910 resultados para Automated quantification


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cells of epithelial origin, e.g. from breast and prostate cancers, effectively differentiate into complex multicellular structures when cultured in three-dimensions (3D) instead of conventional two-dimensional (2D) adherent surfaces. The spectrum of different organotypic morphologies is highly dependent on the culture environment that can be either non-adherent or scaffold-based. When embedded in physiological extracellular matrices (ECMs), such as laminin-rich basement membrane extracts, normal epithelial cells differentiate into acinar spheroids reminiscent of glandular ductal structures. Transformed cancer cells, in contrast, typically fail to undergo acinar morphogenic patterns, forming poorly differentiated or invasive multicellular structures. The 3D cancer spheroids are widely accepted to better recapitulate various tumorigenic processes and drug responses. So far, however, 3D models have been employed predominantly in the Academia, whereas the pharmaceutical industry has yet to adopt a more widely and routine use. This is mainly due to poor characterisation of cell models, lack of standardised workflows and high throughput cell culture platforms, and the availability of proper readout and quantification tools. In this thesis, a complete workflow has been established entailing well-characterised 3D cell culture models for prostate cancer, a standardised 3D cell culture routine based on high-throughput-ready platform, automated image acquisition with concomitant morphometric image analysis, and data visualisation, in order to enable large-scale high-content screens. Our integrated suite of software and statistical analysis tools were optimised and validated using a comprehensive panel of prostate cancer cell lines and 3D models. The tools quantify multiple key cancer-relevant morphological features, ranging from cancer cell invasion through multicellular differentiation to growth, and detect dynamic changes both in morphology and function, such as cell death and apoptosis, in response to experimental perturbations including RNA interference and small molecule inhibitors. Our panel of cell lines included many non-transformed and most currently available classic prostate cancer cell lines, which were characterised for their morphogenetic properties in 3D laminin-rich ECM. The phenotypes and gene expression profiles were evaluated concerning their relevance for pre-clinical drug discovery, disease modelling and basic research. In addition, a spontaneous model for invasive transformation was discovered, displaying a highdegree of epithelial plasticity. This plasticity is mediated by an abundant bioactive serum lipid, lysophosphatidic acid (LPA), and its receptor LPAR1. The invasive transformation was caused by abrupt cytoskeletal rearrangement through impaired G protein alpha 12/13 and RhoA/ROCK, and mediated by upregulated adenylyl cyclase/cyclic AMP (cAMP)/protein kinase A, and Rac/ PAK pathways. The spontaneous invasion model tangibly exemplifies the biological relevance of organotypic cell culture models. Overall, this thesis work underlines the power of novel morphometric screening tools in drug discovery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Babesiosis is one of the most important diseases affecting livestock agriculture worldwide. Animals from the subspecies Bos taurus indicus are more resistant to babesiosis than those from Bos taurus taurus. The genera Babesia and Plasmodium are Apicomplexa hemoparasites and share features such as invasion of red blood cells (RBC). The glycoprotein Duffy is the only human erythrocyte receptor for Pasmodium vivax and a mutation which abolishes expression of this glycoprotein on erythrocyte surfaces is responsible for making the majority of people originating from the indigenous populations of West Africa resistant to P. vivax. The current work detected and quantified the Duffy antigen on Bos taurus indicus and Bos taurus taurus erythrocyte surfaces using a polyclonal antibody in order to investigate if differences in susceptibility to Babesia are due to different levels of Duffy antigen expression on the RBCs of these animals, as is known to be the case in human beings for interactions of Plasmodium vivax-Duffy antigen. ELISA tests showed that the antibody that was raised against Duffy antigens detected the presence of Duffy antigen in both subspecies and that the amount of this antigen on those erythrocyte membranes was similar. These results indicate that the greater resistance of B. taurus indicus to babesiosis cannot be explained by the absence or lower expression of Duffy antigen on RBC surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare two methods of tear sampling for protein quantification. Tear samples were collected from 29 healthy dogs (58 eyes) using Schirmer tear test (STT) strip and microcapillary tubes. The samples were frozen at -80ºC and analyzed by the Bradford method. Results were analyzed by Student's t test. The average