988 resultados para Field intensity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate rates of visual field progression in eyes with optic disc hemorrhages and the effect of intraocular pressure (IOP) reduction on these rates. Design: Observational cohort study. Participants: The study included 510 eyes of 348 patients with glaucoma who were recruited from the Diagnostic Innovations in Glaucoma Study (DIGS) and followed for an average of 8.2 years. Methods: Eyes were followed annually with clinical examination, standard automated perimetry visual fields, and optic disc stereophotographs. The presence of optic disc hemorrhages was determined on the basis of masked evaluation of optic disc stereophotographs. Evaluation of rates of visual field change during follow-up was performed using the visual field index (VFI). Main Outcome Measures: The evaluation of the effect of optic disc hemorrhages on rates of visual field progression was performed using random coefficient models. Estimates of rates of change for individual eyes were obtained by best linear unbiased prediction (BLUP). Results: During follow-up, 97 (19%) of the eyes had at least 1 episode of disc hemorrhage. The overall rate of VFI change in eyes with hemorrhages was significantly faster than in eyes without hemorrhages (-0.88%/year vs. -0.38%/year, respectively, P < 0.001). The difference in rates of visual field loss pre- and post-hemorrhage was significantly related to the reduction of IOP in the post-hemorrhage period compared with the pre-hemorrhage period (r = -0.61; P < 0.001). Each 1 mmHg of IOP reduction was associated with a difference of 0.31%/year in the rate of VFI change. Conclusions: There was a beneficial effect of treatment in slowing rates of progressive visual field loss in eyes with optic disc hemorrhage. Further research should elucidate the reasons why some patients with hemorrhages respond well to IOP reduction and others seem to continue to progress despite a significant reduction in IOP levels. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2010; 117: 2061-2066 (C) 2010 by the American Academy of Ophthalmology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: We aimed to investigate the efficacy of 20 Hz repetitive transcranial magnetic stimulation (rTMS) of either right or left dorsolateral prefrontal cortex (DLPFC) as compared to sham rTMS for the relief of posttraumatic stress disorder (PTSD)-associated symptoms. Method: In this double-blind, placebo-controlled phase II trial conducted between October 2005 and July 2008, 30 patients with DSM-IV-diagnosed PTSD were randomly assigned to receive 1 of the following treatments: active 20 Hz rTMS of the right DLPFC, active 20 Hz rTMS of the left DLPFC, or sham rTMS. Treatments were administered in 10 daily sessions over 2 weeks. A blinded rater assessed severity of core PTSD symptoms, depression, and anxiety before, during, and after completion of the treatment protocol. In addition, a battery of neuropsychological tests was measured before and after treatment. Results: Results show that both active conditions-20 Hz rTMS of left and right DLPFC induced a significant decrease in PTSD symptoms as indexed by the PTSD Checklist and Treatment Outcome PTSD Scale; however, right rTMS induced a larger effect as compared to left rTMS. In addition, there was a significant improvement of mood after left rTMS and a significant reduction of anxiety following right rTMS. Improvements in PTSD symptoms were long lasting; effects were still significant at the 3-month follow-up. Finally, neuropsychological evaluation showed that active 20 Hz rTMS is not associated with cognitive worsening and is safe for use in patients with PTSD. Conclusions: These results support the notion that modulation of prefrontal cortex can alleviate the core symptoms of PTSD and suggest that high-frequency rTMS of right DLPFC might be the optimal treatment strategy. J an Psychiatry 2010;71(8):992-999 (C) Copyright 2009 Physicians Postgraduate Press, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To propose an analytic framework for ocular fundus alterations in late-stage Vogt,Koyanagi-Harada (VKH) disease, to describe the characteristics of overall retinal function as measured with full field electroretinography (ERG), and to correlate the intensity of the fundus changes with full-field ERG alterations and to stratify patients accordingly. DESIGN: Cross-sectional case series. METHODS: Forty-seven eyes of 26 patients with late, stage VKH disease (> 6 months past disease onset) followed-up at the University of Sao Paulo School of Medicine underwent fundus photography within 2 months of a full,field ERG examination, both according to pre-defined protocols. Fundus pictures were evaluated by two observers regarding diffuse fundus depigmentation, nummular lesions, pigment clumps, and subretinal fibrosis, and an overall analysis classified the fundus changes as mild, moderate, or severe. Full field ERG results were analyzed according to fundus-based stratification and also were stratified into 3 groups solely on the basis of decreasing amplitudes (ERG based or cluster stratification). The concordance between fundus-based and full-field ERG-based stratification strategies was estimated. RESULTS: Overall fundus grading showed substantial interobserver concordance (kappa = 0.78). Comparison of full field ERG parameters of the three fundus based stratified groups showed diffusely diminished amplitudes with preservation of implicit times (P < .05). Fundus-based and full-field ERG-based stratification strategies also showed substantial concordance (kappa = 0.68). CONCLUSIONS: The analytic framework for fundus findings proposed in this study seems reproducible and useful, because the severity categories do correlate with retinal function as measured by full-field ERG. This system may allow more precise exchange of information between practitioners as well as researchers with regard to identifying patients with greater retinal compromise rapidly as well as in comparison of outcomes of different treatment regimens. (Am J Ophthalmol 2009;148: 939-945. (C) 2009 by Elsevier Inc. All rights reserved.