985 resultados para Courbe dose-réponse non linéaire
Resumo:
BACKGROUND Non-steroidal anti-inflammatory drugs (NSAIDs) are the backbone of osteoarthritis pain management. We aimed to assess the effectiveness of different preparations and doses of NSAIDs on osteoarthritis pain in a network meta-analysis. METHODS For this network meta-analysis, we considered randomised trials comparing any of the following interventions: NSAIDs, paracetamol, or placebo, for the treatment of osteoarthritis pain. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) and the reference lists of relevant articles for trials published between Jan 1, 1980, and Feb 24, 2015, with at least 100 patients per group. The prespecified primary and secondary outcomes were pain and physical function, and were extracted in duplicate for up to seven timepoints after the start of treatment. We used an extension of multivariable Bayesian random effects models for mixed multiple treatment comparisons with a random effect at the level of trials. For the primary analysis, a random walk of first order was used to account for multiple follow-up outcome data within a trial. Preparations that used different total daily dose were considered separately in the analysis. To assess a potential dose-response relation, we used preparation-specific covariates assuming linearity on log relative dose. FINDINGS We identified 8973 manuscripts from our search, of which 74 randomised trials with a total of 58 556 patients were included in this analysis. 23 nodes concerning seven different NSAIDs or paracetamol with specific daily dose of administration or placebo were considered. All preparations, irrespective of dose, improved point estimates of pain symptoms when compared with placebo. For six interventions (diclofenac 150 mg/day, etoricoxib 30 mg/day, 60 mg/day, and 90 mg/day, and rofecoxib 25 mg/day and 50 mg/day), the probability that the difference to placebo is at or below a prespecified minimum clinically important effect for pain reduction (effect size [ES] -0·37) was at least 95%. Among maximally approved daily doses, diclofenac 150 mg/day (ES -0·57, 95% credibility interval [CrI] -0·69 to -0·46) and etoricoxib 60 mg/day (ES -0·58, -0·73 to -0·43) had the highest probability to be the best intervention, both with 100% probability to reach the minimum clinically important difference. Treatment effects increased as drug dose increased, but corresponding tests for a linear dose effect were significant only for celecoxib (p=0·030), diclofenac (p=0·031), and naproxen (p=0·026). We found no evidence that treatment effects varied over the duration of treatment. Model fit was good, and between-trial heterogeneity and inconsistency were low in all analyses. All trials were deemed to have a low risk of bias for blinding of patients. Effect estimates did not change in sensitivity analyses with two additional statistical models and accounting for methodological quality criteria in meta-regression analysis. INTERPRETATION On the basis of the available data, we see no role for single-agent paracetamol for the treatment of patients with osteoarthritis irrespective of dose. We provide sound evidence that diclofenac 150 mg/day is the most effective NSAID available at present, in terms of improving both pain and function. Nevertheless, in view of the safety profile of these drugs, physicians need to consider our results together with all known safety information when selecting the preparation and dose for individual patients. FUNDING Swiss National Science Foundation (grant number 405340-104762) and Arco Foundation, Switzerland.
Resumo:
Bone marrow ablation, i.e., the complete sterilization of the active bone marrow, followed by bone marrow transplantation (BMT) is a comment treatment of hematological malignancies. The use of targeted bone-seeking radiopharmaceuticals to selectively deliver radiation to the adjacent bone marrow cavities while sparing normal tissues is a promising technique. Current radiopharmaceutical treatment planning methods do not properly compensate for the patient-specific variable distribution of radioactive material within the skeleton. To improve the current method of internal dosimetry, novel methods for measuring the radiopharmaceutical distribution within the skeleton were developed. 99mTc-MDP was proven as an adequate surrogate for measuring 166Ho-DOTMP skeletal uptake and biodistribution, allowing these measures to be obtained faster, safer, and with higher spatial resolution. This translates directly into better measurements of the radiation dose distribution within the bone marrow. The resulting bone marrow dose-volume histograms allow prediction of the patient disease response where conventional organ scale dosimetry failed. They indicate that complete remission is only achieved when greater than 90% of the bone marrow receives at least 30 Gy. ^ Comprehensive treatment planning requires combining target and non-target organ dosimetry. Organs in the urinary tract were of special concern. The kidney dose is primarily dependent upon the mean transit time of 166 Ho-DOTMP through the kidney. Deconvolution analysis of renograms predicted a mean transit time of 2.6 minutes for 166Ho-DOTMP. The radiation dose to the urinary bladder wall is dependent upon numerous factors including patient hydration and void schedule. For beta-emitting isotopes such as 166Ho, reduction of the bladder wall dose is best accomplished through good patient hydration and ensuring a partially full bladder at the time of injection. Encouraging the patient to void frequently, or catheterizing the patient without irrigation, will not significantly reduce the bladder wall dose. ^ The results from this work will produce the most advanced treatment planning methodology for bone marrow ablation therapy using radioisotopes currently available. Treatments can be tailored specifically for each patient, including the addition of concomitant total body irradiation for patients with unfavorable dose distributions, to deliver a desired patient disease response, while minimizing the dose or toxicity to non-target organs. ^
