995 resultados para Drugs -- Testing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The room temperature (RT) tensile behaviour of a free-standing high activity Pt-aluminide bond coat has been evaluated by microtensile testing technique. The coating had a typical three-layer microstructure. The stress-strain plot for the free-standing coating was linear, indicating the coating to be brittle at RT. Different fracture features were observed across the coating layers, namely quasi-cleavage in the outer layer and inner interdiffusion zone, and cleavage in the intermediate layer. By employing interrupted tensile test and observing the cross-sectional microstructure of the tested specimens, it was determined that failure of the microtensile samples occurred by the initiation of a single crack in the intermediate layer of the coating and its subsequent inside-out propagation. Such a mechanism of failure has been explained in terms of the fracture features observed across the sample thickness. This mechanism of failure is consistent with fracture toughness values of the individual coating layers. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Continuous epidural analgesia (CEA) and continuous spinal postoperative analgesia (CSPA) provided by a mixture of local anaesthetic and opioid are widely used for postoperative pain relief. E.g., with the introduction of so-called microcatheters, CSPA found its way particularly in orthopaedic surgery. These techniques, however, may be associated with dose-dependent side-effects as hypotension, weakness in the legs, and nausea and vomiting. At times, they may fail to offer sufficient analgesia, e.g., because of a misplaced catheter. The correct position of an epidural catheter might be confirmed by the supposedly easy and reliable epidural stimulation test (EST). The aims of this thesis were to determine a) whether the efficacy, tolerability, and reliability of CEA might be improved by adding the α2-adrenergic agonists adrenaline and clonidine to CEA, and by the repeated use of EST during CEA; and, b) the feasibility of CSPA given through a microcatheter after vascular surgery. Studies I IV were double-blinded, randomized, and controlled trials; Study V was of a diagnostic, prospective nature. Patients underwent arterial bypass surgery of the legs (I, n=50; IV, n=46), total knee arthroplasty (II, n=70; III, n=72), and abdominal surgery or thoracotomy (V, n=30). Postoperative lumbar CEA consisted of regular mixtures of ropivacaine and fentanyl either without or with adrenaline (2 µg/ml (I) and 4 µg/ml (II)) and clonidine (2 µg/ml (III)). CSPA (IV) was given through a microcatheter (28G) and contained either ropivacaine (max. 2 mg/h) or a mixture of ropivacaine (max. 1 mg/h) and morphine (max. 8 µg/h). Epidural catheter tip position (V) was evaluated both by EST at the moment of catheter placement and several times during CEA, and by epidurography as reference diagnostic test. CEA and CSPA were administered for 24 or 48 h. Study parameters included pain scores assessed with a visual analogue scale, requirements of rescue pain medication, vital signs, and side-effects. Adrenaline (I and II) had no beneficial influence as regards the efficacy or tolerability of CEA. The total amounts of epidurally-infused drugs were even increased in the adrenaline group in Study II (p=0.02, RM ANOVA). Clonidine (III) augmented pain relief with lowered amounts of epidurally infused drugs (p=0.01, RM ANOVA) and reduced need for rescue oxycodone given i.m. (p=0.027, MW-U; median difference 3 mg (95% CI 0 7 mg)). Clonidine did not contribute to sedation and its influence on haemodynamics was minimal. CSPA (IV) provided satisfactory pain relief with only limited blockade of the legs (no inter-group differences). EST (V) was often related to technical problems and difficulties of interpretation, e.g., it failed to identify the four patients whose catheters were outside the spinal canal already at the time of catheter placement. As adjuvants to lumbar CEA, clonidine only slightly improved pain relief, while adrenaline did not provide any benefit. The role of EST applied at the time of epidural catheter placement or repeatedly during CEA remains open. The microcatheter CSPA technique appeared effective and reliable, but needs to be compared to routine CEA after peripheral arterial bypass surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent technical advances have enabled for the first time, reliable in vitro culture of prostate cancer samples as prostate cancer organoids. This breakthrough provides the significant possibility of high throughput drug screening covering the spectrum of prostate cancer phenotypes seen clinically. These advances will enable precision medicine to become a reality, allowing patient samples to be screened for effective therapeutics ex vivo, with tailoring of treatments specific to that individual. This will hopefully lead to enhanced clinical outcomes, avoid morbidity due to ineffective therapies and improve the quality of life in men with advanced prostate cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Technical or contaminated ethanol products are sometimes ingested either accidentally or on purpose. Typical misused products are black-market liquor and automotive products, e.g., windshield washer