surface conditions. The same tests have been performed on a batch of traditionally treated samples, to provide with a comparison. This master thesis activity has finally led to the definition of a heat treatment resulting into a bilamellar microstructure, promising in terms of fatigue performances with respect to the traditionally treated alloy ones. The industrial implementation of such a heat treatment will require further improvements, particularly for what concerns the post annealing water quench, in order to prevent any surface alteration potentially responsible for the fatigue performances drop. Further development of the research may also include push-pull fatigue tests, crack grow propagation and residual stresses analyses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the modified US7 score (MUS7 score SYN) in the assessment of patients with early rheumatoid arthritis (ERA). In addition, dorsal and palmar recesses of the wrists as well as of small joints of the hands and feet were examined for the presence of synovitis by means of a global assessment of joints. The study sample comprised 32 patients treated for arthritis, with an average disease duration of 13 months. An ultrasound machine with high frequency transducer was used. Hands were also X-rayed and analysed by Larsen score. Out of the 832 examined joints, synovitis was detected in 173 (20,79%), tenosynovitis in 22 (4,91%), and erosions in 3 (1,56%). Synovitis was predominantly detected in the dorsal recess (73,38%) of MCP and PIP joints, when compared with palmar recess (26%). The presence of synovitis in the joints evaluated correlated with clinical (HAQ-DI, DAS28), laboratory (ACPA, RF, CRP), and ultrasound results (r = 0,37 to r = 0,42; p = 0,04 to p = 0,003). We found correlation of the MUS7 score SYN of the gray scale US or of the power Doppler US with DAS28 (PCR) values (r = 0,38; p = 0,0332), and with CRP results (r = 0,39; p = 0,0280), respectively. The dorsal recess, the wrist, and small joints can be considered as important sites to detect synovitis by the MUS7 score SYN in patients with ERA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fibrodysplasia ossificans progressiva is a rare genetic disease characterized by widespread soft tissue ossification and congenital stigmata of the extremities. We report on a male child followed for ten years since the age of 3 years and 9 months, when the diagnosis was made. He was born with bilateral hypoplasic hallux valgus and ventricular septal defect, corrected by transsternal approach when 32 months old. Restriction of neck mobility followed and foci of ectopic ossification appeared. Four crises of disease exacerbation were treated with oral prednisone and/or other antiinflammatory drugs. Sodium etidronate 5 to 10 mg/kg/day was prescribed intermittently during about six years but was discontinued due to osteopenia. The disease course has been relentless, with severe movement restriction including the chest wall. A review showed few similar case reports in the Brazilian literature. We revisit the criteria for diagnosis and the essentials of management and treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O presente trabalho versa sobre o diagnóstico e a abordagem ortodôntica das anomalias dentárias, enfatizando os aspectos etiológicos que definem tais irregularidades de desenvolvimento. Parece existir uma inter-relação genética na determinação de algumas dessas anomalias, considerando-se a alta frequência de associações. Um mesmo defeito genético pode originar diferentes manifestações fenotípicas, incluindo agenesias, microdontias, ectopias e atraso no desenvolvimento dentário. As implicações clínicas das anomalias dentárias associadas são muito relevantes, uma vez que o diagnóstico precoce de uma determinada anomalia dentária pode alertar o clínico sobre a possibilidade de desenvolvimento de outras anomalias associadas no mesmo paciente ou em outros membros da família, permitindo a intervenção ortodôntica em época oportuna.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A ocorrência de aflatoxina B1 (AFB1) em rações e aflatoxina M1 (AFM1) no leite cru foi avaliada em propriedades leiteiras situadas na região nordeste do Estado de São Paulo, Brasil, de outubro de 2005 a fevereiro de 2006. A análise de aflatoxinas foi efetuada utilizando-se colunas de imunoafinidade para purificação dos extratos, sendo a quantificação realizada através de cromatografia líquida de alta eficiência. A AFB1 foi detectada em 40% das rações em níveis de 1,0 a 19,5 μg.kg-1. A concentração de AFM1 em 36,7% de amostras de leite positivas variou de 0,010 a 0,645 μg.L-1. Somente uma amostra de leite estava acima do limite de tolerância adotado no Brasil (0,5 μg.L-1) para AFM1. Concluiu-se que as concentrações de aflatoxinas na ração e no leite foram relativamente baixas, embora a alta frequência das aflatoxinas nas amostras analisadas indique a necessidade de contínuo monitoramento a fim de prevenir a contaminação de ingredientes e rações destinadas ao gado leiteiro.