Resumo:
Lung cancer is the leading cause of cancer death. However, poor survival using conventional therapies fuel the search for more rational interventions. The objective of this study was to design and implement a 4HPR-radiation interaction model in NSCLC, employing a traditional clinical modality (radiation), a relatively new, therapeutically unexplored agent (4HPR) and rationally combining them based on molecular mechanistic findings pertaining to their interactions. To test the hypothesis that 4HPR sensitizes cells to radiation-induced cell death via G2+M accumulation, we designed a working model consisting of H522 adenocarcinoma cells (p53, K-ras mutated) derived from an NSCLC patient; 4HPR at concentrations up to 10 μM; and X radiation up to 6 Gy generated by a patient-dedicated Phillips RT-250 X ray unit at 250 KV, 15 mA, 1.85 Gy/min. We found that 4HPR produced time- and dose-dependent morphological changes, growth inhibition, and DNA damage-inducing enhancement of reactive oxygen species. A transient G2+M accumulation of cells maximal at 24 h of continuous 4HPR exposure was used for irradiation time scheduling. Our data demonstrated enhanced cell death (both apoptotic and necrotic) in irradiated cells pre-treated with 4HPR versus those with either stressor alone. 4HPR's effect of increased NSCLC cells' radioresponse was confirmed by clonogenic assay. To explore these practical findings from a molecular mechanistic perspective, we further investigated and showed that levels of cyclin B1 and p34cdc2 kinase—both components of the mitosis promoting factor (MPF) regulating the G2/M transition—did not change following 4HPR treatment. Likewise, cdc25C phosphatase was not altered. However, enhanced p34cdc2 phosphorylation on its Thr14Tyr15 residues—indicative of its inactivation and increased expression of MPF negative regulators chk1 and wee1 kinases—were supportive of explaining 4HPR-treated cells' accumulation. Hence, p34cdc2 phosphorylation, chk1, and wee1 warrant further evaluation as potential molecular targets for 4HPR-X radiation combination. In summary, we (1) demonstrated that 4HPR not only induces cell death by itself, but also increases NSCLC cells' subsequent radioresponse, indicative of potential clinical applicability, and (2) for the first time, shed light on deciphering 4HPR-X radiation molecular mechanisms of interaction, including the finding of 4HPR's role as a p34cdc2 inactivator via Thr14Tyr15 phosphorylation. ^
Resumo:
Background. The rise in survival rates along with more detailed follow-up using sophisticated imaging studies among non-small lung cancer (NSCLC) patients has led to an increased risk of second primary tumors (SPT) among these cases. Population and hospital based studies of lung cancer patients treated between 1974 and 1996 have found an increasing risk over time for the development of all cancers following treatment of non-small cell lung cancer (NSCLC). During this time the primary modalities for treatment were surgery alone, radiation alone, surgery and post-operative radiation therapy, or combinations of chemotherapy and radiation (sequentially or concurrently). There is limited information in the literature about the impact of treatment modalities on the development of second primary tumors in these patients. ^ Purpose. To investigate the impact of treatment modalities on the risk of second primary tumors in patients receiving treatment with curative intent for non-metastatic (Stage I–III) non-small cell lung cancer (NSCLC). ^ Methods. The hospital records of 1,095 NSCLC patients who were diagnosed between 1980–2001 and received treatment with curative intent at M.D. Anderson Cancer Center with surgery alone, radiation alone (with a minimum total radiation dose of at least 45Gy), surgery and post-operative radiation therapy, radiation therapy in combination with chemotherapy or surgery in combination with chemotherapy and radiation were retrospectively reviewed. A second primary malignancy was be defined as any tumor histologically different from the initial cancer, or of another anatomic location, or a tumor of the same location and histology as the initial tumor having an interval between cancers of at least five years. Only primary tumors occurring after treatment for NSCLC will qualified as second primary tumors for this study. ^ Results. The incidence of second primary tumor was 3.3%/year and the rate increased over time following treatment. The type of NSCLC treatment was not found to have a striking effect upon SPT development. Increased rates were observed in the radiation only and chemotherapy plus radiation treatment groups; but, these increases did not exceed expected random variation. Higher radiation treatment dose, patient age and weight loss prior to index NSCLC treatment were associated with higher SPT development. ^
Resumo:
Measurement of the absorbed dose from ionizing radiation in medical applications is an essential component to providing safe and reproducible patient care. There are a wide variety of tools available for measuring radiation dose; this work focuses on the characterization of two common, solid-state dosimeters in medical applications: thermoluminescent dosimeters (TLD) and optically stimulated luminescent dosimeters (OSLD). There were two main objectives to this work. The first objective was to evaluate the energy dependence of TLD and OSLD for non-reference measurement conditions in a radiotherapy environment. The second objective was to fully characterize the OSLD nanoDot in a CT environment, and to provide validated calibration procedures for CT dose measurement using OSLD. Current protocols for dose measurement using TLD and OSLD generally assume a constant photon energy spectrum within a nominal beam energy regardless of measurement location, tissue composition, or changes in beam parameters. Variations in the energy spectrum of therapeutic photon beams may impact the response of TLD and OSLD and could thereby result in an incorrect measure of dose unless these differences are accounted for. In this work, we used a Monte Carlo based model to simulate variations in the photon energy spectra of a Varian 6MV beam; then evaluated the impact of the perturbations in energy spectra on the response of both TLD and OSLD using Burlin Cavity Theory. Energy response correction factors were determined for a range of conditions and compared to measured correction factors with good agreement. When using OSLD for dose measurement in a diagnostic imaging environment, photon energy spectra are often referenced to a therapy-energy or orthovoltage photon beam – commonly 250kVp, Co-60, or even 6MV, where the spectra are substantially different. Appropriate calibration techniques specifically for the OSLD nanoDot in a CT environment have not been presented in the literature; furthermore the dependence of the energy response of the calibration energy has not been emphasized. The results of this work include detailed calibration procedures for CT dosimetry using OSLD, and a full characterization of this dosimetry system in a low-dose, low-energy setting.
Resumo:
Background: The physical characteristic of protons is that they deliver most of their radiation dose to the target volume and deliver no dose to the normal tissue distal to the tumor. Previously, numerous studies have shown unique advantages of proton therapy over intensity-modulated radiation therapy (IMRT) in conforming dose to the tumor and sparing dose to the surrounding normal tissues and the critical structures in many clinical sites. However, proton therapy is known to be more sensitive to treatment uncertainties such as inter- and intra-fractional variations in patient anatomy. To date, no study has clearly demonstrated the effectiveness of proton therapy compared with the conventional IMRT under the consideration of both respiratory motion and tumor shrinkage in non-small cell lung cancer (NSCLC) patients. Purpose: This thesis investigated two questions for establishing a clinically relevant comparison of the two different modalities (IMRT and proton therapy). The first question was whether or not there are any differences in tumor shrinkage between patients randomized to IMRT versus passively scattered proton therapy (PSPT). Tumor shrinkage is considered a standard measure of radiation therapy response that has been widely used to gauge a short-term progression of radiation therapy. The second question was whether or not there are any differences between the planned dose and 5D dose under the influence of inter- and intra-fractional variations in the patient anatomy for both modalities. Methods: A total of 45 patients (25 IMRT patients and 20 PSPT patients) were used to quantify the tumor shrinkage in terms of the change of the primary gross tumor volume (GTVp). All patients were randomized to receive either IMRT or PSPT for NSCLC. Treatment planning goals were identical for both groups. All patients received 5 to 8 weekly repeated 4-dimensional computed tomography (4DCT) scans during the course of radiation treatments. The original GTVp contours were propagated to T50 of weekly 4DCT images using deformable image registration and their absolute volumes were measured. Statistical analysis was performed to compare the distribution of tumor shrinkage between the two population groups. In order to investigate the difference between the planned dose and the 5D dose with consideration of both breathing motion and anatomical change, we re-calculated new dose distributions at every phase of the breathing cycle for all available weekly 4DCT data sets which resulted 50 to 80 individual dose calculations for each of the 7 patients presented in this thesis. The newly calculated dose distributions were then deformed and accumulated to T50 of the planning 4DCT for comparison with the planned dose distribution. Results: At the end of the treatment, both IMRT and PSPT groups showed mean tumor volume reductions of 23.6% ( 19.2%) and 20.9% ( 17.0 %) respectively. Moreover, the mean difference in tumor shrinkage between two groups is 3% along with the corresponding 95% confidence interval, [-8%, 14%]. The rate of tumor shrinkage was highly correlated with the initial tumor volume size. For the planning dose and 5D dose comparison study, all 7 patients showed a mean difference of 1 % in terms of target coverage for both IMRT and PSPT treatment plans. Conclusions: The results of the tumor shrinkage investigation showed no statistically significant difference in tumor shrinkage between the IMRT and PSPT patients, and the tumor shrinkage between the two modalities is similar based on the 95% confidence interval. From the pilot study of comparing the planned dose with the 5D dose, we found the difference to be only 1%. Overall impression of the two modalities in terms of treatment response as measured by the tumor shrinkage and 5D dose under the influence of anatomical change that were designed under the same protocol (i.e. randomized trial) showed similar result.