fluids. In addition to less toxic solvents, these liquids may contain the deadly methanol. Symptoms of even lethal solvent poisoning are often non-specific at the early stage. The present series of studies was carried out to develop a method for solvent intoxication breath diagnostics to speed up the diagnosis procedure conventionally based on blood tests. Especially in the case of methanol ingestion, the analysis method should be sufficiently sensitive and accurate to determine the presence of even small amounts of methanol from the mixture of ethanol and other less-toxic components. In addition to the studies on the FT-IR method, the Dräger 7110 evidential breath analyzer was examined to determine its ability to reveal a coexisting toxic solvent. An industrial Fourier transform infrared analyzer was modified for breath testing. The sample cell fittings were widened and the cell size reduced in order to get an alveolar sample directly from a single exhalation. The performance and the feasibility of the Gasmet FT-IR analyzer were tested in clinical settings and in the laboratory. Actual human breath screening studies were carried out with healthy volunteers, inebriated homeless men, emergency room patients and methanol-intoxicated patients. A number of the breath analysis results were compared to blood test results in order to approximate the blood-breath relationship. In the laboratory experiments, the analytical performance of the Gasmet FT-IR analyzer and Dräger 7110 evidential breath analyzer was evaluated by means of artificial samples resembling exhaled breath. The investigations demonstrated that a successful breath ethanol analysis by Dräger 7110 evidential breath analyzer could exclude any significant methanol intoxication. In contrast, the device did not detect very high levels of acetone, 1-propanol and 2-propanol in simulated breath. The Dräger 7110 evidential breath ethanol analyzer was not equipped to recognize the interfering component. According to the studies the Gasmet FT-IR analyzer was adequately sensitive, selective and accurate for solvent intoxication diagnostics. In addition to diagnostics, the fast breath solvent analysis proved feasible for controlling the ethanol and methanol concentration during haemodialysis treatment. Because of the simplicity of the sampling and analysis procedure, non-laboratory personnel, such as police officers or social workers, could also operate the analyzer for screening purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an experimental investigation on the lateral impact performance of axially loaded concrete-filled double-skin tube (CFDST) columns. These columns have desirable structural and constructional properties and have been used as columns in building, legs of off shore platforms and as bridge piers. Since they could be vulnerable to impact from passing vessels or vehicles, it is necessary to understand their behaviour under lateral impact loads. With this in mind, an experimental method employing an innovative instrumented horizontal impact testing system (HITS) was developed to apply lateral impact loads whilst the column maintained a static axial pre-loading to examine the failure mechanism and key response parameters of the column. These included the time histories of impact force, reaction forces, global lateral deflection and permanent local buckling profile. Eight full scale columns were tested for key parameters including the axial load level and impact location. Based on the test data, the failure mode, peak impact force, impact duration, peak reaction forces, reaction force duration, column maximum and residual global deflections and column local buckling length, depth and width under varying conditions are analysed and discussed. It is evident that the innovative HITS can successfully test structural columns under the combination of axial pre-loading and impact loading. The findings on the lateral impact response of the CFDST columns can serve as a benchmark reference for their future analysis and design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rest tremor, rigidity, and slowness of movements-considered to be mainly due to markedly reduced levels of dopamine (DA) in the basal ganglia-are characteristic motor symptoms of Parkinson's disease (PD). Although there is yet no cure for this illness, several drugs can alleviate the motor symptoms. Among these symptomatic therapies, L-dopa is the most effective. As a precursor to DA, it is able to replace the loss of DA in the basal ganglia. In the long run L-dopa has, however, disadvantages. Motor response complications, such as shortening of the duration of drug effect ("wearing-off"), develop in many patients. In addition, extensive peripheral metabolism of L-dopa by aromatic amino acid decarboxylase and catechol-O-methyltransferase (COMT) results in its short half-life, low bioavailability, and reduced efficacy. Entacapone, a nitrocatechol-structured compound, is a highly selective, reversible, and orally active inhibitor of COMT. It increases the bioavailability of L-dopa by reducing its peripheral elimination rate. Entacapone extends the duration of clinical response to each L-dopa dose in PD patients with wearing-off fluctuations. COMT is important in the metabolism of catecholamines. Its inhibition could, therefore, theoretically