protein concentration and standard deviation from tears collected with microcapillary tube were 4.45mg/mL ±0.35 and 4,52mg/mL ±0.29 for right and left eyes respectively. The average protein concentration and standard deviation from tears collected with Schirmer Tear Test (STT) strip were and 54.5mg/mL ±0.63 and 54.15mg/mL ±0.65 to right and left eyes respectively. Statistically significant differences (p<0.001) were found between the methods. In the conditions in which this study was conducted, the average protein concentration obtained with the Bradford test from tear samples obtained by Schirmer Tear Test (STT) strip showed values higher than those obtained with microcapillary tube. It is important that concentration of tear protein pattern values should be analyzed according the method used to collect tear samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The importance of efficient supply chain management has increased due to globalization and the blurring of organizational boundaries. Various supply chain management technologies have been identified to drive organizational profitability and financial performance. Organizations have historically been concentrating heavily on the flow of goods and services, while less attention has been dedicated to the flow of money. While supply chains are becoming more transparent and automated, new opportunities for financial supply chain management have emerged through information technology solutions and comprehensive financial supply chain management strategies. This research concentrates on the end part of the purchasing process which is the handling of invoices. Efficient invoice processing can have an impact on organizations working capital management and thus provide companies with better readiness to face the challenges related to cash management. Leveraging a process mining solution the aim of this research was to examine the automated invoice handling process of four different organizations. The invoice data was collected from each organizations invoice processing system. The sample included all the invoices organizations had processed during the year 2012. The main objective was to find out whether e-invoices are faster to process in an automated invoice processing solution than scanned invoices (post entry into invoice processing solution). Other objectives included looking into the longest lead times between process steps and the impact of manual process steps on cycle time. Processing of invoices from maverick purchases was also examined. Based on the results of the research and previous literature on the subject, suggestions for improving the process were proposed. The results of the research indicate that scanned invoices were processed faster than e-invoices. This is mostly due to the more complex processing of e-invoices. It should be noted however that the manual tasks related to turning a paper invoice into electronic format through scanning are ignored in this research. The transitions with the longest lead times in the invoice handling process included both pre-automated steps as well as manual steps performed by humans. When the most common manual steps were examined in more detail, it was clear that these steps had a prolonging impact on the process. Regarding invoices from maverick purchases the evidence shows that these invoices were slower to process than invoices from purchases conducted through e-procurement systems and from preferred suppliers. Suggestions on how to improve the process included: increasing invoice matching, reducing of manual steps and leveraging of different value added services such as invoice validation service, mobile solutions and supply chain financing services. For companies that have already reaped all the process efficiencies the next step is to engage in collaborative financial supply chain management strategies that can benefit the whole supply chain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bioprocess technology is a multidisciplinary industry that combines knowledge of biology and chemistry with process engineering. It is a growing industry because its applications have an important role in the food, pharmaceutical, diagnostics and chemical industries. In addition, the current pressure to decrease our dependence on fossil fuels motivates new, innovative research in the replacement of petrochemical products. Bioprocesses are processes that utilize cells and/or their components in the production of desired products. Bioprocesses are already used to produce fuels and chemicals, especially ethanol and building-block chemicals such as carboxylic acids. In order to enable more efficient, sustainable and economically feasible bioprocesses, the raw materials must be cheap and the bioprocesses must be operated at optimal conditions. It is essential to measure different parameters that provide information about the process conditions and the main critical process parameters including cell density, substrate concentrations and products. In addition to offline analysis methods, online monitoring tools