Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
We placed spheres of synthetic hydroxyapatite (calcium chloride combined with sodium phosphate) in the eviscerated or enucleated orbital cavity of rats in order to evaluate the biocompatibility of this material with the orbital cavity. The study was conducted on 50 albino rats, 25 of which were submitted to enucleation and 25 to evisceration of one eye. The animals were sacrificed 7, 15, 21, 30 and 60 days after surgery and the orbital content was submitted to histopathological examination. A reaction of the young granulation tissue type was observed first. The hydroxyapatite was gradually surrounded by a granulomatous macrophage inflammatory response and covered with dense connective tissue that formed a sort of mesh septating and supporting progressively smaller blocks of the substance. The same type of reaction was observed in the enucleated and eviscerated cavities. We conclude that synthetic hydroxyapatite is an inert nonallergenic material which is appropriate for volume replacement in the anophthalmic cavity
Resumo:
AIM: To evaluate the host response of the gel and porous polyethylene implants in anophthalmic cavities using the B scan ultrasound.METHODS: Thirty-six white rabbits underwent unilateral enucleation with placement of gel or porous polyethylene spheres implants. The animals were submitted to clinical examination weekly and to ultrasound evaluation on 30, 60 and 90 days after surgery.RESULTS: All rabbits with gel polyethylene spheres, except one, showed implant extrusion probably because the gel spheres have hydrated and increased in volume. The B ultrasound of the gel polyethylene implant did not show vessels inside during the following period. Five animals (27.8%) with porous polyethylene spheres presented implant extrusion after 30 days of surgery. According to B ultrasound, the porous polyethylene implant showed irregular and heterogeneous architecture and reflective peaks similar to vascularized tissues.CONCLUSION: More studies are required to determine the ideal volume of gel polyethylene implant necessary to correct the diminished orbital content in the anophthalmic cavity. The B ultrasound effectiveness showed in this study for anophthalmic socket implants evaluation provides useful information for further in vivo studies and might substitute expensive methods of implants vascularization evaluation,
Resumo:
The aims of this study were to develop a dental chart evaluate any oral cavity disease, develop gypsum models the dental arches, and to register the occlusions found in coatis (Nasua nasua) in captivity. Formulation of the dental chart was assisted by intraoral radiographs from the head of an adult coati cadaver of the same species with the following dental formula: I 3/3, C 1/1, P 4/3, M 2/2. Seven live coatis of the Nasua nasua species were evaluated. Five of the seven coatis presented with various dental abnormalities as follows: dental plaque (71.4 %), gingivitis (71.4 %), periodontitis (57.1 %), dental stain (42.9 %), dental abrasion (57.1 %), dental fracture (57.1 %), pulp exposure (42.9 %), malocclusion (5 7.1 %) and supernumerary teeth (14.2 %).
Resumo:
The aim of this study was to investigate cellular migration induced by calcium hydroxide to air-pouch cavities in mice. The migration was more specific to neutrophil and was dose and time dependent (peaking 96 h after stimulation). This migration was inhibited by pretreatment with thalidomide, indomethacin, MK886, meloxicam, dexamethasone, MK886 associated with indomethacin, and MK886 associated with indomethacin and dexamethasone. The air-pouch exudate from animals stimulated with calcium hydroxide showed an increase of leukotriene-B4 (LTB4), interleukin-1 beta, tumor necrosis factor alpha (TNF-alpha), cytokine-induced neutrophil chemoattractant (KC), and macrophage inflammatory protein 2 (MIP-2) release. Pretreatment with 3% thioglycollate increased the macrophage population in the air pouch but did not change neutrophil migration. Depleting the resident mast cells through chronic pretreatment with compound 48/80 did not alter neutrophil migration in response to calcium hydroxide. It was possible to conclude that calcium hydroxide-induced neutrophil migration to the air-pouch cavity in mice is mediated by LTB4, TNF-alpha, KC, MIP-2, and prostaglandins, but it was not dependent on macrophages or mast cells.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objectives: This study compared three methods of Streptococcus mutans and Lactobacillus spp. detection in the oral cavity: saliva swab (SS)-sample of stimulated saliva collected with swab; whole saliva (WS)-sample of 2 ml of stimulated saliva; and the dental plaque method (DP)-plaque sample of all dental surfaces.Methods: Thirty children were included in this study. In the first 15 children, the SS and WS methods were carried out before the dental plaque collection, and in the following 15, the sequence was inverted to evaluate possible interference of the methods sequence. The samples were diluted and inoculated in SB20 and Rogosa agar, respectively for S. mutans and Lactobacillus spp., at 37 degrees C for 48 h.Results: the results (cfu/mL) of S. mutans were analysed by the statistical Friedman's test. The levels of Lactobacillus spp. were analysed by descriptive statistics due to the high proportion of zero counts in the culture. In the first sequence of methods, the number of S. mutans counted for the SS method was inferior to DP and WS (P < 0.05), and the results for the WS and DP methods were similar. The detection of Lactobacillus spp. was observed just by the WS (100 %) and SS (14.3 %) methods. However, in the second experimental set the number of S. mutans detected by the DP method was similar to those of the SS and WS, however, the WS method showed higher values than SS (P < 0.05). A greater number of Lactobacillus spp. was detected by the WS method (100 %), followed by SS (55.5 %) and DP (33.3 %).Conclusions: the dental plaque collection and the sample of stimulated whole saliva presented similar results in the S. mutans count. The most suitable method to detect the Lactobacillus spp. level in the oral cavity is the stimulated whole saliva method. (c) 2004 Elsevier Ltd. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: The aim of this in vitro study was to analyze the effect of glass-ionomer cement as a liner on the dentin/resin adhesive interface of lateral walls of occlusal restorations after thermocycling.Materials and Methods: Occlusal cavities were prepared in 60 human molars, divided into six groups: no liner (1 and 4); glass-ionomer cement (GIC, Ketac Molar Easymix, 3M ESPE) (2 and 5); and resin-modified glass-ionomer cement (RMGIC, Vitrebond, 3M ESPE) (3 and 6). Resin composite (Filtek Z250, 3M ESPE) was placed after application of an adhesive system (Adper Single Bond 2, 3M ESPE) that was mixed with a fluorescent reagent (Rhodamine B) to allow confocal microscopy analysis. Specimens of groups 4, 5 and 6 were thermocycled (5 degrees C-55 degrees C) with a dwell time of 30 seconds for 5000 cycles. After this period, teeth were sectioned in approximately 0.8-mm slices. One slice of each tooth was randomly selected for confocal microscopy analysis. The other slices were sectioned into 0.8 nun x 0.8 mm beams, which were submitted to microtensile testing (MPa). Data were analyzed using two-way ANOVA and Tukey test (p < 0.05).Results: There was no detectedstatistical difference on bond strength among groups (alpha < 0.05). Confocal microscopy analysis showed a higher mean gap size in group 4(12.5 mu m) and a higher percentage of marginal gaps in the thermocycled groups. The RNIGIC liner groups showed the lowest percentage of marginal gaps.Conclusions: Lining with RMGIC resulted in less gap formation at the dentin/resin adhesive interface after artificial aging. RMGIC or GIC liners did not alter the microtensile bond strength of adhesive system/resin composite to dentin on the lateral walls of Class I restorations.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)