lead to adverse cardiovascular reactions, especially in circumstances of enhanced sympathetic activity (physical exercise). PD patients may be particularly vulnerable to such effects due to high prevalence of cardiovascular autonomic dysfunction, and the common use of monoamine oxidase B inhibitor selegiline, another drug with effects on catecholamine metabolism. Both entacapone and selegiline enhance L-dopa's clinical effect. Their co-administration may therefore lead to pharmacodynamic interactions, either beneficial (improved L-dopa efficacy) or harmful (increased dyskinesia). We investigated the effects of repeated dosing (3-5 daily doses for 1-2 weeks) of entacapone 200 mg administered either with or without selegiline (10 mg once daily), on several safety and efficacy parameters in 39 L-dopa-treated patients with mild to moderate PD in three double-blind placebo-controlled, crossover studies. In the first two, the cardiovascular, clinical, and biochemical responses were assessed repeatedly for 6 hours after drug intake, first with L-dopa only (control), and then after a 2 weeks on study drugs (entacapone vs. entacapone plus selegiline in one; entacapone vs. selegiline vs. entacapone plus selegiline in the other). The third study included cardiovascular reflex and spiroergometric exercise testing, first after overnight L-dopa withdrawal (control), and then after 1 week on entacapone plus selegiline as adjuncts to L-dopa. Ambulatory ECG was recorded in two of the studies. Blood pressure, heart rate, ECG, cardiovascular autonomic function, cardiorespiratory exercise responses, and the resting/exercise levels of circulating catecholamines remained unaffected by entacapone, irrespective of selegiline. Entacapone significantly enhanced both L-dopa bioavailability and its clinical response, the latter being more pronounced with the co-administration of selegiline. Dyskinesias were also increased during simultaneous use of both entacapone and selegiline as L-dopa adjuncts. Entacapone had no effect on either work capacity or work efficiency. The drug was well tolerated, both with and without selegiline. Conclusions: the use of entacapone-either alone or combined with selegiline-seems to be hemodynamically safe in L-dopa-treated PD patients, also during maximal physical effort. This is in line with the safety experience from larger phase III studies. Entacapone had no effect on cardiovascular autonomic function. Concomitant administration of entacapone and selegiline may enhance L-dopa's clinical efficacy but may also lead to increased dyskinesia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The keto-enol type tautomerism in anti-thyroid drugs and their selenium analogues are described. The commonly used anti-thyroid drug methimazole exists predominantly in its thione form, whereas its selenium analogue exists in a zwitterionic form. To understand the effect of thione/thiol and selone/selenol tautomerism on the inhibition of peroxidase-catalysed reactions, we have synthesized some thiones and selones in which the formation of thiol/selenol forms are blocked by different substituents. These compounds were synthesized by a carbene route utilizing an imidazolium salt. The crystal structures of these compounds reveal that the C=Se bonds in the selones are more polarized than the C=S bonds in the corresponding thiones. The structures of selones were studied in solution by NMR spectroscopy and the 77Se NMR chemical shifts for the selones show large upfield shifts in the signals, confirming their zwitterionic structures in solution. The inhibition of lactoperoxidase by the synthetic thiones indicates that the presence of a free N-H moiety is essential for an efficient inhibition. In contrast, such moiety is not required for an inhibition by the selenium compounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnetorheological dampers are intrinsically nonlinear devices, which make the modeling and design of a suitable control algorithm an interesting and challenging task. To evaluate the potential of magnetorheological (MR) dampers in control applications and to take full advantages of its unique features, a mathematical model to accurately reproduce its dynamic behavior has to be developed and then a proper control strategy has to be taken that is implementable and can fully utilize their capabilities as a semi-active control device. The present paper focuses on both the aspects. First, the paper reports the testing of a magnetorheological damper with an universal testing machine, for a set of frequency, amplitude, and current. A modified Bouc-Wen model considering the amplitude and input current dependence of the damper parameters has been proposed. It has been shown that the damper response can be satisfactorily predicted with this model. Second, a backstepping based nonlinear current monitoring of magnetorheological dampers for semi-active control of structures under earthquakes has been developed. It provides a stable nonlinear magnetorheological damper current monitoring directly based on system feedback such that current change in magnetorheological damper is gradual. Unlike other MR damper control techniques available in literature, the main advantage of the proposed technique lies in its current input prediction directly based on system feedback