are becoming increasingly important in the optimization of bioprocesses. Capillary electrophoresis (CE) is a versatile analysis technique with no limitations concerning polar solvents, analytes or samples. Its resolution and efficiency are high in optimized methods creating a great potential for rapid detection and quantification. This work demonstrates the potential and possibilities of CE as a versatile bioprocess monitoring tool. As a part of this study a commercial CE device was modified for use as an online analysis tool for automated monitoring. The work describes three offline CE analysis methods for the determination of carboxylic, phenolic and amino acids that are present in bioprocesses, and an online CE analysis method for the monitoring of carboxylic acid production during bioprocesses. The detection methods were indirect and direct UV, and laser-induced frescence. The results of this work can be used for the optimization of bioprocess conditions, for the development of more robust and tolerant microorganisms, and to study the dynamics of bioprocesses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Asteraceae weeds are rich in chemicals that have biological and pharmaceutical activities. The aims of this work were to describe the phytochemistry and quantify the polyphenols in ethanol extracts from leaves of 12 species of Asteraceae weeds collected in Diamantina, Minas Gerais State, Brazil. The screening of Asteraceae extracts revealed the presence of tannins, steroids, triterpenes, anthocyanins, and flavonoids. The total phenolic content was high in extracts of Lychnophora ericoides (147.97 ± 2.66), Lepidaploa lilacina (141.11 ± 1.99), and Eremanthus elaeagnus (134.61 ± 7.81) and low in extracts of Lychnophora ramosissima (32.65 ± 0.70), and Lychnophora sp. (54.03 ± 0.73). Extracts of Asteraceae weeds from Diamantina could have potential for biological studies that are searching for new pesticides and drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esitys KDK-käytettävyystyöryhmän järjestämässä seminaarissa: Miten käyttäjien toiveet haastavat metatietokäytäntöjämme? / How users' expectations challenge our metadata practices? 30.9.2014.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study we evaluated the precision of the ELISA method to quantify caffeine in human plasma and compared the results with those obtained by gas chromatography. A total of 58 samples were analyzed by gas chromatography using a nitrogen-phosphorus detector and routine techniques. For the ELISA test, the samples were diluted to obtain a concentration corresponding to 50% of the absorbance of the standard curve. To determine whether the proximity between the I50 of the standard curve and that of the sample would bring about a more precise result, the samples were divided into three blocks according to the criterion of difference, in modulus, of the I50 of the standard curve and of the I50 of the sample. The samples were classified into three groups. The first was composed of 20 samples with I50 up to 1.5 ng/ml, the second consisted of 21 samples with I50 ranging from 1.51 to 3 ng/ml, and the third of 17 samples with I50 ranging from 3.01 to 13 ng/ml. The determination coefficient (R² = 0.999) showed that the data obtained by gas chromatography represented a reliable basis. The results obtained by ELISA were also reliable, with an estimated Pearson correlation coefficient of 0.82 between the two methods. This coefficient for the different groups (0.88, 0.79 and 0.49 for groups 1, 2 and 3, respectively) showed greater reliability for the test with dilutions closer to I50.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Free and total carnitine quantification is important as a complementary test for the diagnosis of unusual metabolic diseases, including fatty acid degradation disorders. The present study reports a new method for the quantification of free and total carnitine in dried plasma specimens by isotope dilution electrospray tandem mass spectrometry with sample derivatization. Carnitine is determined by looking for the precursor of ions of m/z = 103 of N-butylester derivative, and the method is validated by comparison with radioenzymatic assay. We obtained an inter- and intra-day assay coefficient of variation of 4.3 and 2.3, respectively. Free and total carnitine was analyzed in 309 dried plasma spot samples from children ranging in age from newborn to 14 years using the new method, which was found to be suitable for calculating reference age-related values for free and total carnitine (less than one month: 19.3 ± 2.4 and 23.5 ± 2.9; one to twelve months: 28.8 ± 10.2 and 35.9 ± 11.4; one to seven years: 30.7 ± 10.3 and 38.1 ± 11.9; seven to 14 years: 33.7 ± 11.6, and 43.1 ± 13.8 µM, respectively). No difference was found between males and females. A significant difference was observed between neonates and the other age groups. We compare our data with reference values in the literature, most of them obtained by radioenzymatic assay. However, this method is laborious and time consuming. The electrospray