Resumo:
Background: For most cytotoxic and biologic anti-cancer agents, the response rate of the drug is commonly assumed to be non-decreasing with an increasing dose. However, an increasing dose does not always result in an appreciable increase in the response rate. This may especially be true at high doses for a biologic agent. Therefore, in a phase II trial the investigators may be interested in testing the anti-tumor activity of a drug at more than one (often two) doses, instead of only at the maximum tolerated dose (MTD). This way, when the lower dose appears equally effective, this dose can be recommended for further confirmatory testing in a phase III trial under potential long-term toxicity and cost considerations. A common approach to designing such a phase II trial has been to use an independent (e.g., Simon's two-stage) design at each dose ignoring the prior knowledge about the ordering of the response probabilities at the different doses. However, failure to account for this ordering constraint in estimating the response probabilities may result in an inefficient design. In this dissertation, we developed extensions of Simon's optimal and minimax two-stage designs, including both frequentist and Bayesian methods, for two doses that assume ordered response rates between doses. ^ Methods: Optimal and minimax two-stage designs are proposed for phase II clinical trials in settings where the true response rates at two dose levels are ordered. We borrow strength between doses using isotonic regression and control the joint and/or marginal error probabilities. Bayesian two-stage designs are also proposed under a stochastic ordering constraint. ^ Results: Compared to Simon's designs, when controlling the power and type I error at the same levels, the proposed frequentist and Bayesian designs reduce the maximum and expected sample sizes. Most of the proposed designs also increase the probability of early termination when the true response rates are poor. ^ Conclusion: Proposed frequentist and Bayesian designs are superior to Simon's designs in terms of operating characteristics (expected sample size and probability of early termination, when the response rates are poor) Thus, the proposed designs lead to more cost-efficient and ethical trials, and may consequently improve and expedite the drug discovery process. The proposed designs may be extended to designs of multiple group trials and drug combination trials.^
Resumo:
Conservative procedures in low-dose risk assessment are used to set safety standards for known or suspected carcinogens. However, the assumptions upon which the methods are based and the effects of these methods are not well understood.^ To minimize the number of false-negatives and to reduce the cost of bioassays, animals are given very high doses of potential carcinogens. Results must then be extrapolated to much smaller doses to set safety standards for risks such as one per million. There are a number of competing methods that add a conservative safety factor into these calculations.^ A method of quantifying the conservatism of these methods was described and tested on eight procedures used in setting low-dose safety standards. The results using these procedures were compared by computer simulation and by the use of data from a large scale animal study.^ The method consisted of determining a "true safe dose" (tsd) according to an assumed underlying model. If one assumed that Y = the probability of cancer = P(d), a known mathematical function of the dose, then by setting Y to some predetermined acceptable risk, one can solve for d, the model's "true safe dose".^ Simulations were generated, assuming a binomial distribution, for an artificial bioassay. The eight procedures were then used to determine a "virtual safe dose" (vsd) that estimates the tsd, assuming a risk of one per million. A ratio R = ((tsd-vsd)/vsd) was calculated for each "experiment" (simulation). The mean R of 500 simulations and the probability R $<$ 0 was used to measure the over and under conservatism of each procedure.^ The eight procedures included Weil's method, Hoel's method, the Mantel-Byran method, the improved Mantel-Byran, Gross's method, fitting a one-hit model, Crump's procedure, and applying Rai and Van Ryzin's method to a Weibull model.^ None of the procedures performed uniformly well for all types of dose-response curves. When the data were linear, the one-hit model, Hoel's method, or the Gross-Mantel method worked reasonably well. However, when the data were non-linear, these same methods were overly conservative. Crump's procedure and the Weibull model performed better in these situations. ^
Resumo:
La planificación pre-operatoria se ha convertido en una tarea esencial en cirugías y terapias de marcada complejidad, especialmente aquellas relacionadas con órgano blando. Un ejemplo donde la planificación preoperatoria tiene gran interés es la cirugía hepática. Dicha planificación comprende la detección e identificación precisa de las lesiones individuales y vasos así como la correcta segmentación y estimación volumétrica del hígado funcional. Este proceso es muy importante porque determina tanto si el paciente es un candidato adecuado para terapia quirúrgica como la definición del abordaje a seguir en el procedimiento. La radioterapia de órgano blando es un segundo ejemplo donde la planificación se requiere tanto para la radioterapia externa convencional como para la radioterapia intraoperatoria. La planificación comprende la segmentación de tumor y órganos vulnerables y la estimación de la dosimetría. La segmentación de hígado funcional y la estimación volumétrica para planificación de la cirugía se estiman habitualmente a partir de imágenes de tomografía computarizada (TC). De igual modo, en la planificación de radioterapia, los objetivos de la radiación se delinean normalmente sobre TC. Sin embargo, los avances en las tecnologías de imagen de resonancia magnética (RM) están ofreciendo progresivamente ventajas adicionales. Por ejemplo, se ha visto que el ratio de detección de metástasis hepáticas es significativamente superior en RM con contraste Gd–EOB–DTPA que en TC. Por tanto, recientes estudios han destacado la importancia de combinar la información de TC y RM para conseguir el mayor nivel posible de precisión en radioterapia y para facilitar una descripción precisa de las lesiones del hígado. Con el objetivo de mejorar la planificación preoperatoria en ambos escenarios se precisa claramente de un algoritmo de registro no rígido de imagen. Sin embargo, la gran mayoría de sistemas comerciales solo proporcionan métodos de registro rígido. Las medidas de intensidad de voxel han demostrado ser criterios de similitud de imágenes robustos, y, entre ellas, la Información Mutua (IM) es siempre la primera elegida en registros multimodales. Sin embargo, uno de los principales problemas de la IM es la ausencia de información espacial y la asunción de que las relaciones estadísticas entre las imágenes son homogéneas a lo largo de su domino completo. La hipótesis de esta tesis es que la incorporación de información espacial de órganos al proceso de registro puede mejorar la robustez y calidad del mismo, beneficiándose de la disponibilidad de las segmentaciones clínicas. En este trabajo, se propone y valida un esquema de registro multimodal no rígido 3D usando una nueva métrica llamada Información Mutua Centrada en el Órgano (Organ-Focused Mutual Information metric (OF-MI)) y se compara con la formulación clásica de la Información Mutua. Esto permite mejorar los resultados del registro en áreas problemáticas incorporando información regional al criterio de similitud, beneficiándose de la disponibilidad real de segmentaciones en protocolos estándares clínicos, y permitiendo que la dependencia estadística entre las dos modalidades de imagen difiera entre órganos o regiones. El método propuesto se ha aplicado al registro de TC y RM con contraste Gd–EOB–DTPA así como al registro de imágenes de TC y MR para planificación de radioterapia intraoperatoria rectal. Adicionalmente, se ha desarrollado un algoritmo de apoyo de segmentación 3D basado en Level-Sets para la incorporación de la información de órgano en el registro. El algoritmo de segmentación se ha diseñado específicamente para la estimación volumétrica de hígado sano funcional y ha demostrado un buen funcionamiento en un conjunto de imágenes de TC abdominales. Los resultados muestran una mejora estadísticamente significativa de OF-MI comparada con la Información Mutua clásica en las medidas de calidad de los registros; tanto con datos simulados (p<0.001) como con datos reales en registro hepático de TC y RM con contraste Gd– EOB–DTPA y en registro para planificación de radioterapia rectal usando OF-MI multi-órgano (p<0.05). Adicionalmente, OF-MI presenta resultados más estables con menor dispersión que la Información Mutua y un comportamiento más robusto con respecto a cambios en la relación señal-ruido y a la variación de parámetros. La métrica OF-MI propuesta en esta tesis presenta siempre igual o mayor precisión que la clásica Información Mutua y consecuentemente puede ser una muy buena alternativa en aplicaciones donde la robustez del método y la facilidad en la elección de parámetros sean particularmente importantes. Abstract Pre-operative planning has become an essential task in complex surgeries and therapies, especially for those affecting soft tissue. One example where soft tissue preoperative planning is of high interest is liver surgery. It involves the accurate detection and identification of individual liver lesions and vessels as well as the proper functional liver segmentation and volume estimation. This process is very important because it determines whether the patient is a suitable candidate for surgical therapy and the type of procedure. Soft tissue radiation therapy is a second example where planning is required for both conventional external and intraoperative radiotherapy. It involves the segmentation of the tumor target and vulnerable organs and the estimation of the planned dose. Functional liver