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STUDY DESIGN: Controlled laboratory study. OBJECTIVE: To evaluate the effect of low-intensity therapeutic ultrasound on the murine calcaneus tendon healing process. BACKGROUND: Therapeutic ultrasound promotes formation and maturation of scar tissue. METHODS: Calcaneus tendon tenotomy and tenorrhaphy was performed on 28 Wistar rats. After the procedure, the animals were randomly divided into 2 groups. The animals in the experimental group received a 5-minute ultrasound application, once a day, at a frequency of 1 MHz, a spatial average temporal average intensity of 0.1 W/cm(2), and a spatial average intensity of 0.52 W/cm(2) at a 16-Hz frequency pulse mode (duty cycle, 20%). Data for the injured side were normalized in relation to the data from the contralateral healthy calcaneus tendon (relative values). The animals in the control group received sham treatment. After a 28-day treatment period, the animals were sacrificed and their tendons surgically removed and subjected to mechanical stress testing. The parameters analyzed were cross-sectional area (mm(2)), ultimate load (N), tensile strength (MPa), and energy absorption (mJ). RESULTS: A significant difference between groups was found for the relative values of ultimate load and tensile strength. The mean +/- SD ultimate load of the control group was -3.5% +/- 32.2% compared to 33.3% +/- 26.8% for the experimental group (P = .005). The mean tensile strength of the control group was -47.7% +/- 19.5% compared to -28.1% +/- 24.1% for the experimental group (P = .019). No significant difference was found in cross-sectional area and energy absorption. CONCLUSION: Low-intensity pulsed ultrasound produced by a conventional therapeutic ultrasound unit can positively influence the calcaneus tendon healing process in rats. J Ort hop Sports Phys Ther 2011;41(7):526-531, Epub 2 February 2011. doi:10.2519/jospt.2011.3468

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Transcutaneous electrical nerve stimulation (TENS) is an effective adjunctive therapy for postoperative pain; however, effects of different frequencies Of stimulation have not been systematically investigated. Laparoscopic sterilization (LS) causes significant pain in the early postoperative period and requires substantial postoperative medication. Therefore, we studied the effects of TENS on postoperative pain after LS through placement of Yoon fallopian rings in a prospective, randomized, double-blinded, and placebo-controlled study. Methods: Sixty-four patients undergoing LS for uterine tube ligation were randomly allocated to receive either active TENS or placebo TENS. Postoperative pain was evaluated using a standard I I-point numeric rating scale and the McGill Pain Questionnaire (MPQ)-pain rating index and number of words chosen. Both high frequency (100 Hz) and low frequency (4 Hz) TENS, at strong, but comfortable sensory intensity, were applied for 20 minutes through 4 electrodes placed around the surgical incision immediately after Surgery. Pain was assessed before and after application of TENS when patients were at postanesthesia care unit (PACU). Results: Both high and low frequency TENS significantly decreased postoperative pain intensity when compared with before administration of TENS using the numeric rating scale (P = 0.001), pain rating index (P = 0.001), and number of words chosen (P 0.001) compared with placebo TENS (P = 0.001). TENS in combination with standard pharmacologic analgesic treatment was efficacious for postoperative pain relief after LS. Conclusions: We recommend regular use of multimodal therapy with TENS and analgesic drugs after LS with placement of Yoon rings.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We assessed the repair of transverse, 3-mm wide bone gaps created at the distal radius in 28 dogs that were randomly divided into two 14-animal groups; one was the control group and the other received a daily, 20-min application of low-intensity pulsed ultrasound for 100 days. Sequential radiographs, histomorphometrics, bone fluorescent histology and bone vascularity assessments found that all animals from both groups obtained a stage of hypertrophic-type nonunion with fibrocartilage tissue formation throughout the region of osteotomy. However, treated animals exhibited areas of endochondral ossification within the fibrocartilage region. There was no difference in type of vascularity or the newly formed bone process obtained by tetracycline labeling. Application of low-intensity ultrasound was not capable of significantly changing the reparative process and it may not be sufficiently powerful to overcome a combination of local deleterious effects on bone healing, created by gapping, excessive motion and periosteal resection. (E-mail: jbvolpon@fmrp.usp.br) (C) 2010 World Federation for Ultrasound in Medicine & Biology.