tandem mass spectrometry method presented here is a reliable, rapid and automated procedure for carnitine quantitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reverse transcription-polymerase chain reaction (RT-PCR) is the most sensitive method used to evaluate gene expression. Although many advances have been made since quantitative RT-PCR was first described, few reports deal with the mathematical bases of this technique. The aim of the present study was to develop and standardize a competitive PCR method using standard-curves to quantify transcripts of the myogenic regulatory factors MyoD, Myf-5, Myogenin and MRF4 in chicken embryos. Competitor cDNA molecules were constructed for each gene under study using deletion primers, which were designed to maintain the anchorage sites for the primers used to amplify target cDNAs. Standard-curves were prepared by co-amplification of different amounts of target cDNA with a constant amount of competitor. The content of specific mRNAs in embryo cDNAs was determined after PCR with a known amount of competitor and comparison to standard-curves. Transcripts of the housekeeping ß-actin gene were measured to normalize the results. As predicted by the model, most of the standard-curves showed a slope close to 1, while intercepts varied depending on the relative efficiency of competitor amplification. The sensitivity of the RT-PCR method permitted the detection of as few as 60 MyoD/Myf-5 molecules per reaction but approximately 600 molecules of MRF4/Myogenin mRNAS were necessary to produce a measurable signal. A coefficient of variation of 6 to 19% was estimated for the different genes analyzed (6 to 9 repetitions). The competitive RT-PCR assay described here is sensitive, precise and allows quantification of up to 9 transcripts from a single cDNA sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to develop a simplified low cost method for the collection and fixation of pediatric autopsy cells and to determine the quantitative and qualitative adequacy of extracted DNA. Touch and scrape preparations of pediatric liver cells were obtained from 15 cadavers at autopsy and fixed in 95% ethanol or 3:1 methanol:acetic acid. Material prepared by each fixation procedure was submitted to DNA extraction with the Wizard® genomic DNA purification kit for DNA quantification and five of the preparations were amplified by multiplex PCR (azoospermia factor genes). The amount of DNA extracted varied from 20 to 8,640 µg, with significant differences between fixation methods. Scrape preparation fixed in 95% ethanol provided larger amount of extracted DNA. However, the mean for all groups was higher than the quantity needed for PCR (50 ng) or Southern blot (500 ng). There were no qualitative differences among the different material and fixatives. The same results were also obtained for glass slides stored at room temperature for 6, 12, 18 and 24 months. We conclude that touch and scrape preparations fixed in 95% ethanol are a good source of DNA and present fewer limitations than cell culture, tissue paraffin embedding or freezing that require sterile material, culture medium, laboratory equipment and trained technicians. In addition, they are more practical and less labor intensive and can be obtained and stored for a long time at low cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alternative methods to the utilization of laboratory animal blood and its by-products are particularly attractive, especially regarding hamsters due to their small size and difficulties in obtaining serial blood samples. Steroid hormone metabolite quantification in feces, widely used in studies of free-ranging or intractable animals, is a non-invasive, non-stressor, economical, and animal saving technique which allows longitudinal studies by permitting frequent sampling of the same individual. The present study was undertaken to determine the suitability of this method for laboratory animals. Estradiol and progesterone metabolites were quantified by radioimmunoassay in feces of intact, sexually mature female Syrian hamsters during the estrous cycle (control) and in feces of superovulated females. Metabolites were extracted by fecal dilution in ethanol and quantified by solid phase radioimmunoassay. Median estrogen and progesterone concentrations were 9.703 and 180.74 ng/g feces in the control group, respectively. Peaks of estrogen (22.44 ± 4.54 ng/g feces) and progesterone (655.95 ± 129.93 ng/g feces) mean fecal concentrations respectively occurred 12 h before and immediately after ovulation, which is easily detected in this species by observation of a characteristic vaginal postovulatory discharge. Median estrogen and progesterone concentrations (28.159 and 586.57 ng/g feces, respectively) were significantly higher in superovulated animal feces (P < 0.0001). The present study demonstrated that it is possible to monitor ovarian activity in Syrian hamsters non-invasively by measuring fecal estradiol and progesterone metabolites. This technique appears to be a quite encouraging method for the