896 resultados para CONTRAST ENHANCEMENT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

X-ray medical imaging is increasingly becoming three-dimensional (3-D). The dose to the population and its management are of special concern in computed tomography (CT). Task-based methods with model observers to assess the dose-image quality trade-off are promising tools, but they still need to be validated for real volumetric images. The purpose of the present work is to evaluate anthropomorphic model observers in 3-D detection tasks for low-contrast CT images. We scanned a low-contrast phantom containing four types of signals at three dose levels and used two reconstruction algorithms. We implemented a multislice model observer based on the channelized Hotelling observer (msCHO) with anthropomorphic channels and investigated different internal noise methods. We found a good correlation for all tested model observers. These results suggest that the msCHO can be used as a relevant task-based method to evaluate low-contrast detection for CT and optimize scan protocols to lower dose in an efficient way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Disc herniation with posterior epidural migration is a rare and often symptomatic entity. Multiple are the natural barriers that prevent this pattern of migration. Enhanced magnetic resonance imaging is the diagnostic modality of choice in these cases. The diagnostic dilemma in this case was the contraindication to the use of contrast since the patient was known to have chronic renal failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and Methods In the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 × (0.75 × P + 0.25 × A)] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results The simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the necessity of the non contrast-enhanced phase in abdominal computed tomography scans. Materials and Methods: A retrospective, cross-sectional, observational study was developed, evaluating 244 consecutive abdominal computed tomography scans both with and without contrast injection. Initially, the contrast-enhanced images were analyzed (first analysis). Subsequently, the observers had access to the non-contrast-enhanced images for a second analysis. The primary and secondary diagnoses were established as a function of the clinical indications for each study (such as tumor staging, acute abdomen, investigation for abdominal collection and hepatocellular carcinoma, among others). Finally, the changes in the diagnoses resulting from the addition of the non-contrast-enhanced phase were evaluated. Results: Only one (0.4%; p > 0.999; non-statistically significant) out of the 244 reviewed cases had the diagnosis changed after the reading of non-contrast-enhanced images. As the secondary diagnoses are considered, 35 (14%) cases presented changes after the second analysis, as follows: nephrolithiasis (10%), steatosis (3%), adrenal nodule (0.7%) and cholelithiasis (0.3%). Conclusion: For the clinical indications of tumor staging, acute abdomen, investigation of abdominal collections and hepatocellular carcinoma, the non-contrast-enhanced phase can be excluded from abdominal computed tomography studies with no significant impact on the diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complications from central venous catheterization include infectious conditions, pneumothorax, hemothorax and venous thrombosis. Pericardial effusion with cardiac tamponade hardly occurs, and in infants is generally caused by umbilical catheterization. The authors describe the case of cardiac tamponade occurred in an infant during chest computed tomography with contrast infusion through a central venous catheter inserted into the right internal jugular vein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent studies have demonstrated that the use of paramagnetic hepatobiliary contrast agents in the acquisition of magnetic resonance images remarkably improves the detection and differentiation of focal liver lesions, as compared with extracellular contrast agents. Paramagnetic hepatobiliary contrast agents initially show the perfusion of the lesions, as do extracellular agents, but delayed contrast-enhanced images can demonstrate contrast uptake by functional hepatocytes, providing further information for a better characterization of the lesions. Additionally, this intrinsic characteristic increases the accuracy in the detection of hepatocellular carcinomas and metastases, particularly the small-sized ones. Recently, a hepatobiliary contrast agent called gadolinium ethoxybenzyl dimeglumine, that is simply known as gadoxetic acid, was approved by the National Health Surveillance Agency for use in humans. The authors present a literature review and a practical approach of magnetic resonance imaging utilizing gadoxetic acid as contrast agent, based on patients' images acquired during their initial experiment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective:To investigate the effects of dilution of paramagnetic contrast agent with iodinated contrast and xylocaine on the signal intensity during magnetic resonance arthrography, and to improve the paramagnetic contrast agent concentration utilized in this imaging modality.Materials and Methods:Samples specially prepared for the study with three different concentrations of paramagnetic contrast agent diluted in saline, iodinated contrast agent and xylocaine were imaged with fast spin echo T1-weighted sequences with fat saturation. The samples were placed into flasks and graphical analysis of the signal intensity