969 resultados para Chest asymmetry
Resumo:
A new transceive system for chest imaging for MRI applications is presented. A focused, eight-element transceive torso phased array coil is designed to investigate transmitting a focused radiofrequency field deep within the torso and to enhance signal homogeneity in the heart region. The system is used in conjunction with the SENSE reconstruction technique to enable focused parallel imaging. A hybrid finite-difference-time-domain/method-of-moments method is used to accurately predict the radiofrequency behavior inside the human torso. The simulation results reported herein demonstrate the feasibility of the design concept, which shows that radiofrequency field focusing with SENSE reconstruction is theoretically achievable. (c) 2005 Wiley-Liss, Inc.
Resumo:
This article is predicated on the idea that leaders shape workplace affective events. Based on Affective Events Theory (AET), I argue that leaders are sources of employee positive and negative emotions at work. Certain leader behaviors displayed during interactions with their employees are the sources of these affective events. The second theoretical underpinning of the article is the Asymmetry Effect of emotion. Consistent with this theory, employees are more likely to recall negative incidents than positive incidents. In a qualitative study, evidence that these processes exist in the workplace was found. Leader behaviors were sources of positive or negative emotional responses in employees; employees recalled more negative incidents than positive incidents, and they recalled them more intensely and in more detail than positive incidents. Consequently, leaders may need to exercise their emotional intelligence to generate emotional uplifts to overcome the hassles in the workplace that employees seem to remember so vividly. (c) 2006 Elsevier Inc. All rights reserved.
Resumo:
Despite the considerable evidence showing that dispersal between habitat patches is often asymmetric, most of the metapopulation models assume symmetric dispersal. In this paper, we develop a Monte Carlo simulation model to quantify the effect of asymmetric dispersal on metapopulation persistence. Our results suggest that metapopulation extinctions are more likely when dispersal is asymmetric. Metapopulation viability in systems with symmetric dispersal mirrors results from a mean field approximation, where the system persists if the expected per patch colonization probability exceeds the expected per patch local extinction rate. For asymmetric cases, the mean field approximation underestimates the number of patches necessary for maintaining population persistence. If we use a model assuming symmetric dispersal when dispersal is actually asymmetric, the estimation of metapopulation persistence is wrong in more than 50% of the cases. Metapopulation viability depends on patch connectivity in symmetric systems, whereas in the asymmetric case the number of patches is more important. These results have important implications for managing spatially structured populations, when asymmetric dispersal may occur. Future metapopulation models should account for asymmetric dispersal, while empirical work is needed to quantify the patterns and the consequences of asymmetric dispersal in natural metapopulations.
Resumo:
We report the case study of a 68-year-old female with cardiac syndrome X presenting with abnormal pressure waveforms and a hypertensive response to exercise with ST-segment depression. After amlodipine treatment, pressure waveform morphology was significantly improved, exercise testing was normal and symptoms had resolved. This case emphasizes the potential clinical value of arterial waveform analysis.
Resumo:
Aims Technological advances in cardiac imaging have led to dramatic increases in test utilization and consumption of a growing proportion of cardiovascular healthcare costs. The opportunity costs of strategies favouring exercise echocardiography or SPECT imaging have been incompletely evaluated. Methods and results We examined prognosis and cost-effectiveness of exercise echocardiography (n=4884) vs. SPECT (n=4637) imaging in stable, intermediate risk, chest pain patients. Ischaemia extent was defined as the number of vascular territories with echocardiographic wall motion or SPECT perfusion abnormalities. Cox proportional hazard models were employed to assess time to cardiac death or myocardial infarction (MI). Total cardiovascular costs were summed (discounted and inflation-corrected) throughout follow-up. A cost-effectiveness ratio = 2% annual event risk), SPECT ischaemia was associated with earlier and greater utilization of coronary revascularization (P < 0.0001) resulting in an incremental cost-effectiveness ratio of $32 381/LYS. Conclusion Health care policies aimed at allocating limited resources can be effectively guided by applying clinical and economic outcomes evidence. A strategy aimed at cost-effective testing would support using echocardiography in low-risk patients with suspected coronary disease, whereas those higher risk patients benefit from referral to SPECT imaging.
Resumo:
Disinhibition is usually defined as a combination of high extraversion and high neuroticism or high extraversion and low neuroticism. The hypothesis that neuroticism interacts with aural preference (preferred-ear for listening) in the prediction of everyday types of disinhibited behaviour is tested. The importance of aural preference rests on the assumption that it is a readily available proxy measure of contra-hemispheric preference such that a left aural preference is indicative of right hemispheric preference and vice versa. Since the left hemisphere acts to initiate approach behaviour, the hypothesis investigates a model in which preference for the left hemisphere, together with high neuroticism, provides an alternative mechanism of disinhibition. This study provides evidence of the mechanism in the predicdon of disinhibited telesales performance.
Resumo:
Accurate interpretation of distortion product otoacoustic emission (DPOAE) data cannot be made without realizing the effects of non-pathological factors on DPOAEs. The present study aimed to examine the effects of ear asymmetry, gender and handedness on DPOAEs obtained from school children. One thousand and three children (528 boys and 475 girls) with a mean age of 6.2 years (SD = 0.4, range = 5.2 7.9 years) were tested in a quiet room at their schools using the GSI-60 DPOAE system. The stimuli consisted of two pure tones of different frequencies f1 and f2 presented at 65 and 55dB SPL respectively. A DP-gram was obtained for each ear with f2 varying from 1.1 to 6.0 kHz and the ratio of f2/f1 being kept at 1.21. The signal-to-noise ratios (SNR) (DPOAE amplitude minus the mean noise floor) at the tested frequencies 1.1, 1.5, 1.9, 2.4, 3.0, 3.8, 4.8, and 6.0 kHz were measured. The results revealed a small, but significant difference in SNR between ears, with right ears showing a higher mean SNR than left ears at 1.9, 3.0, 3.8 and 6.0 kHz. At these frequencies, the difference in mean SNR between ears was less than 1 dB. A significant gender effect was also found, with girls exhibiting a higher SNR than boys at 3.8, 4.8 and 6.0 kHz. The difference in mean SNR, as a result of the gender effect, was about 1 to 2 dB at these frequencies. The results from the present study indicated no significant difference in mean SNR between left-handed and right-handed children for all tested frequencies. In conclusion, these non-pathological characteristics of DPOAEs should be considered in the interpretation of DPOAE results for school children.
Resumo:
Phakometric measurements of corneal and crystalline lens surface alignment are influenced by corneal asymmetry in which the corneal apex does not coincide with the limbal centre. The purpose of this study was to determine the horizontal separation (e) between these corneal landmarks. Measurements were made in 60 normal eyes (30 subjects) using the Orbscan Ilz corneal analysis workstation. Our results show that both corneal landmarks typically coincide, so that e = 0, but that inter-subject variations of about ±1 mm can be expected (so that the corneal apex may fall nasal or temporal to the visual axis). This suggests that no correction for corneal asymmetry is required when estimating average amounts of ocular alignment from samples of eyes but that the measurement of e is strongly recommended for measurements in individual eyes. © 2004 The College of Optometrists.