development of new endocrinologic studies on laboratory animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study describes an auxiliary tool in the diagnosis of left ventricular (LV) segmental wall motion (WM) abnormalities based on color-coded echocardiographic WM images. An artificial neural network (ANN) was developed and validated for grading LV segmental WM using data from color kinesis (CK) images, a technique developed to display the timing and magnitude of global and regional WM in real time. We evaluated 21 normal subjects and 20 patients with LVWM abnormalities revealed by two-dimensional echocardiography. CK images were obtained in two sets of viewing planes. A method was developed to analyze CK images, providing quantitation of fractional area change in each of the 16 LV segments. Two experienced observers analyzed LVWM from two-dimensional images and scored them as: 1) normal, 2) mild hypokinesia, 3) moderate hypokinesia, 4) severe hypokinesia, 5) akinesia, and 6) dyskinesia. Based on expert analysis of 10 normal subjects and 10 patients, we trained a multilayer perceptron ANN using a back-propagation algorithm to provide automated grading of LVWM, and this ANN was then tested in the remaining subjects. Excellent concordance between expert and ANN analysis was shown by ROC curve analysis, with measured area under the curve of 0.975. An excellent correlation was also obtained for global LV segmental WM index by expert and ANN analysis (R² = 0.99). In conclusion, ANN showed high accuracy for automated semi-quantitative grading of WM based on CK images. This technique can be an important aid, improving diagnostic accuracy and reducing inter-observer variability in scoring segmental LVWM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The total number of CD34+ cells is the most relevant clinical parameter when selecting human umbilical cord blood (HUCB) for transplantation. The objective of the present study was to compare the two most commonly used CD34+ cell quantification methods (ISHAGE protocol and ProCount™ - BD) and analyze the CD34+ bright cells whose 7-amino actinomycin D (7AAD) analysis suggests are apoptotic or dead cells. Twenty-six HUCB samples obtained at the Placental Blood Program of New York Blood Center were evaluated. The absolute numbers of CD34+ cells evaluated by the ISHAGE (with exclusion of 7AAD+ cells) and ProCount™ (with exclusion of CD34+ bright cells) were determined. Using the ISHAGE protocol we found 35.6 ± 19.4 CD34+ cells/µL and with the ProCount™ method we found 36.6 ± 23.2 CD34+ cells/µL. With the ProCount™ method, CD34+ bright cell counts were 9.3 ± 8.2 cells/µL. CD34+ bright and regular cells were individually analyzed by the ISHAGE protocol. Only about 1.8% of the bright CD34+ cells are alive, whereas a small part (19.0%) is undergoing apoptosis and most of them (79.2%) are dead cells. Our study showed that the two methods produced similar results and that 7AAD is important to exclude CD34 bright cells. These results will be of value to assist in the correct counting of CD34+ cells and to choose the best HUCB unit for transplantation, i.e., the unit with the greatest number of potentially viable stem cells for the reconstitution of bone marrow. This increases the likelihood of success of the transplant and, therefore, the survival of the patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phosphatidylserine (PS) exposure occurs during the cell death program and fluorescein-labeled lactadherin permits the detection of PS exposure earlier than annexin V in suspended cell lines. Adherent cell lines were studied for this apoptosis-associated phenomenon to determine if PS probing methods are reliable because specific membrane damage may occur during harvesting. Apoptosis was induced in the human tongue squamous carcinoma cell line (Tca8113) and the adenoid cystic carcinoma cell line (ACC-2) by arsenic trioxide. Cells were harvested with a modified procedure and labeled with lactadherin and/or annexin V. PS exposure was localized by confocal microscopy and apoptosis was quantified by flow cytometry. The detachment procedure without trypsinization did not induce cell damage. In competition binding experiments, phospholipid vesicles competed for more than 95 and 90% of lactadherin but only about 75 and 70% of annexin V binding to Tca8113 and ACC-2 cells. These data indicate that PS exposure occurs in three stages during the cell death program and that fluorescein-labeled lactadherin permitted the detection of early PS exposure. A similar pattern of PS exposure has been observed in two malignant cell lines with different adherence, suggesting that this pattern of PS exposure is common in adherent cells. Both lactadherin and annexin V could be used in adherent Tca8113 and ACC-2 cell lines when an appropriate harvesting procedure was used. Lactadherin is more sensitive than annexin V for the detection of PS exposure as the physical structure of PS in these blebs and condensed apoptotic cell surface may be more conducive to binding lactadherin than annexin V.