was performed as a function of the paramagnetic contrast concentration.Results:As compared with samples of equal concentrations diluted only with saline, the authors have observed an average signal intensity decrease of 20.67% for iodinated contrast agent, and of 28.34% for xylocaine. However, the increased gadolinium concentration in the samples caused decrease in signal intensity with all the dilutions.Conclusion:Minimizing the use of iodinated contrast media and xylocaine and/or the use of a gadolinium concentration of 2.5 mmol/L diluted in saline will improve the sensitivity of magnetic resonance arthrography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractObjective:In the present study, the authors investigated the in vitrobehavior of radio-resistant breast adenocarcinoma (MDA-MB-231) cells line and radiosensitive peripheral blood mononuclear cells (PBMC), as a function of different radiation doses, dose rates and postirradiation time kinetics, with a view to the interest of clinical radiotherapy.Materials and Methods:The cells were irradiated with Co-60, at 2 and 10 Gy and two different exposure rates, 339.56 cGy.min–1 and the other corresponding to one fourth of the standard dose rates, present over a 10-year period of cobalt therapy. Post-irradiation sampling was performed at pre-established kinetics of 24, 48 and 72 hours. The optical density response in viability assay was evaluated and a morphological analysis was performed.Results:Radiosensitive PBMC showed decrease in viability at 2 Gy, and a more significant decrease at 10 Gy for both dose rates. MDAMB- 231 cells presented viability decrease only at higher dose and dose rate. The results showed MDA-MB-231 clone expansion at low dose rate after 48–72 hours post-radiation.Conclusion:Low dose rate shows a possible potential clinical impact involving decrease in management of radio-resistant and radiosensitive tumor cell lines in cobalt therapy for breast cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Co-culture techniques associating both dermal fibroblasts and epidermal keratinocytes have shown to have better clinical outcome than keratinocyte culture alone for the treatment of severe burns. Since fat grafting has been shown to improve scar remodelling, new techniques such as cell-therapy-assisted surgical reconstruction with isolated and expanded autologous adipose-derived stem cells (ASCs) would be of benefit to increase graft acceptation. Therefore, integrating ASCs into standardized procedures for cultured skin grafting could be of benefit for the patient if cell quality and quantity could be maintained. The purpose of this study was to evaluate ASC processing from adult tissue with simple isolation (without enzymatic steps), expansion (low density of 325-3,000 cells/cm2) and storage conditions to assure methods to enhance the cellular resistance when transferred back to the patient. Co-culture with cell-banked skin progenitor cells (FE002-SK2) showed an increase of 40-50% ASCs yield at high passages alongside with a better preservation of morphology, proper adipogenic and osteogenic differentiation and efficient biocompatibility with 3D collagen scaffolds. ASCs can be considered as a valuable additional cell source to be delivered in biological bandages to the patient in a need of tissue reconstruction such as burn patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stora Enso has research centres in Finland, Sweden and Germany. The research centres use PIMS as a research project invoicing and monitoring system. Possible reorganization and new financing model for R&D functions have been considered and the project management system should be developed to support the new operation model. The objective of this thesis is to find a model for R&D project management, and to present the project management system of Stora Enso, and to discuss if the current system could be developed to respond to the new needs or should it be replaced with another system. The theoretical part of the study describes challenges in R&D project management, and presents different project characteristics, and methods for managing R&D project portfolio. It is also described how the project management system can support project monitoring and controlling, and how inter-project learning can be enhanced. The empirical part of the study presents the current project management system of Stora Enso and how the system should be developed to support Stora Enso’s R&D functions better. In conclusion, it is stated that there is no relevant reason to replace PIMS with another system, because PIMS can be developed to support R&D project management better with a hybrid system. It is also suggested that the new financing model should not be implemented before more comprehensive analysis of its effects is conducted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, preliminary results of the use of hydrophobic thin films obtained by plasma deposition to protect grains and seeds are presented: grains coated by the films did not present biological degradation when stored in a saturated water vapor environment, but had their germination accelerated in the presence of water. A model that explains the difference of behavior of the films when exposed to water in vapor form or in liquid form, based on the formation of microchannels within the film that lead to water uptake in seeds, is presented. The model was successfully tested using quartz crystal measurements, which showed that the microchannels within the films can favor the adsorption and permeation of water when the films are immersed in water.