segmentations and volume estimations for surgery planning are commonly estimated from computed tomography (CT) images. Similarly, in radiation therapy planning, targets to be irradiated and healthy and vulnerable tissues to be protected from irradiation are commonly delineated on CT scans. However, developments in magnetic resonance imaging (MRI) technology are progressively offering advantages. For instance, the hepatic metastasis detection rate has been found to be significantly higher in Gd–EOB–DTPAenhanced MRI than in CT. Therefore, recent studies highlight the importance of combining the information from CT and MRI to achieve the highest level of accuracy in radiotherapy and to facilitate accurate liver lesion description. In order to improve those two soft tissue pre operative planning scenarios, an accurate nonrigid image registration algorithm is clearly required. However, the vast majority of commercial systems only provide rigid registration. Voxel intensity measures have been shown to be robust measures of image similarity, and among them, Mutual Information (MI) is always the first candidate in multimodal registrations. However, one of the main drawbacks of Mutual Information is the absence of spatial information and the assumption that statistical relationships between images are the same over the whole domain of the image. The hypothesis of the present thesis is that incorporating spatial organ information into the registration process may improve the registration robustness and quality, taking advantage of the clinical segmentations availability. In this work, a multimodal nonrigid 3D registration framework using a new Organ- Focused Mutual Information metric (OF-MI) is proposed, validated and compared to the classical formulation of the Mutual Information (MI). It allows improving registration results in problematic areas by adding regional information into the similitude criterion taking advantage of actual segmentations availability in standard clinical protocols and allowing the statistical dependence between the two modalities differ among organs or regions. The proposed method is applied to CT and T1 weighted delayed Gd–EOB–DTPA-enhanced MRI registration as well as to register CT and MRI images in rectal intraoperative radiotherapy planning. Additionally, a 3D support segmentation algorithm based on Level-Sets has been developed for the incorporation of the organ information into the registration. The segmentation algorithm has been specifically designed for the healthy and functional liver volume estimation demonstrating good performance in a set of abdominal CT studies. Results show a statistical significant improvement of registration quality measures with OF-MI compared to MI with both simulated data (p<0.001) and real data in liver applications registering CT and Gd–EOB–DTPA-enhanced MRI and in registration for rectal radiotherapy planning using multi-organ OF-MI (p<0.05). Additionally, OF-MI presents more stable results with smaller dispersion than MI and a more robust behavior with respect to SNR changes and parameters variation. The proposed OF-MI always presents equal or better accuracy than the classical MI and consequently can be a very convenient alternative within applications where the robustness of the method and the facility to choose the parameters are particularly important.
Resumo:
Objective To evaluate the safety of a non-chlorofluorocarbon metered dose salbutamol inhaler.
Resumo:
Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014
Resumo:
Les néoplasies pulmonaires demeurent la première cause de décès par cancer au Québec représentant près de 6000 décès par année. Au cours des dernières années, la radiothérapie stéréotaxique d’ablation (SABR) s’est imposée comme un traitement alternatif à la résection anatomique pour les patients inopérables atteints d’un cancer pulmonaire non à petites cellules de stade précoce. Il s’agit d’une modalité de traitement qui permet d’administrer des doses élevées, typiquement 30-60 Gy en 1-8 fractions, dans le but de cibler précisément le volume de traitement tout en épargnant les tissus sains. Le Centre Hospitalier de l’Université de Montréal s’est muni en 2009 d’un appareil de SABR de fine pointe, le CyberKnife™ (CK), un accélérateur linéaire produisant un faisceau de photons de 6 MV dirigé par un bras robotisé, permettant d’administrer des traitements non-coplanaires avec une précision infra-millimétrique. Ce mémoire est dédié à la caractérisation de certains enjeux cliniques et physiques associés au traitement par CK. Il s’articule autour de deux articles scientifiques revus par les pairs. D’une part, une étude prospective clinique présentant les avantages de la SABR pulmonaire, une technique qui offre un excellent contrôle tumoral à long terme et aide au maintien de la qualité de vie et de la fonction pulmonaire. D’autre part, une étude de physique médicale illustrant les limites de l’acquisition d’images tomodensitométriques en auto-rétention respiratoire lors de la planification de traitement par CK.