and smooth update of input current. Furthermore, while developing the proposed semi-active algorithm, the dynamics of the supplied and commanded current to the damper has been considered. The efficiency of the proposed technique has been shown taking a base isolated three story building under a set of seismic excitation. Comparison with widely used clipped-optimal strategy has also been shown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The autonomic nervous system is an important modulator of ventricular repolarization and arrhythmia vulnerability. This study explored the effects of cardiovascular autonomic function tests on repolarization and its heterogeneity, with a special reference to congenital arrhythmogenic disorders typically associated with stress-induced fatal ventricular arrhythmias. The first part explored the effects of standardized autonomic tests on QT intervals in a 12-lead electrocardiogram and in multichannel magnetocardiography in 10 healthy adults. The second part studied the effects of deep breathing, Valsalva manouvre, mental stress, sustained handgrip and mild exercise on QT intervals in asymptomatic patients with LQT1 subtype of the hereditary long QT syndrome (n=9) and in patients with arrhythmogenic right ventricular dysplasia (ARVD, n=9). Even strong sympathetic activation had no effects on spatial QT interval dispersion in healthy subjects, but deep respiratory efforts and Valsalva influenced it in ways that were opposite in electrocardiographic and magnetocardiographic recordings. LQT1 patients showed blunted QT interval and sinus nodal responses to sympathetic challenge, as well as an exaggerated QT prolongation during the recovery phases. LQT1 patients showed a QT interval recovery overshoot in 2.4 ± 1.7 tests compared with 0.8 ± 0.7 in healthy controls (P = 0.02). Valsalva strain prolonged the T wave peak to T wave end interval only in the LQT1 patients, considered to reflect the arrhythmogenic substrate in this syndrome. ARVD patients showed signs of abnormal repolarization in the right ventricle, modulated by abrupt sympathetic activation. An electrocardiographic marker reflecting interventricular dispersion of repolarization was introduced. It showed that LQT1 patients exhibit a repolarization gradient from the left ventricle towards the right ventricle, significantly larger than in controls. In contrast, ARVD patients showed a repolarization gradient from the right ventricle towards the left. Valsalva strain amplified the repolarization gradient in LQT1 patients whereas it transiently reversed it in patients with ARVD. In conclusion, intrathoracic volume and pressure changes influence regional electrocardiographic and magnetocardiographic QT interval measurements differently. Especially recovery phases of standard cardiovascular autonomic functions tests and Valsalva manoeuvre reveal the abnormal repolarization in asymptomatic LQT1 patients. Both LQT1 and ARVD patients have abnormal interventricular repolarization gradients, modulated by abrupt sympathetic activation. Autonomic testing and in particular the Valsalva manoeuvre are potentially useful in unmasking abnormal repolarization in these syndromes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the effect of some commonly used antithyroid drugs and their analogues on peroxynitrite-mediated nitration of proteins is described. The nitration of tyrosine residues in bovine serum albumin (BSA) and cytochromec was studied by Western blot analysis. These studies reveal that the antithyroid drugs methimazole (MMI), 6-n-propyl-2-thiouracil (PTU), and 6-methyl-2-thiouracil (MTU), which contain thione moieties, significantly reduce the tyrosine nitration of both BSA and cytochrome c. While MMI exhibits good peroxynitrite (PN) scavenging activity, the thiouracil compounds PTU and MTU are slightly less effective than MMI. The S- and Se-methylated compounds show a weak inhibitory effect in the nitration of tyrosine, indicating that the presence of a thione or selone moiety is important for an efficient inhibition. Similarly, the replacement of N-H moiety in MMI by N-methyl or N-m-methoxybenzyl substituents dramatically reduces the antioxidant activity of the parent compound. Theoretical studies indicate that the substitution of N-H moiety by N-Me significantly increases the energy required for the oxidation of sulfur center by PN. However, such substitution in the selenium analogue of MMI increases the activity of parent compound. This is due to the facile oxidation of the selone moiety to the corresponding selenenic and seleninic acids. Unlike N,N'-disubstituted thiones, the corresponding selones efficiently scavenge PN, as they predominantly exist in their zwitterionic forms in which the selenium atom carries a large negative charge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Organic anion-transporting polypeptide 1B1 (OATP1B1), encoded by the SLCO1B1 gene, is an influx transporter expressed on the sinusoidal membrane of human hepatocytes. The common c.521T>C (p.Val174Ala) single-nucleotide polymorphism (SNP) of the SLCO1B1 gene has been associated with reduced OATP1B1 transport activity in vitro and increased plasma concentrations of several of its substrate drugs in vivo in humans. Another common SNP of the SLCO1B1 gene, c.388A>G (p.Asn130Asp), defining