Resumo:
Cette recherche porte sur les pratiques d’intervention des agents de réponse en intervention de crise (RIC), de leur partenaire fixe et des agents en attente de la formation du Service de police de la Ville de Montréal (SPVM) auprès des personnes en crise ou atteintes de troubles mentaux. Les agents RIC sont des patrouilleurs de première ligne qui ont reçu une formation complète sur les principes d’intervention en contexte de crise ou de santé mentale. Ce modèle de réponse spécialisée est une solution proactive qui a pour but d’améliorer l’action policière en situation de crise et de veiller à une meilleure prise en charge de ces personnes par les ressources institutionnelles. La désinstitutionnalisation des soins et des services psychiatriques a eu pour effet une augmentation du nombre de personnes atteintes de troubles mentaux dans la communauté. Par conséquent, cet accroissement a engendré des rapports plus fréquents entre les services policiers et cette clientèle. Les interventions en contexte de crise ou de santé mentale sont particulières et complexes, de même qu’elles requièrent un niveau supérieur de compréhension des crises humaines. Les autorités policières ont admis que ces interventions représentent une part significative de leur travail et que la formation policière traditionnelle ne les prépare pas suffisamment pour intervenir adéquatement auprès de cette population. En réponse à ces considérations et dans l’objectif d’améliorer leur capacité d’agir, les forces policières se sont dotées de modèles de réponse policière spécialisée en intervention de crise. L’approche la plus répandue est l’équipe d’intervention de crise (« crisis intervention team » ou « CIT »), aussi appelée le modèle de Memphis. Il existe plusieurs variantes de ce modèle, mais les composantes principales, c’est-à-dire la formation avancée et la consolidation d’un partenariat avec le système de santé demeurent dans l’ensemble de ces structures. L’objectif de cette recherche consiste à sonder les perceptions des agents RIC, de leur partenaire fixe et des agents en attente de la formation afin de comprendre et de contraster leurs visions et leurs pratiques d’intervention en contexte de crise ou de santé mentale. Chaque groupe a apporté des précisions intéressantes. Nous avons conduit 12 entrevues qualitatives avec des policiers du SPVM. De façon générale, les participants rapportent que leurs pratiques d’intervention auprès des personnes en crise ou atteintes de troubles mentaux sont davantage ancrées dans une perspective de relation d’aide. Ils mentionnent également que la communication, l’écoute et la confiance doivent être privilégiées avant tout autre stratégie dans les situations qui les permettent et que la force doit être employée seulement lorsqu’elle est nécessaire, c’est-à-dire lorsque leur sécurité ou celle d’autrui est en péril ou lorsque la communication n’est pas possible. Puis, ils admettent que le recours à l’expertise des intervenants en santé mentale permet une analyse plus approfondie de la situation et de l’état mental de la personne visée par l’intervention. D’autre part, en ce qui concerne les limites de la formation policière traditionnelle, les candidats ont soulevé qu’il y a un manque de connaissances en matière de santé mentale ainsi qu’une difficulté associée à l’évaluation de l’état de la personne et du besoin de transport ont été soulevés. Sur le plan des apprentissages, les agents RIC disent avoir une compréhension plus globale de la problématique de santé mentale, de meilleures habiletés communicationnelles, une analyse plus approfondie de la situation, de plus grandes connaissances juridiques, une compréhension du fonctionnement des services hospitaliers ainsi qu’une appréciation particulière pour le partage de savoirs et les principes d’endiguement. Ils font part également de l’importance des rapports pour documenter l’évolution de l’état mental d’une personne et ils ajoutent que la dimension temporelle joue un rôle clé dans la résolution définitive de la problématique. Au sujet des partenaires, ils évoquent des retombées similaires. Toutefois, à la suite de la formation, ils reconnaissent davantage l’importance de leur rôle dans la sécurité de leur partenaire et ils y accordent dorénavant une attention marquée lors de ces interventions. Enfin, les agents non formés formulent des attentes relatives au développement d’outils et de compétences, ce qui leur sera rendu dans la formation RIC. Globalement, les agents RIC et les partenaires interviewés ont modifié leurs pratiques pour les arrimer avec la philosophie des interventions en contexte de crise ou de santé mentale. Ils ont également davantage confiance en leurs capacités et habiletés d’intervention auprès des personnes en crise ou atteintes de troubles mentaux grâce aux connaissances acquises dans la formation.
Genomic amplification of the caprine EDNRA locus might lead to a dose dependent loss of pigmentation
Resumo:
The South African Boer goat displays a characteristic white spotting phenotype, in which the pigment is limited to the head. Exploiting the existing phenotype variation within the breed, we mapped the locus causing this white spotting phenotype to chromosome 17 by genome wide association. Subsequent whole genome sequencing identified a 1 Mb copy number variant (CNV) harboring 5 genes including EDNRA. The analysis of 358 Boer goats revealed 3 alleles with one, two, and three copies of this CNV. The copy number is correlated with the degree of white spotting in goats. We propose a hypothesis that ectopic overexpression of a mutant EDNRA scavenges EDN3 required for EDNRB signaling and normal melanocyte development and thus likely lead to an absence of melanocytes in the non-pigmented body areas of Boer goats. Our findings demonstrate the value of domestic animals as reservoir of unique mutants and for identifying a precisely defined functional CNV.
Resumo:
Cette recherche porte sur les pratiques d’intervention des agents de réponse en intervention de crise (RIC), de leur partenaire fixe et des agents en attente de la formation du Service de police de la Ville de Montréal (SPVM) auprès des personnes en crise ou atteintes de troubles mentaux. Les agents RIC sont des patrouilleurs de première ligne qui ont reçu une formation complète sur les principes d’intervention en contexte de crise ou de santé mentale. Ce modèle de réponse spécialisée est une solution proactive qui a pour but d’améliorer l’action policière en situation de crise et de veiller à une meilleure prise en charge de ces personnes par les ressources institutionnelles. La désinstitutionnalisation des soins et des services psychiatriques a eu pour effet une augmentation du nombre de personnes atteintes de troubles mentaux dans la communauté. Par conséquent, cet accroissement a engendré des rapports plus fréquents entre les services policiers et cette clientèle. Les interventions en contexte de crise ou de santé mentale sont particulières et complexes, de même qu’elles requièrent un niveau supérieur de compréhension des crises humaines. Les autorités policières ont admis que ces interventions représentent une part significative de leur travail et que la formation policière traditionnelle ne les prépare pas suffisamment pour intervenir adéquatement auprès de cette population. En réponse à ces considérations et dans l’objectif d’améliorer leur capacité d’agir, les forces policières se sont dotées de modèles de réponse policière spécialisée en intervention de crise. L’approche la plus répandue est l’équipe d’intervention de crise (« crisis intervention team » ou « CIT »), aussi appelée le modèle de Memphis. Il existe plusieurs variantes de ce modèle, mais les composantes principales, c’est-à-dire la formation avancée et la consolidation d’un partenariat avec le système de santé demeurent dans l’ensemble de ces structures. L’objectif de cette recherche consiste à sonder les perceptions des agents RIC, de leur partenaire fixe et des agents en attente de la formation afin de comprendre et de contraster leurs visions et leurs pratiques d’intervention en contexte de crise ou de santé mentale. Chaque groupe a apporté des précisions intéressantes. Nous avons conduit 12 entrevues qualitatives avec des policiers du SPVM. De façon générale, les participants rapportent que leurs pratiques d’intervention auprès des personnes en crise ou atteintes de troubles mentaux sont davantage ancrées dans une perspective de relation d’aide. Ils mentionnent également que la communication, l’écoute et la confiance doivent être privilégiées avant tout autre stratégie dans les situations qui les permettent et que la force doit être employée seulement lorsqu’elle est nécessaire, c’est-à-dire lorsque leur sécurité ou celle d’autrui est en péril ou lorsque la communication n’est pas possible. Puis, ils admettent que le recours à l’expertise des intervenants en santé mentale permet une analyse plus approfondie de la situation et de l’état mental de la personne visée par l’intervention. D’autre part, en ce qui concerne les limites de la formation policière traditionnelle, les candidats ont soulevé qu’il y a un manque de connaissances en matière de santé mentale ainsi qu’une difficulté associée à l’évaluation de l’état de la personne et du besoin de transport ont été soulevés. Sur le plan des apprentissages, les agents RIC disent avoir une compréhension plus globale de la problématique de santé mentale, de meilleures habiletés communicationnelles, une analyse plus approfondie de la situation, de plus grandes connaissances juridiques, une compréhension du fonctionnement des services hospitaliers ainsi qu’une appréciation particulière pour le partage de savoirs et les principes d’endiguement. Ils font part également de l’importance des rapports pour documenter l’évolution de l’état mental d’une personne et ils ajoutent que la dimension temporelle joue un rôle clé dans la résolution définitive de la problématique. Au sujet des partenaires, ils évoquent des retombées similaires. Toutefois, à la suite de la formation, ils reconnaissent davantage l’importance de leur rôle dans la sécurité de leur partenaire et ils y accordent dorénavant une attention marquée lors de ces interventions. Enfin, les agents non formés formulent des attentes relatives au développement d’outils et de compétences, ce qui leur sera rendu dans la formation RIC. Globalement, les agents RIC et les partenaires interviewés ont modifié leurs pratiques pour les arrimer avec la philosophie des interventions en contexte de crise ou de santé mentale. Ils ont également davantage confiance en leurs capacités et habiletés d’intervention auprès des personnes en crise ou atteintes de troubles mentaux grâce aux connaissances acquises dans la formation.