the SLCO1B1*1B (c.388G-c.521T) haplotype, has been associated with increased OATP1B1 transport activity in vitro. The aim of this thesis was to investigate the role of SLCO1B1 polymorphism in the pharmacokinetics of the oral antidiabetic drugs repaglinide, nateglinide, rosiglitazone, and pioglitazone. Furthermore, the effect of the SLCO1B1 c.521T>C SNP on the extent of interaction between gemfibrozil and repaglinide as well as the role of the SLCO1B1 c.521T>C SNP in the potential interaction between atorvastatin and repaglinide were evaluated. Five crossover studies with 2-4 phases were carried out, with 20-32 healthy volunteers in each study. The effects of the SLCO1B1 c.521T>C SNP on single doses of repaglinide, nateglinide, rosiglitazone, and pioglitazone were investigated in Studies I and V. In Study II, the effects of the c.521T>C SNP on repaglinide pharmacokinetics were investigated in a dose-escalation study, with repaglinide doses ranging from 0.25 to 2 mg. The effects of the SLCO1B1*1B/*1B genotype on repaglinide and nateglinide pharmacokinetics were investigated in Study III. In Study IV, the interactions of gemfibrozil and atorvastatin with repaglinide were evaluated in relation to the c.521T>C SNP. Plasma samples were collected for drug concentration determinations. The pharmacodynamics of repaglinide and nateglinide was assessed by measuring blood glucose concentrations. The mean area under the plasma repaglinide concentration-time curve (AUC) was ~70% larger in SLCO1B1 c.521CC participants than in c.521TT participants (P ≤ 0.001), but no differences existed in the pharmacokinetics of nateglinide, rosiglitazone, and pioglitazone between the two genotype groups. In the dose-escalation study, the AUC of repaglinide was 60-110% (P ≤ 0.001) larger in c.521CC participants than in c.521TT participants after different repaglinide doses. Moreover, the AUC of repaglinide increased linearly with repaglinide dose in both genotype groups (r > 0.88, P 0.001). The AUC of repaglinide was ~30% lower in SLCO1B1*1B/*1B participants than in SLCO1B1*1A/*1A (c.388AA-c.521TT) participants (P = 0.007), but no differences existed in the AUC of nateglinide between the two genotype groups. In the drug-drug interaction study, the mean increase in the repaglinide AUC by gemfibrozil was ~50% (P = 0.002) larger in c.521CC participants than in c.521TT participants, but the relative (7-8-fold) increases in the repaglinide AUC did not differ significantly between the genotype groups. In c.521TT participants, atorvastatin increased repaglinide peak plasma concentration and AUC by ~40% (P = 0.001) and ~20% (P = 0.033), respectively. In each study, after repaglinide administration, there was a tendency towards lower blood glucose concentrations in c.521CC participants than in c.521TT participants. In conclusion, the SLCO1B1 c.521CC genotype is associated with increased and the SLCO1B1*1B/*1B genotype with decreased plasma concentrations of repaglinide, consistent with reduced and enhanced hepatic uptake, respectively. Inhibition of OATP1B1 plays a limited role in the interaction between gemfibrozil and repaglinide. Atorvastatin slightly raises plasma repaglinide concentrations, probably by inhibiting OATP1B1. The findings on the effect of SLCO1B1 polymorphism on the pharmacokinetics of the drugs studied suggest that in vivo in humans OATP1B1 significantly contributes to the hepatic uptake of repaglinide, but not to that of nateglinide, rosiglitazone, or pioglitazone. SLCO1B1 polymorphism may be associated with clinically significant differences in blood glucose-lowering response to repaglinide, but probably has no effect on the response to nateglinide, rosiglitazone, or pioglitazone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enhanced Scan design can significantly improve the fault coverage for two pattern delay tests at the cost of exorbitantly high area overhead. The redundant flip-flops introduced in the scan chains have traditionally only been used to launch the two-pattern delay test inputs, not to capture tests results. This paper presents a new, much lower cost partial Enhanced Scan methodology with both improved controllability and observability. Facilitating observation of some hard to observe internal nodes by capturing their response in the already available and underutilized redundant flip-flops improves delay fault coverage with minimal or almost negligible cost. Experimental results on ISCAS'89 benchmark circuits show significant improvement in TDF fault coverage for this new partial enhance scan methodology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method of testing for parametric faults of analog circuits based on a polynomial representation of fault-free function of the circuit is presented. The response of the circuit under test (CUT) is estimated as a polynomial in the applied input voltage at relevant frequencies in addition to DC. Classification or Cur is based on a comparison of the estimated polynomial coefficients with those of the fault free circuit. This testing method requires no design for test hardware as might be added to the circuit fly some other methods. The proposed method is illustrated for a benchmark elliptic filter. It is shown to uncover several parametric faults causing deviations as small as 5% from the nominal values.